POINT LOAD TESTER. Model PIL-7. Roctest Limited, All rights reserved.

Similar documents
TAPE EXTENSOMETER Model CONVEX-D. Roctest Limited, All rights reserved.

WATER LEVEL INDICATOR. Model CPR. Roctest Limited, All rights reserved.

INSTRUCTION MANUAL ANCHOR LOAD CELL. Model ANCLO

VIBRATING WIRE SURFACE STRAIN GAUGE. Model SM-5B. Roctest Limited, All rights reserved.

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

VIBRATING WIRE FILL EXTENSOMETER. Model ERI. Roctest Limited, All rights reserved.

RETRIEVABLE BOREHOLE EXTENSOMETER. Model BOF-EX. Roctest Limited, All rights reserved.

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

SPECIFICATIONS CONTENTS: Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Refinery Supply Company, Inc.

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Hand Held Pull Tester Instruction Manual Order No

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

VIBRATING WIRE DISPLACEMENT TRANSDUCERS. JM Series. Roctest Limited, All rights reserved.

PE 20 SERIES ELECTRIC POWER PUMPS

TLD 2500 Tube Testing Guns

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Under Axle Jack Max. Capacity: 25 Tons

Post Driver Attachment

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

USE OF ENERPAC HYDRAULIC EQUIPMENT PRESENTED BY: HARDISH TRIVEDI

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Portable Two-Stage Under Axle Jack Max. Capacity: First Stage: 27.5 Tons Second Stage: 11 Tons. Safety Precautions

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

Air / Hydraulic Under Axle Jack

ABSOLUTE EQUIPMENT PTY LTD

HEAVY DUTY TROLLEY JACK. Operation Manual

Instruction Sheet 1 1/8 HP TITAN PUMPS SAFETY FIRST

ABSOLUTE EQUIPMENT PTY LTD

High Lift Transmission Jack

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

Operator s Manual Portable Wood Chip Moisture Tester ENGLISH

KLW4000D Multi-Port Power Pack

Be sure pins are actually seated in their respective slots before applying any pressure.

PNEUMATIC SLIDING VALVE

Motorcycle/ATV Lift. Max. Capacity: 1,500 lbs. Parts List

Operating instructions Form no safety definitions

Instruction Manual. Maximum Operating Pressure 700 bar

Concrete ASTM COMPRESSION TESTER ACCESSORIES

LEAK TEST PROCEDURE MRT4-DC LIFTERS SINGLE VACUUM SYSTEMS TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Air-Assist Service Jack Max. Capacity: 10 Tons

Pressure Sensor No Series

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

Battery Powered Hydraulic Pump; Kit PN [ ]

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

Low Lift Transmission Jack

Hydraulic Knockout Sets

SERIES OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

767 Hydraulic Hand Pump

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Index. 1. Important safety instructions Overview of the lift Installation instructions Operation instructions 8-9

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

VW Surface-Mount Strain Gauge

Instructions for Installation, Operation Care and Maintenance

EU32 HYDRAULIC CRIMPER OPERATORS MANUAL

Section 10 Chapter 20

2 TON CAPACITY PROFESSIONAL SERIES ALUMINUM JACK OWNER'S MANUAL SPECIFICATIONS

MF205, MF205-4, MF210, MF210-4, MF220 & MF220-4 Compact

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

6602LP CAPACITY: 2 TON LOW RIDER SERVICE JACK

SENSOPTIC FIBER-OPTIC DISPLACEMENT TRANSDUCER. Model FOD. Roctest Limited, All rights reserved.

Instruction Manual. Single Acting, High Tonnage, Low Height Cylinders RSH Series. Maximum Operating Pressure 700 bar

HYDRAULIC SPRING COMPRESSOR SET

FIBERGLASS RODS BOREHOLE EXTENSOMETER WITH GROUTABLE ANCHORS AND VW SENSORS Model BOREX-E. Roctest Limited, All rights reserved.

CARVER. OPERATION, INSTALLATION AND MAINTENANCE MANUAL UNHEATED TWO and FOUR POST MANUAL HYDRAULIC PRESSES

HexPro Series Low Profile Wrenches

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

Operating Instructions - Electric Pow'r-Riser Models

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

Instruction Manual. Maximum Operating Pressure 510 bar

16000SIII Automatic Grease System

3-TONNE GARAGE JACK OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CTJ3000GB PART NO: ORIGINAL INSTRUCTIONS

The ELM Series Slurry Pump Installation and Operating Manual

Model Differential Sticking Tester Instruction Manual

Instruction Manual. Square Drive Hydraulic Torque Wrenches Model TW Series. Maximum Operating Pressure 700 bar

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

Low Profile Wrenches Operation and Maintenance Manual

for filling and bleeding hydraulic disk brake systems Instruction


Pressure Relief Valve Maintenance Manual

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

6722 Rev. A CAPACITY: 22 TON TRUCK AXLE JACK WITH AIR RETURN

METEOROLOGICAL INSTRUMENTS

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

Racing Jack Max. Capacity: 3,000 lbs. (1,361 kg)

Air / Hydraulic Pump

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

10 & 20 TON UTILITY PRESS

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

Fisher 657 Diaphragm Actuator Sizes and 87

Transcription:

INSTRUCTION MANUAL POINT LOAD TESTER Model Roctest Limited, 2011. All rights reserved. This product should be installed and operated only by qualified personnel. Its misuse is potentially dangerous. The Company makes no warranty as to the information furnished in this manual and assumes no liability for damages resulting from the installation or use of this product. The information herein is subject to change without notification. Tel.: 1.450.465.1113 1.877.ROCTEST (Canada, USA) 33 (1) 64.06.40.80 (Europe) www.roctest.com www.telemac.fr E1048A-110530

TABLE OF CONTENTS 1 INTRODUCTION... 1 2 DESCRIPTION... 1 3 TEST PROCEDURE... 2 3.1 Types of point load tests... 2 3.2 Possible adjustment... 3 3.3 Operation... 3 4 INTERPRETATION... 5 5 MAINTENANCE... 7 5.1 Plunger cleaning and oil change... 7 5.2 Re-filling the jack reservoir... 7 5.3 Cleaning air vent hole (exceptional)... 9 5.4 Fixing small oil leaks... 9 6 MISCELLANEOUS... 9 6.1 References... 9 6.2 Conversion factors... 10 i

1 INTRODUCTION Point load tester model is a simple portable apparatus used for testing rock samples or cores. The has a maximum loading capacity of seven tons metric and accepts drill cores or rock lumps of different sizes having a maximum length of 102 mm. The point load strength index obtained from a point load test is correlated with the uniaxial compressive strength of the rock tested. Being rapid and simple to perform, the point load test allows the user to easily delineate zones of rock of different strength properties. It then becomes a most useful tool in large-scale mining as well as civil engineering projects for classifying rock types from a mechanical perspective. 2 DESCRIPTION The point load tester basically consists of the following components: - a rigid loading frame onto which a fixed hydraulic jack provides the load for bringing a rock disc to failure in between two conical end platens; - a high-pressure hydraulic coupler onto which a numerical pressure gage is mounted for failure load determination. Figure 1: Point load tester model 1

The top conical end is fixed on the loading frame and the bottom one is mounted on the piston of the hydraulic jack. A removable spacer is installed between the lower conical platen and the jack piston in order to prevent the sagging of the piston during test with core of small diameter. Other spacers are available upon request to suit specific core diameters. A small graduated scale fixed on the side of the loading frame permits an easy determination of the diameter of the core. The conical platen shape and tip radius follow the ISRM (International Society for Rock Mechanics) Suggested method for determining point load strength. A copy of the document is provided in appendix A, which is an integral part of this manual. The user should refer to the ISRM suggested method for details concerning the point load strength test. The capacity of the hydraulic jack is seven tons metric, which corresponds approximately to a pressure of 72.412 MPa on the pressure gage. The gage has a pressure range of 100 MPa and features a peak mode, which permits the determination of the failure load for the rock sample tested. Using this mode, the manometer takes 5000 measurements per second. In order to avoid projection of rock pieces at the moment of failure, a transparent plastic shield, which fits over the top of the tester, is provided. 3 TEST PROCEDURE 3.1 TYPES OF POINT LOAD TESTS Three point load test configurations are available for core logging. Diametral test Axial test This test is the most reproducible and is independent of the core length provided that the length/diameter ratio is equal to or greater than 1.0. When only rock discs are available or when discs are produced with the diametral test, the axial test can be performed on core specimens with length/diameter ratios between 0.3 and 1.0. This test is useful to evaluate strength anisotropy. Irregular lump test If irregularly shaped rock pieces are the only specimens available, tests can still be performed on lumps having an equivalent core diameter close to 50 mm and an overall approximately cubical shape. In order to fit this requirement, specimens may be prepared from larger pieces by trimming or saw or chisel cutting. 2

3.2 POSSIBLE ADJUSTMENT When delivered, the apparatus is set for testing 78 mm samples. Proceed as follows to adjust the apparatus to test longer samples (up to 102 mm). 1. With the pump lever, raise the jack piston until the lower platen reaches the upper one. 2. Untie the Allen screw located behind the scale support. Slide the scale support down until the reading reaches 0 and tie the Allen screw. 3. Push on the plunger to its retracted position. 4. Unscrew the bottom platen and the spacer and place the bottom platen back on the plunger. The apparatus is now ready for longer samples. Remember that the scale has now an offset. 3.3 OPERATION Note: At reception, the apparatus is saturated with oil and ready to be used. The following procedure is used to conduct the point load test with the tester. 1. Connect the manometer to the quick-connect connector mounted on the base of the frame. 2. Tighten the relief valve located beside the handle support by turning it clockwise. 3. Set the manometer using the manometer guide provided in appendix C. Enter into the function menu, then: - select the pressure unit, - choose the peak on, - and set the zero. Note: The manometer can display numbers up to 19999. If an OFL (overflow) message appears, change unit for a bigger one to decrease the value displayed. This operation can be done during the test itself (while raising pressure) without loosing any information. 4. Place the rock sample on the lower platen and, using the pump lever, raise the jack piston until the sample is in contact with the two conical platens. The contact location depends on the type of the test: - for a diametral test, the platens must make contact with the core along its diameter; - for an axial test, contact with the core is made along a line perpendicular to its end faces; 3

- for a lump test, contact is made along the smallest dimension of the lump, away from edges and corners. 5. Make sure the reference plate fixed on the lower platen indicates a zero reading when the two conical platens are in contact. If not, adjust it. 6. Read the distance separating the two contact point on the graduated scale fixed on the side of the loading frame. 7. Place the protective shield over the top of the tester. 8. Place the jack handle in its support and increase steadily load such that failure occurs within 10 to 60 seconds. Record the pressure at failure as shown on the bottom number of the LEO 1 manometer (the bottom number as to be set to MAX). The top number of the LEO 1 manometer is the actual value in real time and should not be used for calculations. The test is considered invalid and rejected if the fracture surface passes through only one loading point. 9. When the test is over, wipe off dust from jack piston with a lint-free cloth. Lubricate the seal at the base of the piston jack with a few drops of Enerpac oil when needed. 10. When the piston jack is cleaned, push on the plunger to its retracted position. Note: Ensure to reset the manometer to zero between each test 4

4 INTERPRETATION The load at failure is obtained thanks to the following relation. P = L A e where P = load at failure in MN L = reading of maximum pressure in MPa A e = effective area of the jack piston in m² Note: The effective area of the jack piston for model is 9.48 cm² (9.48 x 10-4 m²). The uncorrected point load strength index is calculated using the following relation and the load value previously calculated. I = S P D 2 e where I S = point load strength index in MPa P = load at failure in MN D e = equivalent core diameter in m The index I S may also be obtained graphically using the nomogram shown below presented by Broch and Franklin (1972). 5

The I S index varies as a function of the diameter of the core D in the diametral test and as a function of the equivalent diameter D e in axial, block and irregular lump tests. A size correction must be applied to obtain a unique point load strength value for the rock sample and one that can be used for purposes of rock strength classification. Please refer to the size correction procedure explained in the ISRM Suggested method given in appendix A. The same document also provides the method for evaluating the uniaxial compressive strength of the rock tested from the corrected point load strength index I S (50). Figure 2: Nomogram for computing point load strength For testing machines that employ gages calibrated in terms of hydraulic pressure, the pressure reading should be multiplied by the effective ram area to obtain load; the nomogram can be adjusted for direct readings by a vertical displacement of the failure load scale. 6

5 MAINTENANCE 5.1 PLUNGER CLEANING AND OIL CHANGE The piston jack needs to be cleaned frequently. Wipe off dust on piston jack using a lintfree cloth and lubricate seal at the base of the piston jack with a few drops of Enerpac hydraulic fluid regularly. This regular maintenance will prevent dust from entering oil reservoir. Oil change on the jack should be performed every 500 tests or when oil is contaminated (turning black) to prevent components wear. Do not use any grease with the apparatus. Grease on the plunger will damage internal components of the jack. 5.2 RE-FILLING THE JACK RESERVOIR To re-fill the reservoir of the jack, make sure first that the plunger is fully retracted or the system will contain more fluid than the reservoir can hold. Follow the procedure below. 1. Use wrench end of jack handle to open release valve by turning counterclockwise. 2. Place jack on its front face with the filler plug on top. Remove fill plug. 3. Slowly add Enerpac hydraulic fluid. Use only Enerpac hydraulic fluid otherwise damages can occur to the jack and its plunger. Another type of fluid will void the warranty. Hydraulic fluid can be provided by Roctest Telemac or directly from Enerpac (www.enerpac.com). Contents are model HF-100 to HF-104 depending on their capacities. Content HF-100 represents about 3 complete refills. 4. Once the reservoir is filled, extend the plunger out approximately 4 cm. Add enough fluid to fill the reservoir. 5. Insert the fill plug and turn in about half way, leaving the bleed hole in the fill plug exposed. 6. Push plunger to its fully retracted position. Excess oil and air will be expelled through the fill plug bleed hole. 7. Tighten fill plug. 7

8. Use wrench end of the jack handle to close the release valve by turning clockwise. 9. Pump the handle. If plunger does not advance to full travel, repeat the whole procedure. 8

5.3 CLEANING AIR VENT HOLE (EXCEPTIONAL) Always keep the air vent hole surface free of debris. To remove dust or debris from the hole, remove the four screws of the top plate and clean the little bowl in black rubber. Take care when putting the bowl back: it should stay at its initial location. Replace the top plate with the screws. 5.4 FIXING SMALL OIL LEAKS When small oil leaks occur, it generally happens near the manometer. 1. Check that the ball of the quick-connect at manometer side is free to move. 2. Check that the quick-connect is free of debris. Plug the manometer and do not hesitate to firmly tight the coupling ring by hand. 3. If the problem is not fixed, check the other couplings for oil leakage. Unscrew the defective one, add some Teflon tape, and tight it well. 6 MISCELLANEOUS 6.1 REFERENCES Appendix A BROCH, E., and J.A. Franklin. The Point Load Strength Test, International Journal of Rock Mechanics, Min. Sci., Vol. 9, 1992, pp. 669-697. Appendix B Hoek E., and Brown E., Underground Excavations in Rock, Institution of Mining and Metallurgy, MAA, 1980, pp. 14-37. 9

6.2 CONVERSION FACTORS To Convert From To Multiply By LENGTH AREA VOLUME MASS FORCE PRESSURE AND STRESS TEMPERATURE at 4 C Microns Millimetres Meters Square millimetres Square meters Cubic centimetres Cubic meters Litres Litres Kilograms Kilograms Kilograms Newtons Newtons Newtons Kilopascals Bars Inches head of water Inches head of Hg Pascal Kilopascals Kilopascals Kilopascals Inches Inches Feet Square inches Square feet Cubic inches Cubic feet U.S. gallon Can Br gallon Pounds Short tons Long tons Pounds-force Kilograms-force Kips Psi Psi Psi Psi Newton / square meter Atmospheres Bars Meters head of water Temp. in F = (1.8 x Temp. in C) + 32 Temp. in C = (Temp. in F 32) / 1.8 Table 1: Conversion factors 3.94E-05 0.0394 3.2808 0.0016 10.7643 0.06101 35.3357 0.26420 0.21997 2.20459 0.00110 0.00098 0.22482 0.10197 0.00023 0.14503 14.4928 0.03606 0.49116 1 0.00987 0.01 0.10197 E6TabConv-990505 10

APPENDIX C GUIDE OF DIGITAL MANOMETER KELLER MODEL LEO 1 a

KEY FUNCTIONS KEY ON Wait for the instrument measuring mode (about 3 s). RESET Max. / min. value and peak value are set to the actual pressure. OFF Turns off the manometer. MANO Enter into manometer functions. PEAK OFF / PEAK ON Peak off: Normal measuring mode with 2 measurements per second. Peak on: Fast measuring mode with 5000 measurements per second. ZERO SET Sets a new zero reference. ZERO RES Sets the zero to factory setting. CONT ON / CONT OFF Cont on: Deactivates the automatic turn-off function. Cont off: Activates the automatic turn-off function. UNIT ION Bar UNIT ION hpa (mbar) UNIT ION kpa UNIT ION MPa UNIT ION psi UNIT ION kp/cm² b

Example: Setting a new zero reference Turn on the manometer by shortly pressing the key. Press the key 3 times: MANO appears. Press : PEAK ON or PEAK OFF appears. Press : ZERO SET appears. Press : The new Zero reference is set. The manometer returns to the measuring mode. c