Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Similar documents
High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

Single-inlet centrifugal fans

KV sileo 100 M. Circular duct fans. Circular duct fans

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Max. airflow m 3 /s Diam. min. Diam. max

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS

ROOFMASTER STEF-HT ROOF FAN

MegaBox Product-specific information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

ROOFMASTER STEF-HT ROOF FAN

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Circular Duct Fan prioair

IN-LINE CENTRIFUGAL DUCT FANS VT Series

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

ROOFMASTER STEF-ATEX ROOF FAN

CENTRIFUGAL IN-LINE FANS VENT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

Mixed Flow Roof Fans (RMH)

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

ACOUSTIC CABINET FANS CVAB / CVAT Series

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

ROOFMASTER STEF ROOF FAN

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

AC Commercial Fans Edition. ErP ready

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

Axial fans. What s more, non-stock models are normally available within two weeks.

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Mixed Flow Roof Fans (RMH)

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

CK, LPK, LPKB. Duct fans with circular connection.

In-line rectangular fans. Technical Catalogue

HIGH-POWERED VENTILATORS

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF FAN ROOFMASTER STEC

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

MAJAX-2 GENERAL SPECIFICATION

GigaBox centrifugal fans Product specific information

Plate mounted axial flow fans HXBR / HXTR Series

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Performance. Sound Levels. Impellers. Motors. Accessories

Unobox units with backward curved centrifugal impellers

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

Heat recovery units type GTDHR

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Sabre Plate Mounted Sickle Fans (VSP)

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Hison Axial Flow Fans

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Accessories. Controllers / Sensors. Duct Heaters / Cooling Coils

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

Hison Axial Flow Fans

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Multifunctional 400ºC/2h and 300ºC/2h roof fans

HIGH TEMPERATURE TWIN SQUIF FANS

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Kitchen exhaust fan GLEB

Sentinel D-Box Twin Fan

CYCLONE F 400 smoke extraction casing

Vent-Axia Sabre Sickle Roof Fans (VSR)

Transcription:

General Systemair thermo fans have been developed for the use in exhaust air systems where media with increased temperatures have to be transported. The special design allows a reliable operation also in systems with higher demands due to increased temperatures or polluted air, for example from kitchens, industrial ovens or in process air. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K variant masters higher demands due to the motor being separated from the air stream. Should regular maintenance/cleaning be necessary, the Systemair ranges KBT/KBR with swing out impeller/door assembly is the ideal solution. For roof exhaust installations we are offering our ranges DNV/DVNI with motor separated from the airstream. Systemair fans are suited to transport media with a continuous temperature of either 100 C or 120 C, depending on the range. Motors Thermo fans are equipped with IEC standard motors, with some exceptions speed controllable by voltage. All motors with protection class IP 54 and insulation class F. Motors with thermal contacts and extended leads for connection to a Systemair motor protection unit. Standard execution ASF/KB Flexible connection KBT/KBR WSD Weather roof for motor ASF/KB Flexible connection WBK Wall mounting bracket FGV-K Flexible connection UGS MUB-K FGV-K Flexible connection 163

KBT 160-200 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBT fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame.to protect the motors from overheating the KBT fans have integral thermal contacts with external leads for connection to a motor protection device. KBT 160E4 KBT 160DV KBT 180E4 KBT 200E4 Voltage/Frequency V/50 Hz 230 400 230 230 Phase ~ 1 3 1 1 Power at shaft W 140 160 140 750 Current A 1,11 0,57 1,11 5,1 Maximum air flow m 3 /s (m 3 /h) 0,23 (830) 0,25 (900) 0,39(1240) 0,54(1950) R.p.m. min -1 1330 1120 1330 1370 Max. temp of transp. air C 120 120 120 120 Max. temp of transp. air when speed-controlled C 120 120 120 120 Sound pressure level at 4/10 m db(a) 31/23 31/23 34/26 37/29 Weight kg 25 24 29 35 Insulation class F F F F Enclosure class IP 54 IP 54 IP54 IP54 Capacitor μf 6-6 30 Motor protection S-ET 10 STDT 16 S-ET 10 S-ET 10 Speed control, five step Transformer RTRE 1,5 RTRD 2 RTRE 1,5 RTRE 7 Speed control, five step high/low Transformer REU 1,5 + S-ET 10 RTRDU 2 REU 1,5 + S-ET 10 REU 7 + S-ET 10 Speed control, D/ two step 400 V Transformer - S-DT2 SKT - - Wiring diagram p. 11-17 21 17 21 21 A B C D E øg H J KBT 160 127,4 382 213 248 435 160 149 207 KBT 180 134,4 412 230 269 470 200 161 219 KBT 200 142,7 445 249 292 510 200 174 232 164

WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBT 160E4 L wa Inlet db(a) 72 70 66 63 59 57 53 49 L wa Outlet db(a) 74 72 68 65 61 59 55 51 L wa Surrounding db(a) 54 52 48 45 41 39 35 31 Measuring point: q v = 0,12 m 3 /s, P s = 120 Pa KBT 160DV = Star connection; low speed L wa Inlet db(a) 72 70 66 63 59 57 53 49 L wa Outlet db(a) 74 72 68 65 61 59 55 51 L wa Surrounding db(a) 54 52 48 45 41 39 35 31 Measuring point: q v = 0,14 m 3 /s, P s = 134 Pa REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 KBT 180E4 L wa Inlet db(a) 75 73 69 66 62 60 56 52 L wa Outlet db(a) 77 75 71 68 64 62 58 54 L wa Surrounding db(a) 57 55 51 48 44 42 38 34 Measuring point: q v = 0,21 m 3 /s, P s = 210 Pa KBT 200E4 L wa Inlet db(a) 78 76 72 69 65 63 59 55 L wa Outlet db(a) 80 78 74 71 67 65 61 57 L wa Surrounding db(a) 60 58 54 51 47 45 41 37 Measuring point: q v = 0,26 m 3 /s, P s = 280 Pa RTRE p. 454 RTRDU/RTRD p. 455 165

KBT 200-250 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBT fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBT fans have integral thermal contacts with external leads for connection to a motor protection device. KBT 200DV KBT 225E4 KBT 225DV KBT 250E4 Voltage/Frequency V/50 Hz 400 230 230 230 Phase ~ 3 1 3 1 Power at shaft W 550 750 750 1840 Current A 1,88 5,1 2,3 10,4 Maximum air flow m 3 /s (m 3 /h) 0,58 (2100) 0,76 (2750) 0,76 (2750) 1,08 (3900) R.p.m. min -1 1360 1370 1340 1053 Max. temp of transp. air C 120 120 120 120 Max. temp of transp. air when speed-controlled C 120 120 120 120 Sound pressure level at 4/10 m db(a) 37/29 41/33 41/33 45/37 Weight kg 38 40 38 52 Insulation class F F F F Enclosure class IP 54 IP 54 IP 54 IP 54 Capacitor μf - 30-50 Motor protection STDT 16 S-ET 10 STDT 16 AWE-SK Speed control, five step Transformer RTRD 2 RTRE 7 RTRD 4 - Speed control, five step high/low Transformer RTRDU 2 REU + S-ET 10 RTRDU 4 - Speed control, D/ two step 400 V Transformer S-DT2 SKT - S-DT2 SKT - Wiring diagram p. 11-17 17 21 17 21 A B C D E øg H J KBT 200 142,7 445 249 292 510 200 174 232 KBT 225 146,5 455 256 301 522 225 193 251 KBT 250 162 500 282 333 576 250 213 272 166

WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBT 200DV = Star connection; low speed L wa Inlet db(a) 78 76 72 69 65 63 59 55 L wa Outlet db(a) 80 78 74 71 67 65 61 57 L wa Surrounding db(a) 60 58 54 51 47 45 41 37 Measuring point: q v = 0,29 m 3 /s, P s = 280 Pa KBT 225E4 L wa Inlet db(a) 82 80 76 73 69 67 63 59 L wa Outlet db(a) 84 82 78 75 71 69 65 61 L wa Surrounding db(a) 64 62 58 55 5 49 45 41 Measuring point: q v = 0,49 m 3 /s, P s = 285 Pa S-DT2 SKT p. 463 REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 = Star connection; low speed KBT 225DV L wa Inlet db(a) 82 80 76 73 69 67 63 59 L wa Outlet db(a) 84 82 78 75 71 69 65 61 L wa Surrounding db(a) 64 62 58 55 51 49 45 41 Measuring point: q v = 0,37 m 3 /s, P s = 382 Pa KBT 250E4 Min. static back pressure: 180 Pa L wa Inlet db(a) 86 84 80 77 73 71 67 63 L wa Outlet db(a) 88 86 82 79 75 73 69 65 L wa Surrounding db(a) 68 66 62 59 55 53 49 45 Measuring point: q v = 0,56 m 3 /s, P s = 500 Pa RTRE p. 454 RTRDU/RTRD p. 455 167

KBT 250-280 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBT fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBT fans have integral thermal contacts with external leads for connection to a motor protection device. KBT 250DV KBT 280DV Voltage/Frequency V/50 Hz 400 400 Phase ~ 3 3 Power at shaft W 1500 2200 Current A 4,3 5,8 Maximum air flow m 3 /s (m 3 /h) 1,11 (4000) 1,22 (4400) R.p.m. min -1 1340 1330 Max. temp of transported air C 120 120 Max. temp of transported air when speed-controlled C 120 120 Sound pressure level at 4/10 m db(a) 45/37 48/40 Weight kg 51 68 Insulation class F F Enclosure class IP 54 IP 54 Capacitor μf - - Motor protection STDT 16 STDT 16 Speed control, five step Transformer RTRD 7 RTRD 7 Speed control, five step high/low Transformer RTRDU 7 RTRDU 7 Speed control, D/ two step 400 V Transformer S-DT2 SKT S-DT2 SKT Wiring diagram p. 11-17 17 17 A B C D E øg H J KBT 250 162 500 282 333 576 250 213 272 KBT 280 172 537 295 360 625 280 234 291 168

WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBT 250DV = Star connection; low speed L wa Inlet db(a) 86 84 80 77 73 71 67 63 L wa Outlet db(a) 88 86 82 79 75 73 69 65 L wa Surrounding db(a) 68 66 62 59 55 53 49 45 Measuring point: q v = 0,67 m 3 /s, P s = 400 Pa KBT 280DV = Star connection; low speed Min. static back pressure: 240 Pa L wa Inlet db(a) 89 87 83 80 76 74 70 66 L wa Outlet db(a) 91 89 85 82 78 76 72 68 L wa Surrounding db(a) 71 69 65 62 58 56 52 46 Measuring point: q v = 0,60 m 3 /s, P s = 630 Pa S-DT2 SKT p. 463 REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 RTRE p. 454 RTRDU/RTRD p. 455 169

KBR 280 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBR fans have impellers manufactured from galvanized steel with backward-curved blades and external rotor motors. The KBR casing is manufactured from doubleskinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBR fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBR fans have integral thermal contacts with external leads for connection to a motor protection device. KBR 280D2 KBR 280D2-4 KBR 280DV Voltage/Frequency V/50 Hz 400 400 400 Phase ~ 3 3 3 Power at shaft *) W 550 480/120 370 Current A 2,2 1,2/0,33 1,39 Maximum air flow m 3 /s (m 3 /h) 0,8 (2900) 0,8 (2900)/0,42 (1520) 0,42 (1520) R.p.m. min -1 2760 2800/1410 1360 Max. air speed on outlet m/s 13,5 13,5/7,2 7,2 Max. temp of transported air C 120 120 120 Max. temp of transported air when speed-controlled C 120 120 120 Sound pressure level at 4/10 m db(a) 44/36 44/36-33/25 33/25 Weight kg 48 49 48 Insulation class F F F Enclosure class IP 55 IP 55 IP 54 Motor protection - - STDT 16 Speed control, five step Transformer - - RTRD 2 Speed control, five step high/low Transformer - - RTRDU 2 Speed control, D/ two step 400 V Transformer - - S-DT2 SKT Wiring diagram p. 11-17 17 14 17 *) Shaft radiated power IEC standard engine To guarantee the function of the installation without any problems, we advise to rate the fan in that way that the flow speed on the outlet don t rise above 10 m/s. A B C D E øg H I J L KBR 280 171,5 537 295 360 625 280 234 142,5 291 600 170

1400 0 500 1000 1500 2000 2500 3000 3500 350 400 800 1200 1600 2000 1200 KBR 280D2 300 KBR 280DV WSD p. 488 1000 86 250 74 800 600 2-pol 200 150 ASF/KB p. 489 400 200 74 4-pol 72 84 100 50 72 WBK p. 489 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0 200 400 600 800 KBR 280D2 Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 86 83 80 78 74 71 69 65 61 L wa Outlet db(a) 88 85 82 80 76 73 71 67 61 L wa Surrounding db(a) 67 64 61 59 55 52 50 46 42 Measuring point: q v = 0,42 m 3 /s, P s = 800 Pa 0 200 400 600 800 KBR 280DV Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 74 71 68 66 62 59 57 53 49 L wa Outlet db(a) 76 73 70 68 64 61 59 55 51 L wa Surrounding db(a) 56 53 50 48 44 41 39 35 31 Measuring point: q v = 0,02 m 3 /s, P s = 220 Pa ALS/KBT p. 489 S-DT2 SKT p. 463 REV p. 463 STDT p. 464 RTRDU/RTRD p. 455 171

KBR 315DV-355E4 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBR fans have impellers manufactured from aluminium with backward-curved blades. The KBR casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBR fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBR fans have integral thermal contacts with external leads for connection to a motor protection device. KBR 315DV KBR 315DZ KBR 355E4 KBR 355E4/K Voltage/Frequency V/50 Hz 400 400 230 230 Phase ~ 3 3 1 1 Power at shaft *) W 370 1500 370 370 Current A 1,39 3,40 2,10 2,10 Air flow m 3 /s (m 3 /h) 0,61 (2200) 1,10 (3950) 0,97 (3500) 0,78 (2800) Max. air speed at outlet m/s 7,8 14,1 9,8 7,9 R.p.m. min -1 1360 2710 1330 1330 Max. temp of transported air C 120 120 120 120 Max. temp of transported air when speed-controlled C 120 120 120 120 Sound pressure level at 4/10 m db(a) 36/28 51/43 44/33 42/31 Weight kg 75 82 81 80 Insulation class F F F F Enclosure class IP 54 IP 54 IP 54 IP 54 Capacitor μf - - 12 12 Motor protection STDT 16 STDT 16 S-ET 10 S-ET 10 Speed control, five step Transformer RTRD 2 RTRD 4 RTRE 3 RTRE 3 Speed control, five step high/low Transformer RTRDU 2 RTRDU 4 REU 3 + S-ET 10 REU 3 + S-ET 10 Speed control, D/ two step 400V S-DT2 SKT S-DT2 SKT - - Wiring diagram p. 11-17 17 17 21 21 *) Shaft radiated power IEC standard engine To guarantee the function of the installation without any problems, we advise to rate the fan in that way that the flow speed on the outlet don t rise above 10 m/s. A B C D E øg H I J L KBR 315 187,5 600 339 398 690 315 249 153,5 307 800 KBR 355 206,7 655 372 451 770 355 273 162,5 331 770 172

WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBR 315DV = Star connection; low speed L wa Inlet db(a) 77 75 74 69 67 63 57 54 L wa Outlet db(a) 79 77 76 71 68 65 59 56 L wa Surrounding db(a) 59 57 56 51 49 45 39 36 Measuring point: q v = 0,38 m 3 /s, P s = 250 Pa KBR 315DZ = Star connection; low speed L wa Inlet db(a) 92 90 89 84 82 78 72 69 L wa Outlet db(a) 94 92 91 86 84 80 74 71 L wa Surrounding db(a) 74 72 71 66 64 60 54 51 Measuring point: q v = 0,46 m 3 /s, P s = 1276 Pa S-DT2 SKT p. 463 REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 KBR 355E4 L wa Inlet db(a) 82 80 79 74 72 68 62 59 L wa Outlet db(a) 84 82 81 76 74 70 64 61 L wa Surrounding db(a) 64 62 61 56 54 50 44 41 Measuring point: q v = 0,42 m 3 /s, P s = 465 Pa KBR 355E4/K L wa Inlet db(a) 80 78 74 71 67 65 61 57 L wa Outlet db(a) 82 80 76 73 69 67 63 59 L wa Surrounding db(a) 62 60 56 53 49 47 43 39 Measuring point: q v = 0,42 m 3 /s, P s = 320 Pa RTRE p. 454 RTRDU/RTRD p. 455 173

KBR 355DV-DZ Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBR fans have impellers manufactured from aluminium with backward-curved blades and external rotor motors. The KBR casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBR fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBR fans have integral thermal contacts with external leads for connection to a motor protection device. KBR 355DV KBR 355DV/K KBR 355DZ KBR 355DZ/K Voltage/Frequency V/50 Hz 400 400 400 400 Phase ~ 3 3 3 3 Power at shaft *) W 370 370 3000 2200 Current A 1,39 1,39 6,5 5,00 Air flow m 3 /s (m 3 /h) 1,06 (3800) 0,81 (2900) 1,97 (7100) 1,53 (5500) Max. air speed at outlet m/s 10,7 8,2 19,9 15,5 R.p.m. min -1 1360 1360 2600 2660 Max. temp of transported air C 120 120 120 120 Max. temp of transported air when speed-controlled C 120 120 120 120 Sound pressure level at 4/10 m db(a) 41/33 41/33 54/46 54/46 Weight kg 81 81 100 100 Insulation class F F F F Enclosure class IP 54 IP 54 IP54 IP54 Motor protection STDT 16 STDT 16 STDT 16 STDT 16 Speed control, five step Transformer RTRD 2 RTRD 2 RTRD 7 RTRD 7 Speed control, five step high/low Transformer RTRDU 2 RTRDU 2 RTRDU 7 RTRDU 7 Speed control, D/ two step 400 V Transformer S-DT2 SKT S-DT2 SKT S-DT2 SKT S-DT2 SKT Wiring diagram p. 11-17 17 17 17 17 *) Shaft radiated power IEC standard engine To guarantee the function of the installation without any problems, we advise to rate the fan in that way that the flow speed on the outlet don t rise above 10 m/s. 174

WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBR 355DV = Star connection; low speed Mid-frequency band, H L wa Inlet db(a) 82 80 79 74 72 68 62 59 L wa Outlet db(a) 84 82 81 76 74 70 64 61 L wa Surrounding db(a) 64 62 61 56 54 50 44 41 Measuring point: q v = 0,69 m 3 /s, P s = 320 Pa = Star connection; low speed KBR 355DV/K Mid-frequency band, H L wa Inlet db(a) 82 80 79 74 72 68 62 59 L wa Outlet db(a) 84 82 81 76 74 70 64 61 L wa Surrounding db(a) 64 62 61 56 54 50 44 41 Measuring point: q v = 0,32 m 3 /s, P s = 398 Pa S-DT2 SKT p. 463 REV p. 463 KBR 355DZ = Star connection; low speed L wa Inlet db(a) 95 93 92 87 85 81 75 72 L wa Outlet db(a) 97 95 94 89 87 83 77 74 L wa Surrounding db(a) 77 75 74 69 67 63 57 54 Measuring point: q v = 0,83 m 3 /s, P s = 1800 Pa = Star connection; low speed KBR 355DZ/K L wa Inlet db(a) 95 93 92 87 85 81 75 72 L wa Outlet db(a) 97 95 94 89 87 83 77 74 L wa Surrounding db(a) 77 75 74 69 67 63 57 54 Measuring point: q v = 0,72 m 3 /s, P s = 1431 Pa STDT p. 464 RTRDU/RTRD p. 455 175

MUB042 400DV-K2-500DV-K2 Motor outside of the air stream Speed-controllable Modular system Integral thermal contacts Low sound level Maintenance-free and reliable All MUB-K2 fans have impellers with backward curved blades, manufactured from aluminium, and IEC standard motors, which can be speed controlled by transformer, except size 630-D4. Motors are outside the air stream. The casing consists of an aluminium frame with fiberglass reinforced plastic corners and double skin, galvanised steel panels with a 20 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions. With quick-lock access door. The MUB casing is equipped with a grease tray under the impeller and a protection guard at the motor side. An isolator switch is mounted on the casing. All MUB-K2 motors (except 630D4) are D/ connected for two speed operation. Motor protection by thermal contacts, to be connected to an external motor protection device. Standard execution, seen in airflow direction: service door left, top outlet. The MUB-K2 fans are delivered to 90 air direction airflow. MUB042 400DV-K2 450DV-K2 500DV-K2 Voltage/Frequency V/50 Hz 400 400 400 Phase ~ 3 3 3 Power at shaft W 370 750 1500 Current A 1,40 2,50 4,3 Maximum air flow m 3 /h 4050 5500 8500 R.p.m. min -1 1340 1405 1330 Max. temp. of transported air C 100 100 100 Max. ambient temp. C 40 40 40 Sound pressure level at 3 m * db(a) 49 52 56 Weight kg 59 64 70 Insulation class, motor F F F Enclosure class, motor IP 54 IP 54 IP 54 Motor protection STDT 16 STDT 16 STDT 16 Speed control, five-step Transformer RTRD 2 RTRD 4 RTRD 7 Speed control, five-step high/low Transformer RTRDU 2 RTRDU 4 RTRDU 7 Speed control, D/ two step 400V S-DT2 SKT S-DT2 SKT S-DT2 SKT Wiring diagram p. 11-17 17 17 17 * According to 20 m 2 Sabine A B C ød øe F MUB042 400 670 670 590 404 253 300 MUB042 450 670 670 590 454 286 300 MUB042 500 670 670 590 504 321 300 176

FGV p. 488 SRKG p. 488 UGS p. 488 MUB042 400DV-K2 Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 72 59 61 65 67 66 63 58 51 L wa Outlet db(a) 74 61 63 67 69 68 65 60 53 L wa Surrounding db(a) 56 43 45 49 51 50 47 42 35 Measuring point: q v = 0,56 m 3 /s, P s = 323 Pa MUB042 450DV-K2 Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 74 61 63 67 69 68 65 50 53 L wa Outlet db(a) 76 63 65 69 71 70 67 62 55 LwA SurroundingdB(A) 59 46 48 52 54 53 50 45 38 Measuring point: q v = 0,81 m 3 /s, P s = 325 Pa STDT p. 464 RTRD p. 455 MUB042 500DV-K2 Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 78 65 67 71 73 72 69 64 57 L wa Outlet db(a) 80 67 69 73 75 74 71 66 59 L wa Surrounding db(a) 63 50 52 56 58 57 54 49 42 Measuring point: q v = 1,40 m 3 /s, P s = 434 Pa RTRDU p. 455 S-DT2SKT p. 463 177

MUB062 560DV-K2-630D4-K2 Motor outside of the air stream Speed-controllable Modular system Integral thermal contacts Low sound level Maintenance-free and reliable All MUB-K2 fans have impellers with backward curved blades, manufactured from aluminium, and IEC standard motor, which can be speed controlled using frequency controller. Motors are outside the air stream. The casing consists of an aluminium frame with fiberglass reinforced plastic corners and double skin, galvanised steel panels with a 20 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions. With quick-lock access door. The MUB casing is equipped with a grease tray under the impeller and a protection guard at the motor side. An isolator switch is mounted on the casing. Motor protection by thermal contacts, to be connected to an external motor protection device. Standard execution, seen in airflow direction: service door left, top outlet. The MUB-K2 fans are delivered to 90 air direction airflow. MUB062 560DV-K2 630D4-K2 Voltage/Frequency V/50 Hz 400 400 Phase ~ 3 3 Power at shaft W 2200 4000 Current A 5,8 9,5 Maximum air flow m 3 /h 12000 16000 R.p.m. min -1 1420 1400 Max. temp. of transported air C 100 100 Max. ambient temperature C 40 40 Sound pressure level at 3 m * db(a) 57 69 Weight kg 132 137 Insulation class, motor F F Enclosure class, motor IP 54 IP 54 Motor protection STDT 16 STDT 16 Speed control, five-step Transformer RTRD 7 - Speed control, five-step high/low Transformer RTRDU 7 - Speed control, D/ two step 400V S-DT2 SKT - Wiring diagram p. 11-17 17 13 * According to 20 m 2 Sabine A B C ød øe F MUB062 630 800 800 720 635 407 321 MUB062 560 800 800 720 570 361 321 178

FGV p. 488 SRKG p. 488 UGS p. 488 MUB062 560DV-K2 Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 79 66 68 72 74 73 70 65 58 L wa Outlet db(a) 81 68 70 74 76 75 72 67 60 L wa Surrounding db(a) 64 51 53 57 59 58 55 50 43 Measuring point: q v = 2,25 m 3 /s, P s = 565 Pa MUB062 630D4-K2 Hz Tot 63 125 250 500 1k 2k 4k 8k L wa Inlet db(a) 87 74 76 80 82 81 78 73 66 L wa Outlet db(a) 89 76 78 82 84 83 80 75 68 L wa Surrounding db(a) 76 63 65 69 71 70 67 62 55 Measuring point: q v = 1,95 m 3 /s, P s = 911 Pa STDT p. 464 179