INLET DUCT FOR CISCO 6880 Part Number(s) DIRLC25S23W

Similar documents
INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W

Duct System for a Server or Switch Cabinet Mounted Cisco 4900M (CNLTD21B2)

PANZONE Overhead Distribution Racks

PANZONE Overhead Distribution Racks

Opticom Rack Mount Fiber Enclosures

PanView iq (PViQ) Fiber Tray

Universal Network Zone System Part Numbers: Z23U-****

Network Zone System Part Numbers: Z23N-***** Z23R-****

Network Zone System. Part Numbers: Z22N-****** Z22R-****

Z22C-** Preconfigured Network Zone System

Instructions for Wire Mesh Pulling Grips on Outside Plant and Indoor/Outdoor Fiber Optic Cable Best Practices

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

DPoE Power System. User Manual

Space Saving Cable Management Rack Systems

Shown on engine Locating plate for right camshaft 6 Slot in camshaft Inspect basic position of balancing shaft only engine 112

Dalamatic Cased Dust Filters Series DLM 15

STUD BRACKETS & TRACK

Installation Instructions Page 1 of 10

Cabinet and Rack Installation

PANDUCT Type NNC Halogen Free Metric Wiring Duct

Space Saving Cable Management Rack Systems

ES Series Enclosures Installation Instructions (UL /UL2416 ES Series Equipment Cabinet/Rack)

Dalamatic Cased Dust Collectors Series DLM 15

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

Installation Instructions

Check The Engine Valve Timing AR05.10 P 6858V

Cisco Nexus 7700 Switches Environment

AIR INDUCTION SYSTEM

Cabinet and Rack Installation

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Cabinet and Rack Installation

Cabinet and Rack Installation

1 CMP throttle stud, two 3/8" nuts, a 3/8" bolt and corrector plate) CMP R4 Universal Cable 1

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

FLEX-6000 Rack Mounting Bracket Installation Guide

Installing the ONS M6 Shelf

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

MDG78 Complete Dryer Assembly Piece Back Guard Assembly (gas and electric) Top Back Guard (gas and electric) Bottom Bac

Fig B34 Carbon Steel 'T' Type or Basket Type Strainers

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

GUIDELINES The following guidelines are recommended for the proper functioning and the maximum service life of the 630/710 series of connections. Fail

Installation instruction do88 Intercooler for SAAB 9-3 1,9 TTiD

CABINETS, RACKS, AND CABLE MANAGEMENT SOLUTIONS

Midmark Cabinet / Wall Light Installation

Patient Care Facility

Intentionally left blank

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

ES Series Enclosures Installation Instructions (UL /UL2416 ES Series Equipment Cabinet/Rack)

General Service Gaskets and Specialty Gaskets

Installation instruction do88 Intercooler for SAAB 9-3SS/SC 2,8 V6 Turbo

JBR MAZDASPEED

Cable Ladders with Troughs and Partitions

Transmission Connector Kit (Includes throttle stud, two 3/8" nuts, a 3/8" bolt and corrector plate)

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Maximum Motor Power 0.25 hp 0.19 kw Torque Range ft. lbs Nm. Torque Range ft. lbs Nm Non-Reversible

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Installation Instructions

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Installation Instructions :AUDI 8V RS3 : Page 1

Installation Manual v1.0: 10-Digit P/N: Aurora 3000 Turbo System L Powerstroke Ford

Ducted HEPA filter units for highly sensitive areas

P O B o x S t. L o u i s, M O P h o n e : ( ) ~ E m a i l : w m h u I t a o l.

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Hydraulic Power Supply and Motors Concept and Theory

APPLICATION OF STAR-CCM+ TO TURBOCHARGER MODELING AT BORGWARNER TURBO SYSTEMS

Company name: Created by: Phone: Note! Product picture may differ from actual product

Patient Care Facility

Company name: Created by: Phone: Date: Note! Product picture may differ from actual product

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

enmotion Recessed Automated Touchless Towel Dispenser Installation Instructions for New and Retrofit Construction

Installation Instructions

Note! Product picture may differ from actual product

STAR DAMPERS ASTRAL ACTUATOR (DA SERIES)

Installation, Operation and Maintenance Manual

Fire/combustion gas damper EKO-JBG

Auger / Bucket Elevator / Air Wash System

HAMMERLESS CHECK VALVE

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. A Hidden Power

UNIFLO Control Valve

Design and Application Details

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

MODERN TECHNOLOGY IN PUNCHING AND SHEARING

Chevrolet ZL1 Camaro Lingenfelter Air Intake Kit Installation Instructions (LSA engine)

Fire/combustion gas damper EKO-JBL

STANDARD SHAPES TROLLEY PARTS MANUAL

NCF fans 50 Hz. Protection class IP 55

ADVANCE ADAPTERS INC. P/N: VORTEC GEN. III V8 SQ. BOLT TJ WRANGLER MOTOR MOUNTS (WITH A/C)

Installing the Air Flow Regulator

2-Post Rack Mount Kit Installation Instructions

Study Report. McCredie-Overton Transmission Line Right-of-Way Analysis. City of Columbia, Missouri. prepared for the (S49)

PRODUCT INFORMATION BULLETIN

PMP Replacement For Gilbarco Monochrome QVGA Display

TECHNICAL DATA SHEET 400 Series Pneumatic Actuators

Motor-drive mechanism, type BUL. Technical guide

Repair Parts List DRYER MODEL NUMBER MDG27PCAAL. When requesting service or ordering parts, always provide the following information:

J-Pro Cable Support System


Design and Application Details

Transcription:

INLET DUCT FOR CISCO 6880 Part Number(s) DIRLC25S23W Panduit Corp. 2015 INSTALLATION INSTRUCTIONS For a Net-Access Legacy or Net- Access N-Type Switch Cabinet (CN*** or N***) 6880 Inlet Duct Component Guide Note: Has (2) Notches on the Top (1) Left Hand (1) Inlet Duct Box (1) Right Hand (2) Adjustable s (1) Side Duct Mounting (1) Side Duct Page 1 of 8

STEP 1 Placement (Legacy Cabinets Only) Due to physical constraints posed by the front-to-back beams on the Net-Access Legacy cabinet, there are certain areas of the cabinet that the device can not be mounted in when used in conjunction with this inlet duct. For Net-Access Legacy cabinets, front equipment rails need to be in full forward position and the rear equipment rails need to be 24.25" - 26.12" back. NOTES: Numbers-up RU numbering (#1 at bottom) assumed. 45 RU Net-Access CN*** Cabinet (Legacy) 42 RU Net-Access CN*** Cabinet (Legacy) RUs 41-45 RUs 38-42 Can Be RUs 25-40 Can Be RUs 25-37 RUs 19-24 RUs 19-24 Can Be RUs 3-18 Can Be RUs 3-18 RUs 1-2 RUs 1-2 Page 2 of 8

STEP 2 Placement (N-Type Cabinets Only) For Net-Access (N***) Cabinets, there are no device keep out areas. The only restriction on the switch placement is that 3 RU must be left open above the switch. For Net-Access (N***) cabinets, front equipment rails need to be in full forward position and the rear equipment rails need to be 24.25" - 26.12" back. NOTES: Numbers-up RU numbering (#1 at bottom) assumed. RUs 43-45 45 RU Net-Access N*** Cabinet RUs 40-42 42 RU Net-Access N*** Cabinet Can Be RUs 1-42 Can Be RUs 1-39 Page 3 of 8

STEP 3 Left / Right Hand Installation Using (2) #10-32 nuts, attach (1) adjustment bracket to the left hand bracket. Set adjustment bracket to fit equipment rail spacing. Using (2) #10-32 nuts, attach (1) adjustment bracket to the right hand bracket. Set adjustment bracket to fit equipment rail spacing. Attach the left hand and right hand brackets to the cabinet with (8) #12-24 screws and (8) #12 star washers. Equipment Rail Spacing Adjustment (2) #10-32 Nuts Left Hand (8) #12-24 Screws (8) # 12 Star Washers Right Hand Adjustment Equipment Rail Spacing (2) #10-32 Nuts Left Hand Page 4 of 8 Right Hand

STEP 4 Attaching Side Duct to Right Hand (Day 1 Installation) Slide the (2) threaded studs on the side duct into the (2) slots in the right hand bracket. Secure the side duct to the right hand bracket with (2) #10-32 nuts. (2) #10-32 Nuts Side Duct Right Hand Page 5 of 8

STEP 5 Attaching Side Duct to Right Hand (Day 2 Installation) From the Rear of the cabinet, slide the side duct into place with the (2) threaded studs on the side duct into the (2) slots in the right hand side bracket. Secure side duct to right hand bracket with (2) #10-32 nuts. Side Duct (2) #10-32 Nuts Right Hand Page 6 of 8

STEP 6 Attaching Side Duct B Secure side duct bracket to the cabinet with (2) #12-24 screws and (2) #12 star washers. Using (2) #10-32 nuts, attach side duct bracket to side duct. (2) #12-24 Screws Side Duct (2) # 12 Star Washers Page 7 of 8

STEP 7 Installing Inlet Duct Box Install the inlet duct box by sliding the box into the left hand and right hand brackets, along built in guide flanges and securing with (2) #10-32 nuts. Inlet Duct (2) #10-32 Nuts For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com E-mail: techsupport@panduit.com Phone: 866-405-6654 Page 9 of 9