Servo solenoid valves with positive overlap and on-board electronics (OBE)

Similar documents
Servo solenoid valves with positive overlap and on-board electronics

Servo solenoid valves with on-board electronics (OBE)

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Industrial Hydraulics FAQs

Pilot operated proportional directional valves

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Proportional flow control valve, with inductive position transducer

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC ±10 V)

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve, direct operated, decreasing characteristic curve

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Pressure reducing valve, direct operated

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

2-way proportional throttle valve for block installation

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Proportional flow control valve, 2-way version

Directional servo-valve of 4-way design

Proportional pressure reducing valve, pilot operated

3/3 servo directional control valve with mechanical position feedback

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure reducing valve, pilot operated

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Proportional pressure reducing valve, 3-way variant, pilot operated

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, directly operated, rising characteristic curve

4-way directional servo-valve

Supply pressure compensator, direct operated

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Proportional pressure relief valve, pilot operated

Directional servo-valve in 4-way design

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Flow sharing control block in mono block / sandwich plate design M6-22

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

3/2 and 4/2 directional seat valves with solenoid actuation

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Proportional pressure reducing valve of 3-way design

Flow sharing control block in mono block / sandwich plate design M6-15

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Proportional pressure reducing valve, pilot operated

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Flow sharing control block in sandwich plate design M7-25

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Throttle and throttle check valve

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

4-way directional servo valve Type 4WS.2E

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Double throttle check valve Type Z2FS 10

Throttle and throttle check valve

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

4/3 Proportional directional valve elements L85P5 with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Proportional flow control valve, with integrated pressure compensator

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

Check valve, pilot operated

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

Check valve, pilot operated

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

3/2 directional spool valve, direct operated with solenoid actuation

Pressure relief valve, pilot operated

Pressure reducing valve, pilot operated

Twin throttle check valve

Proportional directional valve, direct operated, with pq functionality

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Transcription:

Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Servo solenoid valves with positive overlap and on-board electronics (OBE) RA 2989/1.5 1/24 Model 4WRLE 1 35, symbols E./W. Nominal sizes 1, 16, 25, 35 Unit series 3X Maximum working pressure P, A, B 35 bar (576 PSI) T, X, Y 25 bar (3626 PSI) Nominal flow rate 5 1,1 l/min (13.2 29.6 GPM) [Δp 1 bar (145 PSI)] Overview of contents Contents Page Features 1 Ordering data and scope of delivery 2 Preferred types 3 Function, sectional diagram 3 Accessories 4 Control oil supply 4 Symbols 5 and 6 Technical data 7 to 9 On-board trigger electronics 1 Characteristic curves 11 to 15 Unit dimensions 16 to 19 Mounting hole configurations 2 and 21 Variants on request For standard applications Special symbols and characteristic curves with/without intermediate plates Features Pilot operated servo solenoid valves NG1 to NG35 with positive overlap, see symbols E./W. and characteristic curves Pilot valve NG6, with control piston and sleeve in servo quality Actuated on one side, 4/4 fail-safe position when switched off Control solenoid with integral position feedback and on-board valve electronics (OBE), calibrated at the factory Main stage with approx. 2-% overlap and position feedback Electronically compensated, calibrated overlap, see characteristic curve range ±.5-V Spool with linear travel, with anti-rotation element Flow characteristic S = Progressive NG16 and 25 with load tap C1/C2 Suitable for electrohydraulic controllers in production systems with more demanding requirements For subplate attachment, mounting hole configuration NG1 to ISO 441-5-5--94, NG16 to ISO 441-7-6--94, NG25 to ISO 441-8-7--94 and NG32 to ISO 441-1-8--94 Subplates as per catalog section, NG1 RE 4555, NG16 RE 4557, NG25 RE 4559 and NG32 RE 456 (order separately) Plug-in connectors to DIN 43563-AM6, see catalog section RE 88 (order separately)

2/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Ordering data and scope of delivery With on-board trigger electronics Nominal size 1 Nominal size 16 Nominal size 25 Nominal size 35 1) Symbols A B P T AC1B PC2T A B P T A B 4WRL E Z S J 3X H / G24 K A1 M * = E = 1 = 16 = 25 = 35 = E, E1 A B P T = E (Z), E1 (Z) AC1B PC2T = W, W1 A B P T = W (Z), W1 (Z) AC1B PC2T A B P T A B = E4 = W4 J = Further information in plain text M = NBR seals, suitable for mineral oils (HL, HLP) to DIN 51524 Interface for trigger electronics A1 = Setpoint input ±1 V Electrical connection K = without plug-in connector, with plug to DIN 43563-AM6 Order plug-in connector separately Control oil supply x, control oil outlet y No code= E = ET = T = x = external, y = external x = internal, y = external x = internal, y = internal x = external, y = internal Voltage supply of trigger electronics G24 = +24 V DC H = Highflow version (on request) 3X = Unit series 3 to 39 (installation and connection dimensions unchanged) Overlap compensation signal See characteristic curve range: ±.5-V Flow characteristic S = Progressive Nominal flow rate at 1 bar valve pressure difference Nominal size 1 = 5 or 85 l/min (13.21 or 22.45 GPM) 16 = 18 l/min (47.55 GPM) 25 = 35 or 43 l/min (92.46 or 113.6 GPM) 35 = 1,1 l/min (29.59 GPM) Z = With load tap C1/C2 P T P T Transitional symbols With symbol E1, E1(Z), E4, W1(Z), W4: P A: q v B T: q v /2 P B: q v /2 A T: q v 1) NG35 is a high flow version of the NG32, ports P, A, B and T have Ø 5 mm in the main stage. Contrary to the standard, ports P, A, B and T may be drilled to max. Ø 48 mm in the control block. These valves therefore provide higher flow rates Q A : Q B.

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 3/24 Standard types (available at short notice) Type 4WRLE- Material No. E, E1, E4, W, W1, W4 NG1 4WRLE1E 8SJ 3X/G24KO/A1M 81144 7 4WRLE1E 8SJ 3X/G24ETKO/A1M 81144713 4WRLE1E1 8SJ 3X/G24KO/A1M 8114471 4WRLE1E1 8SJ 3X/G24ETKO/A1M 81144715 4WRLE1E4 8SJ 3X/G24KO/A1M 81144714 4WRLE1W 5SJ 3X/G24ETKO/A1M 8114474 4WRLE1W 8SJ 3X/G24KO/A1M 8114472 4WRLE1W 8SJ 3X/G24ETKO/A1M 8114477 4WRLE1W1 8SJ 3X/G24KO/A1M 8114473 4WRLE1W4 8SJ 3X/G24KO/A1M 81144711 E (Z), E1 (Z), W (Z), W1 (Z), W4 NG16 4WRLE16EZ 18SJ 3X/G24ETKO/A1M 81144319 4WRLE16EZ 18SJ 3X/G24TKO/A1M 81144318 4WRLE16EZ 18SJ 3X/G24KO/A1M 8114435 4WRLE16E1Z 18SJ 3X/G24KO/A1M 8114436 4WRLE16WZ 18SJ 3X/G24KO/A1M 8114437 4WRLE16W1Z 18SJ 3X/G24ETKO/A1M 81144327 4WRLE16W1Z 18SJ 3X/G24KO/A1M 8114438 4WRLE16W4 18SJ 3X/G24ETKO/A1M 81144328 4WRLE16W4 18SJ 3X/G24KO/A1M 81144333 Type 4WRLE- Material No. E (Z), E1 (Z), E4, W (Z), W1 (Z), W4 NG25 4WRLE25EZ 35SJ 3X/G24KO/A1M 81144454 4WRLE25EZ 35SJ 3X/G24TKO/A1M 81144466 4WRLE25EZ 35SJ 3X/G24ETKO/A1M 81144481 4WRLE25E1Z 35SJ 3X/G24KO/A1M 81144455 4WRLE25E4 35SJ 3X/G24KO/A1M 81144459 4WRLE25WZ 35SJ 3X/G24KO/A1M 81144456 4WRLE25W1Z 35SJ 3X/G24EKO/A1M 81144476 4WRLE25W1Z 35SJ 3X/G24KO/A1M 81144457 4WRLE25W4 35SJ 3X/G24ETKO/A1M 81144471 4WRLE25W4 35SJ 3X/G24KO/A1M 81144472 W NG35 4WRLE35W 11SJ 3X/G24KO/A1M 8114454

4/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Function, sectional diagram Servo solenoid valve 4WRLE-1...35 EN 61-6-2 EN 61-6-3 see page 4 Pilot valve Position transducer Main stage Accessories, not included in scope of delivery Fastening screws f * Plug-in connectors 6P+PE, see also RE 88 NG1 4 x M6 x 4, DIN 912-1.9 2-91-151-29 NG16 2 x M6 x 45, DIN 912-1.9 2-91-151-211 4 x M1 x 5, DIN 912-1.9 2-91-151-31 NG25 6 x M12 x 6, DIN 912-1.9 2-91-151-354 NG35 6 x M2 x 9, DIN 912-1.9 2-91-151-532 KS 1-834-482-22 KS 1-834-482-26 MS 1-834-482-23 MS 1-834-482-24 KS 9 1-834-484-252 Testing and service equipment Test box type VT-PE-TB3, see RE 365 Test adapter 6P+PE type VT-PA-2, see RE 368

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 5/24 Control oil supply NG1, 25, 35 NG16 Pv X Tv Y 13 +.5 (.51 +.2 ) Tv Y Pv X P Plug T jk NG1...25 1 813 464 7 SW 3 NG35 1 813 464 1 SW 4 6 +1 (.24 +.4 ) 52 (2.5) 72 +1 (2.83 +.4 ) Type 3X A B G a b Symbol in detail X Type 3X E Type 3X ET Type 3X T P T Y A B G a b P T Y A B G a b P T A B G a b Pilot valve Main valve X P T No code = E = ET = T = x = external, y = external x = internal, y = external x = internal, y = internal x = external, y = internal Conversion The pilot valve can be supplied with oil both via ports X and Y (external) and from the main flow ducts P and T. In the basic version, the valve is equipped with the plugs j and k, i.e. X and Y are external. For valve versions with X and/or Y as internal, see ordering overview or carry out the conversion (see diagram above). When the control oil supply or outlet is changed, the part number must also be changed.

6/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Symbols in mid position E.. or W.. E W Spool valves with overlap With symbol E, leakage oil in the two work chambers A and B of the control piston results in a build-up of pressure in A or B, which then causes a connecting cylinder to drift out of position. In many cases, the W symbol is a better solution. With a setpoint of, the control piston moves into the overlapped mid position. In this mid position, pressure is then relieved from ports A and B with small openings to T. This also supports the function of external check valves. Flow in mid position leakage pressure relief NG1 6 (1.59) 5 (1.32) Q = f (Δ s)... ±25 % Δp x Q x = Q nom 5 bar l/min (GPM) 4 (1.6) 3 (.8) 2 (.53) 1 (.26) 25 2 15 1 5 5 1 15 2 25 % Δ s NG16 12 (3.17) 1 (2.64) l/min (GPM) 8 (2.11) 6 (1.59) 4 (1.6) 2 (.53) 25 2 15 1 5 5 1 15 2 25 % Δ s NG25 24 (6.34) 2 (5.28) l/min (GPM) 16 (4.23) 12 (3.17) 8 (2.11) 4 (1.6) 25 2 15 1 5 5 1 15 2 25 % Δ s NG35 6 (15.85) 5 (13.21) l/min (GPM) 4 (1.56) 3 (7.93) 2 (5.28) 1 (2.64) 25 2 15 1 5 5 1 15 2 25 % Δ s

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 7/24 Load tap C1/C2 To compensate for fluctuations in the load or supply pressure, proportional valves are combined with pressure compensators. The load is tapped through a shuttle valve for the NG1 and 35, and through two additional ports C1 and C2 for NG16 and 25 ( 4WRL and 4WRLE only). NG1, 35 The pressure compensator therefore always receives the correct pressure signal even in the event of negative load. When using pressure compensators, external control oil supply should always be selected. NG16, 25 Asymmetrical valve spool Q A : Q B = 2:1 The two throttle cross-sections of proportional directional control valves are usually symmetrical. In order to adapt to differential cylinders with different with asymmetrical metering notches are available. A comparison of the flow rates can be found in the product range overview Preferred types, characteristic curves. Valve spools in a differential circuit In order to produce differential circuits, valve spools with an additional 4th position are available (see diagram). It is sufficient to install a check valve in the consumer lines. In addition, a symbol (spool) with internal B-P connection is employed for certain branch-oriented solutions. However, we recommend that you consult the BRH Application Center with regard to these special symbols. As a rule, a simulation or knowledge of this type of system is required.

8/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Technical data General Construction Spool type valve, pilot operated Actuation Servo solenoid valve NG6, with position controller for pilot valve and main stage Type of mounting Subplate, mounting hole configuration NG1...35 (ISO 441-...) Installation position Optional Ambient temperature range C ( F) 2 +5 ( 4 +122) Weight kg ( NG1 8.7 (19.2) NG16 1.6 (23.4) NG25 18.4 (4.6) NG35 81 (178.5) Vibration resistance, test condition max. 25 g, shaken in 3 dimensions (24 h) Hydraulic measured with HLP 46, ϑoil = 4 C ±5 C (14 F ±41 F) Pressure fluid Hydraulic oil to DIN 51524 535, other fluids after prior consultation Viscosity range recommended mm 2 /s (SUS) 2 1 (93 464) max. permitted mm 2 /s (SUS) 1 8 (46 37) Pressure fluid temperature range C ( F) 2 +7 ( 4 +149) Maximum permissible degree of contamination Class 18/16/13 1) of pressure fluid Purity class to ISO 446 (c) Direction of flow See symbol Nominal flow at NG1 NG16 NG25 NG35 Δp = 5 bar (73 psi) per notch 2) l/min (GPM) 5, 8 (13.2, 21.1) 18 (47.6) 35 (92.5) 1,1 (25.6) Max. working pressure in P, A, B 35 (576) 35 (576) 35 (576) 35 (576) Max. pressure in X (ext.) 28 (461) Max. pressure in P (X = int.) 28 (461) Max. pressure in T (Y = ext.) bar (PSI) 25 (3626) Max. pressure in T (Y = int.) 25 (3626) Max. pressure in Y (ext.) 25 (3626) Min. control oil pressure of pilot stage 8 (116) Q max l/min (GPM) 17 (44.9) 45 (118.9) 9 (237.8) 3,5 (924.6) Q N pilot valve (supply pressure) Δp = 35 bar l/min (GPM) 2 (.53) 4 (1.6) 12 (3.17) 4 (1.57) Leakage of pilot valve at 1 bar Leakage of main stage Sb E at 1 bar Q N : Sb W, see graph on page 5 Static/Dynamic Overlap in mid position cm 3 /min (in 3 /min) l/min (GPM) <15 (9.2) <.25 (6.6) <18 (11.) <.4 (.11) <35 (18.3) <.6 (.16) <1,1 (61.) <1.1 (.29) 18 22 % of spool stroke, electrically adjustable for UD E ±.5 V Spool stroke, main stage ± mm (in) 4 (.16) 7 (.28) 1 (.39) 12.5 (.49) Control oil volume of main stage 1 % cm 3 (in 3 ) 1.1 (.7) 4.3 (.26) 11.3 (.69) 41.5 (2.53) Control oil requirement... 1 %, x = 1 bar (145 psi) l/min (GPM) 2.2 (.58) 4.7 (1.24) 11.7 (3.9) 15.6 (4.12) Hysteresis % <.1, scarcely measurable Manufacturing tolerance % ±5 (Q max) Response time for... 1 %, x = 1 bar (145 psi) ms <4 <8 <8 <13 Response time for... 1 %, x = 1 bar (145 psi) ms <15 <25 <25 <5 Switch-off behavior After electrical shut-off (pilot valve in fail-safe ) Main stage moves to spring-centered mid position (Sb E../W.. ) Thermal drift <1 % at ΔT = 4 C (14 F) Calibration At factory ±1 %, see flow curve Conformity EN 61-6-2 EN 61-6-3 1) The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and also extends the service life of components. For a selection of filters, see catalog sections RE 57, RE 576 and RE 581. Δp x 2) Flow rate at a different Δp qx = q nom 5 bar

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 9/24 Technical data Electric pilot valve NG6, valve with on-board electronics Cyclic duration factor % 1 Degree of protection IP 65 to DIN 45 and IEC 14434/5 Connection Plug-in connector 6P+PE, DIN 43563 Power supply Terminal A: Terminal B: -V Power consumption External fuse Input, Standard version Terminal D: U E Terminal E: Max. differential input voltage at V Test signal, Standard version Terminal F: U Test Terminal C: Protective conductor and screen Recommended cable Calibration 24 V DCnom min. 21 V DC/max. 4 V DC Ripple max. 2 V DC Solenoid 45 mm = 4 VA max. 2.5 A F Difference amplifier, R i = 1 kω... ±1 V V D B E B max. 18 V DC LVDT... ±1 V Reference V See pin assignment (installation conforms to CE) See pin assignment up to 2 m (65.6 ft) 7 x.75 mm 2 (.3 in 2 ) up to 4 m (131.2 ft) 7 x 1. mm 2 (.4 in 2 ) Overlap and P A at +8 V, calibrated at the factory, see valve characteristic curve Version: Standard Important Pilot operated servo solenoid valves with positive overlap perform their function in open or closed-loop-controlled axes and have approx. 2-% overlap when switched off. This condition does not constitute an active, safe basic position. For this reason, many applications require the use of external check valves or certain sandwich-mounted valves, which must be taken into account during the On/Off switching sequence.

1/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Connection For electrical data, see page 8 and Operating Instructions 1-819-929-83 Technical notes on the cable Version: Multi-wire cable Extra-finely stranded wire to VDE 295, Class 6 Protective conductor, green/yellow Cu braided screen Types: e.g. Ölflex-FD 855 CP (from Lappkabel company) No. of wires: Determined by type of valve, plug types and signal assignment Cable Ø: Outside Ø:.75 mm 2 to 2 m length 1. mm 2 to 4 m length 9.4... 11.8 mm Pg11 12.7... 13.5 mm Pg16 Important Voltage supply 24 V DC nom., if voltage drops below 18 V DC, rapid shutdown resembling Enable OFF takes place internally. Electrical signals emitted via the trigger electronics (e.g. feedback signal) must not be used to shut down safety-relevant machine functions! (See European Standard, Technical Safety Requirements for Fluid-Powered Systems and Components Hydraulics, EN 982.)

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 11/24 On-board trigger electronics Block diagram/pin assignment Version A1: U D E ±1 V Supply Supply zero Ref. zero* Setpoint ±1 V Feedback signal ±1 V Protective conductor Screen * Do not connect to supply zero Signal 4/3 WV Pin assignment 6P+PE Version A1: U D E ±1 V (R i = 1 kω)

12/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Characteristic curves measured with HLP-46, ϑ oil = 4 C ±5 C (14 F ±41 F) NG1 Q in l/min (GPM) 1 (26.42) 9 (23.78) 8 (21.13) 7 (18.49) 6 (15.85) 5 (13.21) 4 (1.57) 3 (7.93) 2 (5.28) 1 (2.64) Q A : Q B = 8: 8 l/min (21.13 GPM) Q in l/min (GPM) 1 (26.42) 9 (23.78) 8 (21.13) 7 (18.49) 6 (15.85) 5 (13.21) 4 (1.57) 3 (7.93) 2 (5.28) 1 (2.64) Q A : Q B = 8: 5 l/min (13.21 GPM) Q in l/min (GPM) 1 (26.42) 9 (23.78) 8 (21.13) 7 (18.49) 6 (15.85) 5 (13.21) 4 (1.57) 3 (7.93) 2 (5.28) 1 (2.64) Q A : Q B = 8: 5 l/min (13.21 GPM) ** Comp. U D E ±.5 V factory setting ±1 % ** Q P A at +8 V [U D E ] manufacturing tolerance Q max ±5 %

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 13/24 Characteristic curves measured with HLP-46, ϑ oil = 4 C ±5 C (14 F ±41 F) NG16 Q in l/min (GPM) 2 (52.83) 18 (47.55) 16 (42.27) 14 (36.98) 12 (31.7) 1 (26.42) 8 (21.13) 6 (15.85) 4 (1.57) 2 (5.28) Q A : Q B = 18: 18 l/min (47.55 GPM) Q in l/min (GPM) 2 (52.83) 18 (47.55) 16 (42.27) 14 (36.98) 12 (31.7) 1 (26.42) 8 (21.13) 6 (15.85) 4 (1.57) 2 (5.28) Q A : Q B = 18: 11 l/min (29.6 GPM) Q in l/min (GPM) 2 (52.83) 18 (47.55) 16 (42.27) 14 (36.98) 12 (31.7) 1 (26.42) 8 (21.13) 6 (15.85) 4 (1.57) 2 (5.28) Q A : Q B = 18: 11 l/min (29.6 GPM) ** Comp. U D E ±.5 V factory setting ±1 % ** Q P A at +8 V [U D E ] manufacturing tolerance Q max ±5 %

14/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Characteristic curves measured with HLP-46, ϑ oil = 4 C ±5 C (14 F ±41 F)) NG25 Q in l/min (GPM) 4 (15.67) 36 (95.1) 32 (84.54) 28 (73.97) 24 (63.4) 2 (52.83) 16 (42.27) 12 (31.7) 8 (21.13) 4 (1.57) Q A : Q B = 35: 35 l/min (92.46 GPM) Q in l/min (GPM) 4 (15.67) 36 (95.1) 32 (84.54) 28 (73.97) 24 (63.4) 2 (52.83) 16 (42.27) 12 (31.7) 8 (21.13) 4 (1.57) Q A : Q B = 35: 23 l/min (6.76 GPM) Q in l/min (GPM) 4 (15.67) 36 (95.1) 32 (84.54) 28 (73.97) 24 (63.4) 2 (52.83) 16 (42.27) 12 (31.7) 8 (21.13) 4 (1.57) Q A : Q B = 35: 23 l/min (6.76 GPM) ** Comp. U D E ±.5 V factory setting ±1 % ** Q P A at +8 V [U D E ] manufacturing tolerance Q max ±5 %

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 15/24 Characteristic curves (measured with HLP-46, ϑ oil = 4- C ±5- C) NG35 Q in l/min (GPM) 12 (317.) 11 (29.59) 1 (264.17) 9 (237.75) 8 (211.34) 7 (184.92) 6 (158.5) 5 (132.9) 4 (15.67) 3 (79.25) 2 (52.83) 1 (26.42) Q A : Q B = 11: 11 l/min (29.59 GPM) ** Comp. U D E ±-.5 V factory setting ±-1-% ** Q P A at +-8 V [U D E ] manufacturing tolerance Q max ±-5-%

16/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Characteristic curves measured with HLP-46, ϑ oil = 4- C ±5- C (14 F ±41 F) Response time x = 1 bar (145 psi) NG1 Open Close NG16 NG25 NG35

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 17/24 Unit dimensions NG1 nominal dimensions in mm (inches) 21 (8.27) 4 (1.57) Not included in scope of delivery 15 (.59) (1/4-2 UNC x 1-1/2 ) 39 (1.54) 39 (1.54) 81 (3.19) 49 (1.93) 77 (3.3) 12 (4.2) 167 (6.57) 56.5 (2.22) 46 (1.81) 15 (4.13) 197 (7.76) Mounting hole configuration: NG1 (ISO 441-5-5--94), see page 2 For subplates, see catalog section RE 4555 7 (2.76) 5 (.2) 8 (.31) 32.1/1 mm.4/4. in. (R max 4) Required surface finish of the mating piece

18/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Unit dimensions NG16 nominal dimensions in mm (inches) 17 (.67) 21 (8.27) 15 (.59) Not included in scope of delivery 13 (.51) 34 (1.34) 25 (.98) Ø3 (.12) 77 (3.3) 3 (1.18) 15 (5.9) 225 (8.56) 32 (11.89) (1/4-2 UNC x 1-3/4 ) (3/8-16 UNC x 2 ) 46 (1.81) 119 (4.69) 212 (8.35) 95 (3.74) 3 (.12) Mounting hole configuration: NG16 (ISO 441-7-6--94), see page 2 For subplates, see catalog section RE 4557 92 (3.62) 32.1/1 mm.4/4. in. (R max 4) Required surface finish of the mating piece

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 19/24 Unit dimensions NG25 nominal dimensions in mm (inches) 64 (2.52) 21 (8.27) 15 (.59) Not included in scope of delivery 13 (.51) 43 (1.69) Ø13 18 (.51) Ø6 (.24) 77 (3.3) 57 (2.24) (.71) 19 (7.48) 35 (12.1) 382 (15.4) 46 (1.81) (1/2-13 UNC x 2-1/4 ) 149 (5.87) 242 (9.53) 125 (4.92) 43 (1.69) 6 (.24) Mounting hole configuration: NG25 (ISO 441-8-7--94), see page 21 For subplates, see catalog section RE 4559 118 (4.65) 32.1/1 mm.4/4. in. (R max 4) Required surface finish of the mating piece

2/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Unit dimensions NG35 nominal dimensions in mm(inches) 21 (8.27) 15 (.59) 6 (2.36) Not included in scope of delivery 13 (.51) 37 (14.57) 29 (1.14) 49 (1.93) 43 (1.69) Ø21 (.83) 225 (8.56) 6 (2.36) Ø6 (.24) 5 (.2) 9 (3.54) 74 (2.91) 69 (2.72) 32 (12.6) 461 (18.15) (3/4-1 UNC x 3-1/2 ).1/1 mm.4/4. in. 32 (R max 4) Mounting hole configuration: NG32 (ISO 441-1-8--94), see page 21 For subplates, see catalog section RE 456 Required surface finish of the mating piece

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 21/24 Mounting hole configurations nominal dimensions in mm (inches) NG1 ISO 441-5-5--94 1) Deviates from standard 2) Thread depth: Ferrous metal 1.5 x Ø* Non-ferrous 2 x Ø * (NG1 min. 1.5 mm [.41 in.]) X Y Ø P A T B F1 F2 F3 F4 X Y R 27 (1.6) 6.3 (.25) 1.5 1) (.41) 16.7 (.66) 21.4 (.84) 1.5 1) (.41) 3.2 (.13) 32.5 (1.28) 1.5 1) (.41) 37.3 (1.47) 21.4 (.84) 1.5 1) (.41) () () 54 (2.13) () 54 (2.13) 46 (1.81) () 46 (1.81) 8 (.31) 11 (.43) M6 2) M6 2) M6 2) M6 2) 6.3 (.25) 62 (2.44) 11 (.43) 6.3 (.25) 5.8 (2.) 32.5 (1.28) 1.5 1) (.41) NG16 ISO 441-7-6--94 1) Deviates from standard 2) Thread depth: Ferrous metal 1.5 x Ø Non-ferrous 2 x Ø X Y Ø P A T B L X Y G 1 G 2 F 1 F 2 F 3 F 4 F 5 F 6 34.1 18.3 65.9 76.6 88.1 76.6 18.3 11.6 11.6 34.1 (1.34) (.72) (2.59) () (3.2) (3.47) (3.2) (.72) () (4.) (4.) () (1.34) 5 (1.97) 14.3 (.56) 1) 2 (.79) 55.6 (2.19) 2 1) (.79) 14.3 (.56) 2 1) (.79) 55.6 (2.19) 34.9 (1.37) 2 1 (.79) ) 6.3 (.25) 15.9 (.63) 6.3 (.25) 57.2 (2.25) 6.3 (.25) () 4 (.16) 69.9 (2.75) 4 (.16) () () 69.9 (2.75) 69.9 (2.75) 1.6 (.6) 5 (1.97) 71.5 (2.81) M1 2) M1 2) M1 2) M1 2) M6 2) M6 2)

22/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Mounting hole configurations nominal dimensions in mm (inches) NG25 ISO 441-8-7--94 1) Deviates from standard 2) Thread depth: Ferrous metal 1.5 x Ø Non-ferrous 2 x Ø P A T B L X Y G 1 G 2 F 1 F 2 F 3 F 4 F 5 F 6 X 77 (3.3) 53.2 (2.9) 29.4 (1.16) 1.8 (3.97) 5.6 (.22) 17.5 (.69) 112.7 (4.44) 94.5 (3.72) 29.4 (1.16) () 13.2 (5.13) 13.2 (5.13) () 53.2 (2.9) 77 (3.3) Y 17.5 (.69) 74.6 (2.94) 17.5 (.69) 74.6 (2.94) 46 (1.81) 73 (2.87) 19 (.75) 4.8 (.19) 92.1 (3.63) () () 92.1 (3.63) 92.1 (3.63) () 92.1 (3.63) Ø 25 1) (.98) 25 1) (.98) 25 1) (.98) 25 1) (.98) 11.2 (.44) 11.2 (.44) 11.2 (.44) 7.5 (.3) 7.5 (.3) M12 2) M12 2) M12 2) M12 2) M12 2) M12 2)

RA 2989/1.5 4WRLE 1 35, symbols E/.W. Industrial Hydraulics Bosch Rexroth Corp. 23/24 Mounting hole configurations nominal dimensions in mm (inches) NG32 ISO 441-1-8--94 1) Deviates from standard (NG35) 2) Thread depth: Ferrous metal 1.5 x Ø Non-ferrous 2 x Ø X Y Ø P A T B X Y G 1 G 2 F 1 F 2 F 3 F 4 F 5 F 6 114.3 (4.5) 35 (1.38) 48 1) (1.89) 82.5 (3.25) 123.8 (4.87) 48 1) (1.89) 41.3 (1.63) 35 (1.38) 48 1) (1.89) 147.6 (5.81) 123.8 (4.87) 48 1) (1.89) 41.3 (1.63) 13.2 (5.13) 11.2 (.44) 168.3 (6.63) 44.5 (1.75) 11.2 (.44) 147.6 (5.81) () 7.5 (.3) 41.3 (1.63) 158.8 (6.25) 7.5 (.3) () () 19.5 (7.5) () 19.5 (7.5) 158.8 (6.25) () 158.8 (6.25) 76.2 (3.) () 114.3 (4.5) 158.8 (6.25) M2 2) M2 2) M2 2) M2 2) M2 2) M2 2)

24/24 Bosch Rexroth Corp. Industrial Hydraulics 4WRLE 1 35, symbols E/.W. RA 2989/1.5 Notes Bosch Rexroth Corp. Industrial Hydraulics 2315 City Line Road Bethlehem, PA 1817-2131 USA Telephone (61) 684-83 Facsimile (61) 694-8467 www.boschrexroth-us.com This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties. The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging.