Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Similar documents
ULTRAVIOLET STERILIZER

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Aqua Ultraviolet Ultima II Filter Instruction Manual (For Units Up To 30, 000 Gallons)

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Installation, Operating and Maintenance instructions for Hydro-Air pumps

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

StormPro BA Series Sump Pump

Power. On Your Terms.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

10 Year Limited Warranty

SUNC3000 / Item #40885

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL Spa & Jetted Bathtub Pump

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Aqua Ultraviolet Ultima II Filter Instruction Manual (For Units Up To 30,000 Gallons)

ESE Series Cast Iron Sewage Pumps

PVI 60KW, PVI 82KW, PVI 95KW

StormPro BCV400 Sewage Ejector Pump

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Illumifalls Patio Pond

HALLMARK INDUSTRIES INC

SUPER PUMP OUT SYSTEM

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

PRE-PLUMBED SEWAGE SYSTEM

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

2-Speed Pumps Item #s 7813, 7814, 7818 & 7819

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Submersible Pond Pump with UV 800 Gallons Per Hour

Artesian2 Owners Manual

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Submersible Waterfall Pump 1200 Gallons Per Hour

Premium Pond Pump 330 Gallons Per Hour

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

OWNER S MANUAL Swimming Pool and Spa Pump

Pressurized Bead Filters

TPAK Series COOLANT PUMP

Marlow Series Cast Iron Swimming Pool Pumps

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

ArtesianPro Owners Manual

Operating and Installation Instructions

FADE Series Wall Axial Fans

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Jacuzzi. Magnum, RC, LR, Cygnet E-1451 Owner s Manual

Artesian Owners Manual

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Pressurized Pond Filter Up to 850 gallons

Premium Waterfall Pump 1200 Gallons Per Hour

TPHK Series Immersible Pump

SUBMERSIBLE SUMP PUMPS

Unilift KP 150, KP 250, KP 350

THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

DISCOVER ADVANCED ENERGY SYSTEM - AES WARRANTY POLICY

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

SUBMERSIBLE SWIMMING POOL DRAINER

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

WARNING. Laser light is extremely bright and can potentially cause permanent eye damage or interfere with critical operations if improperly used.

Parkit360 Force. Owner s Manual V2.6.2

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

8000 / 10,000 / 12,000

Owners Manual: - Pumps

SUBMERSIBLE SUMP PUMPS

PR 20/20. WARNING Buyer/User assumes all responsability for safety and proper use not in accordance with the directions and sately labels.

Raydot LLC 24 Actuator (115 VOLT)

Installation Instructions / Warranty. Citterio 39115XX1

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

SUPERPLUS WATER FILTRATION SYSTEM

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

ActuLink ABS Module - ABS-MOD-400

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

G500REC Manual Covering System for Containers

Container Fountain Kit with LED Light

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

GARDEN HOSE UTILITY PUMP

Artesian2 Owners Manual

gamma uv Aquarium Ultraviolet Sterilizers

SELF PRIMING CHEMICAL SERVICE PUMPS

Artesian2 Owners Manual

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

TPHK Series Immersible Pump

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Pump Installation and Service Manual HRS Hydromatic Retractable System

SPC-PANEL Simplex, Single Phase Pump Control Panel

MetroPrime 22MPC Self-Priming Centrifugal Pump

Fission. Nano-Protein Skimmer. Instructions for Model#8100

Installation & Operators Manual

ArtesianPro Owners Manual

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

SHALLOW WELL JET PUMP

Natural Fiber Planter Fountain

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

DC to AC Power Inverters

Transcription:

TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Sunami Warranty Aqua Ultraviolet products are warranted against failure due to defects in materials and/or workmanship during the warranty period. This warranty covers defects occurring under normal use and applies to the original retail purchaser and may not be transferred. The warranty and remedies set forth herein are conditional upon proper storage, installation, use, maintenance and conformance with the applicable use. It will be based upon Aqua Ultraviolet s discretion as to whether the defects are of manufacturing origin. This warranty does not apply to appearance or accessory items. This warranty does not include damage due to shipping and handling, transportation, unpacking, set up, installation, improper maintenance, abrasives, corrosion and /or electrolysis, incorrect line voltage, modification, abuse, misuse, neglect, accident, fire, flood, lightning, acts of God or repair or replacement of parts supplied by any other than Aqua Ultraviolet. Any oral statements about this product made by the seller, the manufacturer, their representatives or any other party does not constitute warranties and shall not be relied upon by the user and are not part of this contract. Neither the seller nor the manufacturer shall be liable for any injury, loss or damages, direct, incidental or consequential including but not limited to lost profits, lost sales, injury, inability to use the product and the user agrees that no other remedy is available. Before installing, the user shall determine the suitability of the product for their intended use and the user shall assume all risk liability whatsoever in connection therewith. To validate this warranty, mail the enclosed warranty card within 10 days of purchase along with proof of purchase (copy of sales receipt). Warranty Period: Complete Unit: One year from the date of purchase or 18 months from manufacturing date. Limitations: Warranty does not cover any malfunction from improper installation (we recommend that a licensed electrician install your system to the specifications outlined in this owners guide). Warranty only applies to the original end user and is not transferable. Warranty does not cover repairs done by anyone other than Aqua Ultraviolet. Warranty is void if system is not plugged into a G.F.C.I. (Ground Fault Current Interrupter). Warranty may not be modified by verbal statements by Aqua Ultraviolet, distributors, retailers, their agents or any other party. Warranty covers the repair or prorated replacement of the Aqua Ultraviolet products. Aqua Ultraviolet denies all liability for any other loss including but not limited to loss of equipment, income, livestock or personal injury. Warranty is voided by the following: Product labels defaced or removed. Housing has been painted. Product is improperly installed or maintained by user or agent. Product abused, misused or damaged by user or their agent. Product damage caused by electrical surges, electrical spikes, electrical brown outs or improper voltage. Electrical cord has been cut. Unit was run without water. Use of Anything other than parts approved by Aqua Ultraviolet. Any implied warranty granted under state law including warranties of merchantability or fitness for a particular purpose are limited to one year from the date of purchase or 18 months from the date of manufacture or as otherwise stated in the above warranty. Aqua Ultraviolet is not responsible for direct, indirect, incidental or consequential damages. Some states do not allow limitations on how long an implied warranty lasts and/or does not allow the exclusions or limitations of incidental damages so the above limitation and exclusion may not apply to you. This warranty gives you special legal rights and you may also have other rights that vary from state to state. 1

Warranty Returns or Repair Returns: Please call Aqua Ultraviolet at (800) 454-2725 for a Return Merchandise Authorization (RMA) number. You must have a valid RMA from an Aqua Ultraviolet customer service representative before sending any product in for warranty or repair. Please have your serial number, date of purchase and product type available when calling for an RMA number. All warranty returns or repair returns must come freight prepaid with an RMA number clearly marked on the outside of the box. All other returns will be refused. Aqua Ultraviolet will not be liable for any shipping cost to return warranty or repair items. Include a note in the box with your RMA number, name, address, daytime phone number and brief description of the reason for return or repair. Be sure to return product in the same packing or similar packing and insure the package (we recommend sending it UPS). If you do not have or can t locate proper packaging, please call our customer service department and we will send you packaging for a minimal charge. Aqua Ultraviolet shall not be responsible for damage or loss done by the shipper. Nor shall Aqua Ultraviolet be responsible for merchandise that arrives damaged due to improper packaging. All claims for loss and damage must be filed by the customer with the shipper. If the unit is found to be out of warranty we will contact you with the cost of repair. Your authorization is required prior to making any repairs. IMPORTANT INFORMATION WE CAN HELP YOU Returning this product is expensive and time consuming for you, your retailer and for us, the manufacturer. Should you encounter any problems with your product, please call our toll free HELP line for assistance 1-800-454-2725. PLEASE DO NOT return your product to the store! Your dealer or distributor cannot offer any warranty work or exchanges. In the US please call TOLL FREE 1-800-454-2725 (951) 296-3480 Outside the U.S. THANK YOU!

Sunami Installation Instructions Please read this manual BEFORE installing the pump. FIGURE 1 - Pump Unit Sunami Installation Instructions INSTALLATION LOCATION GENERAL This is a self-priming pump, which means that it can raise water through a dry suction line without using valves, provided the pump case and strainer body are full of water before the motor is started. Nevertheless, we recommend the use of a swing check valve in the suction pipe, at or below water level. This arrangement makes the initial priming easy, and then keeps the suction pipe primed at all times. The pump is moulded from lightweight, glass-reinforced thermoplastic material which eliminates all potential corrosion problems. In addition, all surfaces in contact with water passing through the pump are insulated from the electric motor. An extension of the impeller hub forms an insulating sleeve over the motor shaft and carries the mechanical shaft seal. The strainer body is capped with a transparent cover, secured by a screw-on RING-LOK that provides quick and easy access for cleaning the strainer basket. TABLE 1 - List of Models Sunami Pumps: Full Load Amps 110 Volt Full Load Amps 220 Volt GPM/GPH Sunami 1/3 hp 4.36 100 GPM/6000 GPH Sunami 3/4 hp 5.81 120 GPM/7200 GPH Sunami 3 hp 16.3 183 GPM/11000 GPH Sunami 4 hp 16.3 194 GPM/11640 GPH Sunami 5 hp 19.8 275 GPM/16500 GPH All Information Based on 10ft Of Head Pressure Locate the pump as close to the pond as possible, preferably in a dry, shaded, well-ventilated area. Install the pump at or below deck level. If this is not possible, choose the lowest available elevation. This simplifies priming, and adds to the pressure developed by the pump. Prepare a hard, level surface that is large enough to accommodate the pump and the associated equipment. Bear in mind the following: 1. drainage 2. ventilation of the motor; 3. access for servicing and winterizing the equipment 4. protection of the equipment from the elements. GENERAL INSTALLATION INFORMATION The pumps comes with 3" slip connectors. The 1/3 and 3/4 HP models include a 2" reducer. Never use a suction pipe smaller than the pump connection. Keep the piping as simple as possible. Avoid connecting an elbow directly to the pump inlet (use a length of straight pipe to allow a proper entry for the water). Keep as much of the suction pipe as possible below the water level of the pond because this will reduce the priming time, but arrange the pipe to rise continuously toward the pump to prevent high spots that could form air pockets. Support the pipes independently so that they place no strain on the pump. Install swing type check valves and unions in the pump suction and pond return lines close to the filter system for convenient servicing of the equipment. These valves are essential if the equipment is installed below deck. Keep the check valve in the suction line fully open during operation, and make sure that its gland is kept tight to prevent the entrance of air around the valve stem. Take care during installation to keep the pipes clean. Apply pipe sealant to all male threads, Teflon tape is recommended, and make sure that the suction system is absolutely airtight. Use of thread sealants other than Teflon tape may permanently damage the threads on the pump causing leaks. Do not use any lubricant. 3

Sunami Installation Instructions ELECTRICAL CONNECTIONS Check that the information on the nameplate of the electric motor corresponds the power supply to be used. Employ a competent electrician to ensure the wiring installation is made in accordance with Electrical Code. Every motor requires a fused disconnect switch or circuit breaker. A SINGLE-PHASE MOTOR has built-in thermal overload protection. OPERATION Note: See Figure 2 for pictures of individual parts. 1. Remove the strainer cover from the strainer basket and fill the pump completely with water. Replace the cover. CAUTION: Do not over-tighten the strainer RING- LOK ; hand tighten only. DO NOT RUN THE PUMP WITHOUT WATER. Sunami Maintenance CAUTION - ALWAYS DISCONNECT POWER BEFORE DOING ANY PUMP MAINTENANCE CLEANING THE STRAINER BASKET Switch off the power. Unscrew strainer RING- LOK counter clockwise and remove the strainer cover from the strainer basket then lift it out. Clean and replace the basket. Take care to seat the basket properly. Clean the 0-ring and 0-ring seats on the cover and strainer. Refit the cover and strainer RING-LOK - hand tighten only. Put the pump back into operation. Do not use any lubricant. DRAINING Remove the two drain plugs. Note that the valves in the suction and return lines must be open to allow complete draining of the pump. Other provisions may be necessary for draining the filter, heater, and pipe lines. 2. Start the pump. If the pump fails to produce a full flow of water within four or five minutes, switch off the power and repeat Step 1. If the pump still fails to work, check for air leaks at the strainer cover, suction line connections, and valve stem glands before repeating Step 1. CAUTION - DO NOT OPERATE THE PUMP WITH CLOSED SUCTION OR DISCHARGE VALVES. 3. After about ten minutes of operation, check the pond return fittings for air bubbles. A continuous flow of air indicates leaks in the suction line. Locate and correct any leaks immediately. CAUTION - DO NOT RETIGHTEN STRAINER RING-LOK DURING OPERATION. CONTROLLING THE OUTPUT Keep the check valve in the suction line fully open during operation. Should it be necessary to control the output, use a valve in the return line. 4

Sunami Parts Diagram FIGURE 2 - Components Strainer Ring-lok Strainer Cover O-ring Flapper Strainer basket Motor Ring-lok Inlet Outlet Diffuser Square Gasket Eye Seal Screws Impeller Shaft Seal Seal Housing Bracket O-ring Cap Screws 4x Posi-lok Flinger Motor Sunami Pump Housing Body Base Drain Plug Gaskets Drain Plugs Motor Support 5

Sunami Installation Instructions Trouble-Shooting MOTOR DOES NOT START: Disconnect switch or circuit breaker in OFF position Fuses blown or thermal overload open Locked motor shaft Motor windings burned out Defective starting switch inside single-phase motor Disconnected or defective wiring MOTOR DOES NOT REACH FULL SPEED: Low voltage Motor windings connected for wrong voltage MOTOR OVERHEATS (protector trips): Low voltage Motor windings connected for wrong voltage Inadequate ventilation. PUMP DELIVERS NO WATER: Pump not primed Closed valve in suction or discharge line Leakage of air into suction system Impeller plugged. LOW PUMP CAPACITY: Valve in suction or discharge line partly closed Suction or discharge line partly plugged Suction or discharge line too small Pump running at reduced speed (see above) Plugged basket in skimmer or strainer basket Dirty filter Impeller plugged. LOW PUMP PRESSURE Pump running at reduced speed (see above) Discharge valve or inlet fittings opened too wide HIGH PUMP PRESSURE Discharge valve or inlet fittings closed too much Return lines too small Dirty filter NOISY PUMP AND MOTOR Plugged basket in skimmer or strainer basket Defective motor bearings Valve in suction line partly closed Suction line partly plugged Pump not supported properly LEAKAGE OF WATER AT SHAFT Shaft seal requires replacement AIR BUBBLES AT INLET FITTINGS Leakage of air into suction line at connections or valve stem Cover of strainer basket not airtight Restriction in suction line Low water level in pond AIR BUBBLES IN STRAINER BASKET If an air bubble persists in the strainer basket, but no air bubbles are present at the pond s inlet fitting, do not be concerned. Occasionally, air is not completely flushed from the strainer of Sunami pumps. IF THE RECOMMENDATIONS IN THE TROUBLESHOOTING PORTION OF THIS MANUAL DO NOT SOLVE YOUR PARTICULAR PROBLEM(S), PLEASE CONTACT AQUA ULTRAVIOLET FOR ADDITIONAL SUPPORT Aqua Ultraviolet 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com 6

121710 A11O48 TM