Control solutions Biofloor

Similar documents
AXT201, 211: Thermal actuator for unit valves, with stroke indicator

AXS 215S: Continuous actuator for unit valves, with stroke indicator

Control Solutions Biofloor

AKM 105, 115: Rotary actuator for ball valve

VA-707x. Thermal Valve Actuators. Product Bulletin. Low and line voltage models available

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

HERZ Electronic room thermostat analog and digital

Overview of types. Technical data

Suitable to Johnson Controls and almost all of terminal unit valve on the market

Electrothermal actuators

HERZ Motorised Actuator

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

BUE: 3-way flanged valve, PN 16/10 (el.)

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

See «Overview of types»

AVM 105, 115: Valve actuator

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

AVM 215S-R: Valve actuator with SAUTER Universal Technology (SUT)

BQE: 3-way flanged valve, PN 16

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Power consumption In operation At rest For wire sizing

Electrical Actuators

Electrothermal actuators

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Overview of types. Technical data. Safety notes

Pushing 1) force. Motor Spring [N] [kg]

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

BUD: 3-way flanged valve, PN 6 (pn.)

AVP : Pneumatic valve actuators

AVM321, 322: Actuator SAUTER vialoq AVM 1000

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing

24 V AC/DC, -10%..+20%, 0-60Hz. 250 ma for max 2 min

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

Elektric actuator MC50/24-C

Cooling system components, removing and installing

Power consumption In operation At rest For wire sizing

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

Premounted Midi Shunts

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

OPERATING INSTRUCTIONS

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Cooling system components, removing and installing

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people.

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

VUD: 2-way flanged valve, PN 6 (pn.)

Electromotoric Actuators

EMO TM. Actuators High performance proportional actuator For modulating control

22C, 22CX, 22CX5, 26LC Series

MANIFOLDS & WATER TEMPERATURE CONTROL

Actuators for air dampers and control valves of oil burners

2-position electric actuators with Ball valves VBZ ½...11/4

Actuators for modulating control AME 110 NL, AME 120 NL

Power consumption In operation At rest For wire sizing

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Electromotoric Actuators

Power consumption In operation At rest For wire sizing

Technical data. Safety notes

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Power consumption In operation At rest For wire sizing

Fire and Smoke Damper Actuator product overview

Actuators for air dampers and control valves of oil burners

A44 W0...W2: Motorised actuator

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Actuator LA27 HOMELINE Analogue. Data sheet LINAK.COM/HOMELINE

AVP : Pneumatic valve actuators

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

J3C-H20 25Nm Smart Electric Valve Actuator

Features. 15 s 20 s 30 s. Heat Humidity Cold Vibration Material Housing Cover Colour Weight

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Pressure Sensors. for liquid and gaseous media

Electromotoric Actuators

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Actuators for small valves

S1024-2POS / S POS S2024-2POS / S POS

Actuators for air dampers and control valves of oil burners

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

NV Direct Coupled Globe Valve Actuator

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Operating Instructions. Angle Seat Control Valve. Type 7020

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B

Transcription:

ACTUONOFF Actuator ON/OFF Normally Closed for valves and manifolds Application Actuation of common valves, for example Comap thermostatic valves for radiators, Ballorex Dynamic valves and underfloor heating manifolds. For controllers with a switching output, 2-point control quasi-continuous control with 'pulse-pause' signal, in combination with intelligent unitary control systems. Advantages Easy to fit onto the valve using the Low-Force- Locking (LFL) connector; Fitted to valve via M30 x 1.5 or M28 x 1.5 thread with automatic adaptation Pushing force up to 90 N With 230 V or 24 V thermal expansion element Large, tangible and visible position indicator NC (normally closed) Silent Maintenance-free Models Item code C430012001 C430013001 C430014001 C430015001 Description Actuator ONOFF NC 230V M28 Actuator ONOFF NC 24V M28 Actuator ONOFF NC 230V M30 Actuator ONOFF NC 24V M30 Description Housing made of high-quality, selfextinguishing plastic, pure white (RAL 9010) or jet black (RAL 9005), high-gloss finish (fire protection according to EN 60695-2-11, EN 60695-10-2). Connected to valve with plastic bayonet connection. Bayonet nuts for connection to popular valves with threads M30 x 1.5 (black, included) or M28 x 1.5 (grey, included). Including white or black power cable, standard length 0.8 m PVC or halogen-free, Ø 0.5 mm². Run time for 'warm-up' for 4.5 mm stroke at 21 C: min. 3.5 minutes (230 V), min. 4.5 minutes (24 V) Installation position: any, including upsidedown 00688_2015-10_ENG 1

Technical features Power supply 230V ~±15 % 50...60 Hz 24V ~/= ±20 % 50...60 Hz Power consumption during operation 2,5 W 3 W Activation power Approx. 40 W / 40VA Approx.. 40 W / 40VA Activation current 150 ma 150 ma Closing force in closing-dimension range (8,5 13,5 mm) Min. run-time 84 102 N +/- 5N 3,5 min Technical data Max. stroke (mm) 4,5 mm Closing force 90 N ±5 % Warm-up time 4,0 min Permitted ambient conditions Operating temperature 0...50 C Storage and transport temperature -25 +70 C Max. operating temperature (at valve) Weight Humidity, no condensation 100 C max < 85 % HR 0,18 kg Protection type IP 54 (EN 60730-1, -2, -14) Protection class II (EN 60730-1) III (EN 60730-1) Electrical safety 2006/95/EC EN 60335-1 - EMC Directive 2004/108/EC EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 / EN 61000-6-4 00688_2015-10_ENG 2

Description du fonctionnement The actuator has an electrically heated expansion element which transfers its stroke directly to the attached valve. It works silently and is maintenance-free. If, when it is cold (ambient temperature of about 21 C), the heating element is turned on, the valve begins opening after a warming-up time of about 1.5 min (230 V and 24 V versions). After an additional period of approx. 2.5 min. (230 V) or 3 min. (24 V), the valve has carried out a stroke of 4.5 mm. If the heating element is turned off, the expansion element cools, and the valve is closed by spring force. Quasi-continuous control is achieved by using a 'pulse-pause' timing signal, which causes a periodic open/closed position. Run-time behaviour with a switching cycle of 10 minutes The runtime behaviour for the 230 V version is slightly shorter than the 24 V version, taking 2.5 min. (to achieve a stroke of 4.5 mm). Intended use This product is only suitable for the purpose intended by COMAP, as described in the Description of operation section. All related product documents must also be adhered to. Changing or converting the product is not admissible. 00688_2015-10_ENG 3

Control with thermal actuator Controller type For control with ACTUONOFF, there are basically two options: the quasi-continuous and discontinuous (2-point) controller. The quasi-continuous controller can be used whenever the section has linear behaviour, as is usually the case with room temperature control. The control performance using a quasi-continuous controller is better than with a discontinuous controller. Discontinuous controllers (2-point) are recommended for control of non-linear sections. Continuous control is not possible with ACTUONOFF actuators Position control The ability to move to any desired position of the ACTUONOFF actuator cannot be ensured with a controller. Only the actuator positions extended and retracted are ensured with a controller, so this actuator is also called a 2-point actuator. Energy limiter The ACTUONOFF can consume more energy than needed for opening. The result is that the cooling and thus the closing time are increased unnecessarily. There should be an element between the controller output terminal and the actuator that ensures that the supplied energy is limited. Reduction of the supplied energy helps shorten the closing time. This element is called an energy limiter and is independent of the controller parameters. The only dependency arises through the ambient temperature of the ACTUONOFF. Consequently, fixed parameters can be set for the energy limiter and used un-changed for each controller setting. NC version (normally closed) After the actuator has been installed, the VUL/BUL valves or normal commercial radiator valves are closed when idle. When power is applied to the actuator, the actuator spindle retracts, so the valve stem extends and opens the valve. Valve status when actuator is without power: closed. Closing dimension definition - NC version (normally closed) The closing dimension of a valve is the distance between the face of the stem (pushed in with pre-tension of < 100 N) and contact surface of the lower thread. The actuator or the bayonet nut sup-ports itself on this surface. 00688_2015-10_ENG 4

Installation Thanks to the Low-Force-Locking (LFL) technology, no force is needed in order to fit the actuator to the valve. o If the actuator is removed from the valve, the closing dimension and the pre-tension are relieved again. o The actuator returns to the ex-works condition and can be refitted with LFL functionality. First screw the bayonet nut to the valve and tighten with 2 N. Then fit the actuator to the valve, using no force. o Three grooves on the actuator ring indicate the correct position opposite the three ribs on the bayonet nut. Turn the bayonet ring clockwise until a click is heard. The valve plug is pre-tensioned. o When a second click is heard, the actuator is operable. o This position is the safety position to prevent slackening caused by vibrations. Whilst the bayonet nut is being rotated, the actuator adapts itself to the closing dimension of the valve. Closing dimension compensation The closing dimension compensation is mechanical. Whilst the bayonet nut is being rotated, the compensation pin in the actuator is released. On the NC version, a force is exerted on the valve stem (locked condition) with a minimum force of 90 N by the built-in spring. o The closing dimension is therefore set between this compensation pin and the compensation sleeve and fixed by toothing. o The toothing is designed such that the compensation pin automatically engages in the next row of teeth further down. This ensures that there is always pre-tension acting on the valve cone, making the valve close reliably. Valves may leak due to ageing or because the cone seal has become defective. o Simply slacken the bayonet ring and turn it clockwise again until two clicks are heard. o The actuator has taken on the new closing dimension and the valve is sealed again. Closing dimension compensation (normally closed) If the standard bayonet nut that is provided is used, the actuator can compensate for a closing dimension of 8.5 mm to 13.5 mm. Position indicator Elimination The cover acts as the largest-possible position indicator. It is visible in all directions and is noticeable in dark installation locations. On the 'normally closed' version, the cover rises and the grey stroke part becomes visible. At full stroke, the cover stands up to 5 mm above the upper edge of the plug. On disposal, observe the local legal framework currently in force. 00688_2015-10_ENG 5

Wiring diagram BU = Blue BN = Brown Engineering and fitting notes The starting current of the heating element must be taken into account when choosing the switching contacts and the mains fuses. In order to adhere to the technical specifications, the voltage loss due to the electric wires should not exceed 10%. The light-blue wire should not be switched and must be connected locally with the neutral wire. The controller must always switch the brown wire. Dimensions h (max) = 66 mm h (min) = 59 mm Manufacturer reserves the right to change any product specifications without notice. Reprint, in whole or in part, only with permission of COMAP SA. 00688_2015-10_ENG 6