UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Similar documents
OVERHEAD SERVICE. Items to consider

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

UNDERGROUND SERVICES - SECONDARY

Approved Contractor Construction e-guide Residential Commercial

For Conduit Inspections

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

7. Residential Single-Family and Duplex Buildings (Dwellings)

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

320A Single Phase URD Meter Loop Installations

Installing or Rebuilding Your Electric Service

COMMERCIAL QUICK REFERENCE

10 Commercial, Industrial, Agricultural Services

ELECTRIC SERVICE MANUAL

7 Single Family Service

NEW SERVICE HANDBOOK COMMERCIAL & IRRIGATION SUPPLEMENT

Electric Service Conversion Overhead-to-Underground Xcel Energy Electric Connections. Minnesota North Dakota South Dakota

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

New Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI

CHAPTER 1 INTRODUCTION

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Engineering Rules and Regulations for Electric Service Platte-Clay Electric Cooperative, Inc.

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

SECTION 300 OVERHEAD SERVICE

SINGLE PHASE WIRING SPECIFICATIONS

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

THREE PHASE WIRING SPECIFICATIONS

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Commercial Electric Service Handbook

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

Section 6 Electric Metering: Residential

Transmission & Distribution Glossary of Electrical Terms

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Electric Service Requirements & Guidelines

Electric Service Requirements

TEMPORARY ELECTRICAL SERVICE

Associated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches.

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Marshfield Utilities Rules for Electric Service Installations. Table of Contents

CHAPTER V RESIDENTIAL WIRING

Service Requirements

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Service Requirements

Electric Service Requirements

Electric & Gas Service Requirements (Greenbook) Overview

ELECTRICAL METERING RESIDENTIAL

CHAPTER 2 TYPES OF SERVICE AND VOLTAGES AVAILABLE 8 Types of Service and Nominal Voltage Furnished

U-18. Company furnishes and installs: 10. Service lateral and connectors. 11. Conduit package, Amperes.

Table of Contents. Electrical Service Requirements. 1. General Requirements

Switchgear Skid, C1192

SmartPole Meter for Service to Pole-Mounted Communication Equipment

WPS SERVICE MANUAL. Section 7 Clearances. 7-1 Basic Electric Clearances - Services Miscellaneous Clearances Antenna Clearances...

SECTION VII METERING INSTALLATIONS

Metering and Service Installation:

Indianapolis Power & Light Company

Customer Requirements Meter Socket Configurations

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

KIUC Service Installation Manual

Customer Guide to Electric Service Requirements

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017

INSTALL SERVICE- ENTRANCE SYSTEMS

Published 2018 RULES AND REGULATIONS FOR ELECTRIC SERVICE

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

See NT POWERCOS , Classification Based On Service Size.

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

NEC 2011 Code Changes

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Electric Service Rules

OREGON TRAIL ELECTRIC CO-OP ELECTRIC SERVICE REQUIREMENTS & GUIDELINES

Meter Installation. -and- Padmount Transformer Guide

Electric Service Standards

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

2016 METER SERVICES SPECIFICATION GUIDE

NEW SERVICE HANDBOOK

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

Generator Fire Safety: Generator assemblies should be located outside the building.

10. METERING General Requirements

Pretest Module 24 Three-phase Service Entrance

ROADWAY LIGHTING SYSTEMS (2545)

Spring Test 10 due 05/11/2013

Section 02: Pre-Installation Procedures

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

5. Underground Requirements

WPS SERVICE MANUAL. Section Amp and Smaller - Common

Customer Guide to Electric Service Requirements

Specifications and Requirements for Electric Installations

Commercial & Industrial

THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 15 DPL Building Courthouse Plaza Southwest Dayton, Ohio P.U.C.O. NO. 1

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Transcription:

UNDERGROUND SERVCE tems to consider f your trenching route has to be dug by hand, or if a cable must be installed under a paved surface, additional charges apply. f your service cable has to be moved later to make room for a new swimming pool, patio, deck, etc., new charges apply. Plan ahead! Underground cable will be buried only in a ComEd easement or in the property that it serves. Additional charges apply if your secondary service cable route is longer than 100feet. To avoid additional ComEd charges - a customer can perform the following: can dig their own trench, can install their own cable per municipality requirements - note the customer will then own and maintain the cable, can complete their own boring work per municipality requirements, and can dig their own splice pits. There will be charges from ComEd if you convert from overhead to underground service. You are responsible for making or exposing under - ground sprinkler systems, private wiring, sewers, drain tiles, etc. The trench route must be within 4 inches of final grade and clear of all obstacles (sheds, swing sets, tree stumps, landscaping, fencing, etc.). Generally, restoration of landscaping is the customer s responsibility. Conduit may be required under roads/pavement or by the municipality. 29

Underground Service ~ D-----_ C1 / / D i\,l ~,_, D,/!i :..c JL.J Pedestal :, Tranlformer ~wke\~ l \ Meter \ / f--------- 30

Glossary of Terms Underground Equipment 1 Meter a device that measures the amount of electricity used by a customer. 2 Upper protective cover of the meter fitting 3 Grounding connection. 4 Grounding electrode (ground rod). 5 Disconnecting means the main breaker, fuse box or breaker panel inside your home. 6 Water pipe grounding connection a safety connection to provide an electrical path to ground. 7 Conduit PVC pipe in which the service cable is installed. Must be a mimimum of 3 in. schedule 40 or per local code. Notes: See pages 26-28 for important clearances which must be observed. Check local codes for requirements, such as conduit requirements. For grounding reference, see page 47. 31

Underground Meter Fitting and Raceway D 32

Underground Meter Fitting and Raceway Single-Phase, Three-Wire 120/240 or 120/208 Volts, 200 Amps Maximum Rating 2 3 4 cables** Customer furnishes, installs and maintains: 1 Single position combination meter fitting and raceway (200 amps maximum per meter position) Meter socket load wire terminals Neutral terminal Fifth terminal with potential tap ( # 12 copper wire or equivalent) from neutral terminal (120/208 volt service only) 5 Ground connection per local code 6 Compression lug connectors for phase and neutral 7 Horn type bypass ComEd usually furnishes, installs and maintains: 8 Underground secondary service cables (slack in cables of at least 12 in. must be provided) ComEd furnishes, installs and maintains: 9 Meter Notes: *See pages 39 and 43 for some exceptions. Raceway also available with factory installed main circuit breaker. Meter fittings must be CECHA approved. **Customer to install lugs only when secondary service cables are provided by the customer. For overhead to underground installations, ComEd will supply cable protection on pole at customer s expense. 33

Class 320 Meter Fitting and Raceway o--- - (Covers Removed) (Covers & Meter nstalled) ~O 0 Final Grade -- o /,_ 34

Class 320 Meter Fitting and Raceway Single-Phase, Three-Wire 120/240 400 Amps maximum rating Customer furnishes, installs and maintains: 1 Combination meter fitting and raceway with lever-actuated bypass 2 Compression lug connectors for load conductors 3 Neutral terminal 4 Ground connection, per local code ComEd usually furnishes, installs and maintains: 5 Underground secondary service cables with compression lug connectors. Slack in cables of at least 12 in. must be provided ComEd furnishes, installs and maintains: 6 Meter Note: *See pages 39 and 43 for some exceptions. Raceway also available with factory installed main circuit breaker. Meter fittings must be CECHA approved. For overhead to underground installations, ComEd will supply cable protection on pole at customer s expense. 35

Meter Connection for Mobile Home u--- 0 ---- - > D- Final Grade 34"Min. ' Free-standing, remote from mobile home Concrete Anchor ~ -~.. _. _.-., :... _. 9" Min ~-- -~-:. Sabi;:~]~ N,. ~ 12"Min. m. l "M" /'. S"Min. " "' 4-1/4" Min. 36

Meter Connection for Mobile Homes Single-Phase, Three-Wire 120/240 or 120/208 Volts, 200 Amperes Maximum Rating Customer furnishes, installs and maintains: 1 Combination meter fitting, raceway and pedestal (200 amperes maximum) 2 Meter connection device 3 Enclosure for disconnecting device and receptacles 4 Block for terminating secondary service cables 5 Conductors or bus extending from terminating block to meter socket line terminals 6 Stabilizer foot (#10 gauge metal) or 9 in. x 12 in. x 15 in. concrete anchor 7 Ground connection, per local code ComEd usually furnishes, installs and maintains: 8 Underground secondary service cables with compression lug connectors. Slack in cables of at least 12 in. must be provided ComEd furnishes, installs and maintains: 9 Meter For overhead to underground installation, ComEd will sup- ply cable protection on pole at customer s expense. Note: Raceway also available with factory installed main circuit breaker. Meter fittings must be CECHA approved. 37

Underground Service Customer s Cable Pole 16" Js"Max. 6" 6" S'Max. Service Connection 38

Underground Service Customer s Cable Pole Customer s Cable Pole With Underground Secondary Service Connection Customer furnishes, installs and maintains: 1 Treated pole (Minimum requirements: Class #7, length 25 ft.). Customer shall consult ComEd for minimum setting depth for the class and length of pole installed. 2 Galvanized rigid metal conduit 3 Conduit bushing (if buried portion of cable is not in duct) 4 Galvanized conduit straps and/or lag screws as required nstallation of Customer s Cable Pole and Underground Secondary Service Connection 12 Fork bolt Customer furnishes, installs and maintains: 5 Ground rod, conductor and clamps for grounding metallic conduit on pole 6 Outdoor adapter coupling for metallic to non-metallic conduit (Conduit bushing to be installed if U guard is used above first 10 ft. section) 7 Non-metallic rigid conduit or U guard 8 Cable support 9 Cable in conduit. Cable to extend beyond conduit with enough extra to make connections on pole 10 Sealing compound 11 CECHA Meter fitting 16 Meter ComEd furnishes, installs and maintains: 13 Service drop dead-end 14 Connectors for connecting customer cable 15 Service drop cable 39