Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Similar documents
Aluminum Vertical Break Switch kv A.

Copper Vertical Break Switch kv A.

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Copper Double Break Switch

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

TYPE V CENTER BREAK SWITCH

Product Specifications for Aluminum Vertical Break Switches

TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

AIRBREAK SWITCHES East Ginter Rd. Tucson, Arizona USA (520) Fax (520)

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

Transmission Switching

M-Force three-phase switch

Catalog 14A January 2013

SPECIFICATION BULLETIN

3.0OVERHEAD TRANSMISSION SWITCHES

M-Force three-phase switch

Product Specifications for Phase Over Phase GOABS(r)

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Disconnect & ByPass Switches

Unitized Quick Install Switches for Transmission Applications

Transmission Switching

IB-FAS3 Mar Type FAS THRU 115Kv Amp 61 KA Momentary. Vertical-Break, Gang-Operated Outdoor Air Disconnect Switch.

OVERHEAD DISTRIBUTION SWITCHES

Unitized Quick Install Switches for Substation Applications

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

S&C Recloser Bypass Disconnects

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

Typical Specification

S&C Alduti-Rupter Switches. Outdoor Distribution, 14.4 kv through 69 kv

TYPE BLT DISCONNECT SWITCHES

S&C Manual PME Pad-Mounted Gear

Instructions for Installation and Operation

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Design Standard. Purpose: Design Standard:

Power Fuses. > Power Fuses > BPA & HPA kv AMPs

PATENT PENDING. Phone: (877) Operation and Service Manual

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

S&C Loadbuster Disconnects

Publication No.: PSG

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

OVERHEAD DISTRIBUTION SWITCHES

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Instructions for Installation and Operation

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

OTEC Transfer switch open transition

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Figure 1. HX cutout fuseholders.

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

INSTRUCTIONS Ç CAUTION. S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3. For Field Assembly and Installation NOTE INSTRUCTION SHEET

Solid Dielectric, Single Phase Recloser

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Figure 1. HX cutout fuseholders. Positive Interruption

RAPIER DSB Disconnectors

25 kv Apparatus Bushings

Medium Voltage Metal-Enclosed Switches

Switchgear. Low Voltage

Installation, Operation and Maintenance Manual

Transfer switch OTEC open or delayed transition

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

17.1. Low Voltage Switchgear. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Medium Voltage Metal-Enclosed Switches

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

POWERCON CORPORATION

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

S&C Series 2000 Circuit-Switchers Outdoor Transmission 69 kv through 230 kv

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Underground Distribution Switchgear

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

Low Voltage Switchgear

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

15 kv and 25 kv Thru-Bushings

GE Consumer & Industrial Electrical Distribution. Spectra Series Busway. Busway vs. Wire & Conduit. imagination at work

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Transcription:

Vertical Break Switch Operators/Accessories Ordering Information Furnish: Switch type Voltage Amperage Momentary rating BIL level Mounting position Operator type Accessories required Base mounting holes Base mounting details Available Accessories Swing Handle Operator BASE CONFIGURATION Geared Handcrank Operator Standard Operator Features Swing handle or handcrank operator Padlock provision in both the open and closed positions Ground strap for vertical Adjustable stops Arc horns Auxiliary switch Braidless ground contact Electrical interlock Extended operator Ground blades Ground blade mechanical interlock Insulated vertical pipe Interrupting device Key interlock Mounting hardware Operator grounding platform Outriggers Quick break whips Spill gaps Terminal connectors Clamp-on open/closed indicators Self-lubricating, maintenance-free outboard bearing 2 IPS galvanized steel vertical Adjustable radius outboard bearing lever Motor Operator Type TP-C2 Threaded interphase and drive lever adjustment This brochure describes our standard product and does not show variations in design that may be available. Contact the factory for additional details. Cleaveland/Price reserves the right to make changes or improvements to the product shown in this brochure without notice or obligation. Bulletin DB-A06BH09 Vertical Break Switch 115-230 kv 600-3000 A.

Designed for Simplicity V2-CA APPLICATION The Cleaveland/Price V2-CA is a three pole, group operated, aluminum vertical break switch for installation in substation or transmission line locations. The switch can be mounted in the horizontal-upright, vertical, or horizontal-underhung position. The V2-CA is suitable for use in a variety of applications including line disconnecting and sectionalizing, circuit breaker by-pass and isolation, and transformer isolation. Arc horns or quick break whips can be supplied when small amounts of transformer magnetizing currents or line charging currents must be interrupted. Accessories and options needed to adapt the switch to a customer s particular requirements are available. The V2-CA may be manually operated by use of a swing handle or wormgear mechanism or electrically operated by use of a type TP-C2 motor operator. The V2-CA meets NEMA and IEEE Standards and the rating requirements of applicable IEC Standards. 3 5 4 5 6 7 8 1 2 9 10 1 Unbreakable, non-cast aluminum terminal pads 6 with NEMA standard hole pattern 2 Fully insulated journal bearing 7 3 Unbreakable, non-cast operating crank 8 Counterbalance springs are insulated from the 4 current path as are the counterbalance ice shields. The springs are made of stainless steel for lifelong 9 corrosion resistance. 10 5 Silver-to-silver contacts at hinge and jaw Blade constructed of T-6063 aluminum or tin-plated copper Stainless steel contact springs insulated from the current path Tin-plated, hard-drawn, high conductivity copper contact fingers at hinge and jaw Hot-dip galvanized double channel base Insulator leveling screws

Engineered for Performance THE CLEAVELAND/PRICE APPROACH Cleaveland/Price has a very basic approach to design... keep it simple. It is an approach that is employed from material selection to mechanical design. All Cleaveland/Price disconnect switch current carrying parts are manufactured from high strength, high conductivity aluminum or copper. All switches are of non-cast design for superior dependability of parts. Switch performance is not troubled by flaws that could occur in the casting process. Contacts on the V2-CA are designed to take advantage of electromagnetic forces by using a reverse loop configuration at both the hinge and jaw of the switch. Current transfer points are kept to a minimum. PROBLEM: When the switch blade on a conventional switch rotates in the break-jaw to the final blade position, it does not consistently stop at the point of optimum contact pressure. The resulting inadequate contact pressure may cause contact pitting and burning. Many switches use a stop on the rotating insulator to try to set proper blade position. This type of stop is too remote from the blade to accurately control the blade motion because of the cumulative play in the linkage joints. Variation in the speed of the operator can actually affect the amount of blade turnover. CUTAWAY VIEW STOP HINGE PIN ROTATION IN BREAK-JAW IS CONTROLLED BY THE STOP SOLUTION: On the Cleaveland/Price V2-CA, the blade stop is on the blade itself instead of an intermediate linkage point (the rotating insulator). The V2-CA stop location assures that blade rotation in the break-jaw will accurately and consistently stop at the point of maximum contact pressure. The cutaway view shows how the unique Cleaveland/Price turnover stop allows the blade to rotate until the slot in the blade engages with the hinge pin. This sets the proper turnover angle. The stop angle is factory-machined for built-in accuracy. No matter how fast or slow the blade moves, it doesn t stop moving until it has fully turned over. CLEAVELAND/PRICE FEATURES FOR OUTSTANDING PERFORMANCE AND LONG LIFE The V2-CA is made of the finest materials for dependable, trouble-free service. Knowledge gained from maintaining switches in the field for over 60 years has played a major part in refining the V2-CA. Significant design features include: Total non-cast copper, aluminum, and steel construction resulting in the superior dependability of parts. Live parts constructed from hard-drawn, high conductivity copper and extruded aluminum, producing stronger, more conductive components than parts made of cast materials. Open hinge contacts allow easy verification of contact condition without disassembly or infrared testing. Open construction of the hinge and smooth non-cast surfaces throughout, enabling the V2-CA to break ice with amazing ease. Wiping action on both the break-jaw and hinge keeps contacts clean for years of reliable service. Reverse loop electromagnetic design at hinge and break-jaw on all ratings gives outstanding performance under fault conditions. Bolted connections are aluminum to tin-plated copper. All bolted contact surfaces are prepared and treated with an oxide inhibitor. Moving contacts are silver-to-silver with a hard-drawn, high-conductivity copper base material.

Exclusive Cleaveland/Price V2-CA Features The Cleaveland/Price V2-CA is an advanced design vertical break switch with features of genuine value to the customer. It incorporates several patented improvements: 1. Positive blade turnover stop is the key to consistent and complete contact pressure to prevent contact burning. 2. Insulating journal bearing prevents current flow through the live operating linkage. 3. Floating break-jaw contacts allow blade and break-jaw fingers to move together under short circuit and seismic duty to outperform conventional contact systems. FEATURE FOR EASY ADJUSTMENT UNIQUE BREAK-JAW DESIGN Short circuit tests prove that the V2-CA break-jaw is superior to conventional break-jaws. On the V2-CA, phaseto-phase electromagnetic forces that pull the blade side-toside do not decrease the contact pressure since the fingers of the jaw are joined together to create a floating spring system that moves with the blade. Maximum contact pressure is maintained on all contact surfaces during short circuit and seismic events. ADVANCED V2-CA BREAK-JAW maintains consistent contact pressure as blade and jaw fingers move to the side together as a unit under short circuit forces. CONVENTIONAL BREAK-JAW loses contact pressure as the blade moves to the side because of electromagnetic forces. ANSI standards require that a switch pass the rated short circuit test only once. Standards also allow live parts to be changed for each test. The V2-CA gives greater confidence in short circuit performance as demonstrated by 12 consecutive test shots on a 2000 ampere switch using the same set of live parts. Superior Bearing Assembly High strength, non-cast, hot-dip galvanized steel shaft Special ozone and ultraviolet resistant seals outlast conventional seals and contain no metal parts which typically corrode Maintenance-free, permanently lubricated construction Individually sealed ball bearing assemblies in sealed, grease-packed housing Permanently adjusted bearing PIVOTING HINGE During installation, the blade may be misaligned with the break-jaw, requiring adjustment of the jacking bolts at the base of the insulators. However, it is often easier to pivot the blade to attain alignment with the jaw contact. This is particularly true when bus and ground blades have been installed at the jaw terminal and the blades are not perfectly adjusted. By loosening the bolts that attach the hinge and jaw to the stationary insulators and closing the switch, the blade and jaw automatically seat themselves in the proper alignment. Retighten the bolts and the adjustment is complete without having to realign the ground switch or bus.

Vertical Break Switch Operators/Accessories Ordering Information Furnish: Switch type Voltage Amperage Momentary rating BIL level Mounting position Operator type Accessories required Base mounting holes Base mounting details Available Accessories Swing Handle Operator BASE CONFIGURATION Geared Handcrank Operator Standard Operator Features Swing handle or handcrank operator Padlock provision in both the open and closed positions Ground strap for vertical Adjustable stops Arc horns Auxiliary switch Braidless ground contact Electrical interlock Extended operator Ground blades Ground blade mechanical interlock Insulated vertical pipe Interrupting device Key interlock Mounting hardware Operator grounding platform Outriggers Quick break whips Spill gaps Terminal connectors Clamp-on open/closed indicators Self-lubricating, maintenance-free outboard bearing 2 IPS galvanized steel vertical Adjustable radius outboard bearing lever Motor Operator Type TP-C2 Threaded interphase and drive lever adjustment This brochure describes our standard product and does not show variations in design that may be available. Contact the factory for additional details. Cleaveland/Price reserves the right to make changes or improvements to the product shown in this brochure without notice or obligation. Bulletin DB-A06BH09 Vertical Break Switch 115-230 kv 600-3000 A.

Vertical Break Switch Operators/Accessories Ordering Information Furnish: Switch type Voltage Amperage Momentary rating BIL level Mounting position Operator type Accessories required Base mounting holes Base mounting details Available Accessories Swing Handle Operator BASE CONFIGURATION Geared Handcrank Operator Standard Operator Features Swing handle or handcrank operator Padlock provision in both the open and closed positions Ground strap for vertical Adjustable stops Arc horns Auxiliary switch Braidless ground contact Electrical interlock Extended operator Ground blades Ground blade mechanical interlock Insulated vertical pipe Interrupting device Key interlock Mounting hardware Operator grounding platform Outriggers Quick break whips Spill gaps Terminal connectors Clamp-on open/closed indicators Self-lubricating, maintenance-free outboard bearing 2 IPS galvanized steel vertical Adjustable radius outboard bearing lever Motor Operator Type TP-C2 Threaded interphase and drive lever adjustment This brochure describes our standard product and does not show variations in design that may be available. Contact the factory for additional details. Cleaveland/Price reserves the right to make changes or improvements to the product shown in this brochure without notice or obligation. Bulletin DB-A06BH09 Vertical Break Switch 115-230 kv 600-3000 A.