F-2700 SERIES INSERTION VORTEX FLOW METER

Similar documents
F-2700 SERIES INSERTION VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-2600 SERIES INLINE VORTEX FLOW METER

F-2500 SERIES VORTEX METER

Armstrong In-Line and Insertion Vortex Flow Meters

VIM20 Vortex Insertion Flowmeter

Multivariable Vortex Flow Meter

Vortex Flowmeter Model DVE

Multivariable Vortex Flow Meter

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

VIM20 Vortex Insertion Flowmeter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

The readings you need, right where you need them. AX Series Vortex Meters

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VIM20 Vortex Insertion Flowmeter

VLM20 In-line Vortex Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

Vortex Flow Meter Model DVH

RIM20 Rotor Insertion Flowmeter

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

VORTEX IN-LINE FLOW METERS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Vortex In Line Flow Meter

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Low Profile Insertion Vortex

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Hot Tap Insertion Vortex

Transmitting Transducer. Gas/Air Velocity Range:

Vortex In Line Flow Meter

ISTEC MAGNETIC METERS

Model FVP General Specification. Flanged Vortex Plate. Product Features

Vortex Eggs Delta Flowmeter

Vortex Plate. Model VP General Specification. Product Features

VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual

Instruction Manual Vortex Flow Meter DVH / DVE

TURBINE FLOW METER SELECTION GUIDE

240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

DVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

GE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

220 Series Innova-Flo o

DW PADDLE-BELLOWS FLOWMETER & SWITCH

SIGNET 7002 Vortex Flow Sensor ENGLISH

Hydro-Flow Model 2200 Installation and Operation Guide B

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

DW PADDLE-BELLOWS FLOWMETER & SWITCH

RCM - Direct Reading Flowmeters

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

DW PADDLE-BELLOWS FLOWMETER & SWITCH

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

mass flowmeter for compressed air

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Model 1000 Vortex Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

F-5100 Insertion Thermal Mass Flow Meter Installation and Operation Guide

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Model 5000 Vortex Meter

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

NC State University Design and Construction Guidelines Division 23 Energy Management

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Hydro-Flow Model 3100

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

UTM10 Series Ultrasonic Transit-time Flowmeters

imag 4700 SERIES FLANGED MAGMETER

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

VersaFlow Vortex 100 Vortex Flow Meter Specifications

STEEMCO Flowmeter for Steam

Rosemount 8800D Series Vortex Flowmeter

Appendix. Clearance. Skewed profiles. Application Schematics

flow measurement solutions RIM10 series rotor insertion flowmeters

Ultra Mag SUBMITTAL PACKAGE

Range of Ultrasonic Flowmeters.

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

mass flowmeter for compressed air

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Full Profile Insertion

M3500 Industrial Pressure Transmitter

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

SITRANS F X SITRANS FX300 3/355

Transcription:

F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C) standard 750 F (400 C) optional Compressed air Industrial gases CALIBRATION MADE IN THE USA Vortex flow meters detect the frequency of alternating low pressure vortices that are formed as flow is diverted around a bluff body. These swirling low pressure zones apply lateral pressure first to one side and then to the other of sensors located downstream of the bluff body. This causes the sensors to vibrate. The frequency of this vibration is directly proportional to the flow velocity. DESCRIPTION The ONICON F-2700 Series Insertion Vortex Flow Meter is a flexible design that delivers accurate, reliable flow measurement in a wide variety of applications. The integral temperature sensor and optional integral pressure sensor allow for direct mass flow measurement in steam and compensated flow measurement in compressed air and gases. A volumetric flow version of the meter is also available for liquid flow applications. ONICON insertion style vortex meters can be installed without disrupting flow making them ideal for retrofit applications. They are also a cost effective option in larger pipes as they are priced independent of the pipe diameter. A version of the F-2700 with temperature and optional pressure compensation is available as a DC loop powered (2-wire) device with analog and pulse outputs. Optional external DC and AC powered versions of the meter are also available. These versions offer additional options for serial communications and additional analog, pulse, frequency and alarm outputs. Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration accompanies every meter. FEATURES Mass flow measurement from a single instrument Optional steam energy flow measurement Integral 1,000 W platinum RTD for precise temperature measurement Optional integral pressure transducer for accurate pressure readings at the meter location DC loop powered operation Maintenance free non-moving parts design Wear resistant bluff body/sensor design Advanced signal processing algorithms ensure stable flow readings and reject noise. Easy-to-install meter arrives fully programmed and ready to use. Optional multi-analog output versions available. HART serial communication Optional BACnet MS/TP or MODBUS RTU RS485 serial communication GENERAL SPECIFICATIONS ACCURACY Steam and gases (Reynolds Number 10,000) Percent of reading accuracy to within: ± 1.0% for steam and gases (volumetric) ± 1.5% for steam and gases (mass) Repeatability: ± 0.2% Long term stability: ±0.2% over a period of 1 year Liquids ± 0.7% for liquids (volumetric) Repeatability: ± 0.2% Long term stability: ±0.2% over a period of 1 year 0795-7 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 www.onicon.com sales@onicon.com 02-15

EXIT SENSING METHOD Vortex shedding with integral piezoelectric sensors Integral 1,000 W platinum RTD (optional) provides instantaneous temperature Integral pressure transducer (optional) provides instantaneous pressure. OPERATING TEMPERATURE RANGE Ambient: -40 F (-40 C) to +185 F (+85 C) Process: -330 F (-200 C) to +500 F (+260 C) Optional high temperature limit +750 F (+400 C) MAXIMUM OPERATING PRESSURE Flange rating or 1500 psi (103 bar) PRESSURE LOSS loss varies with meter size and flow rate. Please contact ONICON for detailed information. CONNECTION TYPE NPT threads with Packing Gland 2" ANSI Class 150 Flange with Packing Gland 2" ANSI Class 300 Flange with Packing Gland MATERIALS Wetted Metal Parts Electronics Enclosure: 316L Stainless Steel Epoxy painted aluminum INPUT POWER OPTIONS Loop Power: 14-36 VDC, 22 ma maximum current External DC Power: 18-36 VDC, 300 ma maximum current Eternal AC power: 100-240 VAC 50/60 Hz, 5W. maximum power ENCLOSURE NEMA 4X (IP66) DISPLAY 2-line, 16 character alphanumeric LCD with backlighting option. Standard saturated steam display menu provides: Mass Flow Rate, Temperature, (calculated), Mass Total and Alarms (if active). Optional remote mount transmitter version available (Standard cable length 50 ft., maximum 150 ft.) OUTPUT SIGNALS PROVIDED DC loop powered version Analog Rate: 2-wire, 4-20 ma, 14-36 VDC, maximum loop resistance = RL ((V supply - 12 V) /.020 A) Totalization: 2-wire open collector scaled pulse, 50 ms duration, 5-36 VDC and 40 ma / 320 mw maximum Frequency: 2-wire open drain FET, 10 khz maximum frequency, 5-36 VDC and 40 ma / 200 mw maximum Digital: HART serial communications Optional Backlight Connection: Requires external 12-36 VDC power supply, 35 ma maximum current Optional DC or AC powered version Analog Rate: Up to (3) 2-wire, 4-20 ma, 14-36 VDC, maximum loop resistance = RL ((V supply - 12 V) /.020 A) Totalization: (1) 2-wire open collector scaled pulse, 50ms duration, 5-36 VDC and 40 ma / 320 mw maximum Frequency: (1) 2-wire open drain FET, 10 khz maximum frequency, 5-36 VDC and 40 ma / 200 mw maximum Alarm: Up to (3) opto-coupled relay alarm outputs Digital: HART serial communications Optional on DC or AC powered version BACnet MS/TP or MODBUS RTU RS485 serial communications in place of HART Specifications subject to change without notice. REMOTE MOUNT INSTALLATION 2.1 in 3.0 in 5.0 in 8.3 in 5.7 in 3.0 in REMOTE CABLE, 50 FT STANDARD LENGTH 5.0 in 0.6 in 2.8 in REMOTE ELECTRONICS OPTION AVAILABLE ON ALL MODELS.34 in DIA. U Bolt Provided F-2700 Series Insertion Vortex Flow Meter Catalog Sheet 02-15 - 0795-7 Page 2

EXIT STRAIGHT RUN REQUIREMENTS Insertion Vortex Flow Meter (for pipes 2 in diameter) PIPE RUN ECCENTRIC REDUCER UPSTREAM OPTIONAL FLOW STRAIGHTENER ECCENTRIC EXPANSION DOWNSTREAM PIPE RUN FLOW DIRECTION 2 DIAMETERS UPSTREAM STRAIGHT PIPE RUN TO FLOW STRAIGHTENER * MINIMUM UPSTREAM STRAIGHT PIPE RUN TO FIRST OBSTRUCTION MINIMUM DOWNSTREAM STRAIGHT PIPE RUN 5 DIAMETERS Obstruction Single bend preceded by 9 diameters of straight pipe * Upstream Straight Pipe Run Requirements Straight pipe run without flow straightener Straight pipe run to flow straightener 10 Dia NA Outflowing tee 10 Dia NA Pipe size reduction before meter 10 Dia NA Single bend preceded by 9 diameters of straight pipe 15 Dia 8 Dia Expansion before meter 20 Dia 8 Dia Multiple bends out of plane 30 Dia 13 Dia Partially open valve 30 Dia 13 Dia Control valve / P.R.V. 50 Dia 23 Dia F-2700 Series Insertion Vortex Flow Meter Catalog Sheet 02-15 - 0795-7 Page 3

FLOW METER OPERATING RANGES Insertion Meter Flow Rates for Saturated Steam Nominal diameter in inches and Saturated Steam Flow Rates @ Specific Operating s Insertion Meter Flow Rates in lb/hr Nominal Diameter (in), Schedule 40 5 15 50 75 100 150 200 300 (psig) Density (lb/ft 3 ) 0.0479 0.071 0.1497 0.2042 0.2578 0.3633 0.4680 0.6784 lbs / hr 3 205 2721 248 3995 357 8295 417 11288 468 14246 557 20111 632 25948 762 37652 4" 353 4685 427 6880 616 14284 718 19438 807 24532 958 34631 1089 44683 1311 64838 6" 800 10633 969 15614 1397 32417 1629 44112 1831 55674 2175 78592 2470 101405 2976 147145 8" 1385 18412 1679 27038 2419 56135 2822 76385 3170 96407 3766 136092 4278 175595 5153 254799 10 2184 29022 2646 42618 3813 88481 4447 120401 4996 151960 5936 214513 6743 276779 8123 401623 12" 3099 41196 3756 60495 5412 125597 6313 170907 7092 215703 8426 304495 9572 392880 11530 570093 14" 3746 49788 4539 73112 6541 151792 7630 206551 8571 260691 10184 368001 11568 474820 13935 688994 16 4893 65039 5930 95508 9967 269822 1470 39801 11197 340546 13303 480728 15111 620268 18203 900047 Flow Rates for Water Rate Water and Flow Rates (GPM) Nominal Diameter (in) 3 4 6 8 10 12 14 16 24 Min GPM 20.6 35.9 81.3 142 224 317 383 502 1140 Max GPM 618 1076 2440 4274 6724 9514 11486 15062 34184 F-2700 Series Insertion Vortex Flow Meter Catalog Sheet 02-15 - 0795-7 Page 4

METER ORDERING INFORMATION Insertion Vortex Meter Codification = F-2700-ABC-DEFG A = Connection Type 0 = 2 Male NPT threads with retractor 1 = 2 ANSI class 150 flange with retractor 3 = 2 ANSI class 300 flange with retractor 6 = 2 ANSI class 600 flange with retractor 7 = 2 Male NPT threads without retractor ( 50psig maximum pressure) 8 = 2 ANSI class 150 flange without retractor ( 50psig maximum pressure) 9 = 2 ANSI class 300 flange without retractor ( 50psig maximum pressure) B = Integral or Remote Mount Transmitter 1 = Integral Mount 2 = Remote Mount C = Temperature / Compensation 0 = Integral temperature compensation 1 = Integral temperature & pressure sensor, 30 psia maximum 2 = Integral temperature & pressure sensor, 100 psia maximum 3 = Integral temperature & pressure sensor, 300 psia maximum 4 = Integral temperature & pressure sensor, 500 psia maximum 9 = None D = Input Power 0 = Loop powered (Only available with Output Signals option F=0) 1 = External 12-36 VDC powered 2 = External 85-240 VAC powered E = Output Signals 0 = 4-20mA output*, pulse output & frequency output 1 = 4-20mA output, pulse output & frequency output, alarm output & MODBUS 2 = 4-20mA output, pulse output & frequency output, alarm output & BACnet 3 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & MODBUS 4 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & BACnet 5 = (3) 4-20mA outputs*, (3) alarm outputs, (1) pulse output (1) frequency output 6 = 4-20mA output*, pulse output & frequency output, alarm output F = Operating Temperature 0 = 500 F 1 = 750 F G = Energy Meter 0 = None 1 = Gross energy meter 2 = Net energy meter (requires additional remote temperature sensor.) * Available with HART serial communications Remote Temperature Sensor and Thermowell Installation Kit (Required for Net Energy Meter) Part Number Description 20100 Remote Temperature Sensor, 1,000 Ohm 4-wire Class A Platinum RTD 20101 Remote Thermowell Kit for 1½" Welded Steel Pipe 20102 Remote Thermowell Kit for 2-5" Welded Steel Pipe 20103 Remote Thermowell Kit for 6-14" Welded Steel Pipe Note: Net energy meter requires 1 temperature sensor and 1 thermowell installation kit sized to pipe. F-2700 Series Insertion Vortex Flow Meter Catalog Sheet 02-15 - 0795-7 Page 5

EXIT EXIT INSERTION METER DIMENSIONS & WEIGHTS Retractor REMOVABLE Required RETRACTOR for Applications REQUIRED Over FOR 50 APPLICATIONS PSIG OVER 50 PSIG 8.0 in (203 8.0 inmm) (203 mm) 5.0 in (127 5.0 inmm) (127 mm) 3.0 in 3.0 (76 inmm) (76 mm) A A transducer transducer housing housing (empty on some (empty models) on some models) * Orientation Orientation lever lever 3/4" NPT 3/4" Conduit NPT Conduit entry entry Electronics Electronics enclosure enclosure clamp clamp Packing Packing gland gland 2 inch 2 inch Male 2 inch NPT B max. 2 male inch NPT Male NPT B max. male NPT Vortex Vortex sensor sensor head head *This dimension is the same for integral and remote mount meters. 2 inch 2 Mounting inch flange Mounting flange Depth marker Depth marker arrow arrow Stanchion Stanchion Scribe mark Scribe mark Insertion tool Insertion tool Upper retractor bracket Upper retractor bracket lock bolt lock (center) bolt Sensor (center) Sensor alignment alignment pointer pointer clamp nuts clamp nuts clamp bolts clamp bolts Packing gland nuts Packing (covered gland by stem nuts clamp) (covered Lower retractor by stem clamp) Lower bracket retractor bracket housing housing Mounting Option Standard Length Extended Length in (mm) A B A B Mounting Option in (mm) Standard Length Male NPT 40.5 (1029) 21.5 (546) 52.5 A(1334) 33.5 B(851) ANSI Packing Class Gland 150 Flange & Male NPT 40.5 (1029) 21.1 (536) 52.5 (1334) 40.5 (1029) 33.1 (841) 21.5 (546) ANSI Class 300 Flange 40.5 (1029) 21.1 (536) Packing Gland & ANSI Class 150 Flange 52.5 (1334) 40.5 (1029) 33.1 (841) 21.1 (536) Packing Gland & ANSI APPROXIMATE Class 300 Flange WEIGHT, LB (KG) 40.5 (1029) 21.1 (536) SL EL APPROXIMATE WEIGHT, LB (KG) NPT 16 (7.1) 17 (7.6) SL EL Class 150 21 (9.4) NPT 22 (9.9) 16 (7.1) 17 (7.6) Class 300 25 (11.3) 26 (11.8) Class 150 21 (9.4) 22 (9.9) Add 11 LB (5 KG) for remote electronics Class 300 25 (11.3) 26 (11.8) Add 11 LB (5 KG) for remote electronics Extended Len A 52.5 (1334) 33. 52.5 (1334) 33. 52.5 (1334) 33. Sensor head Sensor head F-2700 Series Insertion Vortex Flow Meter Catalog Sheet 02-15 - 0795-7 Page 6

FLOW STRAIGHTENER Gasket Thickness, Nominal Serrations show located under gasket, if provided. 0.1250 Note: Dimension C indicates ID for serrations. Dim B Dim C Dim A 1.0625 # of holes - 35 Diameter Dim A Dim B Dim C Part # Each 2 (50mm) 3.93.28 2.14 14382 3 (80mm) 5.31.43 3.24 14383 4 (100mm) 6.26.55 4.22 14384 6 (150mm) 8.50.78 6.07 14385 8 (200mm) 10.62 1.02 7.98 14386 PRE-CUT GASKETS Pre-cut ⅛ gaskets for use with class 300 raised face flanges. Gaskets are suitable for use with water, inert gases and saturated steam up to 150 psig. For saturated steam applications above 150 psig, contact ONICON for assistance. Diameter Part # Each 2 (50mm) 16813 3 (80mm) 16814 4 (100mm) 16815 6 (150mm) 13816 8 (200mm) 16817 PRESSURE TRANSDUCER OPTIONS Full Scale Operating PSIa Overrange PSIa 30 60 100 200 300 600 500 1000 1500 2500 F-2700 Series Insertion Vortex Flow Meter Catalog Sheet 02-15 - 0795-7 Page 7