INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

Similar documents
Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Automation Swing Gate Opener

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

INSTRUCTIONS FOR INSTALLATION

ARACHNE 230V 24V- 12V

SWING GATE OPENERS 24V DC GEAR MOTOR

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Ditec LUXO Swing gates automation (Original instruction)

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

E R A I GATE AUTOMATION DIVISION

Automation Swing Gate Opener

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

FITTING AND CONNECTION INSTRUCTIONS

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

BARRY BARRIER GATE AUTOMATION

Ditec PWR50H/HV/HR Automation for swing gates

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Ditec PWR25H/35H Automation for hinged gates

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Ditec BOX Balanced up and over doors

Typical Installation Schematic

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Couper. Motori gear for swing gates MADE IN ITALY INSTRUCTION MANUAL

Ditec CUBIC Swing gates automation

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

BISON 20 OM BISON 25 OTI

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Installation Manual. Swing Gate System. Leading the way...

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Porte 150 Users Manual Swing Gate Opener 24V DC

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

BULL 424 ESA BULL 624 ESA

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Jet. Gear motor for swing gates MADE IN ITALY INSTRUCTION MANUAL

CE DECLARATION OF MACHINE CONFORMITY

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

FEATURES AND SPECIFICATIONS

CATALOGUE. Professional

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

MOOVY AUTOMATIONS FOR SLIDING GATES (230/110/24V)

MhouseKit GD0 For the automation of a sectional or overhead door.

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

SWING GATE OPENERS 24V DC GEAR MOTOR

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

AUTOMATIC BOLLARD ASSEMBLY AND OPERATING MANUAL

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Wingo4024 Swing gate opener. EN - Instructions and warnings for installation and use

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

FORCE SPD 800/1500/2000

Mod: KLD6-12/35XLAS-N

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

Electromechanical gear motor for sliding gates ACHILLES

Ditec DOD Industrial sectional door automations

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

ALPHA 200 PLUS ALPHA 330 PLUS INSTALLATION MANUAL

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

GB Instructions Manual

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000. English

HYDRAULIC SWING GATE OPENER

Differential Pressure Transmitter

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

ARTICULATED ARM GATE OPENER USER MANUAL

BELT CONVEYOR CB/M5 Series

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

SLIDING GATE OPENER USER MANUAL

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

is250/is250d/is250solar SWING GATE OPENER MANUAL

CP-LIFT. Plazma lift 1. LIST OF ITEMS: 2. INSTALLATION and ADJUSTMENTS: Dimention of the lift: L: 1375 mm W: 965 mm D: 236 mm

Sectional and Tilting Door Opener

INSTALLATION MANUAL (cod )

INDUSTRIAL DOOR OPERATOR 119CT54EN INSTALLATION MANUAL C-BX_C-BXK_CBXE_CBXEK C-BXT_C-BXET_C-BXE24. English

Cross Automations for sliding gates

BELT CONVEYOR PNL/4 Series User and maintenance manual

Transcription:

INSTLLTION MNUL E Gearmotor for swing gates 0_7

Index. SFETY INSTRUTIONS... pag. 0 OMPLINE DELRTION... pag. 0 2. DESRIPTION ND INTENDED USE... pag. 0 2. Technical data... pag. 02 2.2 Kit content... pag. 02 2.3 Dimensions... pag. 02 3. INSTLLTION... pag. 03 3. Preliminary checks... pag. 03 3.2 Wiring... pag. 03 3.2. Standard installation 3.2.2 able types and minimum thicknesses 3.3 Establishing RH and LH operator... pag. 04 3.4 Fastening the gearmotor... pag. 04 3.4. Vertical positioning quota 3.4.2 Horizontal positioning quota 3.4.3 Outward opening... pag. 06 3.5 Fastening rear bracket T... pag. 06 3.6 Fastening front bracket S3... pag. 06 4. RELESING THE GERMOTOR... pag. 07 5. MINTENNE... pag. 07 6. DISMNTLING ND DISPOSL... pag. 07

. SFETY INSTRUTIONS TWarning: Important safety instructions for people, RED REFULLY when you see this symbol: This product must only be used for its intended purpose. ny other use is dangerous. Follow all instructions as improper installation may result in in serious bodily injury. Keep these warnings together with the installation and operation manuals that come with the gearmotor. lways cut off the power supply before performing any type of intervention. lways make sure the gearmotor is properly connected to the earth Use and installation of the product must comply with Machinery Directive 2006/42/E. Verify that the system is EN 24445 and EN 2453 standard compliant. Installation must be carried out by expert qualified personnel who knows the potential hazards associated and in full compliance with current regulations. Use of the product must be restricted to its intended use. ny other use is to be considered dangerous and therefore forbidden. Do not allow children to play with the fixed command devices, or in the gate s area of operation. Keep any remote control devices (i.e. transmitters) away from children, to prevent the gearmotor from being accidentally activat Keep the gate and the gate opener regularly maintained. Use only Proteco s original spares. Users are strictly forbidden to carry out any changes on the gate operator. Proteco ancelli utomatici Srl is not liable for any damage resulting from improper, wrongful or unreasonable use. E OMPLINE DELRTION Manufacturer: ddress: declares that IThe product type: Models: PROTEO S.r.l. Via Neive, 77 2050 astagnito (N) ITLI E electromechanical gear motor for swing gates E 3 TI, E 4 TI, E 4 REV, E 3 24 TI, E 4 24 TI E 4 T, E 4 24 -T Is built to be integrated into a machine or to be assembled with other machinery to crate a machine under provisions of 2006/42/E Machinery Directive, with reference in particular to the following requirements:..2..3..5.2..2.2.2.3.2.6.3.2.3.4.3.9.4..4.2..5..5.4.5.6.5.8.5.3.6..6.4.7..7.3.7.4 ÈIt complies with the essential requirements of EE Directives: 2004/08/E (electromagnetic compatibility) 999/5/E (R&TTE) 20/65/E (directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment) It complies with the essential requirements of EE Directives: EN 2453 Industrial, commercial and garage doors and gates. Safety in use of power operated doors. Requirements EN2445 Industrial, commercial and garage doors and gates. Safety in use of power operated doors. Test methods. EN 60335- Safety of household and similar electrical appliances - Part I: General requirements EN 60335-2-03 Household and similar electrical appliances - Part 2-03: Particular requirements for drives for gates, doors and windows. The manufacturer also declares that the start-up of the machinery is not permitted unless the machine, in which the product is incorporated or of which is becoming a component, has been identified and declared as conformed to 2006/42/E Machinery Directive. astagnito, 3 October 206 Marco Gallo EO 2. PRODUT DESRIPTION ND INTENDED USE E gear motors are designed to automate residential or commercial swing gates with one or two wings. ny other use than above described has to be considered as inappropriate and strictly prohibited. ll models feature an irreversible gearing system that locks the gate when it is in its fully closed position. Therefore no additional lock is needed. In case of a power failure the motor lock can be released to move the gate manually (from inside). The 24V versions can also be powered by a back-up battery system that allows emergency openings even in case of a power cut.

E TI ce 3 TI ce 4 TI ce 4 REV Motor power supply 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz Max draw.,2 -,7,2 -,7,2 -,7 Power 300W 300W 250W apacitor 0µF 0µF 8µF Thermal protection 50 50 50 djustable thrust 3000 N 3000 N 2500 N Protection rating 44 44 44 Revolutions 400 rpm 400 rpm 900 rpm Opening angle 20 deg 20 deg 20 deg Opening time (90 ) 7 22 22 Leaf weight 350 Kg 400 Kg 350 kg Leaf length 2,0 m 3,0 m 3,0 m Duty cycle 40% 40% 40% ce 3 TI 24 ce 4 TI 24 ce 3TI 5 ce 4 TI 5 24V dc 24V dc 5V ~ 60Hz 5V ~ 60Hz 0,5-0,75 0,5-0,75 3, - 3,3 3, - 3,3 50W 50W 300W 300W 20µF 20µF 50 50 2500 N 2500 N 3000 N 3000 N 44 44 44 44 600 rpm 600 rpm 700 rpm 700 rpm 20 deg 20 deg 20 deg 20 deg 5 20 5 8 250 Kg 300 Kg 350 Kg 400 kg 2,0 m 3,0 m 2,0 m 3,0 m 80% 80% 40% 40% E T ce 4 T ce 4 T 24 ce 4 T 5 Motor power supply 230V ~ 50Hz 24V dc 5V ~ 60Hz Max draw.,2 -,7 0,5-0,75 3, - 3,3 Power 300W 50W 300W apacitor 0µF 20µF Thermal protection 50 50 djustable thrust 3000 N 2500 N 3000 N Protection rating 44 44 44 Revolutions 400 rpm 600 rpm 700 rpm Opening angle 0 deg 0 deg 0 deg Opening time (90 ) 22 20 8 Leaf weight 350 Kg 200 Kg 350 Kg Leaf length 2,5 m 2,5 m 2,5 m Duty cycle 40% 80% 40% 2.2 KIT ONTENT 2 3 4 5 E TI E Swing operator 2 SPIP0770 Rear RH bracket T SPIP0870 Rear LH bracket T 3 MGR40Z Fixing pack MPE226 4 SPI0270 Front bracket S3 5 Release key 2 3 4 5 E T E Swing operator 2 SPIP0770 Rear RH bracket T SPIP0870 Rear LH bracket T 3 MGR40Z Fixing pack MPE226 MRO2Z MDM2 4 SPI0370 Front bracket S4 5 Release key 2.3 DIMENSIONS 30 30 ce 3 = 85 mm - ce 4 = 95 mm ce 4 T = 040 mm ce 3 = 35 mm - ce 4 = 335 mm 2

3. INSTLLTION 3. Preliminary checks efore installing make sure: The gate conditions are suitable to automate. Weight, dimensions and gate construction are proper for the operator you intend to buy. You have suitable mechanical ground stops. The automated parts are in good mechanical conditions. The opening of the automated gate is not an entrapment hazard as regards any surrounding fixed parts and there is sufficient space for manual release. ny lawn watering devices will not wet the gearmotor from the bottom up. The earth cable is properly connected. Do not install onto gates on either an upward or downward slope (i.e. that are not on flat, level ground). 3.2 Wiring 3.2. Standard installation Fig. F E D 3.2.2 LE TYPES ND MINIMUM THIKNESSES The quantities of tubes and cables needed (not included in the kit) depend on the type and number of accessories connected to the gate area. 230V operator 3x,5 Earth ontrol panel 2x,5 + Earth Photocell receiver rx 4x0,75 ¹ Photocell transmitter tx 2x0,75 D Key switch 2x0,75 E erial RG58 F linker 2x0,75 24V 2x,5 2x,5 + Earth rx 4x0,75 tx 2x0,75 2x0,75 RG58 2x0,75 3

ut off the power before starting wiring. Make sure you have set up a suitable dual-pole cut off device ( 3 mm wires) along the power supply. Make sure you have suitable tubing and conduits for the electrical cables: connect the motors, control panel and accessories using separated currugated tubes, in order to prevent interferences that may result in bad operation. Fit the power cable keeping a curve as shown in picture 2, in order to avoid water blackflow inside the operator. ll opening commands and safety devices must be free of tension (dry contact). Fig. 2 LEFT HND operator RIGHT HND operator 3.3 ESTLISHING RH ND LH OPERTOR The ram operators are supplied handless version, it means they can be installed either on the right or left side of the gate (see picture 3). Fig. 3 = Mechanical ground stops Fig. 4 E TI Gate in closing position - inox pipe maximum extension: ce 3 = 345 mm ce 4 = 445 mm Gate in opening position - inox pipe minimum extension 50 mm (see picture 4). 50 mm 345 mm E 3 TI 445 mm E 4 TI E T Gate in closing position: minimum distance 50 mm. Gate in opening position: maximum distance 450 mm. (see picture 5) Fig. 5 opening position 445 mm closing position 3.4 FSTENING THE GERMOTOR 3.4. Vertical positioning quota a) If the gate is sturdy you can fit the gearmotor wherever it goes, at any height from ground. b) If the gate is particularly light fit the gearmotor as close as possible to gate centerline. 50 mm 3.4.2 Horizontal positioning quota Gate leaf hinged in the center of the pillar (see picture 6). Gate leaf hinged on the corner of the pillar(see picture 7). est of performance is obtained respecting and dimensions, see picture 8 (opening angle 90 ). Fig. 6 Fig. 7 4

Fig. 8 E 3 TI = max 50 mm E 4 TI = max 250 mm E 4 T = max 200 mm D 90 D 90 Recommended installation (90 opening) + = (motor stroke) ce 3 TI = 300 mm ce 4 TI = 400 mm If the ideal scenario of and is not applicable, refer to the below table to determine the brackets position (values are expressed in mm). Tab. E 3 TI Rear bracket Minimum leaf length E 4 TI Rear bracket Minimum leaf length E 4 T Rear bracket Minimum leaf length 5

3.4.3 OUTWRD OPENING Your gate can be automated for opening outwards too. In this case the value of dimension shall be calculated towards the gate center. See picture 9 and 0 and fit the bracket accordingly. Fig. 9 Fig. 0 90 90 D D 3.5 FSTENING RER RKET T Weld or bolt the rear bracket T on the post, applying the and quota calculated according to the gate hinge position and the motor rotation point. hemical bolts can be used and must comply with the post features (brick, wood, steel, etc. etc.). When fixing keep a minimum distance of 30/35 mm from the post edge in order to avoid damages (see picture ). - Rear brackets T are provided LH and RH, to match to the according LH and RH motor (see picture 2). - When fixing the operator to the rear bracket T, plug PR rotation pin downward oriented (see picture 3). min. 30 35 mm Fig. Fig. 2 Fig. 3 PR 3.6 FSTENING FRONT RKET S3 G 3.6. E TI To determine the position of bracket S3: - Put the gate in closing position. - Release the gearmotor. - Extend the inox pipe arm fully. - Turn back the arm 2 cms. This avoids the motor to leap forward (see picture 4) - ffix the bracket S3 to the motor slot. Plug the rotation pin PR into the locating hole. - Fit the bracket S3 on the gate. - Keep the motor horizontal, fix or weld. Fig. 4 PR 2 cm heck the manual opening of the leaf before definitively fixing the bracket to make sure the gate can open fully to your required angle. S3 G 6

3.6.2 E T To determine the position of bracket S4: - Put the gate in closing position - Release the gearmotor - Slide the front drive pin to the closing limit-switch point (keep a distance of 45 mm between the pin and the pipe end terminal (see picture 5). - Fix the bracket S4 to the drive pin (see picture 6). - Fit the bracket S4 onto the gate and keep the motor horizontal. Fix or weld. Fig. 5 heck the manual opening of the leaf before definitively fixing the bracket to make sure the gate can open fully to your required anglee. 45 mm Fig. 6 S4 M2 4. RELESING THE GERMOTOR - Insert the key and turn it 90 clockwise (see picture 7). - Pull the release handle inwards to unlock the LH motor and outwards to unlock the RH motor. Fig. 7 The gate can be locked in any position after the first start command the system will return to its default settings. 5. MINTENNE LH RH Functional checks must be performed once every 6 months, including: checking the state of lubrication and tightness of the anchoring screws on the operator as well as the good operation of all safety devices. 6. DISMNTLING ND DISPOSL DO NOT DISPOSE OF IN NTURE! Some components may contain hazardous waste. They must, thus, be removed and turned into licensed firms for their disposal. efore acting always check the local laws on the matter. 7

E TI 24V 230V 2 3 26 4 5 9 6 0 9 22 2 8 4 3 2 32 22 7 8 7 6 5 20 30 30 25 30 23 23 24 24 E T 2 3 4 5 9 6 0 39 33 2 35 3 22 2 8 36 32 22 7 38 37 20 25 30 30 30 23 23 24 24 Proteco S.r.l. Via Neive, 77-2050 STGNITO (N) ITLY Tel. +39 073 20 - Fax +39 073 2099 - info@proteco.net - www.proteco.net 8