Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Similar documents
Linear Luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Floodlight LED Series 6125

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight LED Series 6525

Floodlight LED Series 6525

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Tubular Light Fitting with LED Series 6036

Linear Luminaire with LED

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Linear Luminaire for Fluorescent Lamps

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Floodlight Series 6121

Plug and Socket Devices SolConeX 16 A Series 8570

7 Lighting Technology

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Position Switches Series 8060/2

Load disconnect switch Series 8146/5-V11

Position Switches Series 8070/2

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Floodlight Series 6521/4

Compact Sheet-Steel Light Fittings Series 6114

Sheet-Steel Light Fittings Series 6014 / 6414

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Linear fittings EVDL LED fitting - zones 21, & 22

Ex UPS standard Series 8265

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Position Switches Series 8074/2

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Sheet Steel Emergency Light Fitting Series 6018

Terminal Boxes Series 8125

Linear fluorescent luminaire LED V-CG-S

7 Lighting Technology

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Control Buttons / Switches for Panel Mounting Series 8003

Linear fittings EVNL LED fitting - zones 2, & 22

7 Lighting Technology

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

EXEL-L. Detail of the internal side. Transparent polycarbonate

Control switch/load disconnect switch Series 8008

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Load and Motor Switches, Load-Break Switches Series 8549

Operating Instructions

Battery Boxes Series 8316

Emergency Luminaire with LED

7 Lighting Technology

Safety Switches Series 8537

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Load and Motor Switches, Load-Break Switches Series 8544

Control Device System NEC Series ConSig 8040

ellk 92 LED Light Fittings

FHL. Ex d. Body in aluminium

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Control Buttons Series 8082

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Linear fittings EVN Fluorescent fitting - zones 2 & 22

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

EX-RECESSED CEILING LIGHT FITTINGS

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Tank Inspection Lights Series 6122

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Terminal Boxes Series 8252/1

Operating Instructions

Easy and safe installation

Load and Motor Switches, Load-Break Switches Series 8544

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

EX-REPAIR AND MAINTENANCE RECEPTACLES

Transcription:

> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking www.stahl.de 16707E00 The luminaires with LED Series EXLUX 6002 are suitable for general lighting of indoor and outdoor areas. The luminaires with LED were designed for 1 to 1 replacing of luminaires with fluorescent lamps. An equivalent luminous flux by lower energy consumption ensures an increase in efficiency of the lighting system. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Explosion Protection Global (IECEx) Gas and dust IECEx IBE 14.0035 Ex db eb op is IIC T4 Gb Ex tb op is IIIC T100 C Db Europe (ATEX) Gas and dust Certifications and certificates Certificates IBExU 14ATEX1088 E II 2 G Ex db eb op is IIC T4 Gb E II 2 D Ex tb op is IIIC T100 C Db IECEx, ATEX, India (PESO) WebCode 6002C Lighting /1

Selection Table Version Diffusor Length Power Cable entry Order number Weight consumption mm kg EXLUX 6002 with 700 28 W 3x M25 Plastic 6002/2182-5400-5131-0 4.300 Gasgruppe IIC 3x M20 Metal 6002/2182-5400-5232-0 4.300 with 1310 52 W 3x M25 Plastic 6002/2284-5400-5131-0 6.600 3x M20 Metal 6002/2284-5400-5232-0 6.600 Note The light fittings are delivered without mounting material. These accessories must be ordered separately! Technical Data Electrical data Ballast Inrush current Luminous characteristics AC: 110 V... 240 V ±10 %; 50... 60 Hz DC: 110 V... 250 V ±10 % 6002/.1.2-...-...-0 6002/.2.4-...-...-0 Power consumption [W] 28 52 Voltage [V] 230 110 230 110 Frequency [Hz] 50 60 50 60 Power factor > 0.90 > 0.99 > 0.95 > 0.99 THD [%] < 8 < 12 < 6 < 6 I peak = 51 A; Δt = 127 ms maximum number of luminaires per miniature circuit breaker at 230 V: Type 10 A 16 A 20 A 25 A B 8 13 16 20 C 13 22 27 34 K 27 44 55 69 6002/.1.2-...-...-0 6002/.2.4-...-...-0 Power consumption [W] 28 52 Colour rendering [CRI] ) 80 ) 80 Colour temperature [K] 5,000 5,000 without diffuser Luminous flux [lm] 3,000 6,000 Luminaire efficiency [lm/w] 107 115 Ambient conditions Operating temperature range Storage -30... +75 C with diffuser Luminous flux [lm] 2,400 4,650 Luminaire efficiency [lm/w] 86 89 Values apply to T a = +25 C. Luminous flux decrease at T a = +60 C to ) 70 % of the nominal value. during DC operation to 50%. -30... +60 C luminaires without through wiring -30... +60 C luminaires with through wiring; I N ( 10 A -30... +50 C luminaires with through wiring; I N ( 16 A /2 Lighting

Technical Data Service life Service life Mechanical data Degree of protection IP66 / IP67 (IEC 60598) Protection class I (with internal PE connection) Impact strength (IK code) IK10 (IEC 62262) Material Enclosure Material Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Seal Silicone foam gasket in the lamp cover Translucent cover Polycarbonate Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Plastic: 2 x M25 x 1.5 cable glands 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPSM ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Connection T a ( 25 C T a ( 45 C T a ( 60 C L 70B 10C 10 100,000 h 90,000 h 50,000 h L xb yc z At the end of the service life: Luminous flux decrease to "x" percent up to "y" percent of all luminaires fall below "x" up to "z" percent of all luminaires break down completely Standard: Special: Spring clamp terminals 5-pole: L1, L2, L3, N, PE Clamping range: 1 x 0.75... 4 mm 2 (solid / finely stranded) (2 free clamping units per pole available) Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2 x 0.75... 6 mm 2 (solid); 2 x 0.75... 4 mm 2 (finely and extra finely stranded) Through wiring Assembly Standard luminaire Optional with Light fittings are equipped with internal through wiring. Ingoing and outgoing leads can be connected to the opposite sides. Terminals: see techn. data Wiring cross section: 2.5 mm 2 for max. 16 A. without On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires L = 700 mm: 320... 480 mm; L = 1310 mm: 670... 930 mm) Lighting /3

Light Distribution Curves 200 160 400 240 500 16683E00 28 W without diffusor 28 W with diffusor 16723E00 200 160 240 400 16724E00 52 W without diffusor 52 W with diffusor 16725E00 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Bracket for wall mounting with tube kg for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Translucent cover for luminaire L=700 222427 0.639 for luminaire L=1310 222428 1.149 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.026 10809E00 Socket key M8 / wrench size 13; to open/close the central locking 222430 0.210 15507E00 Mounting rail for a variable mounting distance 222826 0.300 15584E00 Mounting bracket mounting clamp mounted on a mounting rail for a variable mounting distance 222456 0.400 15585E00 Pole mounting sleeve for the subsequent mounting on lights 18 W and 36 W, completely with assembly parts 227512 3.200 Pipe clamp 16985E00 R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 R 2 222460 1.300 15583E00 with mounting rail for a variable mounting distance; Material: stainless steel Ring bolt M8, direct mounting in insert nuts, 115736 0.112 05378E00 Ceiling and wallmounting bracket 222827 1.200 15586E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 Lighting /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 15440E00 Dimensions Luminaire 28 W 52 W L1 700 [27.56] 1310 [51.57] L2 1) 400 [15.75] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 670... 930 [26.38... 36.61] b 184 [7.24] 184 [7.24] h1 125 [4.92] 125 [4.92] 1) fixed mounting distance 2) variable mounting distance EXLUX 6002 Standard luminaire Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 30,50 [ 1, 20 ] 12 [ 0, 47 ] 215 [ 8.46] 18,50 [ 0, 73 ] 30 [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] 13 [0,51] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] Mounting rail 15778E00 15779E00 Ring bolt fitted in insert nut of the luminaire 15782E00 15781E00 15783E00 Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail /6 Lighting

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations Wall mounting bracket fitted in mounting rail 15780E00 Bracket for wall mounting with pipe section 03257E00 17755E00 Dimension Light 700 mm 1300 mm L1 978 [38.50] 1587 [62.48] L2 390 [15.35] 338 [13.31] Linear Luminaire EXLUX with pole mounting sleeve We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7