GNS 670 P. Stand-by power: 670 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

C U K U R O V A GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 404D-22G diesel engine Newage/Stamford BCI184E alternator Standard Generator Features

Perkins 1006TAG2 diesel engine Newage/Stamford UCI274F alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

GNS 630 V. Stand-by power: 630 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

GNS 500 V. Stand-by power: 500 kva. Diesel Generating Sets, made for Europe

GNS 400 V. Stand-by power: 400 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GNS 1100 P. Stand-by power: 1100 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

CUKUROVA GENERATOR SYSTEMS

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

204 KW / 254 KVA POWERED by

Perkins 1104C-44TAG2 diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

Perkins 2206A-E13TAG2 diesel engine Newage/Stamford HCI444E alternator Standard Generator Features

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

28 KW / 28 KVA POWERED by

130 KW / 165 KVA POWERED by

CUKUROVA GENERATOR SYSTEMS

55 KW / 70 KVA POWERED by

Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features

Perkins 1103A-33G diesel engine Newage/Stamford BCI184G alternator Standard Generator Features

Perkins 2506A-E15TAG2 diesel engine Newage/Stamford HCI544D alternator Standard Generator Features

64 KW / 80 KVA POWERED by

Perkins 1006TAG diesel engine Newage/Stamford UCI274E alternator Standard Generator Features

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

30 KW / 40 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

Perkins 403D-15G diesel engine Newage/Stamford BCI164C alternator Standard Generator Features

600 KW / 750 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Volvo TAD531GE diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

18 KW / 18 KVA POWERED by

CUKUROVA GENERATOR SYSTEMS

Volvo TAD941GE diesel engine Leroy Somer LSA 46.2 VL12 alternator Standard Generator Features

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

2000 KW / 2500 KVA POWERED by

CUKUROVA GENERATOR SYSTEMS

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

UCDI224F - Technical Data Sheet

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

UCI224C - Technical Data Sheet

UCDI274J - Technical Data Sheet

UCI274H - Technical Data Sheet Winding 06

UCI274H - Technical Data Sheet

UCI274C - Technical Data Sheet Winding 06

HCI634V - Technical Data Sheet

UCI224F - Technical Data Sheet

UCI274D - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274G - Technical Data Sheet

1000 KW / 1250 KVA POWERED by

UCDI224E - Technical Data Sheet

Perkins 4016TAG1A diesel engine Stamford PI734E alternator Standard Generator Features

500 KW / 625 KVA POWERED by

UCDI274K - Technical Data Sheet

300 KW / 375 KVA POWERED by

Perkins TWG2A diesel engine Newage/Stamford PI734B alternator Standard Generator Features

HCI 534C/544C - Technical Data Sheet

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

HCI 434E/444E - Technical Data Sheet

HCI 434D/444D - Technical Data Sheet

HCI 534F/544F - Technical Data Sheet

BCI164C - Technical Data Sheet Winding 06

HCI 534E/544E - Technical Data Sheet

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

HCI 434F/444F - Technical Data Sheet

1800 KW / 2250 KVA POWERED by

HCI634G - Technical Data Sheet

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

80 KW / 100 KVA POWERED by

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

Transcription:

Voltage kva 380-415 400 Prime* kw 320 kva 440 Standby* kw 352 Ampere 557 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model can supply 10% overload power for a period of 1 hour in 12 hours operation as it is defined in ISO 3046. Applicable for supplying continuous power ar variable load in the event of a utility power failure and overload is not allowed as it is defined in ISO 8528-3. Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 6 cylinder, water cooled engine 50 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features Cable drum Working accesories compartment Light tower Protection circuit breaker Air start Remote type radiator External type fuel tank Automatic fuel transfer system Residential silencer Dimensions & Weight Sound Attenuated Dry Weigt Length Width kg mm mm Height mm Tank Capacity L KZM400PS Technical Data Sheet 120824 - Page1

Engine Technical Data Cooling System Manufacturer PERKINS Type Tropical, heavy duty type Model 2206C-E13TAG3 Ambient temperature, C 50 Type 4 cycle, water-cooled Engine + Radiator coolant cap, Lt 51,4 Number of cylinders 6 Cooling fan air flow, m³/min 654 (@50 C) Cylinder arrangement Vertical in-line Jacket coolant flow, Liters/sec 5,2 Displacement, Liters 12,5 Gear driven circulating pump Bore X Stroke, mm 130 X 157 Mounted belt driven pusher fan Compression Ratio 16,3:1 Radiator supplied loose incorporating air to air charge cooler Combustion System Direct injection System designed for ambients up to 50 C Aspiration Turbocharged, air to air cooled Rotation Anticlockwise viewed on flywheel Lubrication System Gross engine power, kwb 412,5 Fan power, kwm 14 Type Pressurized Exhaust gas flow (after turbo),m³ / m72,5 Capacity, Liters 12,5 BMEP gross, bar 2637 Lub oil pressure (min), bar 2 Combustion air flow, m³ / min 26,4 Wet rear well steel sump with filler and disptick Exhaust gas temp.(after turbo), C 630 Full-flow replaceable 'Ecoplus' filter Oil cooler integral with filter header Fuel System Fuel Consumption Type of injection system Fuel injector MEUI MEUI liters per hour %110 Load %100 Load Lift pump delivery, liters / hour 480 %75 Load Governor type Electronic %50 Load Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control grams per kwh %110 Load Replaceable 'Ecoplus' fuel filter elements with primary filter/water seperator Fuel cooler %100 Load %75 Load %50 Load 89 L 81 L 62 L 42 L 196 g/kwh 197 g/kwh 199 g/kwh 202 g/kwh Electrical System Standby kw Prime kw Model Alternator 24 Volt Gross Net Gross Net Starter motor (DC) 24 Volt Starter motor power 7,8kW 2206C-E13TAG3 412,5 392,3 368,4 348,9 Electronic Control Module mounted on engine with wiring looms and sensors Three level engine protection system KZM400PS Technical Data Sheet 120824 - Page2

Alternator Technical Data Optional Equipment Manufacturer STAMFORD Optional Permanent Magnet Generator (PMG) provides an isolated Model HCI444F power supply to the excitation control system Type 4-Poles, Rotating Field, Brushless Anti Condensation Heaters Standby power at rated voltage, kva450 Air Filters Efficiency, % 92,8 Temperature Indication RTD s Power factor 0.8 Winding Protection Thermistors Phase 3 Quadrature Droop kit for Parallel Operation Frequency, Hz 50 SX421 AVR with 3 Phase Sensing and improved Regulation 0.5% Speed, Rpm 1500 MX341 (PMG) 1% Regulation with 2 Phase Sensing Voltage, V 380/415 MX321 (PMG) with 3 Phase Sensing and improved Regulation 0.5% Excitation Self excited Stator windings 2/3 Pitch factor Regulation AVR, Auto Voltage Regulator Terminals&Terminal Box Voltage Regulator SX440 Voltage Regulation, % ± 1 Standard generators feature a main stator with 6 ends brought out to R.F.I Suppression BS EN 61000-6-2,BS EN 61000-6-4 the terminals, which are mounted on the frame at the non-drive end VDE0875G, VDE 0875N of the generator. A sheet steel terminal box contains the AVR and Waveform distortion No Load <1.5% Non distorting balanced provides ample space for the customers wiring and gland Rotor Dynamic balanced arrangements.it has removable panels for easy access. Overspeed, Rpm 2250 Short circuit current < 300% Shaft&Keys TIF Less than 50 Insultion class H All generator rotors are dynamically balanced to better than BS6861 Construction Single bearing, direct coupled :Part 1 Grade 2.5 for minimum vibration in operation. Two bearing Coupling Flexible generators are balanced with a half key. Stator winding Double layer concentric Connection WYE Insulation / Impregnation Protection class IP23 Cooling air volume,m³ / sec 0,8 The insulation system is class 'H' All wound components are impregnated with materials and Winding&Electrical Performance processes designed specifically to provide the high build required for static windings and the high mechanical strength required for All generator stators are wound to 2/3 pitch.this eliminates triplen rotating components. harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.the 2/3 pitch Standards design avoid sexcessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains.a fully Newage Stamford industrial generators meet the requirements of BS connected damper winding reduces oscillations during paralelling. EN 60034 and the relevent section of other international standards such as This winding, with the 2/3 pitch and carefully selected pole and BS5000,VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 tooth designs, ensures very low waveform distortion. Other standards and certifications can be considered on request Quaility Assurance Standby Prime Model Generators are manufactured using production procedures having a quaility kva kw kva kw assurance level to BS EN ISO 9001. HCI444F 450 360 400 320 KZM400PS Technical Data Sheet 120824 - Page3

Deepsea 7320 Control System Description Features Deepsea 7320 is an Auto Mains(Utility) Failure Control module. 4-Line back-lit LCD text display and five key menu navigation The module is used to monitor a mains supply and automaticlly LED and LCD alarm indication start a standby generator set. 9 configurable inputs and 8 configurable outputs The module can also monitor an extensive number of engine Configurable timers, alarms and event log (250) parameters and it can display warnings, shutdown and engine Fuel usage monitor and low fuel alarms status information on the back-lit LCD screen, illuminated LEDs, Charge alternator failure alarm remote PC and via SMS text alerts. Manual speed and manual fuel pump control Selected timers and alarms can be altered by the user from the Engine exerciser and ''Protections disabled'' feature front panel. Alterations to the system are made using the 810 interface and a PC and it also provides real time diagnostic facilities kw overload protection Power monitoring ( kw, h, kv Ar, kv A h, kv Ar h) Load switching (load shedding and dummy load outputs) Automatic load transfer and unbalanced load protection Specification DC SUPPLY Continuous Voltage Rating: 8 V to 35 V Independent Earth Fault trip Support for up to three remote display units and USB connectivity Configurable display languages Maximum Operating Current: 340 ma at 12 V, 160 ma at 24 V Remote SCADA monitoring Maximum Standby Current: 160 ma at 12 V, 80 ma at 24 V User selectable RS232 and RS485 communications Charge Fail/Excitation Range: 0 V to 35 V SMS messaging ( external modem required) Additional display screens to help with modem diagnostics MAINS(UTILITY) & GENERATOR Voltage Range: 15 V - 333 V AC (L-N) Alarm Channels Frequency Range: 3,5 Hz to 75 Hz Under/over generator voltage OUTPUTS Over-current Output A (Fuel): 15 A DC at supply voltage Under/over generator frequency Output B (Start): 15 A DC at supply voltage Under/over speed Output C & D : 8 A 250 V (Volt free) Charge fail Emergency stop Input Functions display on LCD Low oil pressure High engine temperature Generator Volts Volts L1-N, L2-N, L3-N Fail to start Generator Volts Volts L1-L2, L2-L3, L3-L1 Low/high DC battery voltage Generator Amps Amps L1, L2, L3 Reverse power Generator Frequency Hz Generator phase rotation error Mains Volts Volts L1-N, L2-N, L3-N Generator short-circuit protection Mains Volts Volts L1-L2, L2-L3, L3-L1 Loss of speed sensing signal Mains Frequency Hz Mains out of limits Engine Speed RPM Plant Battery Volts Volts Optional Input Functions Engine Hours Run Hour Generator total power kva L1, L2, L3,total Engine Oil pressure kpa Generator total power kw L1, L2, L3,total Fuel level % Generator power factor Cosφ L1, L2, L3,total Engine Temperature C KZM400PS Technical Data Sheet 120824 - Page4

Model Codes and General Information Kunz Diesel Generator KZ M 400 P S Alternator Make-Stamford Engine Make-Perkins Prime Rating - kva Mobile type KUNZ diesel generator Perkins 2200 Series Diesel Engine Newage / Stamford Alternator 2206C-E13 T A G 3 HC I 44 4 F Power level Genset engine Air to air charge cooled Turbo charged Electronic 8,7 liters Core Length Number of poles Shaft Height in cm Industrial Generator type 1300 Series, 6 cylinder KZM400PS Technical Data Sheet 120824 - Page5