CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

Similar documents
CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

Grundfos pump

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CRE32-3 AN-F-A-E-HQQE 3x HZ

CRE A-F-A-E-HQQE 3x HZ

CR A-F-A-V-HQQV 3x400/ HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CRE15-01 A-F-A-E-HQQE 1x HZ

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR A-F-A-V-HBQV 3x400/ HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

CR45-3 A-F-A-E-HQQE 3x400/ HZ

NB /193 A-F2-A-BAQE

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CRN5-5 A-FGJ-G-V-HQQV 3x230/400 50HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

Hydro MPC-E 2CRIE L GNL

TP /4-A-F-A-BQQE 400Y 50HZ

CRE A-F-A-E-HQQE 3x HZ

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

CRN A-F-G-V-HQQV 3x400/ HZ

TP /2-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BUBE 400Y 50HZ

CRE20-08 A-F-A-E-HQQE 3x HZ

NK /310A2F1AE-SBAQE

CRN5-22 A-P-G-V-HQQV 3x400D 50HZ

CRN1S-9 A-P-G-V-HQQV 3x230/400 50HZ

TP /2-A-F-A-BAQE 400D 50HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

NB80-160/161 A-F2-A-BQQE

NB /263 AS-F2-A-BAQE

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

NB /438 A-F1-A-GQQE

NK40-160/172A1F2AE-SBAQE

CRN1S-21 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

TP /2-A-F-A-BQQE 400D 50HZ

TP 32-90/2-A-O-A-BQQE 400Y 50HZ

TP 25-80/2-A-O-A-BQQE 400Y 50HZ

NBE50-250/205 A-F2-A-BAQE

CM1-6 A-R-I-E-AQQE F-A-A-N

Transcription:

GRUNDFOS DATA BOOKLET CR3-19 A-FGJ-A-E-HQQE 3x23/4 5HZ Grundfos Pump 96516663 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96516663/cr-3-19-a-fgj-a-e-hqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CR 3-19 A-FGJ-A-E-HQQE Product No.: 96516663 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via combined DIN-ANSI-JIS flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. Further product details The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. The pump head, pump head cover and flange for motor mounting is made in one piece. The pump head has a combined 1/2" priming plug and air vent screw. 1/9

The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The shaft seal is screwed into the pump head. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The base is made of cast iron. The flanges and base are cast in one piece. The discharge side of the base has a combined drain plug and bypass valve. The pump is secured to the foundation by four bolts through the base plate. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with tapped-hole flange (FT). Motor mounting designation in accordance with IEC 634-7: IM B 14 (Code I) / IM 361 (Code II). Electrical tolerances comply with IEC 634. The motor efficiency is classified as IE3 in accordance with IEC 634-3. The motor does not incorporate motor protection and must be connected to a motor-protective circuit breaker which can be manually reset. The motor-protective circuit breaker must be set according to the rated current of the motor (I1/1). 2/9

The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Win-/WebCAPS. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: Water 253.. 393 K 293 K 998.2 kg/m³ 2896 rpm 3 m³/h 92.5 m HQQE CE,TR ISO 996:1999 Annex A Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 25 bar / 12 C 25 bar / -2 C Flange standard: DIN Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT115 Electrical data: Motor type: 9SB IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 1.5 kw Power (P2) required by pump: 1.5 kw 1.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24 D/38-415 Y V Rated current: 5,45/3,15 A Starting current: 85-93 % Cos phi - power factor:,87-,82 Rated speed: 289-291 rpm Efficiency: IE3 84,2% Motor efficiency at full load: 84,2-84,2 % Motor efficiency at 3/4 load: 84,5-83,9 % Motor efficiency at 1/2 load: 83,1-81, % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F 3/9

Position Qty. Description Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 41.1 kg Gross weight: 45.2 kg Shipping volume:.8 m3 4/9

96516663 CR 3-19 5 Hz H [m] CR 3-19, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 13 12 11 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 3.6 3.8 4. 4.2 4.4 P [kw] Q [m³/h] NPSH [m] P1 1.5 6 P2 1. 4.5 2. 5/9

Description Value Product name: CR 3-19 A-FGJ-A-E-HQQE Product No: 96516663 EAN number: 57396747491 Technical: Speed for pump data: 2896 rpm Rated flow: 3 m³/h Rated head: 92.5 m Head max: 126 m Impellers: 19 Shaft seal: HQQE Approvals on nameplate: CE,TR Curve tolerance: ISO 996:1999 Annex A Pump type: CR 3 Stages: 19 Pump version: A Model: A H [m] 13 12 11 9 8 7 6 5 4 3 2 1 P [kw] 1. CR 3-19, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³.5 1. 1.5 2. 2.5 3. 3.5 4. Q [m³/h] P1 P2 eta [%] 9 8 7 6 5 4 3 2 1 NPSH [m] 4 Materials: Pump housing: Impeller: Material code: Code for rubber: Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 A E.5. 19 x 24.5 ø14 ø ø89 4 x ø13.5 ø35 18 22 2 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 25 bar / 12 C 25 bar / -2 C Flange standard: DIN Connect code: FGJ Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT115 11 178 589 281 G 1/2 75 2 141 25 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 393 K 293 K 998.2 kg/m³ Electrical data: Motor type: 9SB IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 1.5 kw Power (P2) required by pump: 1.5 kw 1.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24 D/38-415 Y V Rated current: 5,45/3,15 A Starting current: 85-93 % Cos phi - power factor:,87-,82 Rated speed: 289-291 rpm Efficiency: IE3 84,2% Motor efficiency at full load: 84,2-84,2 % Motor efficiency at 3/4 load: 84,5-83,9 % Motor efficiency at 1/2 load: 83,1-81, % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Motor protec: NONE LOW VOLTAGE DIRECTION OF ROTATION L3 L2 L1 HIGH VOLTAGE DIRECTION OF ROTATION L1 L2 L3 6/9

Description Motor No: Value 85U596 Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 41.1 kg Gross weight: 45.2 kg Shipping volume:.8 m3 7/9

96516663 CR 3-19 5 Hz 11 178 75 589 281 G 1/2 19 x 24.5 ø89 ø ø14 141 25 2 18 22 ø35 4 x ø13.5 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

96516663 CR 3-19 5 Hz LOW VOLTAGE DIRECTION OF ROTATION L1 L2 L3 HIGH VOLTAGE DIRECTION OF ROTATION L1 L2 L3 Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89