S-PRO 3200 GC System for Sulfur Analysis

Similar documents
Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Beverage Grade Carbon Dioxide

C2, C3, C4 Monomer Analysis

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

Collection & Analysis of Reduced Sulfur Compounds in Air

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

TSHR 6000 series TN/TS/TX analyzer

Antek Gas Chromatography Products: A Guided Tour Through Industry

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Monitor Chlorine in Crude at Sub-ppm Levels

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Using the PSD for Backflushing on the Agilent 8890 GC System

ANTEK APPLICATED Turn-Key GC solutions

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

A Look at Gasoline Sulfur Reduction Additives in FCC Operations

GC Method Compliance and Large Valve Oven Application

Agilent Multimode Inlet for Gas Chromatography

DANI Transformer Oil Gas Analyzer

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices

GAS CHROMATOGRAPHY LGC-A1 SERIES

Application. Gas Chromatography June 1995

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

PSF REFORMULATED FUEL REPORT OF REFORMULATED GASOLINE UTILIZING RAW FUEL FROM FCC REFINERY UNIT

Experience the Difference

performance productivity reliability

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

better analysis counts

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

TSHR 7000 series TN-TS-TX analyzer

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Are You Prepared For Tier 3 Gasoline Standards? Presented by: Shaun Spiro and Leslie Johnson

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Application Note. Abstract. Authors. Environmental Analysis

breakthrough versatility

Prodigy ICP Application Note: # 1039

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Speciation of Sulfur-Containing Compounds in Diesel by Comprehensive Two-Dimensional Gas Chromatography

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Refinery and Natural Gas Analysis

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

Analysis of Petroleum Fractions by ASTM D2887

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Zeolite Catalyst. Methanol. Propylene. Petrochemical Research & Technology پژوهش و فناوري پتروشیمی

Distillation process of Crude oil

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Technical Procedure for Gas Chromatography (GC-FID)

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Low Carbon Footprint Adsorptive Technology for ULSD Production

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

GTC TECHNOLOGY. GT-BTX PluS Reduce Sulfur Preserve Octane Value - Produce Petrochemicals. Engineered to Innovate WHITE PAPER

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector


ASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Gary Stidsen Jaap de Zeeuw

Shimadzu's Total Solutions for the Hydrocarbon Processing Industry

RIGHT SOLUTIONS RIGHT PARTNER

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Application Note. Authors. Abstract. Energy & Chemicals

On-Line NIR Analysis for Blending

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

Molecular Sieves Application Guide for the Natural Gas Industry Molecular Sieve Molecular Sieve Recommendations

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

HIGH PRESSURE SWITCHING VALVES

Refining/Petrochemical Integration-A New Paradigm Joseph C. Gentry, Director - Global Licensing Engineered to Innovate

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Operation and Applications of Differential Flow Modulation

Elemental Analysis Advanced

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Maximizing Refinery Margins by Petrochemical Integration

Agilent and ASTM. Update on Recent Activities. Page 1

Refining/Petrochemical Integration-A New Paradigm

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

The Role of the Merox Process in the Era of Ultra Low Sulfur Transportation Fuels. 5 th EMEA Catalyst Technology Conference 3 & 4 March 2004

Report. Refining Report. heat removal, lower crude preheat temperature,

Specifications for Refrigerants

Transcription:

S-PRO 32 GC System for Sulfur Analysis

Superior Selectivity and Sensitivity The ability to detect and measure sulfur contaminants in gases is critically important for efficient operation of industrial processes and to control product quality. S-PRO 32 GC systems have proven highly effective in demanding sulfur analysis applications. Sulfur content in Liquefied Petroleum Gas (LPG) COS in ethylene and propylene feedstock Sulfur in natural gas Impurities in beverage grade CO 2 Semiconductor and industrial gas purity Quality control in gas production and blending operations Gas and Liquid Phase Petrochemicals Carbonyl Sulfide in Propylene (ASTM D533) Sulfur Compounds in Natural Gas (ASTM D554 & D6228) Ultra-Low sulfur Gasoline (ULSG) Ultra-Low sulfur Diesel (ULSD) Thiophene in Benzene (ASTM D4735-2 & D711) Sulfur Compounds in Light Petroleum Liquids (ASTM D5623) Jet Fuel Naphtha Crude & Synthetic Oils Furnace Oil Light Cycle Oil (LCO)

Ethylene and Propylene Feedstock Propylene is a co-product from steam cracking of ethylene. Carbonyl sulfide (COS) is a major contaminant in propylene feedstock and can destroy expensive catalyst beds used in polymer production and other processes if not removed. The accompanying chromatograms show the hydrocarbons and COS present in a feedstock gas before separation of propylene and ethylene components, and prior to sulfur scrubbing. na 175 15 125 1 75 5 25-25 na 4 3 2 1 Sulfur Channel COS (> 5-ppm) 2 4 6 8 1 12 14 16 18 Hydrocarbon Channel Methane Ethane Ethylene Acetylene Propylene min 2 4 6 8 1 12 14 16 18 min Natural Gas Natural gas containing hydrogen sulfide or mercaptans is referred to as sour gas. The concentration of hydrogen sulfide in natural gas ranges from barely detectable levels to more than.3% (3, ppm). 1 unknown 4 3 2 1 Sulfur Channel 3.4-ppmv H 2 S ~1-ppbv sulfur unknown 4 Hydrocarbon Channel C5s + 3 2 1 C1 C2 C3 C4s Sulfur Impurities in CO 2 Early detection and control of H 2 S and COS is an important consideration in the production of food-grade CO 2 because the presence of these compounds can impart undesirable odors and flavors to carbonated beverages. uv 42 4 38 36 34 32 3 Sulfur Standard in CO 2 Hydrogen sulfide Carbonyl sulfide Methyl mercaptan Ethyl mercaptan Carbon disulfide Propyl mercaptan 28 26 2 4 6 8 1 12 m 1. The Chemistry and Technology of Petroleum, Marcel Dekker, Inc., 1991.

Advanced Detection Technology The S-PRO 32 is a custom-configured gas chromatograph for selective, high-sensitivity measurement of sulfur compounds in gas-phase samples and Liquefied Petroleum Gas (LPG) streams such as propylene and ethylene. S-PRO 32 Gas Chromatograph The key technology within the S-PRO 32 system is OI Analytical s patented* Pulsed Flame Photometric Detector (PFPD). Our Model 5383 PFPD has a linear, equimolar response to sulfur allowing selective measurement of individual sulfur species from low ppb to ppm levels, and total sulfur as the sum of individual peaks. The unique capability to obtain simultaneous sulfur and hydrocarbon chromatograms from a single PFPD detector sets it apart from other sulfur detection technologies. Reliable and cost-effective, the 5383 PFPD uses significantly less gas than SCDs or FPDs and requires less maintenance. Thirteen Light Sulfur Compounds in a Propylene Standard on the S-PRO 32 1 1. COS 2. H 2 S 3. Propylene 4. CS 2 5. Methylmercaptan 6. Ethylmercaptan 7. Thiophene 8. DMS 9. 2-Propanethiol 1. 1-Propanethiol 11. 2-Methyl-2-propanethiol 12. 2-Methyl-1-propanethiol 13. 1-Methyl-1-propanethiol 14. 1-Butanethiol 2 3 4 5 6 7 8 9 1 11 12 13 14

PFPD Principle of Operation A combustible mixture of H 2 and air is introduced and fills the detector body and cap from the bottom up (1). The combustion mixture is ignited in the cap (2). The resulting flame propagates along the pathway consuming the H 2 /air mixture (3). Compounds eluting from the GC column are combusted within a quartz combustor and emit light at element-specific wavelengths (4). The flame is extinguished when it reaches the bottom of the detector, and excited species continue to fluoresce for up to 25 milliseconds. Emissions from the excited species pass along a light pipe, and selected emissions are transmitted through an optical filter to a photomultiplier tube for detection (5). The entire pulsed flame cycle is repeated approximately 3 to 4 times per second. 1 2 3 4 5 Light pipe PMT Optical filter PFPD Pulsed Flame Photometric Detector The PFPD is widely used in laboratory and process gas chromatographs to analyze sulfur species and total sulfur levels in liquid-phase petrochemicals. Gasoline unknown 6 5 4 3 2 1 15 µv 6 5 4 3 2 1 5-ppm total sulfur B C D E G H 5 1 15 2 25 3 35 min Hydrocarbon Channel I Sulfur Channel No interference from HC background 5 1 15 2 25 3 35 min 1-µL injection; split 1:1. Concentration reported by client as 5 ppm. A Methyl mercaptan B Thiophene C C1-Thiophenes D Tetrahydrothiophene E C2-Thiophenes F C3-Thiophenes G Benzothiophene H C1-Benzothiophenes I C2-Benzothiophenes J C3-Benzothiophenes K Dibenzothiophene L C1-Dibenzothiophenes M C2-Dibenzothiophenes N C3-Dibenzothiophenes O Alkyl sulfides & substituted thiophenes Diesel Fuel 15 µv 1 8 6 4 2 15 µv 5 4 3 2 1 Sulfur Channel A Methyl mercaptan L B Thiophene 29-ppm total sulfur C C1-Thiophenes M D Tetrahydrothiophene E C2-Thiophenes K F C3-Thiophenes N G Benzothiophene H C1-Benzothiophenes I C2-Benzothiophenes 1 2 3 4 5 min J C3-Benzothiophenes K Dibenzothiophene Hydrocarbon Channel L C1-Dibenzothiophenes M C2-Dibenzothiophenes N C3-Dibenzothiophenes O Alkyl sulfides & substituted thiophenes

The Complete Solution for Sulfur Analysis Chemically-Inert Components Volatile sulfur compounds such as H 2 S, methyl, and ethyl mercaptan adsorb strongly to the surfaces of untreated metals. The entire sample pathway of the S-PRO 32 is constructed with Sulfinert or SilcoNert 2 treated components to prevent adsorption of sulfur compounds that could cause inaccurate results. Permeation Oven Generates gas-phase calibration and QA/QC check standards at point of use Volatiles Interface Allows wide dynamic range Automated Injection System Automates sample introduction, system calibration, and QC checks Pulsed Flame Photometric Detector Produces simultaneous, mutually selective sulfur and hydrocarbon chromatograms

OI Analytical has integrated a number of special design features into the Agilent 789 GC platform to provide unique analytical and performance capabilities. Permeation Oven Accommodates up to 5 permeation devices Pure sulfur compound diffuses across a permeable Teflon barrier at a temperature-dependent rate Precise oven temperature control produces a constant diffusion rate Controlled, measured flow of dilution gas creates an accurate gas standard for calibration Agilent 789B keypad- or ChemStation-controlled temperature and dilution gas flow Aux EPC Compound Diffuses Out at a Constant Rate R = ng/(min*cm) Filled with Compound Permeation Device Teflon Membrane Known Gas Known Constant Flow Rate Concentration IN OUT Permeation Oven Constant Temp 3 75 C Automated Injection System 4-port sample selection valve enables sample selection from a gas stream, or to deliver calibration and check standards from the permeation oven 6-port gas-phase switching valve with sample loop injects samples through the Volatiles Interface into the GC column Sulfur Detection PFPD Superior sensitivity and increased selectivity compared to conventional FPDs Better long-term stability and less maintenance than SCD or XRF Quick, easy calibrations Self-cleaning design Volatiles Interface Optimized for ultralow dead volume flow rates, inertness, and ease of column installation Sample Line In Split Vent GC Oven Interior Low Volume Injector Body (Sulfinert) Top of GC Oven

S-PRO 32 Specifications Detectivity Selectivity Permeation Oven OI Volatiles Interface GC Column Sulfur < 1 pg S/second At optimum detectivity levels: Sulfur > 1 6 S/C Temperature range: 3-75 C ±.5 C Effective split range: Splitless to 15-to-1 Maximum temperature: 325 C Agilent J&W Select Low Sulfur Column, 8 m x 32 mm ID Maximum temperature: 26 C 5383 PFPD Specifications Detectivity Sulfur Phosphorus <1 pg S/sec <1 fg P/sec Sensitivity Sulfur Signal-to-Noise Drift (S or P) >3 (at 1 pg S/sec elution rate peak-to-peak noise) <1x peak-to-peak noise in 2 min Selectivity (at Optimum Detectivity Levels) Sulfur >1 6 S/C Phosphorus >1 5 P/C (selectivity is adjustable with a trade-off in detectivity) Detector Linearity Sulfur Phosphorus Response Uniformity Chromatographic Peak Tailing Quadratic in response; linear to approximately 2.4 orders of magnitude Detector (nonlinear) dynamic range ~3 orders of magnitude First order linear over approximately 5 orders of magnitude Equimolor ±8% (S,P) <.2 sec in S and P 151 Graham Road PO Box 91 College Station, Texas 77842-91 (979) 69-1711 (8) 653-1711 USA/Canada FAX (979) 69-44 www.oico.com E-mail: oi-info@xyleminc.com Publication 17116 216 Xylem Inc. OI Analytical is a trademark of Xylem, Inc., or one of its subsidiaries. Sulfinert is a registered trademark of Restek. SilcoNert is a registered trademark of SilcoTek. Teflon is a registered trademark of the DuPont company. * U.S. Patent 5,153,673