IGS Iranian Gas Standards

Similar documents
IGS-IN-301(1) : National Iranian Gas Co. Research and Technology Management. Standardization Division IGS. Iranian Gas Standards

MATERIAL AND EQUIPMENT STANDARD FOR ABRASIVE AIR BLASTING MACHINE ORIGINAL EDITION MARCH 1996

SECTION H3 TRAYMASTER SERIES DEAERATORS

Vertical & Horizontal Bladder Tank Foam Storage Devices Model MXC

SECTION H4 BOILERMATE DEAERATORS

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

VENT SILENCER PRODUCT GUIDE

SAMPLE SPECIFICATIONS

PTFE Lined Pipe and Fittings

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

VERSAFLOW MAG 4000 Quick Start

CROSBY STYLE JB PRESSURE RELIEF VALVE

Vertical Pre-Piped Bladder Tanks with Proportioner

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

Horizontal Pre-Piped Bladder Tanks with Proportioner

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

MATERIAL AND EQUIPMENT STANDARD FOR POSITIVE DISPLACEMENT PUMPS - ROTARY SECOND EDITION DECEMBER 2012

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

* Contact your sales representative for compliance to NACE MR or later requirements.

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

HORIZONTAL BLADDER TANKS

MAINTENANCE GUIDELINES FOR NIBCO ¼ THROUGH 3 CLASS 125, 150, 200 & 300 BRONZE SWING CHECK VALVES FIGURE NUMBERS

Technical Specifications

SPECIFICATIONS FOR MOTOR OPERATED VALVES

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

026-2 : 1996 CEB STANDARD

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

SOLENOID CONTROL VALVE

Installation, Operation, and Maintenance Manual

IOM Manual. IOM Manual. Series 76/77.

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

Date of Addendum Issue: Effective Addendum Date: Affected Publication: ADDENDUM 2

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

Crosby Style JQ pressure relief device

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

* Contact your sales representative for compliance to NACE MR or later requirements.

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

DIVISION 14 CONVEYING EQUIPMENT

SPECIFICATION FOR AUTOMATIC PRIMING AND OPERATING SYSTEM FOR CENTRIFUGAL PUMPS.

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

TECHNICAL BULLETIN Top Entry Cryogenic Ball Valve Standard & Full Port

Baumann 24000F Wafer Control Valve

Baumann Sanitary Angle Control Valve

Baumann Series Sanitary Regulators

شركت ملي گازايران مديريت پژوهش و فنآوري امورتدوين استانداردها IGS مشخصات فني خريد شيرهاي قفل شونده قبل از رگولاتور جهت انشعابات شبكه هاي گاز فولادي

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

Pressure Relief Valves Series. Consolidated Safety Valve

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Baumann Sanitary Diaphragm Angle and Inline Control Valve

SR100 Series Service Regulators. Technical Bulletin

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

IGS-M-CH-051-1(0) Jan مصوب. Approved IGS. Molecular Sieve, Type 3A

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.

Solutions beyond products...

BUCKEYE LEGACY POLISHED CONCRETE ENHANCER & PROTECTANT MODEL SPECIFICATION

TECHNICAL DATA. Table Standard Materials

Val-Matic QuadroSphere Trunnion Mounted Ball Valve

Ball Valves. Quality Valves at Low Cost

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

Crosby Style JQ pressure relief device

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Series Pilot Operated Pressure Relief Valves 0810C

Paramax Series Control Ball Valve. Specification Data CM6004 7/97

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Series 240 Type 3351 Pneumatic On/off Valve

RPM Series Rotary Meter C-Class

INSTALLATION AND OPERATING MANUAL

Installation & Design Maintenance for ILBP System

Baumann Mikroseal Control Valve

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

TOSACA. Catalogue

HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3

approved IGS Polyethylene Valves Fax:(9821)

Safety Relief Valves Commanche Techmatic Controls

Baumann Little Scotty Bronze Control Valve

CUSTOM COMBINATION AIR VALVE

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

GW C300 AUTOMATIC WATER CONTROL VALVE PRESSURE REDUCING WITH SOLENOID (electrical actuation)

TECHNICAL DATA. Table Standard Materials

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

TECHNICAL SPECIFICATIONS FOR BATTERY OPERATED HEAVY DUTY FORK LIFT TRUCK - 20 T

KNIFE GATE VALVES -- MODEL D

TABLE OF CONTENT

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION CLIENT : MCM

TECHNICAL DATA. VERTICAL AND HORIZONTAL BLADDER TANKS MODEL VFT ASME Sec.VIII Div.1 - U-1A

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SUGGESTED SPECIFICATIONS

TECHNICAL MANUAL MT064

Electromagnetic flowmeters

City of Ottawa Street Lighting. HID Shoebox Style Luminaire

Transcription:

IGS-M-PM-101(0) 1996 APPROVED IGS Iranian Gas Standards!" #$% & '($) '*+,( Odorizer, Injection Type. Fax:(9821)-8131-5679,,-. /012-3 45,627849:2 ;<4:6, =7>-?9@3 /AB8 C<-DE /F GHI 45,627849:2J2 =,4K9:2 L2-F http://igs.nigc.ir/igs igs@nigc.ir

1. SCOPE Odorizer, Injection Type 1.1 THIS SPECIFICATION COVERS THE MIN. REQUIREMENTS FOR DESIGN, MATERIAL, FABRICATION, INSPECTION, MARKING, PACKING AND SHIPPING OF PACKAGED ELECTRONIC INJECTION TYPE GAS ODORIZER AND THE REQUIRED INSTRUMENTATION TO BE USED IN NATURAL GAS PRESSURE REDUCING STATIONS. IN CASE OF ANY DEVIATION FROM THIS SPECIFICATION IT SHALL BE CLEARLY STATED ON TECHNICAL QUOTATION. 1.2 WHENEVER NECESSARY ADDITIONAL PROVISIONS TO THE FOLLOWING STANDARDS AND CODES ARE STATED WHICH SHALL BE CONSIDERED AS INTEGRAL PARTS OF THIS SPECIFICATION. 1.3 ODORIZERS SHALL BE DESIGNED TO BE OPERATED UNATTENDEDLY FOR THE FULL RANGE OF GAS FLOW AS STIPULATED IN DATA SHEET. 2. CODES & STANDARDS WHERE THE FOLLOWING STANDARDS ARE REFERRED TO ONLY THE LATEST EDITION OF EACH STANDARD STANDS VALID FOR APPLICATION. 1. PIPE FLANGES & FLANGED FITTINGS : ANSI B 16.5 2. FORGED STEEL FITTINGS, THREADED ANSI B 16.11 3. FORGED STEEL FITTINGS, SOCKET WELDING ANSI B 16.9 4. GASKETS : ANSI B 16.20 5. BOLTING : ANSI B 18.2 AND B 2.2 6. GAS TRANSMISSION AND DISTRIBUTION PIPING SYSTEM ASME / ANSI B 31.8 7. PRESSURE PIPING : ANSI B 31.3 8. PRESSURE VESSEL : ASME SECTION VIII DIV. I 9. ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES : BS 5501 PART 6 3. GENERAL REQUIREMENTS 1

3.1 THE ODORIZER SHALL BE DESIGNED AND FABRICATED TO BE SUITABLE FOR OUT DOOR INSTALLATION AND FOR THE MOST ADVERSE ENVIROMENTAL CONDITION OF OPERATION THROUGH OUT THE YEAR. 3.2 ODORANT TANK SHALL BE MADE OF CARBON STEEL ASTM A 516, GR. 70 INTERNALLY COATED WITH MIN 300 MICRONS OF EPOXY ( PRIMER + UNDERCOAT + 2 FINISH COATS ) ACCORDING TO N.I.O.C STANDARDS : IPS - M TP 215, 220 & 225 ( 1993 ). 3.3 ALL ODORIZER UNITS SHALL BE ACCOMODATED WITH LIFTING FACILITIES FOR HANDLING AND TRANSPORTATION PURPOSES. 3.4 FABRICATION OF ODORIZER SHALL NOT BE COMMENCED PRIOR TO RECEIPT OF DRAWING AND DESIGN CALCULATIONS APPROVAL FROM THE PURCHASER. 3.5 ALL PRESSURE PARTS AND NON REMOVABLE AND EXPOSED TO THE CONTAINED MEDIA SHALL HAVE THE CORROSION ALLOWANCE OF 3/16 IN. ADDED. 3.6 STORAGE TANK WILL BE FABRICATED & SUPPLIED LOCALLY AS PER PARA 2. 3.7 SUPPLIER OF ODORIZER SHALL PROVIDE THE CLIENT WITH ALL DRAWINGS AND TECH. INFORMATION REQUIRED FOR FABRICATION OF ODORANT STORAGE TANK, ATTACHMENTS, FITTINGS ETC. PRIOR TO START OF MANUFACTURING THE ODORIZER UNIT. 3.8 ODORANT TANK SHALL HAVE A DEPRESSURIZING VALVE AND AN APPROPRIATE CHARCOAL FILTER. 3.9 THE LOCATION AND MINIMUM SIZE OF ATTACHMENT WELD FROM NOZZELS AND OTHER CONNECTIONS SHALL CONFORM TO REQUIREMENTS DEFINED IN THE APPLICABLE SPECIFIED CODES IN THIS STANDARD AND ANY NECESSARY CORROSION ALLOWANCE FOR THE ABOVE ATTACHMENTS SHALL GENERALLY CONFORM TO THE APPLICABLE PARTS OF THE SAME CODES. 3.10 OPENINGS IN SHELL AND HEAD SHALL BE CONSIDERED IN ACCORDANCE WITH THE APPLICABLE CODES AND SHALL BE ADEQUATE FOR PRESSURE AND TEMPERATURE 2

AND BE STAMPED ON THE VESSEL. VESSELS CORRODING THICKNESS IN EXCESS OF THE REQUIRED DESIGN OR MINIMUM CODE THICKNESS SHALL NOT BE CONSIDERED IN THE DESIGN OF OPENING REINFORCEMENT UNDER OPERATING CONDITIONS. TELL TALE HOLES SHALL BE PROVIDED IN ACCORDANCE WITH ASME SECTION VIII DIVISION I.UG 25 ( e ). 3.11 INSPECTION DOOR TO BE PROVIDED FOR ODORANT TANK. 3.12 THE ODORIZER SHALL BE SELF SUPPORTING BY MEANS OF EITHER SKID MOUNTED OR LEGS SUPPORTED PROVISIONS WHICHEVER MOST APPROPRIATE. 3.13 A 316 STAINLESS STEEL SEAMLESS TUBING SHALL BE USED THROUGHOUT THE UNIT 3.14 ODORANT TANK SHALL BE SIZED BIG ENOUGH TO HOLD THE FULL QUANTITY OF ODORANT REQUIRED FOR ONE MONTH CONTINUOUS OPERATION OF CITY GATE STATION AT MAX. FLOW RATE AS STATED IN THE DATA SHEET. ( MIN. TANK CAPACITY = 300 LITERS ) 3.15 THE ODORIZER SHALL BE DESIGNED TO INJECT THE SPECIFIED DOZE OF ODORANT INTO GAS LINE PROPORTIONAL TO THE FLOW RATE FOR FULL RANGE OF OPERATION. 3.16 MAXIMUM WORKING PRESSURE OF ODORANT TANK SHALL BE 30 PSI. 3.17 ALL ODORIZERS SHALL BE SUPPLIED COMPLETE WITH VALVES, FITTINGS ODORANT LOADING FACILITIES AS SCHEMATICALLY SHOWN IN APPENDIX B. 3.18 ALL CONTROLS COMPONENTS OF ODORIZERS SHALL BE FITTED IN AN EXPLOSION PROOF CONTROL BOX. 3.19 FOR INSTALLATION AND OPERATION PURPOSES UP TO 7 METERS FROM THE MANI LINE, APPROPRIATE ST.STL. TUBES AND FITTINGS SHOULD BE SUPPLIED. 3.20 FIVE MICRON FILTER SHALL BE PROVIDED UPSTREAM THE INJECTION PUMP. 3.21 EACH ODORIZER SHALL BE ACCOMODATED WITH A MEASURING BURRETTE SUITABLE FOR PUMP CALIBRATION AND ALSO TANK LEVEL INDICATION. IT SHALL 3

STAND CLEAR AGAINST ODORANT EFFECTS AND SUN RAY AND BE PROTECTED BY A PROPER GUARD. 3.22 ALL ASSOCIATED COMPONENTS IN CONTACT WITH ODORANT SHALL BE RESISTANT TO ODORANT. 3.23 THE PUMP SHALL BE SO SIZED AS TO MEET THE MAX. INJECTION RATE OF 25 MG. OF ODORANT PER STANDARD CUBIC METER OF GAS FLOW. 3.24 CONTROL SHALL BE MADE BY USING SIGNALS, RECEIVED FROM THE METER ( TURBINE OR ORIFICE AS SPECIFIED IN DATA SHEET ) TO CONTROL THE PUMP. EACH ODORIZER SHALL BE ACCOMODATED WITH AN EMERGENCY PULSE GENERATING UNIT IN CASE OF ANY FAILURE DEVELOPED IN THE MAIN PULSE GENERATION SYSTEM THE EMERGENCY PULSE GENERATING UNIT WILL UNDERTAKE THE DUTY BY MANUAL STARTING OF THE UNIT. 3.25 THE PUMP SHALL BE SOLENOID DRIVEN GLANDLESS HYDRAULIC DIAPHRAGM TYPE. 3.26 AN INJECTION NOZZLE, TO BE FITTED TO THE MAIN LINE, MADE FROM ST.STL. SHALL BE PROVIDED FOR EACH UNIT. 3.27 THE NOZZLE SHALL BE SUPPLIED TOGETHER WITH A ¾ ( FOR FLOW RATE OF 50000 SCMH PLUS ) OR ½ ( FOR FLOW RATE OF 50000 SCMH MINUS ) BALL TYPE NONRETURN VALVE AND A SUITABLE STOP VALVE AND AN INJECTION PERFORATED TUBE FILLED WITH FELT OR ST.STL. GAUZE TO ALLOW A UNIFORM DISPERSION OF ODORANT INTO GAS FLOW. 3.28 PUMP, CONTROL CABINET AND AUTOMATIC / MANUAL CHANGE OVER SWITCH SHALL BE SUPPLIED EXPLOSION PROOF IN ACC. WITH CLASS EEX e II T4. 3.29 THE CONTROL SYSTEM SHALL INCORPORATE BUT NOT LIMITED TO, THE FOLLOWING ITEMS. - PULSE DIVIDER ( IF NECESSARY ). - CHANGE OVER SWITCH FOR SWITCHING OVER SIGNALS FROM FLOW METER TO THE EMERGENCY PULSE GENERATOR. - EMERGENCY PULSE GENERATOR. 4

3.30 THE SYSTEM SHALL BE DESIGNED & SUPPLIED TO BE POWERED BY USER S 220 +/- %10 V.AC. 50 HZ. 1 PH. FEED. 3.31 POWER CONTINIUTY WILL BE ACCOMPLISHED BY FACILITIES PROVIDED BY USER OF THE ODORIZER SYSTEM. 3.32 UPS SYSTEM IS DESIGNED & SUPPLIED BY LOCAL SOURCES ON THE BASIS OF THE DATA GIVEN BY ODORIZER S SUPPLIER. 3.33 UPS WILL BE DESIGNED & SUPPLIED IN ACCORDANCE WITH THE IRANIAN PETROLUM STANDARD, SPECIFICATION NO.IPS M EL 176 ( 0 ) DATED JULY 1994. 3.34 RANGE OF AMBIENT WORKING TEMP. SHALL BE -29 TO +60 C UNLESS SPECIFIED IN DATA SHEET. 4. ODORANT THE ODORANT TO BE USED WILL BE MERCAPTAN MAKING A CONCENTRATION OF 10 TO 25 MG. PER STANDARD CUBIC METER WHEN INJECTED TO GAS FLOW. THE COMPOSITION OF MERCAPTAN IS AS UNDER : - ISOPROPYLE MERCAPTAN 80 % APPOX. - N PROPYLE MERCAPTAN 10 % MAX. - TERITIARY BUTYL MERCAPTAN 10 % APPROX. 5. INSPECTION 5.1 IN ADDITION TO ALL MANDATORY CODED PROVISIONS, ALL MATERIALS AND FABRICATION SHALL BE ACCORDING TO INSPECTION TERMS PROVIDED BY PURCHASER IF NECESSARY. 5.2 PRIOR TO FINAL INSPECTION ALL SLAG, LOOSE SCALE, DIRT, GRIT, WELD SPATTER, PRINT, OIL AND OTHER FOREIGN MATTER SHALL BE THOROUGHLY REMOVED SO THAT INSPECTION MAY BE PERFECTLY CARRIED OUT. 5.3 THE SUPPLIER SHALL NOTIFY THE PURCHASER OF READINESS FOR INSPECTION TESTS REQUIRED BY THE SPECIFICATION AND DESIGN CODES REASONABLY PRIOR TO INSPECTION TEST VISITS. 5

5.4 WHERE THE PURCHASER DESIRES TO VISIT THE WORKS TO INSPECT THE WORK OR WITNESS TESTS, ADEQUATE NOTICE TIME IS GIVEN TO THE SUPPLIER. 5.5 THE SUPPLIER SHALL ALLOW FREE ACCESS TO THE PURCHASER TO ALL PARTS OF THEIR OWN, OR THEIR SUBCONTRACTOR S WORK FOR THE PURPOSE OF CARRYING OUT INSPECTION OR TEST WITNESS. 6. TESTING 6.1 ALL TEST CERTIFICATES MUST BEAR THE PURCHASER S NAME AND ORDER NUMBER WHETHER THEY EMANATE DIRECTLY FROM THE MAIN SUPPLIER OR A SUBCONTRACTOR. 6.2 TEST CERTIFICATE MUST BE APPROVED BY THE PURCHASER BEFORE DESPATCH INSTRUCTION IS GIVEN. 6.3 INJECTION TYPE ODORIZERS SHALL BE TESTED AS FOLLOWS : 6.3.1 VISUAL INSPECTION. VISUAL INSPECTION SHALL INCLUDE, BUT NOT LIMITED TO : 1st. 2nd. 3rd. WORKMANSHIP PAINTING ASSEMBLY AND FABRICATION 6.3.2 TEST CERTIFICATES : 1st. EXPLOSION PROOF CERTIFICATE FOR PUMP, CONTROL BOX, SWITCHES AND OTHER ELECTRICAL PARTS. 2nd. 3rd. CERTIFICATE FOR CONTROL COMPONENTS CERTIFICATE FOR SAFETY RELIEF VALVE 6.3.3 PERFORMANCE AND FUNCTIONAL TEST A. PERFORMANCE AND FUNCTIONAL TEST SHALL BE CARRIED OUT FOR ENTIRE REQUIRED CAPACITY RANGE AND SPECIFIED PRESSURE. THIS TEST SHALL BE WITNESSED BY N.I.G.C. REPRESENTATIVE AND TEST CERTIFICATE SHALL BE APPROVED BY N.I.G.C. 6

2nd. 3rd. SAFETY RELIEF VALVE TEST FITLER PERFORMANCE TEST 7 MARKING 7.1 EACH ODORIZER SHALL BE IDENTIFIED BY PERMANENTLY ATTACHED CORROSION RESISTANT NAMEPLATE. NAMEPLATE SHALL BE LOCATED ON THE CONTROL CABINET SO THAT IT IS EASILY VISIBLE AFTER INSTALLATION. THE PUMP SHALL BEAR A NAMPLATE TO MANUFACTURERS STANDARDS. 7.2 NAME PLATE SHALL BEAR THE FOLLOWING INFORMATION : - MANUFACTURER S NAME. - YEAR OF MANUFACTURING - SERIAL NUMBER - PUMP TYPE AND MODEL NO. - MAXIMUM CAPACITY OF PUMP ( L/H ) - MAX. PUMP SWEEP VOLUME PER STROKE ( CM3 ) - PUMP SPEED ( NUMBER OF MAX.STROKE / H ) - PUMP MAX. INJECTION PRESSURE ( BAR ) - POWER SUPPLY VOLTAGE AND FREQUENCY - GAS FLOW RATE ( SCM/H ) - ACTUAL MAX. OPERATING PRESSURE - NIGC PURCHASE ORDER NO. AND ITEM NO. 7.3 FLOW DIAGRAM AND OPERATING INSTRUCTION SHALL BE INDELIBLY PRINTED ON A PERMANENT METAL PLATE AND FITTED ONTO THE CONTROL BOX TO THE PURCHASER S STANDARD / SELECTION. 8 SHIPMENT 8.1 ALL FLANGED OPENINGS SHALL BE PROPERLY PROTECTED BY SUITABLE CAPS. TAPPED OPENINGS SHALL BE PROTECTED WITH THREADED STEEL PLUGS SCREWED IN. 8.2 RELEASE NOTES WILL BE ISSUED BY THE PURCHASER FOR THE ODORIZER AFTER FINAL INSPECTION AND TESTING AT THE WORKS AND ODORIZERS SHALL NOT BE DESPATCHED UNTIL SUCH RELEASE NOTES HAVE BEEN ISSUED. 7

8.3 PRIOR TO SHIPMENT, THE ODORIZER SHALL BE THOROUGHLY CLEANED AND ALL WATER, DIRT, SAND, WELD METAL SCALE AND OTHER SUNDRY MATTERS SHALL BE REMOVED. 8.4 ALL TESTING LIQUIDS SHALL BE REMOVED AND UNITS BE DRIED BEFORE PACKING. 9 GUARANTEE 9.1 MANUFACTURER SHALL GUARANTEE THE COMPLIANCE OF MATERIAL AND PERFORMANCE OF THE SUPPLIED EQUIPMENTS WITH THIS SPECIFICATION. 9.2 THE PERIOD OF GUARANTEE SHALL BE ONE YEAR AFTER EQUIPMENT GOES ON STREAM OR EIGHTEEN MONTHS FROM DATE OF SHIPMENT, WHICHEVER OCCURS FIRST. 9.3 SUPPLIER SHALL AGREE TO REPAIR OR REPLACE ANY UNIT, EQUIPMENT OR PART WHICH PROVES TO BE DEFECTIVE DURING THE ABOVE MENTIONED PERIOD. 10. PACKING FOR EACH ODORIZER, PACKING SHALL BE IN ACCORDANCE WITH N.I.G.C PROTECTION, PACKING, MARKING AND DISPATCHING INSTRUCTIONS. 11. DRAWINGS & DATA FULL SETS OF DRAWINGS AND DATA SHEETS SHALL BE FURNISHED TO THE PURCHASER AT QUOTATION AND ORDER ACKNOWLEDGEMENT STAGES AS FOLLOWS : 1st. AT QUOTATION STAGE ( 3 COPIES ) 2nd. AT ORDER ACKNOWLEDGEMENT STAGE ( 5 COPIES ) 11.1 GENERAL ARRANGEMENT AND DETAIL DRAWINGS SHOWING OUTLINE DIMENSIONS, CALCULATION AND TECHNICAL DATA AND WEIGHTS. 11.2 COMPLETEE SPECIFICATION, ORIGINAL CATALOGUES AND FUNCTIONAL DESCRIPTION OF ALL COMPONENTS, INSTRUMENTS, VALVES AND PARTS LIST. 11.3 RECOMMENDED SPARE PARTS LIST WITH UNIT PRICES FOR COMMISSIONING AND TWO YEARS OPERATION. 8

11.4 COMPLETE INSTRUCTION MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE OF ODORIZER. 9

APPENDIX B ODORANT LOADER SPECIFICATION 1. OPERATING METHOD AND DESCRIPTION : ODORIZING AGENT USED FOR ODORIZATION ( MERCAPTAN ) IS USUALLY SUPPLIED IN 200 LT STANDARD STEEL BARRELS. DUE TO THE FACT THAT THE ODORIZING AGENT HAS A CHARACTERISTIC PENETRANT OFFENSIVE, SMELL IT IS NECESSARY TO FILL THE LIQUID INTO THE ODORANT TANK BY SPECIAL DEVICE TO PREVENT POLLUTION. EACH ODORANT LOADER SHOULD BE CONSISTING OF : - A PRESSURE SUPPLY UNIT - A SEPARATE LANCE THROUGH WHICH THE ODORANT IS DISCHARGED. 1.1 PRESSURE SUPPLY UNIT THE PRESSURE SUPPLY UNIT IS NECESSARY TO LOAD THE BARREL WITH A SLIGHT OVERPRESSURE. THIS UNIT IS CONSISTING OF : - A QUICK RELEASE SELF SEALING COUPLING ¾ NPT ( 6 ). - A FILTER ( 5 ). - A PRESSURE CONTROLLER OF OUTLET 5 PSIG ( 4 ). - A ¾ BACK PRESSURE VALVE ( 3 ). - FULL CAPACITY SAFETY RELIEF VALVE ¾ ( 2 ). - MANUAL SHUT OFF VALVE ¾ ( 1 ). - PRESSURE GAUGE ( 9 ). - FLEXIBLE HOSE ST.STL. PTFE LINED ¾ ( 10 ). THE QUICK COUPLING CAN BE CONNECTED TO A SUITABLE SOURCE OF PRESSURIZED GAS. THE GAS IS PASSING THE PRESSURE CONTROLLER, WHERE IT IS REDUCED TO A PRESSURE OF MAX. 250 MBAR. THE OPENING PRESSURE OF THE SAFETY RELIEF VALVE IS 250 MBAR AND PROTCTS THE BARREL AGAINST NON PERMITTED OVERPRESSURE. THE GAS PRESSURE CAN BE INTERRUPTED BY THE BUILT IN SHUT OFF VALVE. - SEALING PARTS SHALL BE RESISTANT AGAINST MERCAPTAN ADVERSE EFFECTS. 1.2 LANCE 10

THE LANCE, WHICH MUST BE SEPARATELY INSTALLED IN THE 200 LT STEEL BARREL SHOULD BE CONSISTING OF : - A PIPE WITH 2 INCH THREAD CONNECTION ( 11 ). - A ¾ SHUT OFF VALVE ( 8 ). - A ¾ BUILT IN BACK PRESSURE VALVE ( 7 ). - A ¾ QUICK COUPLING WITH A 5 METER PTFE FLEXIBLE TUBE ST.STL. WIRE PROTECTED. THE BUILT IN BACK PRESSURE VALVE ( 7 ) PROTECTS THE BARREL AGAINST WRONG OPERATING PROCEDURE. - SEALING PARTS SHALL BE RESISTANT AGAINST MERCAPTAN ADVERSE EFFECTS. 11

APPENDIX C DATA SHEET 1. MAX. & MIN. LINE PRESSURE.. KG/CM2... PSIA. 2. MAX. & MIN. GAS TEMP. DEG.C. 3. MAX. GAS FLOW.... SCMH 4. DIAMETER OF GAS LINE. INCH 5. TYPE OF THE GAS METER : ( ) TURBINE ( ) ORIFICE 6. ODORANT : MERCAPTAN 7. ODORANT CONCENTRATION. 10-25MG. PER SCM 8. INSTALLATION : OUTDOOR 9. INPUT SIGNAL ( DIGITAL :.. ), ( ANALOG : ) 10. RELIEF VALVE SET PRESSURE 2.4 KG/CM2 = 35 PSIA 11. MAX. DISTANCE FROM GAS METER TO CONTROL CABINET. METERS 12. MAX. AMBIENT TEMP.... DEG.C. 13. MIN. AMBIENT TEMP. DEG.C. 14. MAX. SUN TEMP.. DEG.C. 15. MAX. RELATIVE HUMIDITY. % 16. MAX. WIND VELOCITY.. KM/H 17. TOTAL ANNUAL RAINFALL.. MM 18. INDENT NO..ITEM NO.. 12