MODEL 200 MULTI-JET FLOW METER

Similar documents
MODEL 200 MULTI-JET FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER

Model 1100 Turbine Flow Meter

MODEL 1100 TURBINE FLOW METER

Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual

Model 1100 Turbine Flow Meter

Model 1100 Turbine Flow Meter Repair Kits

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

MODEL B1750 POSITIVE DISPLACEMENT FLOW METER

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

CAUTION CAUTION IN-LINE LIQUID FLOW METER INSTALLATION & MAINTENANCE INSTRUCTIONS FORM # HLIT205-2G

Turbine Flow Meter Series Turbine Meter USER MANUAL

EZ-IN Series Turbine Flowmeter

JET METER INSTRUCTIONS

Liquid Turbine Flowmeter

INSTALLATION AND OPERATING MANUAL

Flow-Alert Flow Switch Installation & Maintenance Instructions

Installation, Operation & Maintenance Manual

FIXED DEPTH INSERTION METER INSTRUCTIONS

Colt Series C400, C500

MULTIPOSITION AIR CYLINDER

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

In-line Pneumatic Flow Meter Installation & Maintenance Instructions

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

ProFlo FatBoy

THD-2-FM CONTROLAIR VALVE

PowerFLO 5800/5900 Series

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Rotary Flow Meter SERVICE MANUAL*

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Centrifugal Pump Warranty Guide

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

TYPE S RELAY VALVE (Volume booster) Service Manual

Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Models P420A-3100 & P420A-5100

INSTALLATION AND OPERATING MANUAL

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Turbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015)

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Model LP301A Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Type Flexair Pneumatic Pressure Control Valves

Model LP200, LP250 & LP250W-MT

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

PPM EO-100 TM. Operation Manual

Analog Hydraulic Testers

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Manual Concentrate Management System

Positive Displacement Flowmeters GM007 series instruction manual

AUTOMATIC SUBMERSIBLE UTILITY PUMP

11202 INSTALLATION INSTRUCTIONS

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

Owner s Manual. Soda Ash ph Neutralizer System

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

MODEL 5120 Tire Repair Station

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Wastewater Air Release Valve Models 48A, 49A

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

GENERAL SPECIFICATIONS FOR:

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

PRO ES Test Fixture, High Voltage Test Probe, & KV Meter

TITAN FLOW CONTROL, INC.

Models LP122A/LP123/LP255

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PNEUMATIC PIPING DEVICES Service Information

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Operator s Safety and Service Manual

Series 007. Double Check Valve Assembly. Installation Service Repair Kits Maintenance. Sizes: 1 2" 3" Watts 3 4" 007M3QT RP/IS-007

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

POSITIVE DISPLACEMENT FLOWMETERS

Positive Displacement Flowmeters GM020 series instruction manual

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

General Design Features

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Industrial Turbo Meters, Sizes 2" through 6"

Installation, Maintenance, & Repair Series 919 and LF919

Turbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016)

DAKOTA INSTRUMENTS OPERATING MANUAL ACR ACRYLIC FLOW METERS

Model LP122A Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Owner s Manual Nitrate Series Salt Based Filter System

TITAN FLOW CONTROL, INC.

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION AND OPERATING

Pressurized Pond Filter Up to 850 gallons

Transcription:

MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155 www.blancett.com

TABLE OF CONTENTS Introduction...3 Operating Principle...3 Specifications...4 Operating Limitations...5 Installation Instructions...5 Operational Start-up...6 Installation Drawings...7 Troubleshooting...8 Repair Kit Information...9 Dimensions...10 Statement of Warranty...11 NOTE: Blancett reserves the right to make any changes or improvements to the product described in this manual at any time without notice. 2 Form No. B190-001 04/10

INTRODUCTION The Blancett Model 200 is a rugged low-priced flow meter specifically designed for low flow capacity waterflood projects. The multijet impeller provides accurate long-term flow measurement and accumulative volumetric totals of high pressure floodwater. With a minimal number of moving parts, the Model 200 provides dependable operation with low maintenance. OPERATING PRINCIPLE The Model 200 features a radial vaned impeller, mounted on a vertical spindle within a cylindrical measuring chamber. Fluid entering the meter passes through the lower measuring chamber through several tangential orifices located around the cylinder. The flowing water causes the impeller blades to rotate at a speed directly proportional to flow rate. The rotating impeller is magnetically coupled to a mechanical register, and each impeller rotation is mechanically tabulated and displayed. Figure 1 Operating Principle Form No. B190-001 04/10 3

SPECIFICATIONS FLOW RANGE: 5 to 685 BPD (0.15 to 20 GPM) Continuous flow not to exceed 342 BPD (10 GPM) MATERIALS of CONSTRUCTION: Body: Stainless Steel Rotary Vane Impeller: Fiber-glass filled Ryton Gaskets: Top seal cup & bottom measuring element Neoprene or optional Viton Connections: 1" NPT female OPERATING LIMITATIONS: Temperature: +200 F (+93 C) maximum The meter should not be subjected to temperatures below the freezing point of the metered liquid. Pressure: 1,000 psi maximum Accuracy: ±1.0% of reading Repeatability: ±0.1% Corrosion: All Blancett Model 200 meters are constructed of stainless steel and tungsten carbide. The operator must ensure that the operating fluid is compatible with these materials. Incompatible fluids can cause deterioration of internal components and cause a reduction in meter accuracy. Pulsation and Vibration: Severe pulsation and mechanical vibration will affect accuracy and shorten the life of the meter. Filtration: A strainer capable of removing 0.020 in (0.50 mm) particles, should be installed upstream of the meter. 4 Form No. B190-001 04/10

INSTALLATION INSTRUCTIONS Prior to installation, the flow meter should be checked internally for foreign material and to ensure the impeller spins freely. Fluid lines should also be checked and cleared of all debris. The flow meter must be installed with the flow arrow, cast on the exterior of the meter body, pointing in the direction of fluid flow. The preferred mounting orientation is to have the meter installed in horizontal piping with the register facing upward. The liquid being measured should be free of any large particles that may obstruct rotation of the impeller. If particles are present, a mesh strainer should be installed upstream before operation of the flow meter. Some sand and small particles are permissible. A 30 30 (0.020 opening) mesh strainer is recommended. The preferred plumbing setup is one containing a by-pass line that allows meter inspection and repair without interrupting flow. If a bypass line is not utilized, it is important that all control valves be located downstream of the flow meter. (See Figures 3 and 4 on page 6.) CAUTION: Open valves slowly to ensure that entrapped air does not cause meter to rotate at an excessive speed. Damage can be caused by striking an empy meter with a high velocity flow of gas or liquid. This is true with any restriction in the flow line that may cause the liquid to flash. If necessary, air eliminators should be installed to ensure that the meter is not incorrectly measuring entrained air or gas. Do not locate the flow meter close to a pump, because sever pulsation may negatively effect accuracy and flow meter life. Form No. B190-001 04/10 5

Figure 3 Meter installation utilizing a by-pass line Figure 4 Meter installation without utilizing a by-pass line 6 Form No. B190-001 04/10

OPERATIONAL START-UP The following steps should be followed when installing and starting the meter. WARNING: Make sure that fluid flow has been shut off and pressure in the line released before attempting to install the meter in an existing system. 1. After meter installation, close the isolation valves and open the bypass valve. Flow liquid through the by-pass valve for sufficient time to eliminate any air or gas in the flow line. CAUTION: Damage can be caused by striking an empty meter with a high velocity flow stream. 2. Open upstream isolating valve slowly to eliminate hydraulic shock while charging the meter with the liquid. Open the valve to full open. 3. Open downstream isolating valve to permit meter to operate. 4. Close the by-pass valve to a full closed position. 5. Adjust the downstream valve to provide the required flow rate through the meter. NOTE: The downstream valve may be used as a control valve. Form No. B190-001 04/10 7

TROUBLESHOOTING GUIDE Trouble Possible Cause Remedy No indication on register Low flow indication High flow indication Debris in measuring chamber Broken gears or shaft in register assembly Flow rate is too low By-pass valves are leaking Gas in liquid Debris covering a portion of the meter inlet Disassemble meter, clean out debris and inspect for worn parts Replace register Increase flow above 0.25 GPM Close valves completely, repair or replace Install gas eliminator ahead of meter Remove meter from line and clean out debris 8 Form No. B190-001 04/10

Part Number REPAIR KIT INFORMATION Repair Kit Description Gasket Material B250-250 Complete Repair Kit; 42 Gallon Barrels Buna B250-252 Complete Repair Kit; 42 Gallon Barrels Viton B250-254 Complete Repair Kit; US Gallons Buna B250-256 Complete Repair Kit; US Gallons Viton B250-258 Complete Repair Kit; Cubic Meters Buna B250-260 Complete Repair Kit; Cubic Meters Viton B250-251 Repair Kit less Register; 42 Gallon Barrels Buna B250-253 Repair Kit less Register; 42 Gallon Barrels Viton B250-255 Repair Kit less Register; US Gallons Buna B250-257 Repair Kit less Register; US Gallons Viton B250-259 Repair Kit less Register; Cubic Meters Buna B250-261 Repair Kit less Register; Cubic Meters Viton Form No. B190-001 04/10 9

7.50 (190.5) 4.70 (119.4) 4.00 (101.6) Figure 5 Dimensions 10 Form No. B190-001 04/10

STATEMENT OF WARRANTY Blancett Flow Meters, Division of Racine Federated Inc. warrants to the end purchaser, for a period of one year from the date of shipment from the factory, that all flow meters manufactured by it are free from defects in materials and workmanship. This warranty does not cover products that have been damaged due to defects caused by misapplication, abuse, lack of maintenance, modified or improper installation. Blancett s obligation under this warranty is limited to the repair or replacement of a defective product, at no charge to the end purchaser, if the product is inspected by Blancett and found to be defective. Repair or replacement is at Blancett s discretion. A return goods authorization (RGA) number must be obtained from Blancett before any product may be returned for warranty repair or replacement. The product must be thoroughly cleaned and any process chemicals removed before it will be accepted for return. The purchaser must determine the applicability of the product for its desired use and assumes all risks in connection therewith. Blancett assumes no responsibility or liability for any omissions or errors in connection with the use of its products. Blancett will under no circumstances be liable for any incidental, consequential, contingent or special damages or loss to any person or property arising out of the failure of any product, component or accessory. All expressed or implied warranties, including the implied warranty of merchantability and the implied warranty of fitness for a particular purpose or application are expressly disclaimed and shall not apply to any products sold or services rendered by Blancett. The above warranty supersedes and is in lieu of all other warranties, either expressed or implied and all other obligations or liabilities. No agent or representative has any authority to alter the terms of this warranty in any way. Form No. B190-001 04/10 11

8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155 www.blancett.com info@blancett.com BLANCETT is a registered trademark of Racine Federated Inc. RYTON is a registered trademark of Chevron Phillips Chemical Company LP. VITON is a registered trademark of DuPont Dow Elastomers. UL is a registered trademark of Underwriters Laboratories. 2010 Racine Federated Inc. Printed in USA Form No. B190-001 04/10