INSTLLTION INSTRUCTIONS RED "SFETY MNUL" ND "USER MNUL" BEFORE STRTING THE UPS INSTLLTION LYOUT INFORMTION FNS IR FLOW IR FLOW! HOT FNS REMOVIBILE COVER FRONT VIEW SIDE VIEW RER VIEW PERSPECTIVE VIEW PERSPECTIVE VIEW WITH OPEN DOOR NOTE: 1000 MINIMUM FRONT DISTNCE TO THE WLL (RECOMMENDED 10) BCK CBLE ENTRY Power Type MIN INFORMTION kv / MST 1 MST 1 / 1 / Operating temperature C 0-40 Max relative humidity in operation % 90 % (without condensation) WHEEL CENTER SWIN SWBY SWMB SWOUT Max installation height Power Loss@load 100% (1) Power Loss@load % Net Dimension W x D x H Shipping Dimension W x D x H kcal / h B.T.U. / h kcal / h B.T.U. / h 1000m at nominal power (-1% power for every 100m above 1000m) max 4000m 6,9 5933 23544 3,6 95 12284 9,3 7997 31733 4,4 3783 113 840 x 10 x 1900 1010 x 1145 x 2085 Net Weight Kg 4 4 Shipping Weight Kg 490 0 ir Flow 3 m / h FRONT BOTTOM VIEW Current dispersed to ground (2) m < 0 Degree of protection IP 20 (1) 3.97 B.T.U. / h = 1 kcal / h (2) The load leakage current is added to the one of the UPS on the ground protection conductor
INPUT LINE 3PH + N + PE INPUT C LINE - SINGLE LINE 1 Max admitted neutral current 400 400 316 320 POWER INFORMTION 385 400 WRNING -THE INPUT OUTPUT ND PROTECTIVE ERTHING CONDUCTORS MUST BE SIZED FOLLOWING RTED VOLTGE ND CURRENT, SHOWN IN THE TBLES BELOW, ND CCORDING TO DOMESTIC REGULTIONS ND CURRENT STNDRDS -THE PROTECTIVE ERTHING CONDUCTOR (PE) MUST BE CONNECTED FIRST BEFORE TO PROCEDE CONNECTING INPUT / OUTPUT CBLES Terminal (L1, L2, L3) or (L1Byp, L2Byp, L3Byp) INPUT C LINE - DUL SEPRTED LINE (Remove the bars connecting input mains - bypass line) INPUT LINE 3PH + N + PE 1 316 385 Max admitted neutral current 400 400 320 400 Terminal (L1, L2, L3) INPUT BYPSS LINE 3PH + N + PE 1 2 326 Max admitted neutral current 400 400 Terminal (L1Byp, L2Byp, L3Byp) (2) (1) 320 400 (1) The neutral terminal is the same for input mains and bypass line (2) The is the same for all connections BTTERY INPUT (+), (-), N + PE bsolutely max size of battery string protection device Terminal (+), (-) BTTERY DC INPUT (The PE conductor from battery cabinet must be connected at the UPS earthing terminal only) Rated current @ nominal battery voltage 3 4 @ end of discharge voltage 455 565 Max size of battery string protection device: gl / gg fuse ar fuse (2) OUTPUT LINE 3PH + N + PE Rated current Output protection (recoended values for selectivity) Normal fuses (gl - gg) Thermal magnetic switches (C curve) Terminal (L1, L2, L3) 1 OUTPUT C LINE 1 2 x h (battery capacity) 2,5 x h (battery capacity) 55 400 0 237 296 In / 4 In / 4
REMOVE JUMPERS FOR DUL INPUT POWER DETILS NUT M10 SPRING WSHER diam. 10 PLIN WSHER diam. 10 N L1 L1B L2 L2B L3 L3B PLIN WSHER diam. 10 SCREW M10 INPUT LINE (N / L1 / L1B / L2 / L2B / L3 / L3B) see detail DETIL INPUT - OUTPUT - BTTERY CBLES OUTPUT LINE (L3 / L2 / L1 / N) see detail L3 L2 L1 N SCREW M8 SPRING WSHER diam. 8 PLIN WSHER diam. 8 PROTECTIVE ERTH (PE) see detail «B» - N + BTTERY LINE (- / N / +) see detail DETIL «B» PROTECTIVE ERTH (PE) CBLES
B D D E E 465.5 570 413.5 (PE) 477.5 SECTION - B SECTION B-B 89 89 SECTION D-D 77.5 77.5 122.5 252.5 252.5 122.5 55 15 15 15 15 27.5 27.5 SECTION E-E (PE) NEUTRL ( N ) INPUT / OUTPUT BTTERY ( + / - ) BTTERY ( N ) 46 46 347.5 48 347.5
SIGNL S and COMMUNICTION DETILS FNS Slot for parallel card ( OPTIONL ) RS232 Port USB Port S400 Port R.E.P.O. Counication slot 2 Counication slot 1 Cold start Schuko socket fuse Schuko socket FNS ZONE INPUT FUSES FNS SERVICE BYPSS RESERVED EXTERNL SYNC EXT. BTTERY TEMP PROBE SWITCH OUT UX CONTCT UX RELY SLOT BRKE ROD FRONT VIEW RER VIEW UXILIRY SIGNL S