ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Similar documents
ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

Hazardous Factory Sealed Control Devices

Control Stations Hazardous and Non-Hazardous

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Motor Starters Hazardous and Non-Hazardous

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Condulet Conduit Bodies and Outlet Boxes Hazardous

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

GHG43 Series Control Stations

Circuit Breakers Hazardous

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

EBMC Combination Line Starters and Enclosures

Division 2 Contender Series Factory Sealed Control Stations

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Covers for Cast Iron or Aluminum Device Boxes

Spring-loaded cover seats against neoprene gasket.

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

FACTORY SEALED CONTROLS - INTRODUCTION

Enclosures. Section E

Junction Boxes Hazardous and Non-Hazardous

Push Button. Rocker Arm

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

STAINLESS STEEL PANEL MOUNT

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

FACTORY SEALED CONTROLS - INTRODUCTION

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Plugs and Receptacles: Hazardous Location

Condulet Cast Device Boxes and Covers Application and Selection

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

EPOXY POWDER COATED COPPER FREE ALUMINUM

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

N2MV Series W Non-metallic

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

Industrial Control & Circuit Breakers

Hazardous Duty Applications

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

UniCode Series Factory Sealed Control Stations and Pilot Lights

W-Series Junction Boxes

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Comfort. Description. Applications

4 Square Partition Square Cut Tile Wall 2 Gang Cover 2 1/8 Deep 1/2 to 1 RSD

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

the Interactive Catalog

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

254 Series Convector. Standard Construction Features

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

NMC Combination Line Starters and Enclosures

Convector. Standard Construction Features

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

IEC 309 Plugs, Connectors, Receptacles, and Inlets

PEERLESS BLOWERS DIRECT DRIVE BLOWERS

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

YFC. Limit switch. Ex d. 24 operating head types

ACE Variable Frequency Drive System

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Transcription:

EDS2274 Pos D.E. Selector Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type SINGLE GANG Contact Configuration 4NO-4NC Number of Circuits 4 Number of Positions Operation Type MAINTAINED Operator Type LEVER Voltage Rating 600 VAC Material, Color, and Finish Enclosure Material Dimensions and Weight Hub Size Descriptions Commodity Description Long Description Product Type EDS2274 Cooper Crouse-Hinds Selector Switch, Dead End; Dust Ignition Proof, Explosion Proof, Rain Tight; 600 Vac; Operation Type Maintained; Contact Configuration 4NO-4NC; 4 Circuit(S); Position(S); Lever Operator; Single Gang Box; /4 Inch Hub Size 8.6 (lbs/each) Selector Switch Complete Assem ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY /4 INCH SELECTOR SWITCH COMPLETE ASSEMBLIES SELECTOR SWITCH, DEAD END; DUST IGNITION PROOF, EXPLOSION PROOF, RAIN TIGHT; 600 VAC; OPERATION TYPE MAINTAINED; CONTACT CONFIGURATION 4NO-4NC; 4 CIRCUIT(S); POSITION(S); LEVER OPERATOR; SINGLE GANG BOX; /4 INCH HUB SIZE Selector Switch

Manufacturer Information Brand CONTROL & APPARATUS GTIN 00782274764696 Manufacturers Part Number EDS2274 Model EDS UPC 782274764696 Taxonomies, Classifications, and Categories Type DEAD END Availability Manufacturer Status Packaging Carton Weight Per each 8.55 Non-Stock Uses, Certifications, and Standards Enclosure CLASS I DIV AND 2 GROUP B C D, CLASS II DIV GROUP E F G, CLASS II DIV 2 GROUP F G, CLASS III, NEMA /7B/7C/7D/9E/9F/9G

EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: To prevent arcing of enclosed device from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust In non-hazardous areas where sturdy, durable enclosures are required In conjunction with magnetic starters or contactors for remote control of motors Manual motor starting switch enclosures are used: For manual starting of small AC or DC motors To provide manual starting and stopping and, in the case of units with heaters, motor running protection Features: Factory sealed devices have many distinct advantages: Reduce installation problems Eliminate external seals Lower installation costs Improve safety Are used with general purpose snap and pushbutton type switches Standard neoprene covers for front operated pushbuttons. Prevents accumulation of dirt and entrance of water around operating shafts Mounting lugs and taper tapped hubs with integral bushings Large machine screws for fastening covers to bodies Lockout provisions on front operated pushbutton (marked "STOP" and "OFF") and selector switch covers Lockout hole for padlock having /4" hasp is provided when used with covers for front lever and side rocker type operation Close tolerances in machining of wide, mating flanges and journalled shafts and bearings for front button operation, produces flametightness of enclosure joints On enclosures with front lever and side rocker type operating handles, threaded type shafts and bushings are used to ensure flametightness Dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs /2" to " sizes When STOP is indicated, button is automatically red. When START is indicated, button is automatically green. Otherwise, black buttons are standard. Certifications and Compliances: NEC/CEC: Class I, Division & 2, Groups B*, C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III NEMA/EEMAC:, 7B*CD, 9EFG UL Standard: 20 CSA Standard: C22.2 No. 0 Standard Materials: Bodies Feraloy iron alloy; copper-free aluminum Front operated pushbutton and pilot light covers Feraloy iron alloy Side operated type pushbutton covers copper-free aluminum Shafts stainless steel Shaft bushings stainless steel Rocker handle and pushbutton guards type 6 / 6 nylon Sealing enclosures copper-free aluminum Standard Finishes: Feraloy iron alloy electrogalvanized and aluminum acrylic paint Copper-free aluminum natural Type 6 / 6 nylon black Stainless steel natural Options: The following special options are available from the factory by adding suffix to Cat. #: Description Suffix Emergency "Stop" button (momentary) front operated red mushroom button... S Lockout provision on front operated pushbutton cover (standard on buttons marked "OFF" and "STOP")... S5 For 24 VDC operation on pilot lights... S00 Three-position selector switches with modified operation: Momentary contact clockwise operation, spring return to center, maintained contact counter-clockwise operation... S64 Momentary contact counter-clockwise operation, spring return to center, maintained contact clockwise operation... S65 Bodies and covers (single and two gang units) copper-free aluminum... SA Where indicated in the catalog listings, EDS units suitable for Class I, Division, Group B usage can be supplied, add suffix -GB, EFS units are suitable for Class I, Division, Group B as standard... GB Maintained contact mushroom head with lockout and guard. May not be combined with a pilot light if a transformer is required... S769 Spring return to center from right and left (For DEV4 or DEV44 only)... S842 EDS bodies and factory sealed cover and device sub-assemblies are available for field assembly (see page 55). *See suffix GB in Options section www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 59

EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Methods of Factory Sealing EFS/EDS Series EDS Series Factory sealed EDS and EFS pilot light, pushbutton and selector switch control stations do not need external sealing. Device contacts are factory sealed in explosionproof ESWP contact blocks. Small, compact enclosures have accurately ground wide flanges on both the body and cover for a flame-tight joint. Dimensions (Inches) Bodies EDS factory sealed snap switches or manual motor starting switches do not need external sealing. The switches are enclosed in a unique sealing well with double flanges which mate with the cover and the body. Small, compact enclosures have accurately ground wide flanges on body, cover and sealing well for flame-tight joints. Wiring pigtails are factory sealed from under the sealing well. Reliable pouring of seals at the factory ensures safe sealing. Covers Hub Size /2 Dim. "h" /4 Dim. "i" /6 /4 7 /8 /6 5 /6 Side View General use snap switch front operated and manual motor starting switch Pushbutton switch rocker type side operated Front View - Single gang Front View - Two gang Pushbutton switch front operated Selector switch *See suffix GB in Options section. Dimensions are approximate, not for construction purposes. Surface covers have same length and width as bodies. 520 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

EDS / EFS Series Control Stations Fully Assembled EFS Pilot Lights Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: EFS pilot lights are used: In areas which are hazardous due to the presence of flammable vapors, gases or highly combustible dusts For installation at petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards exist To visually indicate at a remote location that the desired function is being performed Features: Small, compact enclosures with accurately ground flange on both body and cover for flame-tight joint Pilot lights are factory sealed. Conventional external seals are not required Dead end (EFS) or through feed (EFSC) hubs /2" to " sizes Certifications and Compliances: NEC/CEC: Class I, Groups B*, C, D Class II, Groups E, F, G Class III NEMA/EEMAC:, 7B*CD, 9EFG UL Standard: 20 CSA Standard: C22.2 Options: The following special options are available from factory by adding suffix to Cat. #: Description Suffix Pilot lights for circuit voltages up to 600 volts maximum (standard voltage range 0 25) See Listings LED pilot lights in place of standard incandescent pilot lamps Bodies and covers copper-free aluminum LED 24 VDC operation on pilot lights S00 SA Standard Materials: Bodies Feraloy iron alloy (U.S.) and copper-free aluminum (Canada) Pilot light covers Feraloy iron alloy Operating shafts stainless steel Standard Finishes: Feraloy iron alloy electrogalvanized with aluminum acrylic paint Copper-free aluminum natural Stainless steel natural Electrical Rating Range: Pilot lights 0 to 600VAC * External conduit seal required for inch hub size in Division, Group B within 5 feet (.5 meters) of enclosure. 524 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

EDS / EFS Series Control Stations Fully Assembled EDS Factory Sealed Selector Switches Maintained Contact, 600VAC Heavy Duty Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify indicating plate markings. See table below listings. Dimensions see page 520 EDS27 Ordering Information - Single Gang Style Position Position 2 Position Replacement Contact Blocks Enclosure with Switch Hub Size Dead End Cat. # Through Feed Cat. # Two-Position, Two-Circuit Two-Position, Four-Circuit Three-Position, Two-Circuit Three-Position, Four-Circuit ED ED2 ED ED2 ED2 /2 EDS27 ➀ EDSC27 ➀ /4 EDS227 ➀ EDSC227 ➀ EDS27 ➀ EDSC27 ➀ /2 EDS272 ➀ EDSC272 ➀ /4 EDS2272 ➀ EDSC2272 ➀ EDS272 ➀ EDSC272 ➀ /2 EDS27 ➀ EDSC27 ➀ /4 EDS227 ➀ EDSC227 ➀ EDS27 ➀ EDSC27 ➀ /2 EDS274 ➀ EDSC274 ➀ /4 EDS2274 ➀ EDSC2274 ➀ EDS274 ➀ EDSC274 ➀ /2 EDS275 ➀ EDSC275 ➀ /4 EDS2275 ➀ EDSC2275 ➀ EDS275 ➀ EDSC275 ➀ ➀ If desired, markings on indicating plates may be added to catalog number. Select from the list of standard markings below: Two-Position RUN, JOG FAST, SLOW IN, OUT HAND, AUTOMATIC OPEN, CLOSE RAISE, LOWER FORWARD, REVERSE UP, DOWN START, STOP ON, OFF Three-Position RUN, OFF, JOG, OFF, 2 HAND, OFF, AUTOMATIC OPEN, OFF, CLOSE FORWARD, OFF, REVERSE UP, OFF, DOWN FAST, OFF, SLOW *For Class I, Group B: Consider using EFS series selector switches, see page 528. All enclosures listed above can be modified for Class I, Group B, Div. usage. Add suffix GB to the Cat. No. Seals must be installed within /2" of each conduit opening in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. For replacement contact blocks, see page 565. Suffixes S64 or S65 may be used on these catalog numbers. see page 59 for explanation of options. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 527