A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

Similar documents
M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

A165E CSM_A165E_DS_E_11_2

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4BS CSM_D4BS_DS_E_8_4

G3PE-Single-phase. Solid State Relays for Heaters

D4GS-N CSM_D4GS-N_DS_E_7_2

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

2NC (slow-action) Direct. Model. opening

Model Number Structure

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

2NC (slow-action) Direct. Model. opening

S8JX-N/S8JX-G Series Replacement Brackets

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

D4BL. Guard Lock Safety-door Switch

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

DIN Track Terminal Blocks with Screw Terminals XW5T

A22LK CSM_A22LK_DS_E_6_2

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Model

DIN Track Terminal Blocks with Screw Terminals XW5T

D4NH CSM_D4NH_DS_E_7_1

DIN Track Terminal Blocks with Screw Terminals

Better Productivity by Standstill and Low-speed Monitoring

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Dimension A. Dimension B

Multiple Limit Switch

CSM_D4N-_R_DS_E_6_1

A L - J R M - 24D - 2

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models

Lighted Pushbutton Switch

Digital display Pressure range ON/OFF output Linear output Model

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Safety Limit Switch

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

A4EG CSM_A4EG_DS_E_6_1

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

Subminiature Basic Switch

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

Lighted PushButton Switch

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Safety Guard Switching Unit G9SX-GS

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

D4BL. Guard Lock Safety-door Switch

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Best-selling Basic Switch Boasting High Precision and Wide Variety

Mechanical Key Switch

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Small Limit Switch D4V

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Small-diameter Proximity Sensor

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

A16/M16. Ordering Information. Pushbutton Switches/Pilot Lights. Complete Assemblies. Mounting Aperture of 16 mm. H Modular construction (Pushbutton +

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Safety Limit Switch

Miniature Limit Switches

We Make It Easy! 3. All of our switches are shipped complete, just as ordered. No incomplete or partial deliveries of subcomponents and accessories

A22TK Key-type Selector Switch with Direct Opening Mechanism

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4NL CSM_D4NL_DS_E_9_2

EStrong-series Emergency Stop

Distinctive Characteristics

Smile 11 RA/-B Smile 12 RF/-G Reset button

1,000 M min. (at 500 VDC)

Model Number Structure

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Bright illumination face and snap-action switching.

Best-selling Basic Switch Boasting High Precision and Wide Variety

Model Number Structure

Safety Interlock Switches

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

A22NK. Key-type Selector Switches

Ordering Information. Text Surface-Mounting Signal Relay G6K

Sense7-series Non-contact coded safety switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

ø8 A8 Series Miniature Control Units

Technical Guide for Basic Switches

Transcription:

Lighted Pushbutton Switch (Square) CSM DS_E_7_ Pushbutton Switch Series with Square 40-mm Body Combines miniature design with distinct but soft sense of operation. Easy panel mounting from the front and simple replacement without tools. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 8. List of Models Lighted Pushbutton Switches Appearance Model Rectangular J Square A Specifications: Refer to page 2. Dimensions: Refer to page 4. Accessories: Refer to pages 0 to.

Model Number Structure Model Number Legend... The model numbers used to order sets are illustrated below. One set comprises the Operation Unit, Lamp, and Socket Unit. For information on combinations, refer to Ordering Information on pages 3 to 4. - 24E R... Single screen () (2) Left Right A 3 S J - 9 0 A 3-24E RW... Vertical 2-split screen Left R (Red) Right W (White) () Shape of Operation Unit (2) Switch Specifications Standard Load (3) Screen Pattern Illumination-only models (4) Lighting Method LED-lighted Models (5) Operation Unit Color For LED J A Shape Symbol Rectangular Square Symbol Operation A Momentary SPDT B Alternate C Momentary DPDT D Alternate Microload Symbol Operation Symbol 3 Screen pattern Single screen Vertical 2-split screen Symbol 05E 2E 24E Rated voltage 5 VDC 2 VDC 24 VDC Lamp-lighted Models Symbol Color R Red Y Yellow G Green W White * Lamp-lighted Models E Momentary SPDT F Alternate G Momentary DPDT H Alternate Standard Load 250 VAC, 2 A 25 VDC, 0.4 A Microload 25 VAC, 0. A 30 VDC, 0. A Minimum applicable load 5 VDC, ma Momentary operation...self-resetting Alternate operation...self-holding (rectangular models only) Models with colored illumination can be ordered individually. Refer to page 5 for details. Colored Illumination Unlit White Lit Color The built-in LED is colored. Symbol Rated voltage 06 6 VAC/VDC 4 4 VAC/VDC 28 28 VAC/VDC Number of Built-in LEDs and Lamps Model Screen pattern LED Single screen 2 J Vertical 2-split screen 2 2 Symbol Color R Red Y Yellow G Green A Blue W White * * The color cap is transparent. A Single screen Type Structure of Split-screen Operation Unit Color cap Legend plate * Dispersion plate Light-separation plate (2-split screen only) Single screen (Rectangular models and square models) Vertical 2-split screen (Rectangular models only) LED/incandescent holder J * Not included for the Square Models (A) with incandescent. 2

Ordering Information Ordering as a Set...The model numbers used to order sets of Units are given in the following tables. One set comprises the Operation Unit, Lamp, and Socket Unit. Standard Loads Rectangular Models Single screen J Single screen Vertical 2-split screen 2 Output SPDT DPDT LED Lighting LED * only. Contact type Standard load (250 VAC, 2 A; 25 VDC 0.4 A) Operation Momentary operation Alternate operation (Self-resetting) (Self-holding) 5 VDC J-90A-05E@ J-90B-05E@ 2 VDC J-90A-2E@ J-90B-2E@ 24 VDC J-90A-24E@ J-90B-24E@ 6 VAC/VDC J-90A-06@ J-90B-06@ 4 VAC/VDC J-90A-4@ J-90B-4@ 28 VAC/VDC J-90A-28@ J-90B-28@ 5 VDC J-90C-05E@ J-90D-05E@ 2 VDC J-90C-2E@ J-90D-2E@ 24 VDC J-90C-24E@ J-90D-24E@ 6 VAC/VDC J-90C-06@ J-90D-06@ 4 VAC/VDC J-90C-4@ J-90D-4@ 28 VAC/VDC J-90C-28@ J-90D-28@ Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) Vertical 2-split screen Output Lighting Contact type Standard load (250 VAC, 2 A; 25 VDC 0.4 A) Operation Momentary operation Alternate operation (Self-resetting) (Self-holding) Operation Unit color symbol SPDT DPDT * only. LED 24 VDC J-90A3-24E@@ J-90B3-24E@@ Enter the desired color symbol for the Pushbutton 28 VDC J-90A3-28@@ J-90B3-28@@ in @@. R (Red) LED 24 VDC J-90C3-24E@@ J-90D3-24E@@ Y (Yellow) G (Green) W (White) 28 VDC J-90C3-28@@ J-90D3-28@@ A (Blue) * Microloads Single screen Vertical 2-split screen Output SPDT DPDT Contact type Microload (25 VAC, 0. A; 30 VDC 0. A) Operation Operation Lighting Momentary operation (Self-resetting) 5 VDC J-90E-05E@ LED 2 VDC J-90E-2E@ 24 VDC J-90E-24E@ 6 VAC/VDC J-90E-06@ 4 VAC/VDC J-90E-4@ 28 VAC/VDC J-90E-28@ LED 5 VDC J-90G-05E@ 2 VDC J-90G-2E@ 24 VDC J-90G-24E@ 6 VAC/VDC J-90G-06@ 4 VAC/VDC J-90G-4@ 28 VAC/VDC J-90G-28 @ Unit color symbol Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) Output SPDT DPDT Contact type Operation Lighting * only. Microload (25 VAC, 0. A; 30 VDC 0. A) Operation Momentary operation (Self-resetting) LED 24 VDC J-90E3-24E@@ 28 VDC J-90E3-28@@ LED 24 VDC J-90G3-24E@@ 28 VDC J-90G3-28@@ Unit color symbol Enter the desired color symbol for the Pushbutton in @@. R (Red) Y (Yellow) G (Green) W (White) A (Blue) * Individual models: Refer to pages 6 to 9. (The Pushbutton, Lamp, and Switch can be ordered separately.) Specifications: Refer to page 2. Dimensions: Refer to page 4. Accessories: Refer to pages 0 to. 3

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Operation Unit, Lamp, and Socket Unit. Standard Loads Square Models Single screen A Single screen Output SPDT DPDT * only. Microloads Single screen Output SPDT DPDT LED Lighting LED LED Lighting LED * only. Contact type Standard load (250 VAC, 2 A; 25 VDC 0.4 A) Operation Momentary operation Alternate operation (Self-resetting) (Self-holding) 5 VDC A-90A-05E@ A-90B-05E@ 2 VDC A-90A-2E@ A-90B-2E@ 24 VDC A-90A-24E@ A-90B-24E@ 6 VAC/VDC A-90A-06@ A-90B-06@ 4 VAC/VDC A-90A-4@ A-90B-4@ 28 VAC/VDC A-90A-28@ A-90B-28@ 5 VDC A-90C-05E@ A-90D-05E@ 2 VDC A-90C-2E@ A-90D-2E@ 24 VDC A-90C-24E@ A-90D-24E@ 6 VAC/VDC A-90C-06@ A-90D-06@ 4 VAC/VDC A-90C-4@ A-90D-4@ 28 VAC/VDC A-90C-28@ A-90D-28@ Contact type Microload Operation (25 VAC, 0. A; 30 VDC 0. A) Momentary operation Operation Unit color symbol (Self-resetting) 5 VDC A-90E-05E@ 2 VDC A-90E-2E@ 24 VDC A-90E-24E@ 6 VAC/VDC A-90E-06@ 4 VAC/VDC A-90E-4@ 28 VAC/VDC A-90E-28@ 5 VDC A-90G-05E@ 2 VDC A-90G-2E@ 24 VDC A-90G-24E@ 6 VAC/VDC A-90G-06@ 4 VAC/VDC A-90G-4@ 28 VAC/VDC A-90G-28@ Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) Individual models: Refer to pages 6 to 9. (The Pushbutton, Lamp, and Switch can be ordered separately.) Specifications: Refer to page 2. Dimensions: Refer to page 4. Accessories: Refer to pages 0 to. 4

Ordering Information Illumination-only and Colored-illumination LED Models Illumination only describes LED models for which the screen color is the same whether the LED is lit or not. The screen simply becomes brighter when the LED lights. Example: Red LED Not lit Red Lit Red Color cap (red) Legend plate (transparent) Dispersion plate (milk-white) Display LED holder LED (red) Colored illumination describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED when the LED is lit. Example: Red LED Not lit White Lit Red Color cap (transparent) Legend plate (transparent) Dispersion plate (milk-white) Pushbutton LED holder LED (red) Ordering...With colored-illumination models, order the Display (Operation Unit), Lamp, and Socket Unit as shown in the following table. Single screen Display (Operation Unit) LED Socket Unit Rectangular models J-580 2-split screen Square models Rectangular models only A-580 J-592 Select the LED s to suit your desired coloration from the selection on page 9. Select from the Switches on page 9. 5

Ordering Information Ordering Individually... Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Ordering... Specify a model number from the following page. LED-lighted Models Operation Unit Lamp-lighted Models Operation Unit Lamp (LED) Lamp ( Lamp) DC-only SLL-@@E@ Standard SLL-@@ Socket Unit Socket Unit Ordering set combinations: Refer to pages 3 to 4. Specifications: Refer to page 2. Dimensions: Refer to page 4. Accessories: Refer to pages 0 to. 6

Ordering Information Ordering Individually...Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Operation Unit LED-lighted Models (LED is not built in.) Appearance Rectangular Models (2 LEDs) Square Models ( LED) Screen pattern Single screen 2-split screen * Standard split screen Reverse split screen One-color 2-split screen Display color (transparent legend plate built in) Note: The color cap is transparent when the display color is white. * Two-split screen configurations are given with the OMRON surface of the case downward. (transparent legend plate built in) White J-580 A-580 Red J-5802 A-5802 Green J-5803 A-5803 Yellow J-5805 A-5805 White/red J-590 White/green J-5902 White/yellow J-5904 Red/green J-5905 Red/yellow J-5907 Green/yellow J-5909 Red/white J-59 Green/white J-592 Yellow/white J-594 Green/red J-595 Yellow/red J-597 Yellow/green J-599 White/white J-592 Red/red J-5922 Green/green J-5923 Yellow/yellow J-5925 Ordering set combinations: Refer to pages 3 to 4. Specifications: Refer to page 2. Dimensions: Refer to page 4. Accessories: Refer to pages 0 to. 7

Ordering Information Ordering Individually... Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Operation Unit Lamp-lighted Models ( is not built in.) Appearance Rectangular Square Screen pattern Single screen 2-split screen * Standard split screen Reverse split screen Display color (transparent legend plate built in) Blue/green J-528 Yellow/green J-529 Yellow/blue J-5220 White/white J-522 One-color Red/red J-5222 2-split Green/green J-5223 screen Blue/blue J-5224 Yellow/yellow J-5225 Note: The color cap is transparent when the display color is white. * Two-split screen configurations are given with the OMRON surface of the case downward. (Legend plate not included) One White J-530 A-530 Red J-5302 A-5302 Green J-5303 A-5303 Blue J-5304 A-5304 Yellow J-5305 A-5305 Two s White J-532 Red J-5322 Green J-5323 Blue J-5324 Yellow J-5325 White/red J-520 White/green J-5202 White/blue J-5203 White/yellow J-5204 Red/green J-5205 Red/blue J-5206 Red/yellow J-5207 Green/blue J-5208 Green/yellow J-5209 Blue/yellow J-520 Red/white J-52 Green/white J-522 Blue/white J-523 Yellow/white J-524 Green/red J-525 Blue/red J-526 Yellow/red J-527 Ordering set combinations: Refer to pages 3 to 4. Specifications: Refer to page 2. Dimensions: Refer to page 4. Accessories: Refer to pages 0 to. 8

Ordering Information Ordering Individually...Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Lamp LED Lamp Operating voltage 5 VDC 2 VDC 24 VDC Color Model (DC only) Model (DC only) Model (DC only) Red SLL-05ER SLL-2ER SLL-24ER Yellow SLL-05EY SLL-2EY SLL-24EY Green SLL-05EG SLL-2EG SLL-24EG White SLL-05EW SLL-2EW SLL-24EW Note: The J (M2SJ) requires two LEDs for each Switch. The A (M2SA) requires one LED. Lamp Lamp type Operating voltage Standard Low-voltage 5 VAC/VDC SLL-06 SLL-06H 2 VAC/VDC SLL-4 SLL-4H 24 VAC/VDC SLL-28 SLL-28H Note: The low-voltage has an advantage in that it generates less heat. Switch (common to both LED models and incandescent -lighted models) Standard load Microload Contact type Silver contacts Gold alloy contacts Number of outputs 2 2 Appearance Rectangular models Square models Selection precautions Operation Momentary operation J-800 A-700 Use the Socket Unit in Alternate operation J-8020 A-7020 combination with the same shape Operation Unit Momentary operation J-8030 A-7030 (rectangular or square). Example: Alternate operation J-8040 A-7040 For the J-580 Rectangular Operation Unit, select Momentary operation J-8050 A-7050 the J-8@@0 Alternate operation J-8060 A-7060 Socket Unit. Momentary operation is Momentary operation J-8070 A-7070 self-resetting, and alternate operation is self-holding (i.e., Alternate operation J-8080 A-7080 push-on, push-off). 9

Ordering Information Accessories, Replacements, and Tools Accessories for Rectangular Models Name Appearance Classification Model Application precautions Barrier Short edge Barriers ( pair) Short intermediate Barriers Long edge Barriers ( pair) Long intermediate Barriers A-400 A-4002 J-4003 J-4004 The purpose of a Barrier is to prevent malfunctioning and to improve design image of the mounting panel. There is one intermediate Barrier and one pair of edge Barriers (2 Barriers). Mount Short Barriers horizontally. Mount Long Barriers vertically. Switch Guard J-5050 Cannot be used with Barrier or Seal Cover. Seal Cover J-5060 Cannot be used with Barrier or Switch Guard. Cap material: Vinyl chloride Long Mounting Plate pair J-3002 Use when vertically mounting individual (with Barrier) or multiple Switches (in standard mounting style and with Barrier). A Short Mounting Plate is attached to the Switch; replace it with the long one. Accessories for Square Models Barrier Name Appearance Classification Model Application precautions Short Edge Barriers ( pair) A-400 The purpose of the Barrier is to prevent malfunctioning and to improve design image of the mounting Short Intermediate Barrier A-4002 panel. Switch Guard A-5050 Cannot be used with Barrier or Seal Cover. Seal Cover A-5060 Cannot be used with Barrier or Switch Guard. Cap material: Vinyl chloride Accessory mounting: Refer to page 9. 0

Ordering Information Accessories, Replacements, and Tools Replacements for Rectangular Models Name Appearance Classification Model Application precautions Wire-wrap terminals J-404 Socket PCB terminals J-405 Sockets cannot be used for multiple mounting. Solder terminals J-406 Dispersion plate Milk-white Single screen J-507 Color cap Transparent White Red Green Blue Yellow Transparent White Red Green Blue Yellow Single screen 2-split screen J-5600 J-560 J-5602 J-5603 J-5604 J-5605 J-5630 J-563 J-5632 J-5633 J-5634 J-5635 Contact your OMRON representative for color changes or inscribing. If LEDs are to be used, use a color cap that matches the LED color. The blue color cap is only for incandescent s. Legend plate Transparent Milk-white J-4204 J-4203 A transparent legend plate is mounted on the Operation Unit. Replacements for Square Models Name Appearance Classification Model Application precautions Wire-wrap terminals A-40 Socket PCB terminals A-402 Sockets cannot be used for multiple mounting. Solder terminals A-403 Dispersion plate Color cap Legend plate Milk-white A-507 Transparent White Red Green Blue Yellow A-5600 A-560 A-5602 A-5603 A-5604 A-5605 Contact your OMRON representative for color changes or inscribing. If LED colors are to be used, use a color cap that matches the LED color. Transparent A-4204 A transparent color cap is mounted to a standard Display. Legend plates cannot be used, however, Milk-white A-4203 with Displays for incandescent s. Tools Name Appearance Classification Model Application precautions Extractor A3PJ-5080 Convenient for extracting the Operation Unit. Accessory mounting: Refer to page 9.

Specifications Approved Standard Ratings UL (File No. E455), CSA (File No. LR45258) Standard Load: 3 A at 25 VAC 2 A at 250 VAC Microload: 0. A at 25 VAC 0. A at 30 VDC Note: Certification has been obtained for the Switch Unit. For detailed information on individual products that have received certification, consult your supplier. Ratings For Standard Loads Rated voltage 25 VAC 250 VAC 8 VDC 4 VDC 30 VDC 25 VDC 250 VDC Note:. The above values are for steady-state currents. 2. Inductive load: Power factor = 0.4; time constant = 7 ms. 3. The load has an inrush current of 0 times the steady-state current. 4. The motor load has an inrush current of 6 times the steady-state current. The rated values are for testing conducted under the following conditions. () Ambient temperature: 20±2 C (2) Ambient humidity: 65% ±5%RH (3) Operating frequency: 20 times/min For Microloads Rating Minimum applicable load LED Lamp Type DC only Lamp Applied voltage Non-inductive load (A) Inductive load (A) Resistive Inductive Lamp load Motor load load load NC NO NC NO NC NO NC NO 3 2 3 3 2 0.4 0.2 0.7 0.05 0.03 0.7 0.5 2.5 2.5.5 0.4 0.2 0. A at 30 VDC (resistive load); 0. A at 25 VAC (resistive load) Applied voltage ma at 5 VDC Rated voltage Rated current.5.5.5 0.05 0.03 0.7 Built-in limiting resistance 5 VDC±5% 5 VDC 30 ma 39 Ω 2 VDC±5% 2 VDC 5 ma 270 Ω 24 VDC±5% 24 VDC 2.5 ma 300 Ω Rated voltage Standard Rated current Low-power Rated current 5 VAC/VDC 6 VAC/VDC 200 ma 00 ma 2 VAC/VDC 4 VAC/VDC 80 ma 40 ma 24 VAC/VDC 28 VAC/VDC 40 ma 25 ma Characteristics Operating Mechanical frequency Electrical Insulation resistance Contact Standard load resistance Microload Between terminals of same polarity Dielectric strength Between terminals of different polarity Between currentcarrying metal part and ground Between each terminal and non-current-carrying metal part Between terminals *. With alternate operation models, 60 operations/min max. One operation cycle consists of set and reset operations. *2. With no incandescent or LED mounted. *3. Malfunction : ms max. Operating Characteristics Momentary operation models: 20 operations/min max. * 20 operations/min max. 00 MΩ min. (at 500 VDC) 50 mω max. (initial value) 50 mω max. (initial value),000 VAC, 50/60 Hz for minute 2,000 VAC, 50/60 Hz for minute 2,000 VAC, 50/60 Hz for minute 2,000 VAC, 50/60 Hz for minute,000 VAC, 50/60 Hz for minute *2 Vibration resistance Malfunction 0 to 55 Hz,.5-mm double amplitude *3 Shock Destruction 500 m/s 2 max. resistance Malfunction 200 m/s 2 max. *3 Life expectancy Mechanical Electrical Weight Inrush NC current NO Ambient operating temperature Ambient operating humidity Ambient storage temperature Degree of protection Electric shock protection class Momentary operation models:,000,000 operations min. Alternate operation models: 00,000 operations min. (One operation consists of set and reset operations.) 00,000 operations min. (rated load) Approx. 0 g Standard load: 0 A max. Standard load: 0 A max. 0 to 50 C (with no icing or condensation) 35% to 85% RH 25 to 65 C (with no icing or condensation) IP00 Class II PTI (proof tracking index) 75 Pollution degree 3 (IEC 60947-5-) Operating characteristics Operation Momentary operation models Alternate operation models Operating force OF max. 3.92 N 4.90 N Releasing force RF min. 0.49 N 0.294 N Total travel TT Approx. 3 mm Approx. 3 mm Pretravel PT max. 2.2 mm 2.2 mm Lock travel alternate LTA min. 0.5 mm Contact Form Name Contact Form Double-throw contacts COM NC NO 2

Nomenclature Model Structure Operation Unit Structure Color cap Legend plate * Dispersion plate LED/incandescent holder Operation Unit Rectangular Models J Square Models A * Not included for the Square Models (A) with incandescent. Screen pattern Single screen Vertical 2-split screen Operation Unit colors LED-lighted models White, Red, Green, Yellow -lighted model White, Red, Green, Blue, Yellow Socket Unit Standard load 250 VAC, 2 A 25 VAC, 3 A 30 VDC, 2 A Microload 25 VAC, 0. A 30 VDC, 0. A Lamp Lighting method LED Note: The J is shown here as an example. 3

Dimensions The Dimension shows 2-switch outputs. (Unit: mm) Rectangular Models (J) OMRON logo 0.5 Square Models (A) OMRON logo 0.5 9.4 8.2 4. 9. 22±0.2 3.2 0.4 5.8±0.2 4.5.2.8 7.8±0.2 3.2 5.8±0.2 2.8 7.8±0.2 3.2 5.8±0.2 2.8 24±0.2 4.2.8±0. Terminal Arrangement Bottom View (All are shown with the OMRON logo facing down.) 32.5 40 Tab terminal #0 Note: Unless specified, a tolerance of ±0.4 mm applies for all dimensions. Use a mounting panel thickness of to 4 mm. Rectangular Models (J) Square Models (A) SPDT DPDT SPDT DPDT 7.8±0.2 4.2.8±0. 32.5 40 Tab terminal #0.8 LA+ NC NO C 4. 9. LB+ 8.8.5.8 LA+ LA- NC NC2 LA- LB- NO NO2 LB- LB+ C C2 8.2 4. 9..5 8.8.8 0.5 NC L+ NO 8.8 L- C 0.4 2.8 0.5 NC NC2 L+ 8.8 NO NO2 L- C C2 2 4.5 0.4 Note: The arrangements given above are not indicated on the Socket Unit. Contact Type Lamp-lighted Models (The terminal arrangements are the same as for the LED-lighted models.) Type Model Rectangular Models (J) Square Models (A) BOTTOM VIEW TOP VIEW BOTTOM VIEW TOP VIEW SPDT NC LA+ LB- NO LA- LB+ C NC L+ NO L- C Terminal arrangement Lighting block Terminal arrangement Lighting block BOTTOM VIEW TOP VIEW BOTTOM VIEW TOP VIEW DPDT NC LA+ LA- C NC2 LB- NO2 LB+ C2 NO NC NC2 L+ NO NO2 L- C C2 Terminal arrangement Lighting block Terminal arrangement Lighting block LED Lamp-lighted Models Type Model Rectangular Models (J) Square Models (A) BOTTOM VIEW TOP VIEW BOTTOM VIEW TOP VIEW SPDT LB- NC LA+ NO LA- C LB+ NC L+ NO L- C Terminal arrangement Lighting block Terminal arrangement Lighting block BOTTOM VIEW TOP VIEW BOTTOM VIEW TOP VIEW DPDT NC NC2 LA+ LB- NO LA- LB+ NO2 C C2 NC NC2 L+ NO L- C NO2 C2 Terminal arrangement Lighting block Terminal arrangement Lighting block 4

Dimensions (Unit: mm) Panel Cutout (If using a Switch Guard or Seal Cover, refer to the panel cutout diagrams on page 7.) Rectangular Models (J) Classification Mounting design Panel cutout Remarks Individual mounting, horizontal 7.8 ±0.2 24±0.2 22.4±0.2 Panel cutout spacing between rows of Units: Flange mount models Multiple mounting, horizontal Individual mounting, vertical 7.8±0.2 2 n 24 ±0.2 24n±0.5 Mount to Long Mounting Plate (J-3002) before use. 22.4±0.2 24n-.6 ±0.2 6 min. 3 min. 7.8 ±0.2 6.2 ±0.2 Multiple mounting, vertical 24 ±0.2 2 n Mount to Long Mounting Plate (J-3002) before use. 22.4±0.2 7.8n±0.5 7.8n-.6 ±0.2 Individual mounting, horizontal 9.8 6.2 ±0.2 29.7 26.9 ±0.2 Panel cutout spacing between rows of Units: Barrier mount models Multiple mounting, horizontal Individual mounting, vertical Multiple mounting, vertical 9.8 2 n 26 23.5 25.3n+4.4 26 2 n 9.n+4.4 Mount to Long Mounting Plate (J-3002) before use. Mount to Long Mounting Plate (J-3002) before use. 6.2 ±0.2 22.4±0.2 22.4±0.2 25.3n+.6±0.2 20.7±0.2 9.n+.6 ±0.2 * If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating..4 6 min. 4 min. Dotted line indicates the position of each mounting Barrier. Square Models (A) Classification Mounting design Panel cutout Remarks Flange mount models Barrier mount models Individual mounting Multiple mounting Individual mounting Multiple mounting 7.8±0.2 7.8±0.2 7.8±0.2 2 3 n 9.8 23.5 7.8n±0.5 9.8 2 3 n 9.n+ 4.4 7.8n-.6±0.2 20.7±0.2 9.n+.6 ±0.2 * If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. Panel cutout spacing between rows of Units: 6 min. 3 min. Panel cutout spacing between rows of Units:.4 4 min. 6 min. Dotted line indicates the position of each mounting Barrier. 5

Dimensions (Unit: mm) Accessory Mounting Dimensions Legend Plate Rectangular Models J-4203/-4204 Square Models A-4203/-4204 Extractor A3PJ-5080 5 20 2.5 2.5 5 0 8.4 0-0..6 0-0..5 0-0..6 0-0. 50 0.3 0.8 0.8 25±2 Note: Made from stainless steel. Socket-mounting Dimensions Rectangular Models Wire-wrap Terminals J-404 Solder Terminals J-406 PCB Terminals J-405 2.2 2.2 2.2 23.6 23.6 23.6 0.3 5 5 5 5.7±0.6 8.2 0.5 3.6 7.6 3 7.6.2 3 7.6 47.5 47.5 47.5 Terminal Hole Dimensions 0.9R 0.6R 3 PCB Cutout (Bottom View) 2.9.5 3.2 0.8.8 8.8.5 2.9 Ten,.5-dia. holes.65 8.2 4. 9. 2.85 6

Dimensions (Unit: mm) Square Models Wire-wrap Terminals A-40 2.2 Solder Terminals A-403 2.2 PCB Terminals A-402 2.2 7.6 7.6 7.6 0.3 5 5 5 5.7±0.6 8.2 0.5 3.6 7.6 3 7.6.2 3 7.6 47.5 47.5 Terminal Hole Dimensions 0.9R 0.6R 3 0.8 3.2 47.5 PCB Cutout (bottom view) 5.0 0.4 2.9 4.5 2.2.8 8.8 Eight,.5-dia. holes The OMRON logo is downward on the Socket Unit. Switch and Guard Mounting Dimensions Rectangular Models J-5050 Panel Cutouts Individual Mounting 22.4±0.3 Square Models A-5050 Panel Cutouts Individual Mounting Transparent plate OMRON logo Transparent plate OMRON logo 20 20 26 20 Switch Guard (J-5050) Multiple Mounting, horizontal Switch Guard (A-5050) Multiple Mounting, horizontal 26n-3.6±0.2 20n-3.8±0.2 20 +0-0.2 20 +0-0.2 26 +0-0.2 3.7 39.2 9±0. 8.5 min. 20 +0-0.2 3.7 39.2 9±0. 8.5 min. Seal Cover Mounting Dimensions Rectangular Models ASJ-5060 Panel Cutouts Individual Mounting 22.4±0.3 Square Models A-5060 Panel Cutouts Individual Mounting Transparent plate OMRON logo Transparent plate OMRON logo Seal Cover (J-5060) Black Multiple Mounting, horizontal 22.4±0.3 8.5 min. Seal Cover (A-5060) Black Multiple Mounting, horizontal 8.5 min. 24.3 24.3 30.5 8.3 3.8 39.3 8.5 min. 24.3 8.3 3.8 39.3 8.5 min. Note:. Recommended panel thickness:.0 to 3.3 mm 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 7

Safety Precautions Refer to Safety Precautions for All Pushbutton Switches/Indicators. Precautions for Correct Use Mounting LED Lamp Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electric shock or fire may occur. Wiring For wiring, use a wire size that is appropriate for the applied voltage and the supplied current. Be sure to perform soldering according to the following conditions. Using the Switch with incomplete soldering may result in errors and heat, which may cause fire. () Manual soldering: Use a soldering iron with a tip temperature of 350 C maximum and complete soldering within 3 seconds. (2) Dip soldering: Solder at 350 C for 3 s or less. Wait for one minute after soldering before exerting any external force on the solder. Use non-corrosive liquid rosin as the flux. If screw-tightened terminals are used, hold the Socket Unit Set or Socket Unit and install the lead wiring applying a torque of less than 0.98 N m to the Socket Unit. Applying a torque of more than 0.98 N m may result in damage. The tightening torque is 0.59 to 0.78 N m. Make sure that the insulating sheath of the wires does not come in contact with the Unit. If wiring is performed with the insulating sheath of the wires coming in contact with the Unit, use wire with a minimum heat resistance of 00 C. After wiring the Switch, make sure that there is a suitable isolation distance. Operating Environment Do not use in locations that are subject to dust, oil, or metal fillings, because these may penetrate the interior the Switch and cause malfunction. Using Microloads Using a standard load switch when a microload circuit is opened or closed may cause wear on the contacts. Use the switch within the operating range. (Refer to the diagram below.) Even when using microload models within the operating range shown below, if inrush current occurs when the contacts are opened or closed, it may cause the contact surface to become rough, and so decrease life expectancy. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation λ 60 = 0.5 x 0 6 /time indicates that the estimated malfunction rate is less than /2,000,000 with a reliability level of 60%. A current-limiting resistor for the LED is built in, so no external resistor is required. Rated voltage Built-in limiting resistance 5 VDC 39 Ω 2 VDC 270 Ω 24 VDC 300 Ω Lamp It is advantageous in terms of service life and heat generation to apply 80% of the rated voltage (operating voltage) to the incandescent. Operation Always mount the Operation Unit before operating the Switch. (Using your fingers or tweezers to operate moving parts of the Switch may deform internal parts and cause malfunctions.) Character Film If the character film is to be specially prepared, use heat-resistant film with a maximum thickness of 0.2 mm..3±0.2 J A 8.2±0.2.3±0.2.3±0.2 Others If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. Voltage (V) 0.5 ma 26 ma 00 ma 30 24 Microload area Standard load area 2 5 Invalid area ma 00 ma 60 ma 0 0. 0 00,000 Current (ma) 8

Application Replacing and LED Lamps and Panel Mounting Removing the Display Grasp the groove on the color cap surface, and pull it firmly toward you to remove the Display. An Extractor (A3PJ-5080) is available to conveniently remove the Display. Barrier Mounting Place the Edge Barrier on the side of the Socket Unit, and then insert it into the panel. Insert the Intermediate Barrier between the Switches after inserting the Socket Units into the panel. Intermediate Barrier Edge Barrier Mounting and Replacing and LED Lamps Inscribing Legend Plate Characters Inscribing J (M2SJ) Inscription depth: 0.5 mm max. The legend plate is made of polycarbonate, so apply an alcoholbased paint coating, such as melamine, phthalate, or acrylic resin paint when marking the legend. Inserting the Display into the Socket Unit Insert the Operation Unit in the proper direction. With the OMRON logo downward, insert the Operation Unit so that the /LED terminals on the inside surface of the Unit case and the contactors of the Display. Terminals for incandescent or LED (built into the case) Contactors Legend plate When replacing the legend plate, be careful that the coil spring in the Display does not become removed. OMRON logo Rated Voltage and Color of LED The LED voltage rating is indicated on the base. Use the LED within ±5% of voltage range. Rated voltage Illuminating color (color band) Mounting to the Switch Panel Mount the Socket Unit to the panel by inserting it from the front of the panel. Mount the Socket Unit so that the OMRON logo is downward. 9

Assembling the Legend Plate (Plunger) A (M2SA) (LED Lamp) () Assemble the color plate to the plunger, and then assemble the legend plate on top. Legend plate Plunger ( Lamp) (2) Inscribe the surface of the plunger, and then coat the surface. Lighted Square Pushbutton Switches Assemble models A-530 to A-5305 so that the hook is toward you. Direction of inscription Dispersion plate Hook toward you Note: Legend plates cannot be used with A Displays for incandescent s. (3) Assemble the color cap to the inscribed plunger. Plunger Color cap (4) Push in the color in the direction of the arrow to assemble the plunger and the holder. Lighted Square Pushbutton Switches A Perform the assembly so that the wide groove and the hook on the plunger are in the same direction. Plunger Indicator M2SA Perform the assembly so that the wide groove and the hook on the plunger are in the same direction. 20

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 206.0 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 206 All Right Reserved.