STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Similar documents
PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 400 ekw 500 kva

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 225 ekw 281 kva

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

220 to volts. Electronic unit injection

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

DIESEL FEATURES GENERATOR SET

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Voltage 220 to or 1800 RPM

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

Specifications. 3406C Generator Set Electric Power

3412C Generator Set Electric Power. Specifications. Benefits and Features

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

Caterpillar 2500 kw 3516C

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

CONTINUOUS 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

Continuous, Prime, Standby, Mission Critical

STANDBY 200 ekw 250 kva

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 200 ekw 250 kva

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

Generator Set Specifications 100 ekw (125 kva)

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 350 ekw 438 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

Generator Set Specifications 60 ekw (75 kva)

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Transcription:

DIESEL GENERATOR SET STANDBY 1000 ekw 1250 kva Image shown may not reflect actual package. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES FUEL/EMISSIONS STRATEGY EPA Certified for Stationary Emergency Application (EPA Tier 2 emissions levels) DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. UL 2200 / CSA - Optional UL 2200 listed packages CSA Certified Certain restrictions may apply. Consult with your Cat Dealer. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat S O SSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT C32 ATAAC DIESEL ENGINE Utilizes ACERT Technology Reliable, rugged, durable design Four-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Electronic engine control CAT GENERATOR Designed to match the performance and output characteristics of Cat diesel engines Single point access to accessory connections UL 1446 recognized Class H insulation CAT EMCP 4 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway SEISMIC CERTIFICATION Seismic Certification available Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength. IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 Pre-approved by OSHPD and carries an OSP-0084-10 for use in healthcare projects in California

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Air cleaner Cooling Package mounted radiator Exhaust Exhaust flange outlet [ ] Exhaust mufflers (except Tier 4) Fuel Generator Primary fuel filter with integral water separator Secondary fuel filters Fuel priming pump Matched to the performance and output characteristics of Cat engines [ ] Oversize and premium generators [ ] Permanent magnet excitation (PMG) [ ] Internal excited (IE) [ ] Anti-condensation space heaters Power Termination Bus bar [ ] Circuit breakers, UL listed [ ] Circuit breakers, IEC compliant Control Panel EMCP 4 Genset Controller [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4 [ ] Generator temperature monitoring and protection [ ] Load share module [ ] Digital I/O module [ ] Remote monitoring software Mounting [ ] Rubber vibration isolators Starting/Charging General Paint - Caterpillar Yellow except rails and radiators gloss black [ ] Battery chargers [ ] Oversize batteries [ ] Jacket water heater [ ] Heavy duty starting system [ ] Charging alternator [ ] Air starting motor with control and silencer (3500 & C175 models only) The following options are based on regional and product configuration: [ ] Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 [ ] EU Certificate of Conformance (CE) [ ] UL 2200 package [ ] CSA Certification [ ] EEC Declaration of Conformity [ ] Enclosures- sound attenuated, weather protective [ ] Automatic transfer switches (ATS) [ ] Integral & sub-base fuel tanks [ ] Integral & sub-base UL listed dual wall fuel tanks 2

SPECIFICATIONS CAT GENERATOR Frame size... 1402 Excitation...Internal Excitation Pitch... 0.6667 Number of poles...4 Number of bearings...1 Number of Leads... 006 Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion - Consult your Caterpillar dealer for available voltages IP Rating... IP23 Alignment...Closed Coupled Overspeed capability...125 Wave form Deviation (Line to Line)... 002.00 Voltage regulator... 3 Phase sensing with selectible volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) CAT DIESEL ENGINE C32 TA, V-12, 4-Stroke Water-cooled Diesel Bore... 145.00 mm (5.71 in) Stroke... 162.00 mm (6.38 in) Displacement...32.10 L (1958.86 in 3 ) Compression Ratio... 15.0:1 Aspiration... TA Fuel System... MEUI Governor Type...ADEM A4 CAT EMCP 4 SERIES CONTROLS EMCP 4 controls including: - Run / Auto / Stop Control - Speed and Voltage Adjust - Engine Cycle Crank - 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions Digital indication for: - RPM - DC volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - ekw, kva, kvar, kw-hr, %kw, PF Warning/shutdown with common LED indication of: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Programmable protective relaying functions: - Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kw) (32) - Reverse reactive power (kvar) (32RV) - Overcurrent (50/51) Communications: - Six digital inputs (4.2 only) - Four relay outputs (Form A) - Two relay outputs (Form C) - Two digital outputs - Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Emergency stop pushbutton Compatible with the following: - Digital I/O module - Local Annunciator - Remote CAN annunciator - Remote serial annunciator 3

TECHNICAL DATA Open Generator Set - - 1800 rpm/60 Hz/480 Volts EPA Certified for Stationary Emergency Application (EPA Tier 2 emissions levels) Generator Set Package Performance Genset Power rating @ 0.8 pf Genset Power rating with fan Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Engine coolant capacity 1250 kva 1000 ekw 272.1 L/hr 71.9 Gal/hr 213.4 L/hr 56.4 Gal/hr 144.7 L/hr 38.2 Gal/hr 0.12 kpa 0.48 in. water 55.0 L 14.5 gal Inlet Air Combustion air inlet flow rate 87.6 m³/min 3093.6 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise 476.4 º C 889.5 º F 228.4 m³/min 8065.9 cfm 203 mm 8 in 10.0 kpa 40.2 in. water 352 kw 20018 Btu/min 1024 kw 58235 Btu/min 288 kw 16379 Btu/min 127 kw 7222 Btu/min 54.9 kw 3122.2 Btu/min 2734 skva 1402 125 º C 225 º F Lube System Sump refill with filter 99.0 L 26.2 gal Emissions (Nominal) 3 NOx g/hp-hr CO g/hp-hr HC g/hp-hr PM g/hp-hr 4.93 g/hp-hr.13 g/hp-hr.01 g/hp-hr.018 g/hp-hr 1 For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2 UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40ºC ambient per NEMA MG1-32. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Applicable Codes and Standards: AS1359, CSA C22.2 No 100-04, UL142, UL489, UL601, UL869, UL2200, NFPA 37, NFPA 70, NFPA 99, NFPA 110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, 72/23/EEC, 98/37/EC, 2004/108/EC Standby Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel Rates are based on fuel oil of 35º API (16º Cor 60º F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C(85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional Ratings may be available for specific customer requirements. Consult your Cat representative for details. 5

DIMENSIONS Package Dimensions Length 4234 mm 116.7 in Width 2010 mm 79.2 in Height 2174 mm 85.6 in NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing 434-5852). Performance No.: DM9933 Feature Code: C32DR35 Gen. Arr. Number: 432-6118 Source: U.S. Sourced 6 www.cat-electricpower.com 2013 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.