Generator. Jason S DiSanto. 6B Users Conference San Antonio, TX June 19-22, 2017

Similar documents
REAP CARE ROTATING ELECTRICAL ASSET PROGNOSTIC CARE

Inspection Testing Repair

New Generator Products

CF34-10A Turbofan Technical Manual Index November 1, 2018

CF34-1A/-3A/-3A2 Turbofan (Business Jet) Technical Manual Index September 1, 2018

CT7 Turboprop Technical Manual Index February 1, 2018

NEIL Turbine Generator Risk Assessment. Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013

Customer presentation, PG Service, BU Motors and Generators ABB LEAP Stator Winding-Condition & Lifetime assessment

Large Air Cooled Generator Failure

Dynamic Balancing. Need a high-speed balance? No problem.

Centro América Application of EMI Diagnostics to Diesel Generators

POWERING EVERYONE. Unlocking the Potential JULIO MESTRONI, APPLICATION ENGINEERING LEADER

New Robotic Technologies for Inspecting Two Pole Electric Generators while the Rotor Remains in Place

Generator Services. WGGS Capabilities Presentation

REVELSTOKE - 1 YEAR DOWN. Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004

Technical Manual Index March 1, 2018

Extended requirements on turbogenerators

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Automotive manufacturing accelerometer applications

MCE TM Product Information 5 kv Electric Motor Analyzer

INTER PLANT STANDARD STEEL INDUSTRY. CODE OF PRACTICE FOR REPAIR OF SQUIRRELCAGE HT MOTORS (6.6 kv) (First Revision) Corresponding IS does not exist

Solution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime

Automotive manufacturing accelerometer applications

Increasing the Power of the Turbogenerator in the Process Of Modernization in the Mining and Energy Industry

Wind Power Services. One Standard for Safety, Quality & Repairs Across North America INTEGRATED POWER SERVICES

Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure

LEAP - Life Expectancy Analysis Program For Electrical Rotating Machines. Marcio Gennari ABB Brazil Automation Products Machines Service Osasco

Wind Power Services. One Standard for Safety, Quality & Repairs Across North America INTEGRATED POWER SERVICES

APPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1

Double earth fault in a PSP during back to back launching sequence

F-class OpFlex controls advancements

Power-GEN Middle East

Condition Monitoring of Electrical Machines ABB MACHsense Solution

ECEg439:-Electrical Machine II

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

Hydro Plant Risk Assessment Guide

Pressurized Air Cooled Generators

Avio Aero. Collaborative network established in Clean Sky: a success story

DEVELOPMENT OF VIBRATION CONDITION MONITORING SYSTEM APPLYING OPTICAL SENSORS FOR GENERATOR WINDING INTEGRITY OF POWER UTILITIES

BA440 PISTON. Hydraulic Air Compressor

B kv Gas-insulated Substations

CF34-8 Technical Manual Index July 1, 2018

EMERGENCY EGRESS LIGHTING POWER SUPPLY BATTERY

CR193 Vacuum Limitamp* Contactors

1988 Chevrolet Pickup V SUSPENSION - FRONT (4WD)' 'Front Suspension - "V" Series 1988 SUSPENSION - FRONT (4WD) Front Suspension - "V" Series

Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved.

Sustainable Technology for True Inverter Duty Motors

2014 ELECTRICAL TECHNOLOGY

PROBLEMS WITH NEWER GENERATORS

Rosa Power Supply Company Limited (RPSCL) Rosa Unit-2 AVR Sensitivity

Life Cycle Management of Motors and Generators

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Operating instructions and spare parts list. XT08 Horizontal axis

Historical Development

The Case of Stator and Rotor Maintenance for Power Generator Unit 1 and 2 of Samcheonpo Thermal Power Plant

Contamination switch VS

AV-25 Rotating Equipment Health Machine Condition Monitoring-MCM

High Frequency SineWave Guardian TM

TURBO GENERATORS BEST QUALITY FOR THERMAL POWER PLANTS

Artesis MCM Case Studies. March 2011

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

MCset kv Medium voltage equipment

Service Bulletin Published by Sudden Service, Inc.

Installation, Operation and Maintenance Instructions. SLS Series Single Phase Disconnector

IMPORTANT INFORMATION

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

9 POWER TAKE-OFF 9.1 REAR ENGINE POWER TAKE-OFF (REPTO) ASSEMBLY FRONT MOUNTED POWER TAKE-OFF

Purging Air From Divider Block Lubrication Systems

GE Power & Water Power Generation Services

LEAP-X Program Update

UniSec Maintenance solutions

High Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP)

High Voltage Technology & Testing

Comprehensive Management of Hydrocarbon Storage Tanks Ageing

Synchronous Generators I. Spring 2013

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Maintenance Manual BARRIER SERVO ASSEMBLY F1510 SERIES

OPERATION, MAINTENANCE AND OVERHAUL INSTRUCTIONS FOR PB18 SERIES PORTABLE PUMPS

Standard Workshop Practices 01-03

BRAITHWAITE & CO. LIMITED PRICE BID FORMAT (PART-II)

Annex A-4 DIESEL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BALANCE OF PLANT GENERATOR DIESEL ENGINE

OWNERS MANUAL. Model No LB. PUSH BROADCAST SPREADER. Assembly Operation Maintenance Repair Parts

Independent Testing Laboratory for High Voltage Equipment

NZQA unit standard version 5 Page 1 of 6. Demonstrate knowledge of engine design factors and machining practices

Before equipment use, please read this operation manual carefully. Serial Number: Date Purchased:

34 th Hands-On Relay School

Pre-Trip or Interim Inspection of Heritage Steam Locomotives

OSP Battery Training. Craig Paoli Director Strategic Platforms July 13 th Copyright 2010 The Alpha Group. All Rights Reserved.

PARTS LIST / TECHNICAL GUIDE Perpetual Calendar/Alarm Chronograph Cal. 7T86A

SEMITOP2,3,4 Press-Fit

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Chapter 4 Ignition & Electrical Systems

18000 Pump Series Technical Guide

IGNITION COIL - 2.4L SPARK PLUG

ABB s new Gearless Mill Drive generation: Maintenance-friendly features raise availability and productivity

PROPELLER INSTALLATION & OPERATION MANUAL MODEL: GA200CN-3B

Synchronous Generators I. EE 340 Spring 2011

Electrical Machines -II

Transcription:

Generator Jason S DiSanto 6B Users Conference San Antonio, TX June 19-22, 2017

GE Power 2017, General Electric Company. GE Proprietary Information - The information contained in this document is General Electric Company (GE) proprietary information. It is the property of GE and shall not be used, disclosed to others or reproduced without the express written consent of GE, including, but without limitation, in the creation, manufacture, development, or derivation of any repairs, modifications, spare parts, or configuration changes or to obtain government or regulatory approval to do so, if consent is given for reproduction in whole or in part, this notice and the notice set forth on each page of this document shall appear in any such reproduction in whole or in part. The information contained in this document may also be controlled by the US export control laws. Unauthorized export or re-export is prohibited. This presentation and the information herein are provided for information purposes only and are subject to change without notice. NO REPRESENTATION OR WARRANTY IS MADE OR IMPLIED AS TO ITS COMPLETENESS, ACCURACY, OR FITNESS FOR ANY PARTICULAR PURPOSE. All relative statements are with respect to GE technology unless otherwise noted. 2

Fleet Trends & Lifecycle Considerations

Generator Lifecycle 6B NA Fleet Expect the worst Fleet populations are aging towards increased risk of rotor & stator rewinds, Now is the time to start planning for rewinds Plan for the best Trend past and current operational data, unit history and test & inspect data to manage operational risk level Take what comes Site specific conditions will dictate proactive vs. reactive maintenance approach

GEK 103566 Rev L

GEK 103566 Creating an Effective Generator Maintenance Program Revision L Updates Combining legacy GE with legacy Alstom Added Low Oxygen Stator Cooling Water System recommendations Combined Stator & Rotor Test and Inspections Added Retaining Ring & When to Remove Rotor recommendations Updated Rotor Life Management recommendations Borescope Inspection: Visual inspection through the end shields or cooler(s) Electrical tests per Tables 3 5 Robotic Inspection: Rotor In-Situ Inspection via Robotics Stator & Rotor Tests and Inspections per Tables 3 5 Terminology changes: 1 st Year Inspection (Major Scope) First Inspection Minor Inspection/ Inspection A Boroscope Inspection Major Inspection/ Inspection B Robotic Inspection MAGIC/DIRIS Robotics 6

GEK 103566 Creating an Effective Generator Maintenance Program Revision L Updates Inspection & Maintenance Intervals Rev K Rev L Alternate borescope and robotic inspections Follow figures 1 and 2 as examples 7

GEK 103566 Creating an Effective Generator Maintenance Program Revision L - Rotor Removal Recommendations Events or Trends Predicating Rotor Removal Abnormal operating events as listed in Section 2: Maintenance Planning Rotor vibration trends coupled with flux probe shorted turns or blocked ventilation passages Stator wedge looseness trends Air gap foreign object damage Stator winding insulation degradation indicated through DC leakage or Partial Discharge trending Required Maintenance or Repair Activities Rotor tooth and wedge inspection and repair to remove hardened material Rings off cleaning up to field rewind Partial or full stator re-wedge or retightening Core or wedge repair Partial or Full stator rewind Driving towards online trending, in-situ testing and inspection Rotor removal for repair purposes 8

Robotic Inspections

Robotic inspection by generator model Types of robotic inspections: In situ air gap inspections In situ retaining ring inspections Wedge tapping 10

In-Situ Retaining Ring Inspection GE utilizes an inspection robot to detect indications of impeding cracks with the rotor in or out. GEK 103566 inspection recommendations: 18-5 Retaining Rings: Visual at the borescope inspection NDT at the robotic inspection Customer benefits Shorter down time periods due to reduced dismantling (rotor in-situ ; end bells in place) without sacrificing safety and quality Increased generator availability with faster returns to service More accurate and reproducible assessments Supports condition-based maintenance program development 18-18 Retaining Rings: ID inspected each time they are removed NDT Prior to 30 years of service or 10K start\ stops Then every 10 years after or 2K start\ stops 11

Inspection Data 512 robotic inspections carried out between 2011-2016 were examined: 20 rotors pulled 3 forced outages 2 rotor ground. 1 Neg Sequence with arc strikes 2 Partial rewedge, 1 full rewedge 10 cases use visual, 2 field ground, 4 wedge test, 1 knife test, 3 electrical, 1 NDT, 1 vibration (>20) Electrical tests usually confirm other tests or conditions such as shorted turn and vibration 21 future recommendations 3 rewedge, 1 bump test, 17 visual findings Visual Inspection is the key inspection Data shows robots find the same visual defects as rotor out Wedge Testing is second key inspection Data shows WITS for TRS units is equivalent to rotor out 12

Generator Monitoring

Generator Health Monitor- Modules Moving to condition-based maintenance 14

Generator Health Monitoring Periodical Monitoring Continuous Monitoring L2 GOLD* Service Portable DAU Site visit twice a year Report on collected data L3 Service Permanently installed DAU Half yearly full report L4 Remote Service Permanently installed DAU Permanent data link & storage Weekly checks Quarterly full report L1 Sensors Permanently installed, including cabling & connection boxes (GE or most third party) * Trademark of General Electric Company 15

GHM - partial discharge Sensors Capacitive bus couplers Low frequency 9 nf sensors 1 Per phase + 1 at neutral point Monitoring Slot PD Void/delamination PD Surface PD Phase to phase PD Vibration sparking Partial discharge location Identification of Stator bar insulation condition Aging of insulation Semi-conductive coating deterioration Loose stator bars Generator contamination 16

GHM - rotor flux Sensors Rod-type probe Wedge mounted flip-up probe Wedge mounted pop-up probe Monitoring Rotor inter-turn short circuits Accurately identification of effected slot Magnitude of fault Trend deterioration Identification of Electrical breakdown of inter-turn insulation Mechanical breakdown of inter-turn insulation Carbon and oil contamination of windings Copper dusting due to excessive barring Turn to turn contact due to coil shorting, distortion or elongation 17

Rotor Flux case study Unit experienced a field ground trip due to a problem with the main terminal stud Rotor Flux Monitor had indicated 3 shorted turns in coil #8 Unit was shutdown and the rotor removed Coil #8 was removed for repair. This was a high impedance fault. 18

GHM - rotor shaft voltage Sensors Shaft grounding with copper braids Good contact even at high surface velocity High performance in contaminated conditions (oil and dirt) Monitoring Electric discharge Shaft magnetization Shaft rubbing Grounding problems Brush sparking Rotor interturn faults Identification of Bearing damage Electro pitting Voltage tracking Electric erosion Frosting Insulation breakdown 19

Questions?

GEK 103566 Creating an Effective Generator Maintenance Program Revision L Updates Inspection & Maintenance Intervals Examples 22

GHM collector health monitor Sensors Radio frequency current transformers Monitoring Milliamp variation in excitation current Disruption of current flowing from the collector brushes to the collector rings Trend the variation Identification of Sparking which is correlated to collector ring flashover 23

Collector health monitor case study Site had an outage in month 3 and was instructed to closely inspect the collector / brush assembly A brush was found that was heavily worn and the brush holder appeared to, at some point, have carried current The collector surface was found to have salt deposits and corrosion 24

GEK 103566 Creating an Effective Generator Maintenance Program Revision L Updates Rotor & Retaining Ring Life Management Rotor Life Management GENERATOR FIELD CHARACTERISTICS INSPECTIONS REQUIRED Retaining Ring Inspection- New guidance is given in this revision In-service and has a main body bore In-service with no main body bore Full suite of NDT inspections based on re-inspect recommendations Full suite of NDT inspections except bore inspections Recommendations going forward. First in-service inspection required at 20 years or 2000 starts/stops from COD. Re-inspect based on number of starts only; however, GE would reserve right to add year based recommendations dependent on age of the unit and/or operation profile. 2000 starts/stops will be the maximum recommendation. 18Mn-5Cr RR- older configuration Should be replaced due to history of stress corrosion cracking If not at a minimum inspected at each outage interval Borescope Inspections- Visual inspections should be completed Robotic Inspection- NDT should be completed 18Mn-18Cr RR- current configuration The ID inspected at each time they are removed using fluorescent penetrant NDT of the retaining ring prior to 30 years of service or 10,000 start/ stops then every 10 years or 2000 start/stops 25

In-Situ (Air Gap) Inspection GE offers fast and reliable inspection of the turbo generator without the need to pull the rotor out. (OEM & OOEM) 1. Robotic Visual Inspection (via air gap) 2. Robotic Low Flux / EL-CID 3. Robotic Slot Wedging Tightness Test 4. HV tests 5. Brush gear inspection 6. Partial Visual Inspection (End winding) 7. Insulation Resistance Measurement 8. Rotor Inter Turn Short Circuit Detection (optional on Legacy GE) 9. Instrumentation check 10. Bump test (optional) Customer benefits Up to 40% time saving compared to conventional inspection with rotor out Reduced costs by keeping rotor in, simplify crane support and lay down space Several robots to fit a broad range of generator types Reduced risk during overhauls due to reduced dismantling Accurate and reproducible assessments Faster Return to Grid without sacrificing safety and quality Supports condition-based maintenance program development 26

Wedge tapping Applicable to units with a conformal wedging system Methods including acoustic tapping and hardness measurement rely on very low force applied to the wedge surface The resulting response is different for a tight wedge vs. a loose wedge. These methods are very sensitive but prone to variation due to wedge surface condition, oil, grease, and paint. 27