Unilift KP 150, KP 250, KP 350

Similar documents
GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Grundfos MAGNA, Relay Module

Grundfos.bk Page 1 Thursday, June 11, :59 PM GRUNDFOS INSTRUCTIONS. CRN MAGdrive. Installation and operating instructions

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

UP Series 200 GRUNDFOS INSTRUCTIONS. In-line, wet-rotor, single-speed, circulator pumps UP 43-70, UP , UP 53-45, UP 53-46

GRUNDFOS INSTRUCTIONS SQ, SQE. Installation and operating instructions

TPAK Series COOLANT PUMP

Submersible Tank Pump

CR30 CR60 (Model B) CR

TPHK Series Immersible Pump

TPHK Series Immersible Pump

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

6. Electrical. 7. Settings. 8. Quick

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Redi-Flo4. Stainless Steel Submersible Pumps for Environmental Applications GRUNDFOS INSTRUCTIONS. US Installation and operating instructions

GRUNDFOS GROUNDWATER SERVICE MANUAL 300S. Parts List Submersibles. Contents Parts List Special Tools Standard Tools Part Dimensions

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

GRUNDFOS GROUNDWATER SERVICE MANUAL 230S. Parts List Submersibles. Contents Parts List Special Tools Standard Tools Part Dimensions

GRUNDFOS INSTRUCTIONS MTA 110H-180. Installation and operating instructions

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Unilift CC 7-A1 (240V,0.25kW, L/sec,1-7m)

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

PRE-PLUMBED SEWAGE SYSTEM

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUBMERSIBLE SUMP PUMPS

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

GRUNDFOS INSTRUCTIONS JP-PS. Jet Pumps (JP) with Pressure Switch (PS) Installation and operating instructions

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SQFlex battery back-up system

AUTOMATIC SUBMERSIBLE UTILITY PUMP

ESE Series Cast Iron Sewage Pumps

GRUNDFOS DOSING SYSTEMS

GRUNDFOS MAGNA Series 2000 MAGNA , , 65-60

SUNC3000 / Item #40885

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

SUBMERSIBLE PUMP HSE RANGE

Matala. VersiFlow Series. Instruction and Maintenance Manual

SUBMERSIBLE PUMP HSE RANGE

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

GROUNDWATER PRODUCTS

GeyserMax-Flow Series

SUBMERSIBLE WATER PUMP

GRUNDFOS INSTRUCTIONS. Hydro Multi-B. Installation and operating instructions

2 Stainless Steel Submersible Pumps for Environmental Purge & Sampling Applications

StormPro BA Series Sump Pump

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SUBMERSIBLE POND PUMP

GRUNDFOS VERSAFLO up(s) THE QUIET REVOLUTION. Grundfos VersaFlo UP(S) Wet Rotor Circulators

SUPER PUMP OUT SYSTEM

Operating Manual Includes Pumps: PG-9000 Part #R809606

SUBMERSIBLE DIRTY WATER PUMP

GARDEN HOSE UTILITY PUMP

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

SUBMERSIBLE WATER PUMP

SL1, SLV Pumps GRUNDFOS PRICE BOOK

SUBMERSIBLE WATER PUMPS

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

SUBMERSIBLE MINI-PUMP

SUBMERSIBLE SWIMMING POOL DRAINER

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

SHALLOW WELL JET PUMP

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Ion Technologies WC33 Submersible Sump Pump

STAR STOP SHALLOW WELL JET PUMP

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Oxiperm 164 and 166 GRUNDFOS PRODUCT GUIDE. Automated preparation of chlorine dioxide

GRUNDFOS PRODUCT GUIDE LM, LP. Single-stage close coupled in-line circulating pumps 60 Hz

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

OPERATION & MAINTENANCE INSTRUCTIONS

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

StormPro BCV400 Sewage Ejector Pump

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Owner s Manual Drill and Light Weight Portable Utility Pumps

Powerful & Intelligent Submersible Pumps

OPERATION & MAINTENANCE INSTRUCTIONS

Submersible Pond Pump with UV 800 Gallons Per Hour

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

grundfos smartflo SmartFlo System Sizing Pocket Guide Curves and sizing information for all SmartFlo systems

SUBMERSIBLE WATER PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

HALLMARK INDUSTRIES INC

Transcription:

GRUNDFOS INSTRUCTIONS Unilift KP 150, KP 250, KP 350 Installation and operating instructions DRAINAGE PUMP 1Z28

LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. Grundfos' liability under this warranty shall be limited to repairing or replacing at Grundfos' option, without charge, F.O.B. Grundfos' factory or authorized service station, any product of Grundfos' manufacture. Grundfos will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by Grundfos are subject to the warranty provided by the manufacturer of said products and not by Grundfos' warranty. Grundfos will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with Grundfos' printed installation and operating instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of Grundfos' products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact Grundfos or an authorized service station for instructions. Any defective product to be returned to Grundfos or a service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Material Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUEN- TIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WAR- RANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. 2

Unilift KP 150, KP 250, KP 350 Installation and operating instructions 4 Notice d installation et d entretien 9 Instrucciones de instalación y funcionamiento 15 3

CONTENTS Page 1. General description 4 1.1 Applications 4 1.2 Operating conditions 4 1.3 Sound pressure level 5 2. Electrical connection 5 3. Installation 5 3.1 Pipe connection 5 3.2 Basic requirements 5 3.3 Pump location and positioning 5 3.4 Adjustment of float switch 6 3.5 Non-return check valve 6 4. Operation 6 4.1 Starting 6 5. Maintenance 6 5.1 Cleaning the pump 6 5.2 Replacement of parts 7 6. Fault finding chart 8 7. Disposal 8 1. General description Fig. 1 Prior to installation, read these installation and operating instructions. Installation and operation must comply with local regulations and accepted codes of good practice. With float switch 1. Discharge port 1.25" NPT. 2. Handle. 3. Clamp. 4. Suction strainer. 5. Outer casing. 6. Float switch (optional). 1.1 Applications The Grundfos Unilift KP 150, KP 250 and KP 350 pumps are single-stage submersible pumps designed for pumping grey water. CAUTION: This pump has been evaluated for use with water, grey wastewater and heated wastewater. TM03 4327 2006 The pump is capable of pumping water which contains a limited quantity of spherical solids up to 3/8" in diameter without being blocked or damaged. The pump is suitable for automatic (with float switch) as well as manual operation and can be installed in a permanent installation or used as a portable pump. The pump is suitable for: Drainage of basements or buildings prone to flooding, Pumping of wastewater from washing machines, sinks, baths, showers, etc., up to the sewer level, Dewatering of sites or the pumping of water for fountains, Pumping in draining wells, Emptying swimming pools, ponds, tanks, or fountains. The pump is not suitable for pumping: sewage liquids containing long fibers liquids containing solid particles larger than 3/8" in diameter flammable liquids (oil, gasoline, etc.) aggressive liquids. Note: If the pump has been used for very dirty or chlorinated water it should be flushed thoroughly with clean water after use. The pump contains approx. 70 ml of non-poisonous motor liquid that may pollute the pumped liquid if the pump should leak. 1.2 Operating conditions Liquid temperature Minimum 32 F. The maximum liquid temperature depends on the rated voltage of the pump, see the table below. Voltage Do not use the pump in or at swimming pools, garden ponds, etc. when there are persons in the water. Maximum liquid temperature 1 x 115 V, 60 Hz +122 F (+113 F KP 350) At intervals of at least 30 minutes, the pump is allowed, however, to run at maximum +158 F for periods not exceeding 2 minutes. Storage temperature Not lower than 4 F. Minimum water level Water level must be above strainer inlet. Maximum installation depth 30 feet below liquid level. 4

5 1.3 Sound pressure level The sound pressure level of the pump is lower than the limiting values stated in the EC Council Directive 98/37/EC relating to machinery. A-weighted sound pressure level < 65 db(a) in accordance with ISO 3743. 2. Electrical connection The electrical connection should be carried out in accordance with local regulations and following the National Electrical Code. The pump should be grounded. The operating voltage and frequency are marked on the nameplate. Make sure that the motor is suitable for the electricity supply on which it will be used. When connecting the pump for manual operation, the 115V plug is inserted into a 115V outlet. If a float switch is included for automatic operation it will be of the "Piggy-back" design. Plug the 115V plug on the float switch into the 115V outlet, and plug the 115V plug from the pump into the float switch plug. Fig. 2 3. Installation 3.1 Pipe connection Steel or rigid plastic pipe can be screwed directly into the 1.25" NPT discharge port. For permanent installation, it is recommended to fit a union, a non-return valve and an isolating valve in the discharge pipe. Other recommendations: For portable or temporary installations, plastic discharge pipe can be used in conjunction with a suitable screwed/hose connector. Removal of the pump should be by a cable secured to the pump handle and not by the discharge pipework. Screwed threads should be sealed using Teflon tape. Note: The pump must not be installed hanging from the discharge pipe. 3.2 Basic requirements When the pump is installed in a permanent installation with a float switch, and the cable length is set to the minimum length of at least 2.5" inches, the minimum dimensions of the well should be as shown in fig. 3. Furthermore, the well should be sized according to the relation between the water flow to the well and the pump capacity. Fig. 3 3.3 Pump location and positioning Pumps without or with float switch can be used in vertical position with the discharge port uppermost or in horizontal or tilted position with the discharge port as the highest point of the pump. See fig. 4. When used in horizontal position, the pump must be completely covered by liquid. Fig. 4 When the pipe/hose has been connected, the pump is ready for use. Note: Do not lift the pump by means of the electric cable. Lift the pump by means of a cable secured to the handle of the pump. The Unilift KP pumps have built-in thermal overload protection and require no additional motor protection. If the motor is overloaded, it will stop automatically. When it has cooled to normal temperature it will start automatically. TM03 4461 2106 As a precaution, the pump must be connected to a socket with earth connection. It is recommended to fit the permanent installation with a ground fault circuit interrupter (GFCI) with a tripping current <30mA. 115V outlet Float switch plug ("Piggy-back") Pump plug TM03 4330 2006 TM00 1548 0493 ø 350 mm 400 mm 16 inches With float switch 14 inches

6 Before positioning the pump, make sure that the suction strainer will not be blocked or partly blocked by silt, mud or similar materials. This can be avoided by positioning the pump on bricks, an iron plate, etc. See fig. 5. Fig. 5 3.4 Adjustment of float switch The float switch can automatically turn the pump on and off. Switching the adjustment is possible by repositioning the float switch in the handle of the pump. The free cable length must always be: at least 2.5 inches no more than 6 inches. Fig. 6 The start/stop level varies according to the cable length. For manual operation, unplug both the pump and float switch from the 115V outlet. Plug the 115V plug on the pump into the outlet. 3.5 Non-return check valve Whenever the pump is installed in a permanent installation with a float switch, a non return valve must be fitted in the discharge pipe or hose. 4. Operation 4.1 Starting Before starting the pump, check: whether the pump is submerged in liquid. During normal operation, the strainer of the pump must be below the surface of the liquid whether the pump is positioned on a base so that the strainer is not blocked by silt, mud or similar materials whether the pipe/hose connection is tight whether the discharge pipe is open (bend of hose, etc.) whether the pump is connected to the electric supply in accordance with the instructions check the float switch for free movement. After start-up, check that: the pump operates properly, that water is being pumped, and the pump operates through the control sequence the float switch will allow the pump to pump down to a level of approximately 4". To pump out below this level secure the switch in the manual position. See 3.4 Adjustment of float switch. 5. Maintenance Under normal operating conditions, the pump is maintenance-free. If the pump has been used for liquids other than clean water, it should be flushed through with clean water immediately after use. 5.1 Cleaning the pump If the pump does not deliver a sufficient quantity of water because of sediment, dismantle and clean the pump. The dismantling of the pump is carried out as follows: 1. Disconnect the electricity supply. 2. Allow the pump to drain. 3. Carefully loosen the suction strainer by inserting a screwdriver in the recess between the outer casing and the strainer and pressing it hard. Repeat the procedure until the strainer is free and can be removed, see fig. 7. TM00 1549 0493 TM03 4331 2006 Cable length Min. 2.5" Cable length Max. 6" Start Stop Start Stop Unilift KP 150 Unilift KP 250 11.5" 5.5" 12,5" 3.5" Unilift KP 350 12" 6" 13 4" Min./max. cable length Start Stop As a precaution, the suction strainer must always be fitted to the pump during operation. Never dismantle the pump unless the electricity supply has been switched off. During dismantling, caution should be exercised as there will be access to sharp edges, etc. which may cut.

4. Check that the impeller can rotate freely. If not, remove the impeller: Slacken and remove the nut on the motor shaft (13 mm). Prevent the impeller from rotating by means of a screwdriver, see fig. 10. Clean the impeller and around the shaft. Fig. 7 4. Clean the suction strainer and refit it. If the pump still does not deliver a sufficient quantity of water, dismantle the pump as follows: 1. Disconnect the electricity supply. 2. Turn the pump housing 90 counter-clockwise using a screwdriver, see the arrow on the pump housing. Pull off the housing, see fig. 8. Pump housing Fig. 8 3. Clean and flush the pump with water to remove possible impurities between the motor and the outer casing. Clean the impeller, see fig. 9. TM03 4329 2006 TM03 1168 1205 Fig. 10 5. Check the impeller, the pump housing and the sealing part. Replace possible defective parts. 6. Assemble the pump in reverse order of dismantling. Note: Check before and when fitting the pump housing that the sealing part is positioned correctly, see fig. 11. Moisten the sealing part with water to facilitate the fitting. 5.2 Replacement of parts The impeller assembly and electric cord can be replaced. The part numbers and the components included in the service kits will appear from the tables below and fig. 11. Pump type KP 150, 60 Hz KP 250, 60 Hz KP 350, 60 Hz 10' 60HZ 25' 60HZ Impeller kit Replacement cords Part number 015783 015784 015786 016728 016729 TM03 1170 1205 Service kit Description Qty. Impeller kit Impeller 1 Nut 1 Gasket 1 TM03 1169 1205 If pump components other than those mentioned above are damaged or defective, please contact your pump supplier. Fig. 9 7

Electrical cord Impeller Nut Gasket Pump housing Strainer TM03 4328 2006 Fig. 11 6. Fault finding chart Fault Cause 1. Motor does not start. a) Supply failure. b) Pump switched off by float switch/vertical level switch. c) Fuses are blown. d) Thermal relay has cut out the electricity supply to the motor (see 2. Electrical connection). e) Check cable for defects. 2. Thermal relay trips out after short time of operation. 3. Pump runs but gives insufficient water. 4. Pump runs but gives no water. 7. Disposal This product or parts of it must be disposed of in an environmentally sound way: Use the public or private waste collection service. a) Temperature of pumped liquid higher than that stated in 1.2 Operating conditions. b) Pump partly blocked by impurities (see 4. Operation). c) Pump mechanically blocked (see 4. Operation). d) Check volts and amperage. e) Check cable for defects. a) Pump partly blocked by impurities (see 4. Operation). b) Discharge pipe/hose partly blocked. Check the non-return valve, if fitted. c) Check the impeller, the pump housing and the sealing part (see 4. Operation). a) Pump blocked by impurities (see 4. Operation). b) Non-return valve, if fitted, in discharge pipe/hose blocked in closed position. c) Liquid level is too low. During normal operation, the liquid level must be above the strainer. d) Pumps with float switch: The free cable of the float switch is too long (see 3.4 Adjustment of float switch). Subject to alterations. 8

21

22

U.S.A. GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 Canada GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Mexico Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L.C.P. 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010 Addresses revised 22.09.2005