No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Similar documents
THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

ON/OFF SERVO DIGITAL INDICATING CONTROLLER FCD-15A, FCR-15A INSTRUCTION MANUAL

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

User s Manual Power Supply IM E. 5th Edition

DIGITAL INDICATING CONTROLLER ACD-13A, ACR-13A INSTRUCTION MANUAL

Cylindrical Inductive Proximity Sensor GX-M SERIES

Hinged Safety Door Switch

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)


FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.

Lumitester PD-20 Control Kit

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

Chapter. Installation and. In this Chapter...

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

TOWA SEIDEN INDUSTRIAL CO., LTD.

System 3 ZB1PS Device Chassis. Operator s Manual

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Assembly instructions

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

Differential Pressure Transmitter

Not affected by drops, bubbles or froth

MEMS Gauge Pressure Sensor

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Direct Coupled Damper Actuator Model MY6050A1001

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

HOYMILES MICRO-IVERTER MI-250

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

High Vacuum Diaphragm-Type Dry Vacuum Pump

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

SLA Battery Capacity Analyzer

Pressure Transmitter

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

D4DL. Guard Lock Safety-door Switch. Model Number Structure

TOWA SEIDEN INDUSTRIAL CO., LTD.

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

RP Instruction Manual

Read and understand this manual for safely usage.

Model Pressure range ON/OFF output Linear output

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Battery Charger JCB- SCH20LI.2

Battery Charger JCB-FCH20LI2

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

EVS RP6020. Instruction Manual

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking

Electronic circuit breaker EBU10-T

Pressure sensor with built-in amplification and temperature compensation circuit

POWER REGULATOR LD -40PSU

PY-11 Voltage & Continuity Tester

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Installation Instructions for Load Management Kit A051C329

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

OPERATING MANUAL. Cole-Parmer Stir-Pak General-Purpose Laboratory Mixer. Model Number General-Purpose Laboratory Mixer System

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

TWIN HALOGEN SHOP LIGHT

MICRO-INVERTER OMNIKSOL M-300

362 Clamp Meter. Users Manual

KSZ 10B Current Probe Calibrator. Instruction Manual

Inductive Proximity Sensor

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

High-speed detection even a little liquid leak

Technical Manual Electrical Power Supply System T4002

EX Series. Electric Actuators for Ball and Butterfly Valves

Model Pressure range ON/OFF output Linear output

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Battery Charger JCB-FCH12Li

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Read and understand this manual for safely usage.

OPERATING INSTRUCTIONS

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Read and understand this manual for safely usage.

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

SeekTech Inductive Clamp

BPM2417SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

BEFORE USING THE PRODUCT

Transcription:

INSTRUCTION MANUAL LEVEL SWITCH LV-300 No.LV31JE2 2008.05 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. Safety Precautions (Be sure to read these precautions before using our products.) The safety precautions are classified into categories: Warning and. Depending on circumstances, procedures indicated by may be linked to serious results, so be sure to follow the directions for usage. Warning Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical damage or may degrade or damage the product, if not carried out properly. Warning To prevent an electric shock or fire, only Shinko or qualified service personnel may handle the inner assembly. To prevent an electric shock, fire or damage to instrument, parts replacement may only be undertaken by Shinko or other qualified service personnel. Safety precautions To ensure safe and correct use, thoroughly read and understand this manual before using this instrument. This instrument is intended to be used for industrial machinery, machine tools and measuring equipment. Verify correct usage after consulting purpose of use with our agency or main office. (Never use this instrument for medical purposes with which human lives are involved.) External protection devices such as overcurrent protection fuse, etc. must be installed, as malfunction of this product could result in serious damage to the system. Also proper periodic maintenance is required. This instrument must be used under the conditions and environment described in this manual. Shinko Technos Co., Ltd. does not accept liability for any injury, loss of life or damage occurring due to the instrument being used under conditions not otherwise stated in this manual. with respect to Export Trade Control Ordinance To avoid this instrument from being used as a component in, or as being utilized in the manufacture of weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the end users and the final use of this instrument. In the case of resale, ensure that this instrument is not illegally exported. Installation precautions This instrument is intended to be used under the following environmental conditions (IEC61010-1): Overvoltage category, Pollution degree 2 Ensure the mounting location corresponds to the following conditions: A minimum of dust, and an absence of corrosive gases No flammable, explosive gases No mechanical vibrations or shocks No exposure to direct sunlight, an ambient temperature of 0 to 55 (32 to 131 ) that does not change rapidly, and without icing An ambient non-condensing humidity of 35 to 85%RH No large capacity electromagnetic switches or cables through which large current is flowing. No water, oil or chemicals or where the vapors of these substances can come into direct contact with the unit Procedures which may lead to dangerous conditions and cause death or serious injury, if not carried out properly. 1

Wiring precautions This instrument has no built-in power switch, circuit breaker or fuse. It is necessary to install them near the instrument. (Recommended fuse: Time-lag fuse, rated voltage 250V AC, rated current 2A) Running and maintenance precautions Do not touch live terminals. This may cause electric shock or problems in operation. Turn the power supply to the instrunment OFF before retightening the terminal and cleaning. Working or touching the terminal with the power switched ON may result in severe injury or death due to Electric Shock. Use a soft, dry cloth when cleaning the instrument. (Alcohol based substances may tarnish or deface the unit.) Do not strike or scratch it with a hard object or press hard on it 1. Name of sections (4) (3) (2) (1) (5) (7) (6) (1): Cover (2): Case (3): Main unit mounting nut (4): Wing shaft fixing nut (5): Detector wing (6): Cabtyre cord (7): Solderless terminal (round type) (Fig. 1.1) 2

2. Mounting to hopper 2.1 Site selection and precautions Ensure the mounting location corresponds to the following conditions, and follow precautions below. (1) A minimum of dust, and an absence of corrosive gases (2) Few mechanical vibrations or shocks (3) No exposure to direct sunlight, an ambient temperature of 0 to 55 (32 to 131 ) that does not change rapidly, and without icing (4) Mount the instrument at the position where granule level actually changes. (5) If the granule load is large, mount an adequate guard plate. (6) Avoid mounting the instrument under the falling point of granules as well as near the outlet. (7) Mount the unit using the Main unit mounting nut. When it is difficult to set or remove the wing in a hopper, use a flange (sold separately). (8) Do not push and insert wing shaft too hard. Insert it up to the point with ease and then revolve it manually. 2.2 Mounting examples [Good example] Horizontal mounting Vertical mounting Empty room Level changing area (Fig.2.2-1) Area where material tends to accumulate (Fig.2.2-2) 3

For large loading (Mount the guard plate when the granule loading is large.) Empty room Guard plate Area where material tends to accumulate (Fig.2.2-3) [Bad example] Under the inlet Near the outlet Empty room (Fig.2.2-4) Area where material tends to accumulate (Fig.2.2-5) 4

Nut and flange mounting [Nut Mounting] Hopper [Flange Mounting] Hopper Flange Main unit mounting nut (Fig.2.2-6) (Fig.2.2-7) When using the LV-300 with a flange, make a hole on the hopper which enables the wing to enter. 2.3 Mounting of wing shaft (Fig.2.3-1) (Fig.2.3-2) (Fig.2.3-3) Insert the wing shaft up to the point where it can be inserted fully to the end position. When it is difficult to insert the wing shaft to the end, revolve the wing shaft manually clockwise or counterclockwise. (See Fig.2.3-2) Tighten the wing shaft with the fixing nut. (See Fig.2.3-3) 5

Notice Tighten the wing shaft fixing nut and main unit mounting nut with the specified torque as shown below, otherwise the screws will be damaged. (Table 2.3-1) Appropriate torque Maximum torque Wing shaft fixing nut 15 N m Within 30 N m Main unit mounting nut 20 N m Within 30 N m 2.4 External dimensions (Scale: mm) Detector length (L) 81 38 80 82 (Fig 2.4-1) 2.5 Hopper cutout (Scale: mm) Detector wing (L) Mounting direction 85mm 100mm 150mm 200mm Vertical mounting 250mm Vertical mounting Please specify the detector length when ordering. 27 +1 0 (Fig 2.5-1) 6

3. Terminal arrangement Warning Turn the power supply to the instrument OFF before wiring and checking. Working or touching the terminal with the power switched ON may result in severe injury or death due to Electric Shock. This instrument has no built-in power switch or fuse. It is recommended that power switch and fuse be set at the external circuit near this instrument. A C 1 2 3 Power supply Load Terminal code Lead wire color A White C Orange 1 Black 2 Brown 3 Green 4.3mm Solderless terminal for the cabtyre cord Use a solderless terminal in which an M4 screw fits as shown in (Fig 3-1). 8mm (Fig. 3-1) 4. Operation and action 4.1 Operation When mounting to the hopper and wiring are completed, check the action as follows. (1) Turn the power supply to this instrument ON. (2) Detector wing starts to revolve with no load. (Between terminal 1 and 2 is conducted. Between terminal 2 and 3 is open.) (3) When the load is added to the detector wing, the wing stops rotating. (Between terminal 1 and 2 is open. Between terminal 2 and 3 is conducted.) 7

4.2 Action When granule resistance is applied to the detector wing, the wing stops because the granule resistance keeps it from revolving. Micro switch between terminal 2 and 3 for internal load is conducted by the bar fixed on the motor. When the granule resistive load is given, power supply for the motor is disconnected because the micro-switch for the motor operates. When the granule level lowers, the detector wing is exposed, granule resistance does not work and the detector wing starts to revolve with the motor. Micro switch between terminal 1 and 2 for internal load is conducted at this time. 5. Specifications Name : Level switch Model name : LV-300 Torque : Detecting torque: 0.049N m (0.5kg cm) or more (fixed) Number of revolution : 1min -1 (60Hz) Supply voltage : 100V, 110V, 115V, 200V, 220/230V, 240V AC (Must be specified) 50/60Hz Allowable voltage fluctuation range : 15% of the Supply voltage Contact capacity : 3A 250V AC (resistive load) Ambient temperature : 0 to 55 Detector length : 85, 100, 150, 200, 250mm (Must be specified) Mounting : Nut screwing (Mounting part thickness: Maximum 7mm) Material Case, Cover : Aluminum die-cast Detector shaft : Stainless steel 8.0mm Detector wing : Stainless steel t1.5mm Lead wire : 5-core cabtyre cord, Length: 2m Weight (Including cabtyre cord 2m) Detector length 85mm 100mm 150mm 200mm 250mm Weight Approx. 645g Approx. 650g Approx. 670g Approx. 690g Approx. 710g Color Case, Cover : 7.5BG4/2.5 (munsell value) Dust-proof/Drip-proof structure : IP66 (excluding parts from the Main unit mounting nut to detector wing) Reg. Office URL E-mail SHINKO TECHNOS CO., LTD. OVERSEAS DIVISION : 2-5-1, Senbahigashi, Minoo, Osaka, Japan : http://www.shinko-technos.co.jp : overseas@shinko-technos.co.jp 8 Tel : Fax: 81-72-727-6100 81-72-727-7006