OWNER S MANUAL CLEAR ANSWER SOLID ANSWER

Similar documents
GB INSTRUCTIONS MANUAL

GENIX AUTOMATIC LIFTING STATIONS. Technical Sheet

ELECTRONIC CIRCULATOR FOR HEATING SYSTEMS

SUBMERSIBLE PUMPS AND MOTORS PRODUCT OVERVIEW

MICRA HS 3 HIGH SPEED MULTISTAGE SUBMERSIBLE ELECTRIC PUMP

OWNERS MANUAL ECODIVER

JET - JETINOX - EUROINOX WITH ACTIVE DRIVER PLUS INVERTER

DABPUMPS.COM SUBMERSIBLE PUMPS AND MOTORS PRODUCT OVERVIEW

SUBMERSIBLE BOREHOLE PUMPS AND MOTORS S4-4GG - 4OL

GENIX AUTOMATIC LIFTING STATIONS

DABPUMPS.COM INTEGRATED ELECTRONIC PRESSURE BOOSTERS DOMESTIC AND RESIDENTIAL APPLICATIONS

IT GB F D E NL SF P S RUS CZ SI SK HR SCG

1-2-3 KVC AD DOMESTIC CONSTANT PRESSURE BOOSTER SETS WITH ACTIVE DRIVER

SUBMERSIBLE WATER PUMP

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP

FEKA VS FEKA VX DRENAG

FKV SUBMERSIBLE PUMPS FOR SEWAGE

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

SUBMERSIBLE WATER PUMPS

SuperFlo 9,000 High Volume Pump Product Manual

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Matala. VersiFlow Series. Instruction and Maintenance Manual

AUTOMATIC SUBMERSIBLE UTILITY PUMP

US - UP2/OIL 12V US - UP2/OIL 24V

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

GeyserMax-Flow Series

PRESSURE BOOSTER 150

June14. Type

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

OPERATION MANUAL BATTERY CHARGER DFC-10P DFC-50P DFC-450P DFC-650P

Battery Charger JCB-FCH20LI2

c-go 24V/6A 24V/8A 24V/12A

INSTALLATION AND OPERATING INSTRUCTIONS. EXP Hurlcon Pumps CTX Series & BX Series. Bolero ND Cleaner

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

BIOXDPV 160/6 IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

SUBMERSIBLE SUMP PUMPS

BioCompact 25/50. Gebrauchsanleitung und Garantie Operating instructions and Guarantee

ESE Series Cast Iron Sewage Pumps

Owners Manual: - Pumps

Operating Manual Includes Pumps: PG-9000 Part #R809606

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

GARDEN HOSE UTILITY PUMP

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

TPHK Series Immersible Pump

TPAK Series COOLANT PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Unilift KP 150, KP 250, KP 350

Battery Charger JCB- SCH20LI.2

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

SUBMERSIBLE SUMP PUMPS

8000 / 10,000 / 12,000

Domestic Water Supply Pressure Pumps

StormPro BA Series Sump Pump

Sump Pump. Installation and Operating Instructions

US - UP2/E 12/24V

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

HydraPump Submersible Owner s Guide

6L Oil-less Air Compressor 53103

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Battery Charger JCB-FCH12Li

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

TPHK Series Immersible Pump

AXIAL FANS Axis / Tubo OPERATION MANUAL

2.0Ah BATTERY INSTRUCTION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS

Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

ALLEN GROUP INT L INC

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

PowerPlex 40V MAX Standard Battery Pack/Charger

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Owner s Manual Drill and Light Weight Portable Utility Pumps

Powerful & Intelligent Submersible Pumps

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

POND PUMP Model Nos:SPP3 & SPP6 0200

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Installation & Operating Manual

1/2 HP SUMP PUMP OWNER'S MANUAL

MP V 8A Electronic Smart Charger. Instruction and Information Manual

HST-BL-2830MS & HST-BL-2830MS-USA

StormPro BCV400 Sewage Ejector Pump

INSTALLATION AND OPERATING INSTRUCTIONS

Submersible Pond Pump with UV 800 Gallons Per Hour

US - UP3-R 12V US - UP3-R 24V

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

Transcription:

OWNER S MANUAL CLEAR ANSWER SOLID ANSWER

(IT) DICHIARAZIONE DI CONFORMITÀ CE Noi, DAB Pumps S.p.A. - Via M.Polo, 14 Mestrino (PD) Italy, dichiariamo sotto la nostra esclusiva responsabilità che i prodotti ai quali questa dichiarazione si riferisce sono conformi alle seguenti direttive: 2006/95/CE (Low Voltage Directive) 2004/108/CE (Electromagnetic Compatibility Directive) 2011/65/EU (Restriction of the use of certain hazardous substances in electrical and electronic equipment) ed alle seguenti norme: EN 60335-1 : 10 (Household and Similar Electrical Appliances Safety) EN 60335-2-41 : 05 (Particular Requirements for Pumps) (GB) DECLARATION OF CONFORMITY CE We, DAB Pumps S.p.A. - Via M.Polo, 14 Mestrino (PD) Italy, declare under our responsibility that the products to which this declaration refers are in conformity with the following directives: 2006/95/CE (Low Voltage Directive) 2004/108/CE (Electromagnetic Compatibility Directive) 2011/65/EU (Restriction of the use of certain hazardous substances in electrical and electronic equipment) and with the following standards: EN 60335-1 : 10 (Household and Similar Electrical Appliances Safety) EN 60335-2-41 : 05 (Particular Requirements for Pumps) Mestrino (PD), 01/01/2013 IT - Ultime due cifre dell anno di apposizione della marcatura: 13 GB - Last two gures of the year in which the mark was applied: 13 Francesco Sinico Technical Director

1. SAFETY MEASURES EN Before starting the pump, read this instruction booklet carefully. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. A 10mA or 30mA Residual Current Device (GFI) ) MUST be tted to the mains supply of the pump only. The power cord must never be used to carry or move the pump. Always use the pump s handle. NO OK OK Before taking any action on the pump, always remove the plug from the power socket. Never remove the plug by pulling on the power cord. If the power supply cord has been damaged, it must be replaced by the manufacturer or his authorized customer support service in order to avoid all risks. 1

EN Overload protection: The pump has a thermal overload safety device. In the event of any overheating of the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating. See Troubleshooting. 2. USE Multi-purpose submersible pumps with a high degree of reliability and safety designed to circulate water in garden ponds, create water falls and play water features. Designed to work in both horizontal and vertical installations CLEAR ANSWER models are suitable to pump clear water while SOLID ANSWER models can be employed for dirty water containing solid particles up to 30 mm in size. Circulating water in Garden ponds. Water falls. Fountains. Water features. The temperature of the uid being pumped must never exceed 35 C (95 F). The pump must not be used to pump salty water, sewage, in ammable, corrosive or explosive liquids (e.g. petrol, fuel, diluents), greases, oils or foodstuffs. If the power supply cord has been damaged, it must be replaced by the manufacturer or his authorized customer support service in order to avoid all risks. Before starting the pump, make sure that: the voltage and frequency speci ed on the pump s nameplate coincide with those of the available power supply; these pumps are designed for 115 Volt 60 Hz operation. there are no signs of damage to the pump or its power cord; the electric connection is made in a dry place, protected against any risk of ooding; Conformity with local and State electric codes is mandatory. The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying sump, utility, ef uent and all fountain pumps, pool pumps and other pond equipment. Consult a licensed electrician or your power company if in doubt. Note: given the different provisions applicable to the safety of electric systems in different countries, make sure that the pump system, as concerns its intended use, is in accordance with current local or state legislation. 2

EN 3. STARTING THE PUMP Insert the plug on the power cord in a suitable power socket. Start the pump Max 20 times an hour. 4. RECOMMENDATIONS To ensure the proper operation of the pump, it is important to comply with the following recommendations: The pump must never be allowed to run dry. Never leave the pump in operation when the delivery pipe is clogged. Place the pump in a vertical or horizontal position on a at surface at the bottom of the pond. Care should be taken not to seat the intake of the pump directly into mud or pond debris as this may cause the strainer to initially block. NO OK OK The pump must only be used when it is immersed in water. If the water runs out, the pump must be stopped immediately by removing the plug from the power supply. It is absolutely essential to prevent any risk of the pump freezing. In the event of freezing temperatures, remove the pump from the liquid, empty it and keep it in a place where it cannot freeze. Check the pump installation regularly to ensure the base inlet is clear of debris and that water is owing unrestricted. 3

EN (CLEAR ANSWER) Occosionally it may be necessary to clean the water intake chamber. Prise off the bottom plate. Thoroughly ush the inner cavity and impeller with clean water and replace the base moulding by pressing the pegs into the four retention bosses. Overload protection The pump has a thermal overload safety device. In the event of any overheating of the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating. See Troubleshooting. 5. TECHNICAL DATA Model Voltage/ frequency CLEAR ANSWER 1 115V 60Hz CLEAR ANSWER 2 115V 60Hz CLEAR ANSWER 3 115V 60Hz 4 SOLID ANSWER 4 115V 60Hz SOLID ANSWER 5 115V 60Hz SOLID ANSWER 6 115V 60Hz Power 260 w 370 w 820 w 235 w 320 w 880 w Max ow rate 1900 gph 2650 gph 4260 gph 1450 gph 1930 gph 3260 gph Maximum head 22 ft 30 ft 34 ft 11 ft 16 ft 29 ft Discharge 1 1/4 NPT 1 1/4 NPT 1 1/4 NPT 1 1/4 NPT 1 1/4 NPT 1 1/4 NPT

6. TROUBLESHOOTING EN Before taking any troubleshooting action, disconnect the pump from the power supply (i.e. remove the plug from the socket). If there is any damage to the power cord or pump, any necessary repairs or replacements must be handled by the manufacturer or his authorized customer support service, or by an equally-quali ed party, in order to prevent all risks. Fault Possible causes Solutions The pump does not run. Power cord unplugged. Plug cord securely into the socket and check if there is voltage on the line. The pump runs but does not deliver water. Pump stops running. Impeller jammed. Water level under the suction minimum. Air bubble in the pump, produced during the plunge. Suction lter clogged. Discharge tube clogged or obstructed. The thermal overload protection in pump has activated. Water Temperature exceeds 35 C. The pump ran dry Disconnect the power cord, disassemble hydraulic part and check if impeller is free to run. Stop the pump. Reposition pump to ensure pump is always fully submerged. Get the air out by plunging again the pump while in a tilted position and shake it with the discharge tube open. Disconnect the power cord, clean the hydraulic part. Disconnect the power cord: take off the tube and clean it. Clean water intake area. Allow pump to cool for approximately 30 minutes. Maximum water temperature must not exceed 35 C. Reposition pump to ensure pump is always fully submerged. 5

EN 7. GUARANTEE Any material or manufacturing defects will be corrected during the guarantee period established by current law in the country where the product is purchased. It is up to the manufacturer to decide whether to repair or replace any faulty parts. The manufacturer s guarantee covers all substantial defects attributable to manufacturing or material defects, providing the product has been used correctly and in compliance with the instructions. The guarantee becomes null and void in the event of the following: unauthorized attempts to repair the appliance; unauthorized technical changes to the appliance; use of non-original spare parts; manhandling; inappropriate use, e.g. for industrial purposes. The guarantee does not cover: parts liable to rapid wear and tear. For any action under guarantee, contact an authorized customer support service, presenting your receipt for the purchase of the product. DAB PUMPS INC 3226 Benchmark Drive, Ladson South Carolina 29456 U.S.A. Ph. 1-843-797-5002 Fax 1-843-797-3366 www.us.dabpumps.com 6

Via Marco Polo, 14 - Mestrino (PD) Italy - Phone +39.049.9048811 - Fax +39.049.9048847 Customer Technical Assistance: Phone +39.049.9048911/12/14/51 - Fax +39.049.9048920 www.dabpumps.com DAB PUMPS LTD. Units 4 & 5, Stortford Hall Industrial Park, Dunmow Road, Bishop s Stortford, Herts CM23 5GZ - UK salesuk@dwtgroup.com Tel.: +44 1279 652 776 Fax: +44 1279 657 727 DAB PUMPS B.V. Brusselstraat 150 B-1702 Groot-Bijgaarden - Belgium info.belgium@dwtgroup.com Tel.: +32 2 4668353 Fax: +32 2 4669218 DAB PUMPS INC. PUMP DIVISION 3226 Benchmark Drive Ladson, SC 29456 USA info.usa@dwtgroup.com Ph. : 1-843-824-6332 Toll Free : 1-866-896-4DAB (4322) Fax : 1-843-797-3366 OOO DWT GROUP 100 bldg. 3 Dmitrovskoe highway, 127247 Moscow - Russia info.russia@dwtgroup.com Tel.: +7 495 739 52 50 Fax: +7 495 485-3618 DWT South Africa Podium at Menlyn, 3rd Floor, Unit 3001b, 43 Ingersol Road, C/O Lois and Atterbury, Menlyn, Pretoria, 0181 P.O.Box 74531, Lynnwood Ridge, Pretoria, 0040, South-Africa info.sa@dwtgroup.com Tel +27 12 361 3997 Fax +27 12 361 3137 DAB PUMPS B.V. Albert Einsteinweg, 4 5151 DL Drunen - Nederland info.netherlands@dwtgroup.com Tel.: +31 416 387280 Fax: +31 416 387299 DAB PUMPEN DEUTSCHLAND GmbH Tackweg 11 D - 47918 Tönisvorst - Germany info.germany@dwtgroup.com Tel.: +49 2151 82136-0 Fax: +49 2151 82136-36 DAB PUMPS IBERICA S.L. Parque Empresarial San Fernando Edificio Italia Planta 1ª 28830 - San Fernando De Henares - Madrid Spain info.spain@dwtgroup.com Ph.: +34 91 6569545 Fax: +34 91 6569676 DAB PUMPS CHINA No.40 Kaituo Road, Qingdao Economic & Technological Development Zone Qingdao City, Shandong Province, China PC: 266500 info.china@dwtgroup.com Tel.: +8653286812030-6270 Fax: +8653286812210 07/13 cod. 60161964 Pumps DAB Pumps America Inc. Inc. 3226 Benchmark Drive Landson SC 29456 Phone 843-797-5002 - Fax 843-797-3366 http://us.dabpumps.com/