OSYSU Series Outside Screw and Yoke Valve Supervisory Switch

Similar documents
PCVS Series Control Valve Supervisory Switch

Materials. Contact Ratings. Conduit Entrances

Potter Electric Signal Company, LLC St. Louis, MO Tech Support: / Customer Service:

I-BFV.KIT Butterfly Valve Gear Operator Replacement

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Model RM-1 Riser Manifold Commercial and Residential General Description

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide

Series 10 Actuator. Installation, Operation and Maintenance Manual

M9216 Series Electric Spring Return Actuators

General Description. Product Specification. Document Digital Temperature Interlock

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised

VA-4233-GGx Series Electric Valve Actuators

VA-7450 Series. Electric Valve Actuators

Quarter Master Chief Series 92 Actuator

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

2006 Series Geared Rotary Limit Switches

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

Technical Data. Sizes 2 12 Inch (DN50 DN300)

VA-4233-AGx Series Electric Valve Actuators

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

Locktite Manual Reset Gas Shut-Off Valves

Worldwide Contacts. Technical Data

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

ECON Limit Switch Box Fig

Instruction Bulletin. Jockey Pump Controller

Quarter Master Series 94 Actuator

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Data Sheet. A-Series Miniature Watertight Pressure Switches

2000 Series Geared Rotary Limit Switches

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

Electric Actuators Maximum in-lbs

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

P70, P72, and P170 Controls for Low Pressure Applications

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Safety switches for hinges

RETRO SOLUTIONS PRODUCT CATALOG

PRODUCT INFORMATION BULLETIN

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Electric Actuators Maximum in-lbs

SKD62UA Series Electronic Valve Actuator, Advanced Features

M9206-GGx-2S Series Proportional Electric Spring Return Actuators

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

the Interactive Catalog

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

How to Select the RE Industrial Actuator Part Number

Photo 1. Shift pattern gate plate

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

GE Sensing & Inspection Technologies

3SE03 North American Limit Switches

Fire Protection Indicator Post

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe

SAFE & SECURE ACTUATOR PRODUCT MANUAL

CVR-625. Compact Vibrating Rod Instruction Manual

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

AccuPower AQU126B Installation Instructions

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Effective December 2015 Supersedes September 2013

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

the Interactive Catalog

SAX Electronic Valve Actuator

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

RETRO SOLUTIONS PRODUCT CATALOG

Powers TM Controls EA 338 Electronic Actuator

Installation, Operation & Maintenance Manual

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

Safety rope switch without reset for simple stop

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

AccuPower AQU128B Installation Instructions

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

MF4E MF4E

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

SAX Electronic Valve Actuator

Installation Instructions Street Bandit Shifter

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Switches. Common Used Terminology:

Switches with manual reset

Transcription:

Features NEMA 4X* (IP 65) and 6P (IP 67) *Enclosure is 4X. For additional corrosion protection of mounting hardware, use model OSYSU-2 CRH -40º to 140º (-40ºC to 60ºC) operating temperature range Visual switch indicators Two conduit entrances Adjustable length trip rod Accomodates up to 12AWG wire Three position switch detects tampering and valve closure Knurled mounting bracket prevents slipping Fine adjustment feature for fast, easy installation RoHS compliant One or two SPDT contact models (-1,-2) Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. Important: This document contains important information on the installation and operation of OS&Y valve supervisory switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS&Y valves ranging in size from 2 to 12 (50mm to 300mm). They will mount on some valves as small as ½ (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device. Testing The operation of the OSYSU and its associated protective monitoring system shall be inspected, tested, and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Jurisdiction (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve wheel towards the closed position. The OSYSU shall operate within the first two revolutions of the wheel. Fully close the valve and ensure that the OSYSU does not restore. Fully open the valve and ensure that the OSYSU restores to normal only when the valve is fully opened. Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in a false valve open indication. Technical Specifications Dimensions See Fig 8 Weight 1.6 lbs (0,73 kg) Cover: Die Cast Finish: Red Powder Coat Enclosure Base: Die Cast Finish: Black Powder Coat All parts have corrosion resistant finishes Tamper Resistant Screws Cover Tamper Optional Cover Tamper Switch Available OSYSU-1: One Set of SPDT (Form C) OSYSU-2: Two Sets of SPDT (Form C) Contact 10.0 Amps at 125/250 VAC Ratings 2.0 Amps at 30VDC Resistive 10 mamps minimum at 24 VDC -40º F to 140ºF (-40ºC to 60ºC) Environmental Limitations Conduit Entrances NEMA 4X (IP 65) and NEMA 6P (IP 67) Enclosure (Use suitably rated conduit and connector) Indoor or Outdoor Use (See OSYSU-EX Bulletin 5400705 for Hazardous locations) Two Knockouts for 1/2 conduit provided (See Notice on Page 6) Service Use NFPA 13, 13D, 13R, 72 Specifications subject to change without notice 5401525 - REV D 1/15 PAGE 1 OF 6

Theory of Operation The OSYSU is a 3 position switch. The center position is the normal installation position. Normal is when the switch is installed on the OS&Y valve, the valve is fully open and the trip rod of the OSYSU is in the groove of the valve stem. Closing the valve causes the trip rod to ride up out of the groove and activates the switches. Removing the OSYSU from the valve causes the spring to pull the trip rod in the other direction and activates the switches. Visual Switch Status Indication There are 3 visual indicators to determine the status of the switches. Fig 1; the actuator button of the micro switches are on the raised section of the switch actuator. Fig 2; the trip rod is perpendicular to the base and lined up with the alignment mark on the mounting bracket. Fig 3; the white visual indicator is visible through the window on the back of the switch actuator. A final test is to meter the contacts marked COM and N.O. to ensure they are an open circuit when the valve is open and that they close and have continuity within 2 revolutions of turning the valve handwheel towards the closed position and the contacts remain closed as the valve is completely closed and until the valve is completely opened when the trip rod drops back into the groove in the valve stem. Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Trip Rod Locking Screw Micro-Adjustment Feature 5401525 - REV D 1/15 PAGE 2 OF 6

Fig 6 Small Valve Installation - 1/2 Through 2 1/2 Sizes Slotted mounting holes and micro-adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Small Valve Installation NOTE: If the valve stem is pre-grooved at 1/8 minimum depth; proceed to step 7. 1. Remove and discard "E" ring and roller from the trip rod. 2. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far from the valve gland so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 6 if possible to avoid creating a pinch point between the wheel and the OSYSU. 3. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 9). Reinstall trip rod and repeat Step 3 procedure. 4. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. 5. Mark the valve stem at the center of the trip rod. 6. Remove the OSYSU. Utilizing a 3/16 or 1/4 diameter straight file, file a 1/8 minimum depth groove centered on the mark on the valve stem. Deburr and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16 can make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. 7. Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 6, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2, to aid in initially locating the OSYSU. 8. Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. 9. Tighten the adjustment screws and all mounting hardware securely (20 in-lbs minimum). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. 10. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in a false valve open indication. Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 5401525 - REV D 1/15 PAGE 3 OF 6

Fig 7 Large Valve Installation - 3 Through 12 Sizes Slotted mounting holes and microadjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Large Valve Installation NOTE: If the valve stem is pre-grooved at 1/8 minimum depth; proceed to step 6. 1. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far from the valve gland so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 7 if possible to avoid creating a pinch point between the wheel and the OSYSU. 2. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. 3. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 9). Reinstall trip rod and repeat Step 3 procedure. 4. Mark the valve stem at the center of the trip rod. 5. Remove the OSYSU. Utilizing a 3/8 or ½ diameter straight file, file a 1/8 minimum depth groove centered on the mark on the valve stem. Deburr and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16 can make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. 6. Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 7, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2, to aid in initially locating the OSYSU. 7. Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. 8. Tighten the adjustment screws and mounting hardware securely (minimum 20 in-lbs). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. 9. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in a false valve open indication. 5401525 - REV D 1/15 PAGE 4 OF 6

8 7 6 5 4 F Fig 8 6.19 157.23 Dimensions 6.19 157.23 4.00 101.60 4.00 101.60 3.20 81.26 3.05 77.47 2.25 57.13 3.20 81.26 E 2.79 70.87 2.79 70.87 5.69 144.42 5.69 144.42 5 4 3 2 1 D Rod retracted and breakaway section removed 1.17 29.72 1.17 29.72 C 3.67 93.26 3.05 77.47 2.25 57.13 3.67 93.26 Rod fully extended Cover Tamper Switch (Optional) 2.10 53.34 (2) ø.886 Knockouts For 1/2 Electrical Conduit Connections Cover Removed B Ground Screw.XX = ENGLISH [XX.XX] = METRIC DIMENSIONS APPEARING IN PARENTHESIS [ ] REPRESENTS EQUVALENT IN MILLIMETERS ALL DIMENSIONS FOR REFERENCE ONLY A 1/4-20 Mounting Hardware 2.10 53.34 8 7 Clamp Bar 6 Trip Rod 5 4 NS Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 5401525 - REV D 1/15 PAGE 5 OF 6

Breaking Excessive Rod Length Fig 9 Switch Terminal Connections Clamping Plate Terminal Fig 10 Incoming Outgoing Ordering Information Model Description Stock No. OSYSU-1 Outside Screw & Yoke 1010102 (Single switch) OSYSU-2 Outside Screw & Yoke (Double switch) 1010202 OSYSU-2 CRH Outside Screw & Yoke Supervisory 1010210 Switch (Double Switch). Corrosion resistant hardware of 316 stainless steel & nickel plated to ASTM B377 Type V Brackets Cover Screw 5490424 Hex Key for Cover Screws and 5250062 Installation Adjustments Optional Cover Tamper Switch Kit 0090200 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. All conduit and connectors selected for the installation of this product shall be suitable for the environment for which it is to be used and shall be installed to the manufacturer s installation instructions. For NEMA 4, 4X, 6, 6P installations, the cover screws are recommended to be tightened to 15 inlbs minimum and the trip rod locking screw tightened to 5 in-lbs minimum to properly seal the enclosure. Typical Electrical Connections Fig 11 EOLR COM NC NO NO NC COM Engineering Specifications: OS&Y Valves UL, CUL Listed / FM Approved and CE Marked valve supervisory switches shall be furnished and installed on all OS&Y type valves that can be used to shut off the flow of water to any portion of the fire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The supervisory switch shall be NEMA 4X and 6P rated and capable of being mounted in any position indoors or out and be completely submerged without allowing water to enter the enclosure.. The enclosure shall be held captive by tamper resistant screws. The device shall contain two ½ conduit entrances and one or two Single Pole Double Throw (SPDT) switches. There shall be a visual indicator to display the status of the switches. To aid in installation, it shall be possible to make fine adjustments to the position of the switch on the valve without loosening the mounting bracket from the valve. The device shall contain an adjustable length trip rod and roller, the trip rod shall be held captive by a set screw accessible upon removal of the cover. The switch contacts shall be rated at 10A, 125/250VAC and 2A, 30VDC. OS&Y Valve supervisory switch shall be model OSYSU-1 for the single switch model and OSYSU-2 for the two switch model manufactured by Potter Electric Signal Company LLC TO FIRE ALARM PANEL 5401525 - REV D 1/15 PAGE 6 OF 6