Comfy Dry Bath Incubator

Similar documents
Operation Manual. H6000 Series

Semi-automatic Thermal Sealer

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Model : LMHS-40 Please read this manual carefully before using the instrument Labnics Equipment

XK3190- A7. Weighing indicator USER MANUAL

Weighing Scale IDS-802. User Manual

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

MyGel Mini. Operating Manual Version 1.2. a division of. Electrophoresis System. 6 Troubleshooting (continued) Problem Causes Resolutions

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

BRAKE TESTER DECELEROMETER

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

Inline Ultrasonic Flowmeter

DRY BATH INCUBATOR (HEATING BLOCKS) Model: DB-005, DB-006, DB-006E

INSTRUCTIONS MANUAL CLAM BALL / CLAM CAP

Melting Point Device DMP100 OPERATING MANUAL VERSION 1.11

Dip Tester Model DS-03

LCD Centrifuge MDCEN-302

AHC Controller Operation Manual

Please confirm the motor & capacitor products to be well aware of knowledge of the

ST Wiring diagram. Product description. Temperature controller. Order number

POWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE

TCS 1200 Portable Temperature Calibrator

High-performance Dry Bath-Heating... P. 57~58 High-performance Dry Bath-Heating & Cooling... P. 59~60

Model : LHT-002A Please read this manual carefully before using the instrument Labnics Equipment

Manual Kinematic Viscosity Bath Tamson TV12

Safety design conforming to the following provisions

TABLE OF CONTENTS. Introduction

Model 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES

The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

UP100AC INSTRUCTION MANUAL

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Weighing System CALIBRATOR ZURF

User manual. e-gate SLD-24V

Wheel Products. WP8300 Operators Manual Rev: 910

DIGITAL TORQUE GAUGE MODEL BTGE-G

EC20 Pocket Conductivity Tester Instruction Manual

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

Operating Instructions CHARGERY C650. Microprocessor controlled high performance rapid charger for LiPo battery packs with cell balancer.

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Operation Manual For NDJ-9S Digital Rotary Viscometer

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Mixer/Temperature Control

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

OPERATING INSTRUCTIONS. Models SI-1400 through SI-1406

MLP2 - DUAL-BRANCH LUBRICATION SYSTEM

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

Thermistor Thermometer MODEL NO

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00

BMS8. Thanks for your purchasing the intelligent BMS8. Read the ENTIRE instruction manual to become familiar with the features/functions of the device

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

Lift-N-Glide Manual. Lifter Serial Number: Lift Mast Serial Number: Intermediate Member Serial No:

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Operating Instructions 680B. 8A 6CELLs 150W. 1 to 6 LiPo and LiFe batteries Balance charger. Chargery Power Co., Ltd.

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

DIGITAL TORQUE WRENCH. Useful Instructions

PV Generation System. Solar Charge Controller SPECIFICATION

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

BlueSpin Cryo. (Cat. No. BSD-CRYO)

Harris IRT Enterprises Digital Resistance Tester Model XP

DOUBLE WAYS THERMOCOUPLE METER. Users Manual

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Problems with your 12V Booster?

AT8020. Breath Alcohol Tester. Using manual. Ver:HW

OVERVIEW OF CONTROLS

Operating Instructions CHARGERY 680B

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

Dissolved Oxygen Measurement System with Air Blast Cleaner

V1.0. Showven Technologies Co.,Ltd.

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Techcon Systems TS6500 CIM Automatic Techkit Mixer

END OF YEAR WAREHOUSE CLEARANCE SALE! Ex Demo & Superseded Instrumentation

Uninterruptible Power System

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

Salt 1 Pocket Salinity Tester Instruction Manual

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

Operating Instructions BPH 35W CHARGER

Portable Surge Protective Device Tester SPD T8 tester User Manual

MODEL 3567A. Digital MΩ Tester. Instruction Manual

Providing a constant temperature control and high cooling efficiency.

NOTES TABLE OF CONTENTS

OFI MODEL 130 HTHP BENCHTOP CONSISTOMETER INSTRUCTIONAL MANUAL

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

INTRODUCTION. Specifications. Operating voltage range:

11 Thermoshakers. Thermoshaker with cooling. Thermoshaker. Thermoshaker for microplates. PCMT for microtubes and microplates

Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

Transcription:

Comfy Dry Bath Incubator Operation Manual www.avansbio.com

PREFACE Thanks for choosing Comfy Dry Bath Incubator. This operation manual describes functions of the instrument. To ensure that you could operate the instrument in a correct way, please read the manual carefully before using it. PACKING LIST serial description type quantity 1 Instrument CDBI-24 1 set 2 Power Adapter DC24V/120W 1 piece OUT OF BOX AUDIT At the first time of opening the packing, please check the instrument and appendix with the packing list. If anything does not match with the packing list, please contact with the supplier. 3 Operation Manual 1 piece 4 Warranty Card 1 piece 12

Appendix 1 Wiring Diagram of Comfy Dry Bath Incubator 100-240V~ CONTENTS 1. Introduction...1 1.1 Instrument Content..1 1.2 Structure...2 1.3 Installation....3 Power Adapter 24V 120W Power Switch 2. Specification...4 3. Safety Warning.....5 4. Operation Guide...6 4.1 Key Function...6 4.2 Programming......6 J7 J4 4.3 Time Unit Changing.6 4.4 Program Start and Stop.....7 Sensor J5 Controller J3 Heater 4.5 Temperature Calibration...8 5. Maintenance 10 J1 J2 6. Failure Analysis and Trouble Shooting...10 Appendix 1 Wiring Diagram of Comfy Dry Bath. 11 Display Panel Key Board Packing List..12 11

1 Introduction Comfy Dry Bath Incubator is best designed instrument which is microprocessor-controlled. It is widespread used for samples of the preservation and reaction, DNA amplification, foreseeability of electrophoresis and so on. Please do read this operation manual carefully before using the instrument. 5 Maintenance Please make periodic cleaning for wells in block and the surface of the instrument with alcohol mull. Power off before cleaning the instrument. It is forbidden to decant cleaning fluid into the well of block. 6 Failure Analysis and Trouble Shooting Phenomenon Possible Causes Processing Procedure 1.1 Instrument Content Comfy Dry Bath Incubator Power Adapter Operation Manual Certificate of Quality 1 set 1 piece 1 piece 1piece No Signals on the display when power on open1 or open2 in the temperature display with the alarm of beep No power Broken switch Broken Controller open1 : block temperature open2 : lid temperature Check the power Exchange the switch Contact with the seller Contact with the seller short1 or short2 in the temperature display with the alarm of beep short1 : block short2 : lid Contact with the seller err1 or err2 in the temperature display with the alarm of beep err1 : block err2 : lid sensor is broken Contact with the seller Press invalid Broken film switch Contact with the seller 1 10

4.5.3 Press and simultaneously under no operating status. The program turns to the right interface. The program auto controls temp. to 40 C, the sign flickers ceaselessly. When it achieves 40 C, cursor arises under decimal, Adj and flicker ceaselessly together. 4.5.4 After 20 minutes, the temperature value of thermometer is 38.8 C, press or to amend the display value to 38.8. Press Start to confirm. Program saves the value and temperature rises to 100 C automatically. The sign flickers ceaselessly. 40.0 Adj 38.8 Adj Press start 1.2 Structure Block Display Panel Keyboard 4.5.5 When temperature achieves 100 C, cursor arises under decimal, Adj and flicker ceaselessly together. 4.5.6 After 20 minutes, the temperature value of thermometer is 99.0 C, press or to amend the display value to 99.0. Press Start to confirm. 100.0 Adj 99.0 Adj 4.5.7 Program turns to interface for operating as the right chart. P1 94.5 XX After temperature calibration, the temperature display is the same as the practical temperature of block. NOTICE: Press start To ensure temperature accuracy, keep the temperature 20 minutes when it achieves adjusted temperature. During temperature calibration, press and simultaneously to cancel the calibration. The system keeps the former calibration. Do not press and simultaneously unless necessary. Power Connector Power Switch 9 2

4.5 Temperature Calibration 1.3 Installation 1.3.1 Put the instrument on the working table steady. 1.3.2 Connect power and instrument through the power adapter. Power voltage should during 100-240V~ 1.3.3 Turn on the power switch on the right side. The incubator runs the program to the set temperature automatically. 1.3.4 When it achieves the set temperature, put the tubes into the block, close the thermo lid. DC 24V 100-240V~ If there is deviation between the actual temperature and the display temperature due to some reasons, you can do as follows to calibrate it. Notice: The instrument uses two temperature adjustments to ensure its accuracy. It is linearly adjusted on 40 C, and 100 C. The temperature precision will be within ± 0.5 C after the double temperature adjustments. Both the environmental and the block temperature should be lower than 35 C when calibration. The temperature of the instrument has been adjusted well in the factory. Please do seriously consider before you use this function. Adjustment Methods: 4.5.1 Start up the instrument, it enters waiting interface. 4.5.2 Inject olefin oil into one of the cone-shaped wells. Put a thermometer into this well (the precision of the thermometer should be 0.1. The temperature ball should be absolutely immerged into the cone-shaped well). Heat insulation material is needed on the block to separate it from the circumstance. Refer to Figure A Thermometer Tube Adiabatic Board Olefin Oil Block Well 3 Figure A 8

4.4 Program Start and Stop 4.4.1 Press PROG., nine preset programs P1,P2,P3,P4,P5,P6,P7,P8, P9 could be selected. 4.4.2 When power on, the temperature rises to set temperature of segment 1 automatically. It displays Going when heating; it displays OK when it achieves the set temperature. P2 35.5 C Going P2 37.0 C OK 4.4.3 Press START to run the segment 1. which indicates segment 1 flickers. When segment 1 finishes, the program starts segment 2. which indicates segment 2 flickers, and it begins to count down. P2 37.0 020min P2 45.0 020min 2 Specification Model Power Input Maximum Power Comfy Dry Bath Incubator DC24V 120 W Temperature Range -10-100 Timing Range 1min - 999min or 1sec - 999 sec Temp. Control Accuracy ± 0.5 Display Accuracy 0.1 4.4.4 Buzzer alarm when it counts to 0 at segment 2. PROGRAM END displays on LCD. The incubator keeps the temperature of segment 2. Heating Time (from 20 to 100 ) 15min PROGRAM END Press any key to return P2 43.3 Going. Ambient Temperature 5 ~ 35 Dimension(W D H) 110mm 156mm 100mm Net Weight 1.4Kg Press any key to return to the operating interface. It turns to the set temperature of the current segment. When it achieves, OK is displayed on LCD. Press START to run the program again. 4.4.5 Press START/STOP continuously for 1 second, program stops, timing ends. 7 4

3 Safety Warning The incubator is a normal and an indoor using instrument. Read operation manual carefully before operation. Only the expert of wiring equipment can operate this instrument. The operator should not open or repair the instrument by himself. Otherwise, the instrument will lose the qualification of repair guarantee or cause accidents. The company will repair the instrument based on warranty description. The instrument should be put in the place where of low temperature, little dust, no water, no sunshine or hard light, a nd of good aeration, no corrosively gas or strong disturbing magnetic field, and far away from central heating, camp stove and other hot resource. Do not put the instrument in wet and dusty place. Main switch is on the rear of the device. Push I to power on the device, and push O to power off the device. Power input interface is on the rear of the instrument. Power voltage input is DC24V. Input is anode, outer ring is cathode. 4. Operation Guide 4.1 Key Function START/STOP----Start or stop the operation program PROG.-------------Select operation program ----------------Set Temperature or Timing value ----------------Enter value set or move cursor 4.2 Programming Press PROG., select option program, e.g. P2. Press to enter temp setting. Press to move cursor. Press or to set timing. Two segments could be set in each program. indicates temp. or timing of segment 1. indicates temp. or timing of segment 2. P2 37.0 003min P2 45.0 006min Temp. and Timing of Segment 1 Temp. and Timing of Segment 2 4.3 Time Unit Changing Press " 2 seconds under timing setting, timing unit alternatively changes between min and sec. Timer unit : min Timer unit : sec Power off when operation finished. If long period do not use the instrument, pull off the connector plug, cover a cloth on the instrument to prevent from dust. Press to select min or sec. Press to confirm. 5 6