Part 1: Land Applications Machinery Spaces, Industrial Hazards, Combustion & Gas Turbine Enclosures, Light & Ordinary Hazards

Similar documents
GW M5 WATER MIST NOZZLE K-5, LOW PRESSURE, NON-AUTOMATIC

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

model E Spray nozzles vk810 - vk817

MEDIUM VELOCITY WATER SPRAY NOZZLE

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

TECHNICAL DATA OBSOLETE

Hong-Zeng (Bert) Yu FM Global International Water Mist Conference Barcelona, Spain November 14-15, 2012

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

Knowsley SK s turnkey solution for extinguishing fires which can occur on helipads and helidecks NESTOTM. Deck Integrated Fire Fighting System (DIFFS)

Data Sheet Issue E

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Approved for use as fixed fire extinguishing system for machinery spaces and cargo pump rooms.

Data Sheet 11.1 Issue A

VID Fire-Kill Marine and Offshore Product Catalogue Year 2015 Rev 1.

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings

Foam Ratio Controller Proportioning Devices Model KFP

Lecture 27: Principles of Burner Design

TECHNICAL DATA. Table Standard Materials

SPRAY CHARACTERISTICS Mist at low pressure; fog at high pressure Spray pattern: Cone-shaped Fog Flow rates: to l/min

Model F1 Model F1 Recessed Standard Response Sprinklers

AIR ATOMISER NOZZLES. Vapro Series. VP Body 24. VPX/VPL Body

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

Spacing and Pattern Effects on DU LQ of Spray Nozzles

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

Fire Protection Systems

Floating pumps & Strainers; Compact and durable water solutions.

Air Atomising Products Swirl-Air Nozzles. Product Guide

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

50830 Series Low Pressure Centrifugal Pump

TYPE AL AIR ATOMISING D.20

Comparative study of the flow within water mist and sprinkler fire protection systems by means of CFD

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

MEDIUM VELOCITY WATER SPRAY NOZZLE

Side Structures in Single Side Skin Bulk Carriers

TECHNICAL DATA. mixture, with a freeze temperature

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

OWNER S MANUAL REMOTE CONTROL, DUAL HEAD FOGGING SYSTEMS

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

IACS UR s and Panel Responsible

FIA & MSA Approved Systems FITTING INSTRUCTIONS PLEASE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR SYSTEM. Inst/Z2000/All/V1/Oct05 1

HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)) APRIL 2008

In-Line Balanced Pressure Proportioner (ILBP) Proportioning Devices Model KBP

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Technical Bulletin 012 Zero 2000 MSA & FIA Kit Content and Spares

Extent of Delivery. Extent of Delivery / Order Specifications W-X82-B & W-X92 Engines. Instructions. All quantities to be stated for one vessel

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

Schlick PCA - Professional Coating Arm

VR2-CC VR2-RS VR2-ES PRODUCT MANUAL

Important design parameters and user-friendly features of modern air mist nozzles for slaband beam blank casters

PART 8 MACHINERY INSTALLATIONS

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

World s Smallest SO X Removal Cyclone Scrubber for Marine Vessels

AIR LUBRICATION SYSTEM INSTALLATION

Extent of Delivery. W-X35-B/40-B Engines. Extent of Delivery / Order Specifications. Instructions. All quantities to be stated for one vessel

ADVANCED FIRE SUPPRESSION TECHNOLOGIES STORED AFFF BULK SYSTEM 150/250/350

Task By Course 7.1D This task is covered for engineers in the Leadership and Managerial Skills course

BS 2,7-6,7. Steel Containers with Differential Pressure Valve for the CLEAN AGENT FS 49 C2 Extinguishing Agent. Optional

VisiFlo Hollow Cone Spray Tips

Danish Fire Laboratories ApS

Recommendation for petroleum fuel treatment systems for marine diesel engines

Essentials of Fire Fighting

Oily Water Separators. globally focused on cleaner solutions

Nozzle Features. For advice on nozzle choice please call +44 (0) or

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

Nessie Water Mist Nozzles

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

HAZARDOUS AREA CLASSIFICATION (APPLICATION OF SOLAS REGULATION II-1/45.11)

Data Sheet 11.2 Issue B

Fixed or Semi-Fixed Foam Fire Protection Systems for Storage Tanks

AIR-OIL injector BLOCK. Oil Streak Generating, Mixing and PDI systems

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

UNI-SPRAY - CLAMP-ON NOZZLE SELECTION GUIDE -

2ND EXAM OF MAIN MACHINERY AND AUXILIARY MARINE SYSTEMS

Darley Fire Storm Nozzle

HIGH EFFICIENCY VERTICAL MACHINING CENTER

2015 Product Catalog - Test Equipment for ASTM: E-1105, E-2128 and AAMA: 501.2, 502, 503, 511

LIQUEFIED PETROLEUM GASES

FESG1500R Remote Electronic Plumbed-In Fire Extinguisher System Installation Instructions

Political Forum. ClassNK s perspective on regulatory developments Low sulphur fuels & Ship digitalization

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

Pro-Spray. A rugged contractorfriendly. for residential and commercial projects

5. Combustion of liquid fuels. 5.1 Atomization of fuel

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

GUIDELINES FOR THE MAINTENANCE AND INSPECTIONS OF FIXED CARBON DIOXIDE FIRE-EXTINGUISHING SYSTEMS

IACS UR s and Panel Responsible

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

ABC DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS

PSI SEALING PLUGS PRESSURE TIGHT UP TO 3 BAR HORIZONTAL AND VERTICAL MOUNTING POSITION FIVE RUBBER QUALITIES FOR DIFFERENT APPLICATIONS

Cargo Handling Sheet. Styrene. Document date: 21 November 2013 Revision 5

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

MODELS F822 THRU F834

Water distribution tests using different water spray nozzles

Corrosion, Inspection and Maintenance of Oil Tankers

4000 Series TAG2A Diesel Engine ElectropaK rpm net standby power

CORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT

Transcription:

Nozzle Design Layout Part 1: Land Applications Machinery Spaces, Industrial Hazards, Combustion & Gas Turbine Enclosures, Light & Ordinary Hazards Fogex Nozzles Fogex water mist nozzles are selected for a risk area having regard to the fire hazards requiring protection and dimension criteria of the risk area. The water fog nozzles are positioned to provide uninterrupted water fog momentum, maximum spray coverage and impingement. Fogex nozzles are supplied with in-built 316 grade stainless steel filters to prevent blockage. Data Sheet Fogex nozzles are manufactured of high quality aluminium bronze. Stainless steel nozzles are also available. The nozzles are fully serviceable and interchangeable. They are engineered to yield optimal flow rates, water spray flux densities, spray patterns and spray momentum. Fogex nozzles do not have any moving or rotating parts that may malfunction and are therefore extremely reliable, efficient, manufactured of high quality materials and are corrosion resistant. Fogex nozzles produce a very fine atomised water mist (or fog) pattern encompassing a Class 1 water mist. They have been environmental tested in accordance with IMO Guidelines MSC/Circ. 668/728 Test Protocols by Factory Mutual (USA), project identifier No. 3007879, Class 5560. Fogex for Land Applications: FMRC Design Pressure K-Factor Nozzle Coverage (m²) FOGEX F20 100 Bar 6.4 0.64 L/min/bar ½ 17 FOGEX F27 100 Bar 5.3 0.53 L/min/bar ½ 17 FOGEX F11 100 Bar 10.0 1.00 L/min/bar ½ 17 FA automatic nozzles have the same respective flow as their open deluge counterparts. Nozzle Spacings Land Applications: Nozzle Spacings Nozzle Heights FOGEX F20 3 x 4 6.4 5.0 FOGEX F27 3 x 4 5.3 5.0 FOGEX F11 4 x 4 10.0 11.1 FOGEX FA20 3 x 4 6.4 5.0 FOGEX FA27 3 x 4 5.3 5.0 FOGEX FA11 4 x 4 10.0 11.1 Nozzle Spacings and Location The maximum horizontal spacing between nozzles is as per listings and/or manufacturer specifications. The nozzle spacings and ceiling heights should not be exceeded by more than 15% of their listed designs. Room hazard geometries are rarely symmetrical and a very small discretion in nozzle spacings is permitted, however, the Authority Having Jurisdiction (AHJ) and/or the manufacturer must be consulted first where it is anticipated that nozzle spacings may slightly exceed their Listing requirements. Assessed to ISO 9001: 2000 Certificate number 018 e-mail info@watermistftl.co.uk web www.watermistftl.co.uk tel 0845 453 1320 fax 01525 285864 Water Mist Fire Technologies Ltd Unit 5, Youngs Industrial Estate Stanbridge Road, Leighton Buzzard Bedfordshire, LU7 4QB

Total Flooding Applications: Fogex F20 & 27 nozzles are used for Total Flooding applications in land applications under NFPA 750 Standards and product approval Listings. The maximum grid spacing is 3 metres by four metres (3m x 4m). The maximum ceiling height for the Fogex F20 & F27 nozzles is 5.0 metres. Fogex F20 multiple orifice full cone nozzles have a 35º spray angle to provide adequate spray coverage and penetration from a 5.0 metre ceiling height. Each Fogex F20 multi-orifice full cone spray nozzle provides an area of coverage of approximately 17 square metres of space at optimal spray pattern and flux density. The minimum system operating pressure for land installations as per product Listings is 100 bars. Door Screen Nozzles: The Fogex F27 nozzles are door screen nozzles. They may be installed at ceiling level two metres apart and one metre away from and above door openings. The Fogex F27 nozzles are used to screen the oxygen from entering into the fire hazard areas. Installing Fogex F27 nozzles is an optional requirement and should be considered after a risk analysis of the fire hazard enclosure has been conducted. However, where large open access ways are encountered exceeding 4.0m² in opening, then Fogex F27 door screen nozzles must be installed to screen-off any possible free oxygen from entering the fire hazard enclosure. Generally, for doorways up to 1.0m wide, one Fogex F27 nozzle shall be installed; for doorway openings up to 2.0m width, two Fogex F27 nozzles are installed and so on. Local Applications: For Local Application systems on land Fogex F11 nozzles may be used. The maximum nozzle grid spacing is four metres by four metres (4m x 4m). The minimum distance to a fire source is 2.0 metres and the maximum distance to a fire source is 10.1 metres. Design and installation of Fogex systems on land is in accordance with NFPA 750 Standards. The uniquely designed Fogex F11 water mist nozzle has two orifice spray angles, ie one at 35º and another at 50º. This affords maximum spray pattern coverage and affords exceptional water droplet spray momentum to reach the seat of a fire to cause rapid fire extinguishment. The minimum system operating pressure for Fogex F11 nozzles for use in Local Application systems is 100 bars. The Fogex F11 nozzles may be installed on the ceiling at 11.1 metres maximum height above the floor; or they can be installed on bulk-heads, on perimeter walls or on pipe support frames etc in either a vertical or horizontal direction, or at 45º where nozzles are mounted onto walls or supporting brackets positioned on floors around an object requiring protection. General Installation Requirements: The distance of nozzles from walls or bulk heads should not exceed one-half of the allowable distance between nozzles (maximum discrepancy should not exceed 15% depending on room symmetry). The distance of nozzles below the deck is in accordance with the listing and manufacturer specifications. Where nozzles are fitted on branch lines, or between lines that run up and down pitched or curved surfaces, the nozzles are installed in accordance with the manufacturer specifications. Wherever practicable, Fogex plumbing should be a closed loop design with no end of lines. For advice on nozzle location, please contact your nearest Fogex agent or manufacturer for assistance. The Fogex water fog system is designed and installed to achieve complete mist distribution within the fire risk area. This is achieved by simultaneous operation of all open type nozzles in the fire risk area, or fire zone, by manual or automatic means. Where possible, Fogex nozzles are usually installed always on the ceiling of fire hazard enclosures. Wall mounted nozzles may be used for specific applications however the manufacturer and/or the Authority Having Jurisdiction (AHJ) must be consulted first. Page 2 Watermist Fire Technologies

Land Applications: For installation and use in machinery spaces & cargo pump rooms, industrial hazards, combustion and gas turbine enclosures and other light and ordinary hazards on land the Fogex system minimum operating pressure is 100 bars. The Fogex system offers protection against all Class A and Class B (hydrocarbon fuel) fires including hydrocarbon fuels with the severity of concealed n-heptane pan fires and flowing or spraying Diesel, oil or n-heptane fires. In combustion & gas turbine applications, Fogex F20 & F27 nozzles are not installed in such a way to cause a direct hard impingement onto hot turbine surfaces. Careful nozzle installation will ensure that adequate fog distribution throughout the combustion or gas turbine enclosure will be achieved without excessive fog impacting upon hot turbine components. This is to ensure that metallic turbine components may not become damaged to rapid surface cooling during fog discharge. Fogex F20 & F27 nozzles can be placed on opposite ends of a combustion or gas turbine enclosure on the walls so that the spray momentum is diagonally opposing to each other during system activation. This will cause a rotational fog flow within the enclosure and prevent direct impingement onto hot turbine surfaces. Ceiling mounted nozzles can also be used simultaneously in addition to wall mounted nozzles to create a total flooding fog fire protection system. In all other land applications analogous to Local Application systems where machinery spaces and industrial hazards are encountered (where specific Classification Society approvals are not required), Fogex F11 open type water mist nozzles may be used when ceiling heights are in excess of 5.0 metres. This recommendation by the manufacturer is provided based on fire testing conducted at VTT Laboratories for Local Application systems under IMO Guidelines MSC/Circ. 913 test protocols. Fogex F11 nozzles have been tested and the minimum distance from a fire source to the nozzle is 2.0 metres and the maximum distance from a fire source to a nozzle is 10.1 metres. For installation design purposes, nozzles can be placed 3.0 metres above floor level and up to 11.1 metres above floor level using a minimum system operating pressure of 100 bars. Fogex F11 nozzles can be installed either in a vertical pendant or horizontal pendant position to cover these hazards, or a combination of both, eg ceiling mounted and wall mounted. Nozzles installed in a 45º position may be allowed provided that the manufacturer and/or the AHJ is contacted first. Nozzles Spares It is recommended that spare Fogex nozzles be carried as part of emergency inventory for maintenance purposes. Generally, five (5%) percent is a suitable number of spare nozzles and is accepted throughout industry as standard practice. For example, a system which has 20 water fog nozzles installed, one (1) nozzle should be carried as spare. For a system with 50 nozzles installed, three (3) nozzles are carried as spare, and so on. Water Mist Fire Technologies Page 3

Part 2: Marine Applications Machinery Spaces, Cargo Pump Rooms & Local Applications Fogex Nozzles Fogex water mist nozzles are selected for a risk area having regard to the fire hazards requiring protection and dimension criteria of the risk area. The water fog nozzles are positioned to provide uninterrupted water fog momentum, maximum spray coverage and impingement. Fogex nozzles are supplied with in-built 316 grade stainless steel filters to prevent blockage. Fogex nozzles are manufactured of high quality aluminium bronze. The nozzles are fully serviceable and interchangeable. They are engineered to yield optimal flow rates, water spray flux densities, spray patterns and spray momentum. Fogex nozzles do not have any moving or rotating parts that may malfunction and are therefore extremely reliable, efficient, manufactured of high quality materials and are corrosion resistant. Fogex nozzles produce a very fine atomised water mist (or fog) pattern encompassing a Class 1 water mist. They have been environmental tested in accordance with IMO MSC/Circ. 668/728 Test Protocols by Factory Mutual Approvals in the USA, project identifier No. 3007879, Class 5560. Fogex for Marine Applications Total Flooding & Local Application: IMO Design Pressure K-Factor Nozzle Coverage (m²) FOGEX F20 110 Bar 6.4 0.64 L/min/bar ½ 17 FOGEX F27 110 Bar 5.3 0.53 L/min/bar ½ 17 FOGEX F11 100 Bar 10.0 1.00 L/min/bar ½ 17 Nozzle Spacings Marine Applications: Nozzle Spacings L/min @ 100 bar Nozzle Heights FOGEX F20 3 x 4 6.4 5.0 FOGEX F27 3 x 4 5.3 5.0 FOGEX F11 4 x 4 10.0 11.1 Nozzle Spacings and Location The maximum horizontal spacing between nozzles is as per listings and manufacturer specifications. The nozzle spacings and ceiling heights should not be exceeded by more than 15% of their listed designs. Room hazard geometries are rarely symmetrical and a very small discretion in nozzle spacings is permitted, however, the manufacturer and/or the Authority Having Jurisdiction (AHJ) must be consulted first where it is anticipated that nozzle spacings may exceed slightly their Listing requirements. Total Flooding Applications: Fogex F20 & 27 nozzles are used for Total Flooding applications in marine applications under IMO MSC/Circ. 668/728 Regulations. The maximum grid spacing is 3 metres by four metres (3m x 4m). The maximum ceiling height for the Fogex F20 & F27 nozzles is 5.0 metres. Fogex F20 multiple orifice full cone nozzles have a 35º spray angle to provide adequate spray coverage and penetration from a 5.0 metre ceiling height. Each Fogex F20 multi-orifice full cone spray nozzle provides an area of coverage of approximately 17 square metres of space at optimal spray pattern and flux density. The minimum system operating pressure for marine installations as per IMO Regulations is 1600psi (110 bars). Page 4 Watermist Fire Technologies

Door Screen Nozzles: The Fogex F27 nozzles are door screen nozzles. They may be installed at ceiling level two metres apart and one metre away from and above door openings. The Fogex F27 nozzles are used to screen the oxygen from entering into the fire hazard areas. Installing Fogex F27 nozzles is an optional requirement and should be considered after a risk analysis of the fire hazard enclosure has been conducted. However, where large open access ways are encountered exceeding 4.0m² in opening, then Fogex F27 door screen nozzles must be installed to screen-off any possible free oxygen from entering the fire hazard enclosure. Local Application: For Local Application systems on board marine vessels under the IMO Regulations, Fogex F11 nozzles are used. The maximum nozzle grid spacing is four metres by four metres (4m x 4m). The minimum distance to a fire source is 2.0 metres and the maximum distance to a fire source is 10.1 metres. The uniquely designed Fogex F11 water mist nozzle has two orifice spray angles, ie one at 35º and another at 50º. This affords maximum spray pattern coverage and affords exceptional water droplet spray momentum to reach the seat of a fire to cause rapid fire extinguishment. The minimum system operating pressure for Fogex F11 nozzles for use in Local Application systems under IMO Regulations MSC/Circ. 913 is 1450psi (100 bars). The Fogex F11 nozzles may be installed on the ceiling at 11.1 metres maximum height above the floor; or they can be installed on bulkheads, on perimeter walls or on pipe support frames etc in either a vertical or horizontal direction, or at 45º where nozzles are mounted onto walls or supporting brackets positioned on floors around an object requiring protection. General Installation Requirements: The distance of nozzles from walls or bulk heads should not exceed one-half of the allowable distance between nozzles (maximum discrepancy should not exceed 15% depending on room symmetry). The distance of nozzles below the deck is in accordance with the listing and manufacturer specifications. Where nozzles are fitted on branch lines, or between lines that run up and down pitched or curved surfaces, the nozzles are installed in accordance with the manufacturer specifications. Wherever practicable, Fogex plumbing should be a closed loop design with no end of lines. For advice on nozzle location, please contact your nearest Fogex agent or manufacturer for assistance. The Fogex water fog system is designed and installed to achieve complete mist distribution within the fire risk area. This is achieved by simultaneous operation of all open type nozzles in the fire risk area, or fire zone, by manual or automatic means. Where possible, Fogex nozzles are usually always installed on the ceiling of fire hazard enclosures. Wall mounted nozzles may be used for specific applications however the manufacturer and/or the Authority having jurisdiction must be consulted first. Nozzles Spares It is recommended that spare Fogex nozzles be carried as part of emergency inventory for maintenance purposes. Generally, five (5%) percent is a suitable number of spare nozzles and is accepted throughout industry as standard practice. For example, a system which has 20 water fog nozzles installed, one (1) nozzle should be carried as spare. For a system with 50 nozzles installed, three (3) nozzles are carried as spare, and so on. Water Mist Fire Technologies Page 5