Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Similar documents
S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

S870, S970 Series. Snap-action switches. Positive opening operation Self-cleaning contacts Catalogue D70.en

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

S880 Series Snap-action switches with positive opening operation and self-cleaning contacts Catalogue D80.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

l Snap-Action Switches

l Snap-Action Switches

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

SNAP ACTION SWITCHES type SAS-00, SAS-03

Contactors. Brochure. Contactors for industry, rolling stock and battery-powered vehicles Emergency disconnect switches

Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

Play it safe Connectors Switches Contactors. New Energy. Special Switchgear Solutions

Connect - Contact - Control. Connectors. High Power Connectors for industrial trucks Catalogue A84.en

Connectors. LV Series High Power Connectors for faster charging of industrial trucks Catalogue A84.en. more information here: schaltbau-gmbh.

Connectors. M Series Circular Modular Connectors Catalogue A10.en

Connect - Contact - Control. Fuses for high-voltage switchgear F-HS, F-VS Series Ø 60. F 185.en

FL series position switches

Position switches FD series

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Application Mini Contactors for Motors and Resistive Loads

Thermal overload relay TF65 and TF96

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Miniature microswitches - Positive break

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

Electronic overload relay EF65, EF96 and EF146

Position switches FC series

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Thermal overload relay TF140DU and TF140DU-V1000

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

General_technical_data Series

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Position switches FR series

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Safety rope switch with reset for emergency stop

SERIES MINIATURE SNAP-ACTION SWITCHES

LK Position Switches TECHNICAL DATASHEET.

Safety switches for hinges

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Application Mini Contactors for Motors and Resistive Loads

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

HL (AZH) LIMIT SWITCHES

SERIES SUBMINIATURE SNAP-ACTION SWITCHES

Safety rope switches with reset for emergency stop

Miniaturized limit switches

Pre wired limit switches

Electronic overload relays EF205 and EF370

AF40... AF96 3-pole contactors Technical data

SG-B1 SERIES / SG-A1 SERIES

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Switches with manual reset

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Play it safe Connectors Switches Contactors. Material Handling. Improved performance for rapid charging

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Technical data. Standards: IEC/EN BG-GS-ET-15

Microswitches MK series

Compact plastic limit switches with positive opening mechanism

Prewired position switches FF series

Position Switches Series 8060/2

Fuse switch disconnectors

Connect - Contact - Control. Brochure. l Connectors

Safety Limit Switch

Safety switches with separate actuator

Floor and fine adjustment switches

Position switches FR series

Magnetic Overcurrent Circuit Breaker

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Position Switches Series 8074/2

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Compact plastic limit switches with positive opening mechanism

Position Switches Series 8070/2

Single foot switches - PX and PA series

IEC Limit Switches Selection Guide

Control switch/load disconnect switch Series 8008

Datasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX

SIRIUS 3RU2 Thermal Overload Relays

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

SUB-SUBMINIATURE MICROSWITCHES - SEALED

Safety switches with separate actuator

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Microswitches M series

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

ASL09..S 3-pole Contactors - Spring Terminals

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Safety switches with solenoid and separate actuator

Thermal Overcurrent Circuit Breaker 3120-F...

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE

Safety switches for hinged doors

Safety rope switch without reset for simple stop

Thermal Overcurrent Circuit Breaker 3120-F...

Brochure Connectors. More information here: schaltbau-gmbh.com

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Transcription:

Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en

Snap-action switches, S847 Series Dual changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation S847 series snap-action switches are VDE approved and come with positive opening operation which guarantees that these switches will function even if the contacts have become welded due to a short-circuit. They have two galvanically isolated, mechanically linked contact bridges which prevent a circuit closing failure. Protected against dust, moisture and pollutants (IP40, IP60 and rated versions available) and with wiping, double-break contacts, S847 series switches stand for high reliability even at low currents and voltages. The snap-action mechanism of these switches allows extremely fast switching independent of the actuation speed, thus making them suitable for applications which are characterized by slow actuating speeds, such as limit switches for machine and door control. Features Positive opening operation: Reliable breaking of the normally closed (NC) circuit even if the contacts have become welded together, in compliance with IEC 60947-5-, Annex K. Wiping double-break contacts: Continuous low contact resistance ensures high contact reliability over the entire design life of the switch Form Z-SPDT-DB: Galvanically isolated, mechanically locked contact bridges IP rating: IP40, IP60 or in compliance with IEC 6059 (IP code) max Precision switch: High switching accuracy and resistance to shock and vibration Contact material: Silver or silver with gold plating Ag Au Switch design and function Actuator Standard: push button Auxiliary actuator: roller lever Mounting Contact area Front mount Side mount (ganging) Form Z-SPDT-DB with galvanically isolated contact bridges Positive opening operation and wiping action Contact material: Silver or silver with gold plating M screws with saddle clamp Leads, potted Flat tabs 6. x 0.8 mm Competence Applications The success of a product is owed to its quality The Schaltbau product line is clearly defined and adapted to customer needs. Behind every individual snap-action switch you will find decades of experience in engineering and manufacturing. Snap-action switches are designed with a snap mechanism that allows extremely fast switching, practically regardless of the duration of actuation. This reproduces the operating position precisely, and controls the arc more efficiently. In Schaltbau s snap-action switches the safety function is visible - with their transparent-green housing, they are known all over the world. S847 series snap-action switches are designed for use with systems and components that require a high degree of safety and reliability, such as: Safety limit switches in control circuits and systems, e.g. in NC drives, PLCs and computer controls Limit switches for machine and plant control systems Limit switches for vehicles, e.g. in door controls Specifications are subject to alteration without prior notice

Ordering code Series S847 Snap-action switch Contact configuration W Form Z-SPDT-DB IP rating 5 * A B D Contact material 8 Contacts IP40 IP60 M screws with saddle clamps Leads, potted, L = 500 mm Flat tabs 6. x 0.8 mm Silver Silver, gold-plated * Only with terminal type B: Leads, potted Example: S847 WAa B Actuator Push button Roller lever Note: Special designs, optional Return spring strengthened, B snap spring standard Magnetic blowout L Actuator styles Front mount no mounting brackets a with mounting brackets c no mounting brackets e with mounting brackets b This catalogue shows only stock items. For some variants minimum quantities apply. Please ask for the conditions. Special variant: If you need a special variant of the switch, please do not hesitate to contact us. Maybe the type of switch you are looking for is among our many special designs. If not, we can also supply customized designs. In this case minimum quantities apply. S847 WAa Sealed to IP40/00 Push button (standard) M screws with saddle clamps S847 WAe Sealed to IP40/00 Roller lever M screws with saddle clamps Parameter Identification Kennung Ausführung Versions (Kontaktraum/Anschlüsse) (contacts/terminals) IP rating (IP code to IEC 6059) IP40/00 IP60/00 /00 5 /67 Actuator styles Push button (standard), no mounting brackets a S847 WDb Sealed to IP60/00 Roller lever with brackets Flat tabs Push button, with mounting brackets c Roller lever, with mounting brackets Roller lever, no mounting brackets b e S847 WBa Sealed to /67 Push button (standard) Leads, length 500 mm Series Contact configuration Contact material Spring, return spring and plunger spring, reinforced** Magnetic blowout** M screws with saddle clamps S847 W / 8 Ag/Au Ag/Au Ag/Au Ag/Au B L A S847 WBe Sealed to /67 Roller lever Leads, length 500 mm Leads, potted Length 500 mm B Flat tabs 6. x 0.8 mm Specifications ** Special design are subject to alteration without prior notice D S847 W5Ac Sealed to /00 Push button (standard), Mounting brackets M screws with saddle clamps

4 Specifications S847 Series Standard S847 W S847 W S847 W 5 S847 W IP rating contacts IP40 IP60 or Contact configuration IEC 60947 x Form Z-SPDT-DB 4 terminals, galvanically isolated contact bridges, positive opening operation and wiping action IEC 60947 0 A at T = 85 C Conv. thermal current I th UL 508 0 A at T = 85 C IEC 60947 400 V Rated insulation voltage U i UL 508 00 V Pollution degree IEC 60947 PD UL 508 PD Rated impulse withstand voltage U imp IEC 60947 4 kv Overvoltage category IEC 60947 OV Utilization category IEC 60947 AC-5: 0 V AC /.5 A / DC-, 0 V DC /.0 A for silver contacts * UL 508 * AC 40 V /.5 A / DC 0 V /.0 A Contact gap, typ. IEC 60947 x. mm Contact force, typ. IEC 60947 0.4 N Contact resistance, typ. no leads connected IEC 60947 00 mω Positive opening force * IEC 60947 0 N Actuator travel for positive opening operations IEC 60947 see page 5 Maximum actuator travel * IEC 60947 4.9 mm Actuation speed IEC 60947 Vibration resistance 0 500 Hz all directions at 0, ms opening time Push button Roller lever Shock resistance at 0, ms opening time, half sinus Push button, roller lever EN 60068--6 EN 60068--7 50 g.0 m/s 0. mm/s min. Short-circuit protection for silver contacts * IEC 6069-0 A gr Max. operating frequency IEC 60947 00 cycles/minute 50 g 5 5 50 g 8 g 6 g 0 g Actuation force * IEC 60947.0 N.0 N Release force * IEC 60947 0. N min. 0. N min. IP rating Contacts M screws Flat tabs Leads / cables IEC 6059 IEC 6059 IEC 6059 IEC 6059 IP40 IP60 5 Mechanical endurance IEC 60947 0 million cycles 5 million cycles Temperature range IEC 60947-40 C +85 C -40 C +85 C * 4, *5 Note: Data valid for new switches under laboratory conditions and at room temperature, unless otherwise mentioned. Material Contact finish Seals Housing Leads UL/CSA Silver (AgCuF40) or silver (AgCuF40), gold-plated (Au6) Silicon, blue PC, light-green, transparent PVC insulated leads AWG 8 Mounting orientation any Weight, no magnetic blowout/leads depending on version: g... 7 g Approvals C US * Data for gold contacts upon request * Measured next to push button * General Purpose *4 Leads -0 C...+85 C *5 A slower release actuation may occur by rapidly changing air pressure Specifications are subject to alteration without prior notice

5 Dimension and circuit diagrams Dimensions S847 WAa / S847 WAa / S847 W5Aa 4KV/ >PC< Form Z-SPDT-DB: 4 terminals, galvanically isolated contact bridges, positive opening operation and wiping action Circuit diagram 4 M 4 8 5. IP40 Actuator style IP60.5 Ø4.±0.05.7... 5.5 8.85 ±0.5 9 0.5 4 5 Ganging, torque.0 Nm Front mount, torque 0.7 Nm Screwable thread length of fastening screw 4 Magnetic blowout (optional) for increased DC breaking capability 5 Free position S847 WAa / S847 WAa / S847 W5Aa S847 W Form Z-SPDT-DB S847 W Contacts IP40 / S847 W Contacts IP40 / S847 W 5 Contacts / S847 W A M screws S847 W Contact material: silver S847 W a Push button (standard) Actuator styles and positions S847 W a / S847 W c Push button (standard) Ø8 6.8 S847 W b / S847 W e Roller lever Ø8 6.8 Specifications are subject to alteration without prior notice / Dimensions in mm 9 9 Actuator position Push button (standard) a / c Actuator travel in mm Free position 8.85 ± 0.5 Operating position 6.6 ± 0.5 Release position 8.0 ± 0.5 Total positive opening travel 4. Total travel position <.9 Movement differential.4 (between operating and release position) (typical) Note: To ensure proper operation of the positive opening function it is necessary to depress the plunger to the point of total positive opening travel. However, it must not be pushed beyond total travel position. Data is valid for new switches. Actuator position Roller lever b / e Actuator travel in mm Free position 0.6 ± 0.5 Operating position 6.9 ± 0.5 Release position 9. ± 0.5 Total positive opening travel.5 Total travel position.0 min. Movement differential.4 (between operating and release position) (typical) Note: To ensure proper operation of the positive opening function it is necessary to depress the plunger to the point of total positive opening travel. However, it must not be pushed beyond total travel position. Data is valid for new switches.

6 Mounting Front mount Without mounting brackets (standard): Fastening by way of the retainer nuts (M) which are fixed in the housing of the switch. Tightening torque 0.7 Nm With mounting brackets: Mounting brackets are available for all actuator options. Tightening torque 0.9 Nm Ganging (side mount) Through the two transversal holes in the body of the switch by means of a collar screw or threaded bolt. Tightening torque.0 Nm Alternatively, DUO-Clips or retaining rings can be used.. Push button (standard) no mounting brackets a. Push button (standard) no mounting brackets a M 8±0.5 4.±0.05.5.7... 5 Screwable thread length of fastening screw 8±0.5. Push button with mounting brackets c. Roller lever no mounting brackets e.5 9 58±0.7 67±0.5.5 9 4.±0.05.5. Roller lever with mounting brackets b 8±0.5 58±0.7 67±0.5 S847 W A M screws with saddle clamps 9 Note: Screw terminals for single and multiple-wire conductors: No ferrules AWG 8... (0.75 mm²....5 mm²), with ferrules: AWG 4 (.5 mm² ) Max. conductors with the same wire gauge can be clamped per terminal Tightening torque of terminal screws should be 0.9 Nm Ingress protection rating (IP code): contacts IP40 / terminals S847 W B Leads, length 500 mm S847 W D Flat tabs 6. x 0.8 mm 0.9 6.4 ~40 9 Versions with pre-assembled leads: Terminal style: Leads AWG8 Length: 500 mm Assignment: blue 4 white black grey 4 Dimensions in mm / Specifications are subject to alteration without prior notice

7 Mounting Use of roller levers Snap-action switches are designed for actuation with and without a roller lever. A roller lever is required if the direction of actuation deviates more than ±5 from the plunger axis. Switch with roller lever actuated by cam disc Switch with roller lever actuated by linear cam Stroke 5 min. Stroke 7 40 Total travel pos. + 0.... 0. Free pos. + 0.... 0. Stroke 5 min. Stroke 7 40 40 Total travel pos. + 0.... 0. Free pos. + 0.... 0. Disc Distance 40 mm.6 mm 60 mm 0 mm 00 mm () 0 mm Mounting and safety instructions, environmental conditions Mounting instructions: Snap-action switches should be mounted by qualified professional staff only. Observe the required clearance and creepage distances. This is also applicable for connected wires. It is necessary to use insulating plates when ganging or mounting switches on uninsulated surfaces. The switches can be mounted in any orientation. When mounting the switches make sure to use fastening elements (e.g. screws). Only use adequate fastening elements such as cylinder head or collar screws or DUO-clips, including washers. When fastening make sure not to exceed the maximum tightening torque. When affixing switches with mounting brackets make sure that the mounting surface is level. Avoid tilting the screw when mounting to prevent mechanical tension on the housing. The actuator may not be pre-tensioned when in the free position. When actuated, the actuator should travel well beyond the operating position, for at least 50% of the predefined overtravel, all the way to total travel position. To ensure the proper function of the positive opening operation it is necessary to depress the plunger to the total travel position. To prevent mechanical destruction of the switch, make sure that actuation of the switch does not exceed the specified total travel position. Avoid using the switch as a mechanical end stop. High-impact actuation of the switch can have a negative effect on its mechanical life. When securing stripped wire ends in the terminal clamp, make sure the wire insulation is flush with the clamp. Prevent a transfer of forces to the switch terminals, and ensure that connected leads have a functioning strain relief. When using versions with blowout magnets observe the correct polarity, see circuit diagram on the bottom of the switch. Non-permissible environmental conditions: Cleaning agents, adhesives, solvents, or screw-retaining varnish must be compatible with polycarbonate. Never use chemicals not compatible with polycarbonate. Using such chemicals can result in cracks, deformation, breakage and dissolution of the housing or complete destruction of the respective switch. Safety instructions: Be sure to make visual inspections regularly. Improper handling of the switch, e. g. when hitting the floor with some impact, can result in breakage, visible cracks and deformation. Standards Defective parts must be replaced immediately! For a detailed list of all safety, installation and maintenance instructions see here: schaltbau.info/downloaden! IEC 60947-: Low-voltage switchgear and controlgear, Part : General rules IEC 60947-5-, Annex K: Special requirements for control switches with direct opening action UL508: Industrial control equipment IEC 6059: Degrees of protection provided by enclosures (IP Code) UL 94V-0: Flammability Standard DIN 466-6: Sensitive switches for communication technology; dimensions, type F ISO 849-: Safety of machinery - Safety-related parts of control systems - Part : General principles for design IEC 60068--6: Environmental testing - Part -6: Tests - Test Fc: Vibration (sinusoidal) IEC 60068--7: Environmental testing - Part -7: Tests - Test Ea and guidance: Shock Specifications are subject to alteration without prior notice / Dimensions in mm

Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse 5 889 Munich Germany Phone +49 89 9 0 05-0 Fax +49 89 9 0 05-50 Internet www.schaltbau-gmbh.com e-mail contact@schaltbau.de RoHS 0/65/EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 008. Quality you can count on Schaltbau Certified to DIN EN ISO 400 since 00. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 900 since 994. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements D068/506/.0 Printed in Germany We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com. Issued 08-07