Direct solenoid and solenoid pilot operated valves

Similar documents
Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Specifications 54 Series Valve

MAC VALVES EUROPE, INC.

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

42 Series MAConnect TM. 42 Series Plug-In Manifold

92 Series MAConnect with Sub D

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

MAC VALVES, INC. Rev. T

Bullet Valve (BV) Series

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

MAC Pulse Valve PV06 Series

82 Series MAConnect with Sub-D

MAC Pulse Valve PV03 Series

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

32, CONTENTS SMALL LARGE

Bullet Valve (BV) Series

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Pilot Operated 2 Port Solenoid Valve for Dry Air

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

SST-90 LED Binning and Labeling

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

3 Port Solenoid Valve Direct Operated Poppet Type

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

2005 Series Solenoid Pilot Actuated Valves

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Series 581 ISO Pneumatic Directional Control Valves

Directional Control Valves. General Description. Features. Specifications

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Seated valves 500 bar

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

D05 Directional Control Valves

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

DYNA-POWER LUBRICATION

Contact Air Incorporated for further assistance. Ph:

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Product Information. 80 Series ROSS CONTROLS

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

2/2 Solenoid Operated Seat Valve, ISO Size 03

Spool & Sleeve Valves for ANSI Sub-Bases Series W70

COILS, CONNECTORS, SOLENOID VALVES

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Port Flow Rate/ Function Series Actuators Page Number Size Factor

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

Proportional Valves. Proportional solenoid valves for pressure and flow control

5 Port Solenoid Valve

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

503 Series Solenoid Pilot Actuated Valves

Control & Power, Inc

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Proveedor Integral de Soluciones para la Industria. Desde1963

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

VQ1000. How to Order Manifold. Kit type

Genesis Series Valves Parts List / Service Instructions

5 Port Solenoid Valve

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function

Series VP3145/3165/3185

Серия MAC Pulse Valve PV06

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

ACTUATED THERMOMETERS

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Directional Control Valves. General Description. Features. Specifications

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series

Pilot Operated 2 Port Solenoid Valve for Dry Air

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Action Automation & Controls, Inc.

2/2, 3/2 and 4/2 directional poppet valve with solenoid actuation

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Transcription:

Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in Sub-base plug-in Manifold mounting Sub-base non plug-in Sub-base plug-in 33 34 36 32 onded spool ir return Light option Manual operator Solenoid 4-way pilot with balanced poppet 37 38 52 67 69 44 46 E P E SERIES FETURES Patented MCSOLENOID for fastest possible response times and virtually burn-out proof C solenoid operation. Optional low watt DC solenoids. Optional memory spring. Plug-in design of valves and bases for ease of maintenance. 2 position or 3 position valve configurations. COND. 42 47 48P 48 400 92 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 157 Consult Precautions page 327 before use, installation or service of MC Valves..

EXH. IN. EXH. IN EXH. IN 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS SPOOL CONFIGURTIONS EXH IN EXH 2 POSITION SINGLE PRESSURE SHOWN WITH "" OPERTOR ENERGIZED IN EXH IN 2 POSITION DUL PRESSURE SHOWN WITH "" OPERTOR ENERGIZED EXH IN EXH EXH IN EXH 3 POSITION CLOSED CENTER SPRING CENTERING 3 POSITION OPEN CENTER IN EXH IN REGULTOR CONFIGURTIONS SINGLE REGULTOR - SINGLE PRESSURE Pressure supplied to the individual or manifold base passes through the regulator. Regulated pressure is supplied to the pressure path of the valve. 3 POSITION DUL PRESSURE, PRESSURE CENTER DUL REGULTOR - DUL PRESSURE Pressure supplied from each regulator is divided in the block. Regulated pressure from regulator supplies cylinder port. Regulated pressure from regulator supplies cylinder port. Dual pressure regulators require dual pressure spool in valve. MNIFOLD WITH REGULTOR - SINGLE PRESSURE Note: For both single and dual pressure, air supply to the pilot system is never regulated. MNIFOLD WITH REGULTOR - DUL PRESSURE 158 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves Function Flow (Max) Individual mounting Series, 3/8-1/2 3.8 C v Inline OPERTIONL ENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation. 2. alanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. ir only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS 12 2 4 14 12 2 4 14 Closed center 12 2 4 14 Open center 12 2 4 14 33 34 36 32 37 38 52 67 69 44 46 DUL PRESSURE MODELS 3 1 5 93-J0-0J-DM-DXXX-XXX 93-J0-C0J-DM-DXXX-XXX 93-J0-0K-DM-DXXX-XXX 93-J0-C0K-DM-DXXX-XXX 3 1 5 93-J0-0J-DM-DXXX-XXX 93-J0-C0J-DM-DXXX-XXX 93-J0-0K-DM-DXXX-XXX 93-J0-C0K-DM-DXXX-XXX 3 1 5 93-EJ0-0J-DM-DXXX-XXX 93-EJ0-C0J-DM-DXXX-XXX 93-EJ0-0K-DM-DXXX-XXX 93-EJ0-C0K-DM-DXXX-XXX 3 1 5 93-FJ0-0J-DM-DXXX-XXX 93-FJ0-C0J-DM-DXXX-XXX 93-FJ0-0K-DM-DXXX-XXX 93-FJ0-C0K-DM-DXXX-XXX 42 47 48P 12 2 4 14 12 2 4 14 Pressure center 12 2 4 14 48 SOLENOID OPERTOR DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX J 110/50, 120/60 18 (Flying leads) 1 Non-locking recessed K J 220/50, 240/60 24 (Flying leads) 2 Locking recessed KD JC 24/50, 24/60 J Connector J F 24 VDC (1.8W) JD D 24 VDC (5.4W) DF 24 VDC (12.7W) * Other options available, see page 309. OPTIONS Pilot exhaust : 93-XJX-XXX-DM-DXXX-XXX 3 1 5 J Standard pilot exhaust K Pilot exhaust to main exhaust (use DU pilot) 93-CJ0-0J-DM-DXXX-XXX 93-CJ0-C0J-DM-DXXX-XXX 93-CJ0-0K-DM-DXXX-XXX 93-CJ0-C0K-DM-DXXX-XXX 3 1 5 93-DJ0-0J-DM-DXXX-XXX 93-DJ0-C0J-DM-DXXX-XXX 93-DJ0-0K-DM-DXXX-XXX 93-DJ0-C0K-DM-DXXX-XXX 3 1 5 93-HJ0-0J-DM-DXXX-XXX 93-HJ0-C0J-DM-DXXX-XXX 93-HJ0-0K-DM-DXXX-XXX 93-HJ0-C0K-DM-DXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 400 92 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 Other options available for the 93 series valves, see page 169. 159 Consult Precautions page 327 before use, installation or service of MC Valves..

100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Pilot: 20 to 120 PSI Pilot: Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 3.8 C v Class continuous duty, #22 WG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 V Holding: 4.8 V = 1.8 to 12.7 W Energize : 13 ms De-energize : 10 ms Option : SPP threads DIMENSIONS Dimensions shown are metric (mm) 24.4 52.1 WIXOM,MI.US LIEGE,ELGIUM MODEL UCKLND,N.Z. MODIF. ELECTRICL WTTS 40.3 VC TO 120 PSI 62.9 16.1 Ø 6.20 (2) 12 14 EP 4 2 P 155.8 184.3 SINGLE SOLENOID DOULE SOLENOID 160 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves Function Flow (Max) Individual mounting Series, 1/4-3/8-1/2 3.4 C v Sub-base non plug-in OPERTIONL ENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation. 2. alanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. ir only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS (1/4" MODELS RE OTTOM PORTED) Closed center Open center 33 34 36 32 37 38 52 67 69 44 46 Valve less base 1/4 NPTF 1/4 NPTF SOLENOID OPERTOR 93--000-DM-DXXX-XXX 93--G-DM-DXXX-XXX 93--G-DM-DXXX-XXX 93--CG-DM-DXXX-XXX 93--H-DM-DXXX-XXX 93--H-DM-DXXX-XXX 93--CH-DM-DXXX-XXX 93--000-DM-DXXX-XXX 93--G-DM-DXXX-XXX 93--G-DM-DXXX-XXX 93--CG-DM-DXXX-XXX 93--H-DM-DXXX-XXX 93--H-DM-DXXX-XXX 93--CH-DM-DXXX-XXX DM-D XXX-XXX * 93-E-000-DM-DXXX-XXX 93-E-G-DM-DXXX-XXX 93-E-G-DM-DXXX-XXX 93-E-CG-DM-DXXX-XXX 93-E-H-DM-DXXX-XXX 93-E-H-DM-DXXX-XXX 93-E-CH-DM-DXXX-XXX 93-F-000-DM-DXXX-XXX 93-F-G-DM-DXXX-XXX 93-F-G-DM-DXXX-XXX 93-F-CG-DM-DXXX-XXX 93-F-H-DM-DXXX-XXX 93-F-H-DM-DXXX-XXX 93-F-CH-DM-DXXX-XXX DUL PRESSURE MODELS REQUIRE SNDWICH REGULTOR, SEE REGULTORS SECTION (1/4" MODELS RE OTTOM PORTED) Valve less base 1/4 NPTF 1/4 NPTF 93-C-000-DM-DXXX-XXX 93-C-G-DM-DXXX-XXX 93-C-G-DM-DXXX-XXX 93-C-CG-DM-DXXX-XXX 93-C-H-DM-DXXX-XXX 93-C-H-DM-DXXX-XXX 93-C-CH-DM-DXXX-XXX 93-D-000-DM-DXXX-XXX 93-D-G-DM-DXXX-XXX 93-D-G-DM-DXXX-XXX 93-D-CG-DM-DXXX-XXX 93-D-H-DM-DXXX-XXX 93-D-H-DM-DXXX-XXX 93-D-CH-DM-DXXX-XXX Pressure center E IN E 93-H-000-DM-DXXX-XXX 93-H-G-DM-DXXX-XXX 93-H-G-DM-DXXX-XXX 93-H-CG-DM-DXXX-XXX 93-H-H-DM-DXXX-XXX 93-H-H-DM-DXXX-XXX 93-H-CH-DM-DXXX-XXX 42 47 48P 48 400 92 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 XX Voltage X Wire length X Manual operator XX J 110/50, 120/60 18 (Flying leads) 1 Non-locking recessed M J 220/50, 240/60 24 (Flying leads) 2 Locking recessed N JC 24/50, 24/60 J Connector P F 24 VDC (1.8W) G D 24 VDC (5.4W) J DF 24 VDC (12.7W) JD * Other options available, see page 309. Other options available for the 93 series valves, see page 169. Electrical connection Flying leads Flying leads with diode Flying leads with M.O.V. Flying leads with ground Rectangular connector Rectangular connector with light 161 Consult Precautions page 327 before use, installation or service of MC Valves..

100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Pilot: 20 to 120 PSI Pilot: Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 1/4, 3/8 : (3.0 C v ) - 1/2 : (3.4 C v ) Class continuous duty, #22 WG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 V Holding: 4.8 V = 1 to 12.7 W Energize : 13 ms De-energize : 10 ms Options : Spare parts : SPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC93- (screwdriver slot adjustment) FC93- (locking knob adjustment) Pilot valve: DM-Dxxx-xxx Valve to base pressure seal: 16622 Pilot valve pressure seal: 16542 Mounting screws valve to base (x4): 35249 Pilot valve mounting screws (x2): 35069 DIMENSIONS Dimensions shown are metric (mm) 185.4 DOULE SOLENOID 156.9 SINGLE SOLENOID 80.0 1/8" -27 NPTF EXTERNL PILOT PORT 6.00 53.0 OPTIONL OTTOM PORTS 3/8" ND 1/4" ONLY 111.6 EP 31.65 36.0 IN EX CONDUIT 20.0 M L K J IN EX 23.00 46.00 5.85 13.0 E 39.1 57.0 28.5 H F 1/2" -14 N.P.S.M. CONDUIT PORT 71.7 96.0 5.3 DI 2 MTG. HOLES G C D CYL. CYL. DIM. C D E F G H DIM. J K L M 3/8" 1/2" 27.15 25.5 20.65 19.0 27.15 25.5 24.15 22.5 54.1 45.8 81.7 75.3 38.2 38.2 73.5 73.5 1/4" 3/8" 7.0 8.5 14.7 16.2 15.0 16.5 16.5 17.5 162 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves Function Flow (Max) Individual mounting Series, 1/4-3/8-1/2 3.4 C v Sub-base plug-in OPERTIONL ENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation. 2. alanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. ir only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS (1/4" MODELS RE OTTOM PORTED) Closed center Open center 33 34 36 32 37 38 52 67 69 44 46 Valve less base 1/4 NPTF 1/4 NPTF Valve less base 1/4 NPTF 1/4 NPTF 93--000-DM-DXXP-XXX 93---DM-DXXP-XXX 93---DM-DXXP-XXX 93--C-DM-DXXP-XXX 93--D-DM-DXXP-XXX 93--D-DM-DXXP-XXX 93--CD-DM-DXXP-XXX 93--000-DM-DXXP-XXX 93---DM-DXXP-XXX 93---DM-DXXP-XXX 93--C-DM-DXXP-XXX 93--D-DM-DXXP-XXX 93--D-DM-DXXP-XXX 93--CD-DM-DXXP-XXX 93-C-000-DM-DXXP-XXX 93-C--DM-DXXP-XXX 93-C--DM-DXXP-XXX 93-C-C-DM-DXXP-XXX 93-C-D-DM-DXXP-XXX 93-C-D-DM-DXXP-XXX 93-C-CD-DM-DXXP-XXX 93-E-000-DM-DXXP-XXX 93-E--DM-DXXP-XXX 93-E--DM-DXXP-XXX 93-E-C-DM-DXXP-XXX 93-E-D-DM-DXXP-XXX 93-E-D-DM-DXXP-XXX 93-E-CD-DM-DXXP-XXX 93-D-000-DM-DXXP-XXX 93-D--DM-DXXP-XXX 93-D--DM-DXXP-XXX 93-D-C-DM-DXXP-XXX 93-D-D-DM-DXXP-XXX 93-D-D-DM-DXXP-XXX 93-D-CD-DM-DXXP-XXX 93-F-000-DM-DXXP-XXX 93-F--DM-DXXP-XXX 93-F--DM-DXXP-XXX 93-F-C-DM-DXXP-XXX 93-F-D-DM-DXXP-XXX 93-F-D-DM-DXXP-XXX 93-F-CD-DM-DXXP-XXX DUL PRESSURE MODELS REQUIRE SNDWICH REGULTOR, SEE REGULTORS SECTION (1/4" MODELS RE OTTOM PORTED) SOLENOID OPERTOR DM-D XX P-XXX * Pressure Center E IN E 93-H-000-DM-DXXP-XXX 93-H--DM-DXXP-XXX 93-H--DM-DXXP-XXX 93-H-C-DM-DXXP-XXX 93-H-D-DM-DXXP-XXX 93-H-D-DM-DXXP-XXX 93-H-CD-DM-DXXP-XXX bove models are shown without light. 42 47 48P 48 400 92 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 XX Voltage X Manual operator XX J J JC F D DF 110/50, 120/60 (2.9W) 220/50, 240/60 (2.9W) 24/50, 24/60 (2.9W) 24 VDC (1.8W) 24 VDC (5.4W) 24 VDC (12.7W) 1 Non-locking recessed 2 Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground * Other options available, see page 309. Note: Ground required for 30 Volts or higher. Other options available for the 93 series valves, see page 170. 163 Consult Precautions page 327 before use, installation or service of MC Valves..

100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Pilot: 20 to 120 PSI Pilot: Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 1/4, 3/8 : (3.0 C v ) - 1/2 : (3.4 C v ) Class continuous duty, #22 WG x 18 base leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 V Holding: 4.8 V = 1 to 12.7 W Energize : 13 ms De-energize : 10 ms Options : Spare parts : SPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC93- (screwdriver slot adjustment) FC93- (locking knob adjustment) Pilot valve: DM-DxxP-xxx Valve to base pressure seal: 16622 Pilot valve pressure seal: 16542 Mounting screws valve to base (x4): 35249 Pilot valve mounting screws (x2): 35069 DIMENSIONS Dimensions shown are metric (mm) 185.4 DOULE SOLENOID 156.9 SINGLE SOLENOID 80.0 1/8" -27 NPTF EXTERNL PILOT PORT 6.00 53.0 OPTIONL OTTOM PORTS 3/8" ND 1/4" ONLY 111.6 EP 31.65 36.0 IN EX CONDUIT 20.0 M L K J IN EX 23.00 46.00 5.85 13.0 E 39.1 57.0 28.5 H F 1/2" -14 N.P.S.M. CONDUIT PORT 71.7 96.0 5.3 DI 2 MTG. HOLES G C D CYL. CYL. DIM. C D E F G H DIM. J K L M 3/8" 1/2" 27.15 25.5 20.65 19.0 27.15 25.5 24.15 22.5 54.1 45.8 81.7 75.3 38.2 38.2 73.5 73.5 1/4" 3/8" 7.0 8.5 14.7 16.2 15.0 16.5 16.5 17.5 164 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves Function Flow (Max) Manifold mounting Series, 3/8-1/2 3.8 C v Sub-base non plug-in OPERTIONL ENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation. 2. alanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. ir only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS Closed center Open center 33 34 36 32 37 38 52 67 69 44 46 Valve less base SOLENOID OPERTOR 93--000-DM-DXXX-XXX 93--JG-DM-DXXX-XXX 93--CJG-DM-DXXX-XXX 93--JH-DM-DXXX-XXX 93--CJH-DM-DXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX J 110/50, 120/60 18 (Flying leads) 1 Non-locking recessed M J 220/50, 240/60 24 (Flying leads) 2 Locking recessed N JC 24/50, 24/60 J Connector K F 24 VDC (1.8W) KD D 24 VDC (5.4W) DF 24 VDC (12.7W) * Other options available, see page 309. End plate kit required (1/2 ports): M-93001-01-01 internal pilot. M-93001-02-01 external pilot. Other options available for the 93 series valves, see page 169. 93--000-DM-DXXX-XXX 93--JG-DM-DXXX-XXX 93--CJG-DM-DXXX-XXX 93--JH-DM-DXXX-XXX 93--CJH-DM-DXXX-XXX 93-E-000-DM-DXXX-XXX 93-E-JG-DM-DXXX-XXX 93-E-CJG-DM-DXXX-XXX 93-E-JH-DM-DXXX-XXX 93-E-CJH-DM-DXXX-XXX DUL PRESSURE MODELS (REQUIRE SNDWICH REGULTOR, SEE REGULTORS SECTION) Valve less base 93-C-000-DM-DXXX-XXX 93-C-JG-DM-DXXX-XXX 93-C-CJG-DM-DXXX-XXX 93-C-JH-DM-DXXX-XXX 93-C-CJH-DM-DXXX-XXX 93-D-000-DM-DXXX-XXX 93-D-JG-DM-DXXX-XXX 93-D-CJG-DM-DXXX-XXX 93-D-JH-DM-DXXX-XXX 93-D-CJH-DM-DXXX-XXX 93-F-000-DM-DXXX-XXX 93-F-JG-DM-DXXX-XXX 93-F-CJG-DM-DXXX-XXX 93-F-JH-DM-DXXX-XXX 93-F-CJH-DM-DXXX-XXX Pressure center E IN E 93-H-000-DM-DXXX-XXX 93-H-JG-DM-DXXX-XXX 93-H-CJG-DM-DXXX-XXX 93-H-JH-DM-DXXX-XXX 93-H-CJH-DM-DXXX-XXX bove models are shown with side ports. Electrical connection Flying leads Flying leads with diode Square connector Square connector with light 42 47 48P 48 400 92 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 165 Consult Precautions page 327 before use, installation or service of MC Valves..

100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Pilot: 20 to 120 PSI Pilot: Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 3/8 : (3.4 C v ) - 1/2 : (3.8 C v ) Class continuous duty, #22 WG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 V Holding: 4.8 V = 1 to 12.7 W Energize : 13 ms De-energize : 10 ms Options : Spare parts : SPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC93- (screwdriver slot adjustment), FC93- (locking knob adjustment) Pilot valve: DM-Dxxx-xxx Valve to base pressure seal: 16622 Pilot valve pressure seal: 16542 Mounting screws valve to base (x4): 35249 Inlet/exh. Isolator disc: N-93008 Valve blanking plate: M-93002 DIMENSIONS Dimensions shown are metric (mm) DOULE SOLENOID 203.73 1/8" N.P.T.F. PILOT PORT 3 PLCES SINGLE SOLENOID 182.38 10.55 31.5 87.50 6.3 DI 4 MTG. HOLES 19.05 14.6 33.5 19.05 33.0 EP EP 15.0 57.0 35.5 33.0 EP 27.0 E IN E EX CONDUIT 37.5 19.05 33.5 11.5 39.0 70.0 105.0 143.6 1/2" NPTF 3HOLES OTH ENDS 10.55 64.70 22.80 OPTIONL OTTOM PORTS 3/8" & 1/2" # 1 2 3 4 5 6 7 8 9 10 DIM. 71.6 105.1 138.6 172.1 205.6 239.1 272.6 306.1 339.6 373.1 3/8" 1/2" 47.66 49.32 166 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves Function Flow (Max) Manifold mounting Series, 3/8-1/2 3.8 C v Sub-base plug-in OPERTIONL ENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation. 2. alanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation. 3. ir only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS Closed center Open center 33 34 36 32 37 38 52 67 69 44 46 Valve less base 93--000-DM-DXXP-XXX 93--J-DM-DXXP-XXX 93--CJ-DM-DXXP-XXX 93--JD-DM-DXXP-XXX 93--CJD-DM-DXXP-XXX 93--000-DM-DXXP-XXX 93--J-DM-DXXP-XXX 93--CJ-DM-DXXP-XXX 93--JD-DM-DXXP-XXX 93--CJD-DM-DXXP-XXX 93-C-000-DM-DXXP-XXX 93-C-J-DM-DXXP-XXX 93-C-CJ-DM-DXXP-XXX 93-C-JD-DM-DXXP-XXX 93-C-CJD-DM-DXXP-XXX 93-E-000-DM-DXXP-XXX 93-E-J-DM-DXXP-XXX 93-E-CJ-DM-DXXP-XXX 93-E-JD-DM-DXXP-XXX 93-E-CJD-DM-DXXP-XXX DUL PRESSURE MODELS (REQUIRE SNDWICH REGULTOR, SEE REGULTORS SECTION) Valve less base SOLENOID OPERTOR 93-D-000-DM-DXXP-XXX 93-D-J-DM-DXXP-XXX 93-D-CJ-DM-DXXP-XXX 93-D-JD-DM-DXXP-XXX 93-D-CJD-DM-DXXP-XXX XX Voltage X Manual operator XX J J JC F D DF 110/50, 120/60 (2.9W) 220/50, 240/60 (2.9W) 24/50, 24/60 (2.9W) 24 VDC (1.8W) 24 VDC (5.4W) 24 VDC (12.7W) DM-D XX P-XXX * 1 Non-locking recessed 2 Locking recessed 93-F-000-DM-DXXP-XXX 93-F-J-DM-DXXP-XXX 93-F-CJ-DM-DXXP-XXX 93-F-JD-DM-DXXP-XXX 93-F-CJD-DM-DXXP-XXX Pressure Center E IN E 93-H-000-DM-DXXP-XXX 93-H-J-DM-DXXP-XXX 93-H-CJ-DM-DXXP-XXX 93-H-JD-DM-DXXP-XXX 93-H-CJD-DM-DXXP-XXX bove model numbers are shown with side ports without light. DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground 42 47 48P 48 400 92 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 * Other options available, see page 309. End plate required (1/2 ports): M-93001-01-01 pilot. M-93001-02-01 pilot. Other options available for the 93 series valves, see page 170. 167 Consult Precautions page 327 before use, installation or service of MC Valves..

100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICL DT Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Pilot: 20 to 120 PSI Pilot: Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F (-18 C to +50 C) 3/8 : (3.4 C v ) - 1/2 : (3.8 C v ) Class continuous duty, #22 WG x 18 base leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 V Holding: 4.8 V = 1 to 12.7 W Energize : 13 ms De-energize : 10 ms Options : Spare parts : SPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC93- (screwdriver slot adjustment), FC93- (locking knob adjustment) Pilot valve: DM-DxxP-xxx Valve to base pressure seal: 16622 Pilot valve pressure seal: 16542 Mounting screws valve to base (x4): 35249 Inlet/exh. Isolator disc: N-93008 Valve blanking plate: M-93002 DIMENSIONS Dimensions shown are metric (mm) DOULE SOLENOID 203.73 1/8" N.P.T.F. PILOT PORT 3 PLCES SINGLE SOLENOID 182.38 10.55 31.5 87.50 6.3 DI 4 MTG. HOLES 19.05 141.6 33.5 19.05 33.0 EP EP 15.0 57.0 35.5 33.0 27.0 EP E IN EX E CONDUIT 37.5 19.05 33.5 11.5 39.0 70.0 105.0 143.6 1/2" NPTF 3HOLES OTH ENDS 10.55 64.70 22.80 OPTIONL OTTOM PORTS 3/8" & 1/2" # 1 2 3 4 5 6 7 8 9 10 DIM. 71.6 105.1 138.6 172.1 205.6 239.1 272.6 306.1 339.6 373.1 3/8" 1/2" 47.66 49.32 168 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves OPTIONS FOR NON PLUG-IN ND INLINE VLVES Valve function 93-LXX-XXX-XX-DXXX-XXX Pilot exhaust 93-XX-XXX-XX-DXXX-XXX L for single operator, single pressure with memory spring N for single operator, dual pressure with memory spring R for single operator universal spool (ext. pilot only) S for double operator universal spool (ext. pilot only) standard pilot exhaust D pilot exhaust to main valve exhaust* Port configuration : Individual sub-base 93-XXX-XX-XX-DXXX-XXX Manifold sub-base 93-XXX-XJX-XX-DXXX-XXX 33 34 36 32 37 38 52 67 69 44 46 Pilot style : side ports (3/8 & 1/2" only) bottom ports (1/4 & 3/8" only) C side & bottom ports (1/4" & 3/8 only) D side inlet & exhaust with bottom cylinder ports (1/4" & 3/8 only) J side ports K bottom ports 42 47 48P 93-XXX-XXX-DM-DXXX-XXX DM pilot exhaust muffled DP pilot exhaust piped (#10-32) DU pilot exhaust to main exhaust 48 ase only : 93-000-XXX (i.e. 93-000-G) - Individual base 93-000-XXX (i.e. 93-000-JG) - Manifold base 400 92 * Must use DU pilot. Main valve exhaust cannot be restricted. 93 ISO 01 ISO 02 ISO 1 ISO 2 ISO 3 169 Consult Precautions page 327 before use, installation or service of MC Valves..

Direct solenoid and solenoid pilot operated valves OPTIONS FOR PLUG-IN VLVES Valve function 93-LXX-XXX-XX-DXXP-XXX L for single operator, single pressure with memory spring N for single operator, dual pressure with memory spring R for single operator universal spool (ext. pilot only) S for double operator universal spool (ext. pilot only) Pilot exhaust 93-XX-XXX-XX-DXXP-XXX standard pilot exhaust C pilot exhaust to main valve exhaust* ody electrical 92-XX-XXX-XX-DXXP-XXX no light light(s) Port configuration : Individual sub-base 93-XXX-XX-XX-DXXP-XXX side ports (3/8 & 1/2" only) bottom ports (1/4 & 3/8" only) C side & bottom ports (1/4" & 3/8 only) D side inlet & exhaust with bottom cylinder ports (1/4" & 3/8 only) Manifold sub-base 93-XXX-XJX-XX-DXXP-XXX J side ports K bottom ports ase/manifold int./ext. pilot 93-XXX-XX-XX-DXXP-XXX Pilot style : 93-XXX-XXX-DM-DXXP-XXX internal pilot no light internal pilot single light C internal pilot double light D external pilot no light E external pilot single light F external pilot double light DM pilot exhaust muffled DP pilot exhaust piped (#10-32) DU pilot exhaust to main exhaust ase only : 93-000-XXX (i.e. 93-000-) - Individual base (Note: bases are wired for double solenoid valves) * Must use DU pilot. Main valve exhaust cannot be restricted. 93-000-XXX (i.e. 93-000-J) - Manifold base 170 Consult Precautions page 327 before use, installation or service of MC Valves..

OPTIONS Codification table for voltages / Manual operator / Electrical connection VLVE CODE -DM- D XX X-X XX 1 2 3 4 - Pilot operated valves 52, 67, 92, 93, 400, ISO1, ISO2, ISO3 Series OPTIONS VILLE FOR 309 Consult Precautions page 327 before use, installation or service of MC Valves..

OPTIONS 1. VOLTGE D-XX X-X XX VOLTGE D 24 VDC (5.4W) D 12 VDC (5.4W) DC 12 VDC (7.5W) DD 24 VDC (7.3W) DE 12 VDC (12.7W) DF 24 VDC (12.7W) DK 110 VDC (4.7W) DJ 28 VDC (5.2W) DL 64 VDC (6.0W) DM 36 VDC (5.3W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 110 VDC (7.3W) DT 75 VDC (5.6W) DP 48 VDC (5.8W) F 12 VDC (1.8W) F 24 VDC (1.8W) FE 12 VDC (2.4W) FF 24 VDC (2.4W) J 120/60, 110/50 (2.9W) J 240/60, 220/50 (2.9W) JC 24/60, 24/50 (3.7W) JD 100/60, 100/50, 110/60 (3.9W) JE 220/60 (3.4W) JF 240/50 (2.8W) JG 200/60, 200/50 (3.9W) 2. WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires 18" 24" C 36" D 48" E 72" F 96" 4. ELECTRICL CONNECTION D-XX X-X XX ELECTRICL CONNECTION * Flying leads (grommet) K* with protection diode L* with protection varistor M** Flying leads (solenoid plug-in) N** M with protection diode P** M with protection varistor G** M with ground H** M with protection diode & ground J** M with protection varistor & ground C* 1/2" NPS conduit with flying leads CM* 1/2" NPS metal conduit with flying leads CN* 1/2" NPS metal conduit with flying leads & ground J Rectangular connector JD J with light JM Rectangular connector (male only) K Mini square connector K K with protection diode KC K with protection varistor KD K with light KE K with light and protection diode KF K with light and protection varistor KG K with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) T Dual tabs with receptacles T T with protection diode TD T with light TE T with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose through F ** From Lead wire length options choose 0 through F Note: When coil is above 30 volts, a ground wire is required. pplies to options with flying leads. 3. MNUL OPERTOR D-XX X-X XX MNUL OPERTOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 310 Consult Precautions page 327 before use, installation or service of MC Valves..