Double throttle check valve Type Z2FS 10

Similar documents
Pressure reducing valve, pilot operated Type DR

Check valve cartridge Type M-SR

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

2/2-way poppet valves with solenoid operation Type KSDER1

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure relief valve, pilot operated

Pressure reducing valve, pilot operated

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

RC /

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Check valve, pilot operated

Throttle and throttle check valve

Twin throttle check valve

2-way flow control valve

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Pressure relief valve, pilot operated

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Return line filter for direct tank mounting Type ABZFR

Pressure sequence valve, direct operated

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Pressure sequence valve, direct operated

Pressure reducing valve, direct operated

Reservoir oil filler/breather

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

Supply pressure compensator, direct operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Pressure reducing valve, direct operated, with pressure monitoring

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Meter-in pressure compensator, direct operated

Throttle and throttle check valve

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Pressure reducing valve, direct operated

Pressure relief valve, pilot operated

Pressure relief valve, directly operated

2-way flow control valve

Proportional flow control valve, with integrated pressure compensator

Electro-Proportional Pressure Reducing and Relieving Cartridge Valves

Pressure relief valve, pilot operated

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, direct operated

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Check valve, pilot operated

Hydro-electric pressure switch

Proportional pressure relief valve, directly operated, rising characteristic curve

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Bourdon tube pressure switch with infinitely variable switching pressure differential

Check valve, pilot operated

Check valve, pilot operated

Hydraulic cylinder Type CDL1

3/2 and 4/2 directional seat valves with solenoid actuation

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Vane pump, direct operated Type PV7 A

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional pressure reducing valve, pilot operated

4-way directional servo valve Type 4WS.2E

Throttle and throttle check valve

2/2 directional seat valve, direct operated with solenoid actuation

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Check valve. Type S. Contents. Features. RE Edition: Replaces:

RK / HED 3 OA3X/.. with plug-in connector HED 3 OA3X/..K6.. HED 3 OA3X/..KL..Q with plug-in connector. with plug-in connector

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical position feedback Types 4WRA and 4WRAE

Check valve, pilot operated

3/2 and 4/2 directional poppet valve with solenoid actuation

3/2 directional spool valve, direct operated with solenoid actuation

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Fixed displacement vane pumps Types PVV and PVQ

RK /02.03 HED 2 OA 2X/.. HED 2 OA 2X/..L.. HED 2 OA 2X/..KL.. HED 2 OA 2X/..K.. HED 2 OA 2X/..K6.. HED 2 1/6 RK /02.

Winch control block. RE 65051/08.04 Replaces: Type YM-WCB

Pipe burst safety valve

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Servo directional valve of 4-way design Type 4WS.2E

Hydraulic Motor (Radial Piston, Multi-Stroke)

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

Proportional flow control valve, 2-way version

Proportional pressure reducing valve, 3-way variant, pilot operated

Double throttle/check valve Type Z2FS B/ (New Series) Huade América 1

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Hydraulic inch power brake valve LT 31

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Servo solenoid valves with positive overlap and on-board electronics

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Hydraulic drive power unit Low noise compact unit Wispering power unit

Servo solenoid valves with on-board electronics (OBE)

2-way proportional throttle valve for block installation

Hydraulic primary unit Type ABPAG

Proportional flow control valve, with inductive position transducer

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

LUDV control block of sandwich plate design

Transcription:

RE 7 58/0.03 Replaces:.0 Double throttle check valve Type ZFS 0 Nominal size 0 Series 3X Maximum operating pressure 35 bar Maximum flow 0 L/min Overview of contents Contents Page Features Ordering details Symbols Preferred types Function, section Technical data 3 Characteristic curves 3 Unit dimensions 4, 5 Ordering details Double throttle check valve Nominal size 0 0 Throttle check valve ports A and B ) Throttle check valve port A A Throttle check valve port B B Adjustment element Lockable rotary knob with scale 3 ) Spindle with internal hexagon and scale 5 Rotary knob with scale 7 ) Identical adjustment elements on ports A and B. H/A/D 555/9 Type ZFS 0 5-3X/.V ZFS 0 3X V ) H-key with Material No. R90000858 is included within the scope of supply. Preferred types, see page, are readily available Features Sandwich plate valve Porting pattern to DIN 4 340 Form A, ISO 440 and CETOP RP H For limiting the main or control fluid flow of actuator connections 3 adjustment elements: Lockable rotary knob with scale Spindle with internal hexagon and scale Rotary knob with scale For meter-in or meter-out control V No code S * Further details in clear text FKM seals (other seals on request) Attention! The compatibility of the seals and pressure fluid has to be taken into account! (With two throttle check valves) Meter-in or meter-out throttling (this valve can be rotated) (...A. 3X/S) meter-in on port A (...B. 3X/S) meter-in on port B S (...A. 3X/S) meter-out on port A (...B. 3X/S) meter-out on port B 3X Series 30 to 39 (30 to 39: unchanged installation and connection dimensions) 003 by Bosch Rexroth AG, Industrial Hydraulics, D-9783 Lohr am Main All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using electronic systems, in any form or by any means, without the prior written authorisation of Bosch Rexroth AG. In the event of contravention of the above provisions, the contravening party is obliged to pay compensation. ZFS 0 / RE 7 58/0.03

Symbols ( component side, subplate side) ZFS 0.. 3X/.. (meter-in) ZFS 0.. 3X/.. (meter-out) TA P A B TA P A B Preferred types (readily available) Type Material number ZFS 0-5-3X/V R900578 ZFS 0A5-3X/SV R90053578 ZFS 0A5-3X/SV R9005783 Further preferred types and standard units can be found in the EPS (Rexroth Price List). Function, section Valve type ZFS 0 is a double throttle check valve of sandwich plate design. It is used to limit the main or pilot oil flow of one or two actuators. Two symmetrically arranged throttle check valves limit the flow in one direction and allow free-flow in the opposite direction. With meter-in control the pressure fluid passes through port A via the throttle area (), that is created by the valve seat () and the throttle spool (3.), to the actuator A. The throttle spool (3.) is axially adjustable via the adjustment screw (4) and thus enables the throttling point to be set (). Simultaneously the pressure fluid present in port A is passed to the piston side of the throttle spool () via drilling (5). The applied pressure, in addition to the spring force holds the throttle spool (3.) in the throttling position. The pressure fluid returning from actuator B moves the throttle spool (3.) against the spring (7) and thus enables unrestricted flow via the check valve. Depending on the installation orientation the throttling effect may be arranged as meter-in or meter-out control. Limiting the main fluid flow In order to change the velocity of an actuator (main fluid flow), the double throttle check valve is installed between the directional valve and the subplate. Limiting the control fluid flow With pilot operated directional control valves, the double throttle check valve is installed as a switching time adjustement (control fluid flow). It is fitted between the main valve and the pilot valve. 5 A B A B 4 3. 3. 7 Type ZFS 0 5 3X/.V (meter-in) RE 7 58/0.03 / ZFS 0

Technical data (for applications outside these parameters, please consult us!) General Installation Optional Ambient temperature range C 0 to +80 for FKM seals Weight kg Approx. 3. Hydraulic Pressure fluid Mineral oil (HL, HLP) to DIN 5 54; Fast bio-degradable pressure fluids to VDMA 4 58 (also see RE 90 ); HETG (rape seed oil); HEPG (polyglycols); HEES (synthetic ester); Other pressure fluids on request Cleanliness class to ISO code Maximum permissible degree of contamination of the pressure fluid is to ISO 440 (C) class 0/8/5 ) Pressure fluid temperature range C 0 to +80 for FKM seals Viscosity range mm /s 0 to 800 Operating pressure, max. bar Up to 35 Flow, max. L/min Up to 0 ) The cleanliness class stated for the components must be adhered too in hydraulic systems. Effective filtration prevents faults from occurring and at the same time increases the component service life. For the selection of filters see catalogue sheets RE 50 070, RE 50 07 and RE 50 08. Characteristic curves (measured at ν 4 mm /s, ϑ oil 40 C ± 5 C) Pressure differential p in relation to the flow q V across the check valve Pressure differential in bar Pressure differential in bar 8 4 0 80 50 00 50 0 5 0 0 30 40 50 0 70 80 90 00 0 0 30 40 50 0 Flow in L/min Pressure differential p in relation to the flow q V at a constant throttle setting 3 45,5 7 7,5 8 8,5 9 0 40 80 0 0 Flow in L/min 9,5 0 0,5,5 ZFS 0 3/ RE 7 58/.0 Throttle setting in turns Throttle closed Throttle open

Unit dimensions: type ZFS 0. 3X/ (Dimensions in mm) 48,5 3 3; 4 0 3; 4 30 Ø3 0 9 8 3 0 9 8 Ø3 0 345 0 9 9 7 53 70 0 84,5 4 x Ø,7 70 x 80 5 x Ø 4 54 TA A 88 X P B 40,7 X Ø 0 Ø 8 (A, B) 4 x Ø,7 Attention! Where drillings for X and Y ports are required, version SO30 applies! (e. g. NS 0 pilot operated directional valves) 5 8 Ø 7,5 (TA, ) 0,0/00mm R max4 Required surface finish of the mating piece Name plate Adjustment "5" Spindle to adjust the flow cross-section (internal hexagon 8A/F) Anti-clockwise rotation increase in flow Clockwise rotation decrease in flow 3 Adjustment "3" 4 Adjustment "7" 5 4 through holes for valve fixing screws Identical seal rings for ports A, B, P, TA, 7 R-ring plate 8 To change from meter-in to meter-out, rotate the unit about the "X" "X" axis 9 Space required to remove the key 0 Only for adjustment "7" Valve fixing screws M DIN 9-0.9, Tightening torque M A 5.5 Nm must be ordered separately. RE 7 58/0.03 4/ ZFS 0

3 Unit dimensions: types ZFS 0 A and ZFS 0 B (Dimensions in mm) 0 5 5 Type ZFS 0 A. 3X/ 9 0 9 8 3; 4,5 9 7 4 x Ø,7 70 x 80 5 x Ø 5 5 Type ZFS 0 B. 3X/ 8 48,5 3 0 9 7 53,5 3; 4 4 x Ø,7 70 x 80 5 x Ø 84 5 5,5 5 5,5 88 54 70 4 TA A P B 40,7 Ø 0 Attention! Where drillings for X and Y ports are required, version SO30 applies! (e. g. for NS 0 pilot operated directional valves) Name plate Adjustment "5" Spindle to adjust the flow crosssection (internal hexagon 8A/F) Anti-clockwise rotation increase in flow Clockwise rotation decrease in flow 4 x Ø,7 3 Adjustment "3" 4 Adjustment "7" 5 4 through holes for valve fixing screws Identical seal rings for ports A, B, P, TA, 7 R-ring plate 9 Space required to remove the key 5 Ø 8 (A, B) Ø 7,5 (TA, ) 0,0/00mm R max4 Required surface finish of the mating piece Valve fixing screws M DIN 9-0.9, Tightening torque M A 5.5 Nm must be ordered separately. ZFS 0 5/ RE 7 58/.0

Notes Bosch Rexroth AG Industrial Hydraulics D-9783 Lohr am Main Zum Eisengießer D-978 Lohr am Main Telefon 0 93 5 / 8-0 Telefax 0 93 5 / 8-3 58 Telex 89 48-0 email documentation@boschrexroth.de Internet www.boschrexroth.de Bosch Rexroth Limited Cromwell Road, St Neots, Cambs, PE9 ES Tel: 0 4 80/ 3 5 Fax: 0 4 80/ 90 5 E-mail: info@boschrexroth.co.uk The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The details stated do not release you from the responsibility for carrying out your own assessment and verification. It must be remembered that our products are subject to a natural process of wear and ageing. RE 7 58/.0 / ZFS 0