MOTOR. The electric motor. DC - direct current voltage.

Similar documents
M OTO R. The electric motor. DC - direct current voltage.

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

Type 2000 Transducer Product Instructions

Rental Industry Safety Tester Safe Check 5s

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

PNEUMATIC PUMP Series

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data

SureFire II Lubricator

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

PRODUCT SERVICE MANUAL

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

SUBMERSIBLE WATER PUMP

Hydraulic Immediate Need Power Pack

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block

LM-200 MECHANICAL LUBE METER Owner s Manual

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

SureFire II Lubricator

Operators Manual TTN LUBRICATOR Series Progressive r#9

MICROFLOCKER. Operating Instructions

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

OPERATING INSTRUCTION

Operation Manual Cobra 1 Automatic Spray Gun

12VDC TO 230VAC INVERTERS

Product Service Manual For DLH12DHT SERIES PUMPS

3. Operating instructions: Minor 200

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

User Guide for Logo Projector

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

OPERATING INSTRUCTION

Arctic Equipment Manufacturing Corporation M3551 Hydraulic Power Unit. Table of Contents

DC POWER SUPPLY ALIMENTATION C.C.

Techcon Systems TS5000 Series Rotary Valve

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

PM300E Voltage Regulator Instruction Manual

Users Manual. Phase Rotation Indicator

surefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) 35027E R

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

Multiline Pump Model 205

MF /MS Series

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

Purging Air From Divider Block Lubrication Systems

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D-275 SERIES PUMPS (Idler Cup and Hydrostatic Thrust Designs)

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

D-04/G-04 Maintenance

SERVICE GUIDE 8540-B 8549-B C. High-Pressure Lubricant Pump DESCRIPTION. Pump Assembly. Specifications

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2

WALKIE HIGH LIFT HYDRAULIC SYSTEM

PRODUCT SERVICE MANUAL FOR. F312XICR-312_, 325_, 400_ and 437_ Pumps. For Solar Turbines

OPERATING INSTRUCTION

US - UP2/OIL 12V US - UP2/OIL 24V

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

K12DHZ-312P Pump PRODUCT SERVICE MANUAL. Imo Part Number / BOM # 3220/523

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

1200W INVERTER GENERATOR

OWNER S MANUAL MODEL: PT 450 / PT 450M WELDING POSITIONER

Model &

OWNER S MANUAL POWER INVERTER

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

Installation & Operating Manual

DIAPHRAGM LIQUID PUMP NF 1.25

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

Dragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE

Battery Power Inverters

D/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

INSTRUCTION MANUAL AND PARTS LIST FOR 3SIC AND 4SIC SERIES PUMPS

LEAD ACID BATTERY CHARGER

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Instructions Parts List

Owner s Manual. PowerVerter PV1000HF, PV1800HF & PV3000HF DC-to-AC Inverters. Contents. Reliable AC Power Wherever You Need It!

INSTRUCTION MANUAL AND PARTS LIST FOR. (A)E3LB(C)(K)-187, -200, and -250 SERIES PUMPS

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Transcription:

TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily injury. The TMD-5 lubricator meets all operating parameters for single line resistance centralized lubricating systems incorporating Bijur Delimon meter units. Definition of Precautions and Symbols The following symbols, used to identify safety instructions, are defined as follows: Non-compliance will affect safety. Electrical safety is involved. The following symbols, used to identify the lubricant low level switch within the lubricator, are defined as follows: Normally closed electrical contacts (contacts close on low lubricant level). Normally open electrical contacts (contacts close on low lubricant level). Safe operation of the lubricator and/ or protection of the lubricator should be considered. MOTOR The electric motor. Electrical connections made to Earth ground. AC - alternate current voltage. Conditions and actions that pose hazards to the user. Increase and decrease of lubricant discharge adjustment. Lifting collar and turning counterclockwise will increase lubricant discharge. DC - direct current voltage. Declaration of Conformity Bijur Model TMD-5, Automatic, Cyclic Lubricator MANUFACTURER Bijur Lubricating Corporation, A Subsidiary of Industrial Manufacturing Company International STATEMENT OF CONFORMITY Based on test results using appropriate standards, the product is in conformity with: + Machinery Directive 89/392/EEC + Electromagnetic Compatibility Directive 89/336/EEC + Low Voltage Directive 73/23/EEC + Amendments 93/68/EEC, 92/31/EEC This Conformity is indicated by the symbol i.e. Conformité européenne SAMPLE TESTS Standards used: + Safety of Household and Similar Electrical Appliances, EN 60335-1 (including amendments A2, A5, A6, A51,A53, and A54), EN 60335-2-41 (including amendment A1) + Electromagnetic Compatibility Generic Emissions Standard, EN 50081-1 (1992) + Electromagnetic Compatibility Generic Immunity Standard, EN 50082-1 (1992) + Pumps and Pump Units for Liquids General Safety Requirements, pren 809 (1995) All tests have been performed in a typical configuration. 1

Operation The TMD-5 lubricator includes a motor-driven, spring discharge piston pump. The unit may be operated manually by raising and releasing the manual feed knob. Volume of lubricant discharged for each cycle is selected using adjustment shown on marked indicator rod. Cycle time is fixed by an internal gear reduction motor which runs continuously when powered. A lubricant low level switch is provided for signalling low level condition. Use clean oil only of the type and viscosity recommended by machine manufacturer. This lubricator must not be used in explosive atmospheres and must not be used for pumping highly flammable liquids. Technical Data Motor Single phase Power Rating 3 watts, 50/60 Hz Current (Average Values) 15mA (230 VAC), 30mA (115 VAC). 33mA (24 VDC) Supply Voltage 115/230 VAC ±10%, 50/60 Hz, 24 VDC Protection IP52 Discharge Volume Adjustable, 1-5cc per cycle Discharge Pressure 4.1 bar (60 psi) maximum Connection Port 5/16-24 inch female for tube ø 4mm (5/32 ) O.D. Reservoir Lubricant 1.8 liters (110 cu. in.) plastic Viscosity 27-1700 cst (150-8000 SSU) at operating temperature Operating Temperature 5 C to 40 C (40 F to 105 F) Suction Filter 40 micron (nominal) Low Level Switch Contact rating: 10 watts maximum Weight 2 kg (4.5 lbs) Noise Emission Less than 70dB(A) Low Level Switch This lubricator is equipped with a low lubricant level switch. It is factory set to open an electrical circuit whenever the lubricant level in the reservoir becomes low and must be refilled. The switch contacts may be changed from 0-50 115 230 AC.20.08.04 DC.13.05.02 normally open (empty reservoir) to normally closed by inverting the float. The switch will then close an electrical circuit whenever the lubricant level is approaching empty. This switch is not intended to directly turn off the motor or illuminate a lamp. The electrical circuit for the level switch must not exceed 10 watts. Volts Amperes 2

Installation Mounting: Two 7mm (0.27 ) diameter holes are provided near the back of the lubricator for mounting. The surface on which the lubricator is mounted must be capable of supporting 3.4 kg (7.5 lbs). In order to access electrical connections without removing the lubricator from mounting surface, allow for sufficient space above the lubricator. Note: For reservoir removal, allow 115mm (4.5 inches) below bottom of reservoir. Removal of the reservoir is required to change the suction filter disc. Electrical Access to electrical connections is accomplished through two 22mm diameter holes provided in the cover. The main power supply must be fused, since protection is not supplied internally with the lubricator. An electrical noise suppressor is included and has been factory installed for 115 VAC operation. For 230 VAC operation, see the wiring change required below. View of Electrical Strip (shown with suppressor wired for 115 VAC connection) 115 Volt AC Operation The neutral conductor must be connected to terminal number 6 indicated by N. The hot conductor must be connected to terminal number 5. The ground wire must be attached to terminal number 1 indicated by. Before performing service to lubricator, always turn off and disconnect electrical power. When connecting lubricator, make sure that unit is securely and adequately grounded. Failure to ground properly may cause serious injury. An approved electrical connection fitting must be used to prevent ingress of fluid into the motor compartment. Do not connect any wires to terminal number 4. The suppressor is factory supplied attached to terminals 5 and 6 for 115 volt operation. 3 230 Volt AC Operation The neutral conductor must be connected to terminal number 6 indicated by N. The hot conductor must be connected to terminal number 4. The ground wire must be attached to terminal number 1 indicated by. The suppressor wire must be removed from terminal number 5 and installed in terminal number 4. The red motor wire remains connected to terminal number 5. 24 Volt DC Operation Connect 24 VDC power to the motor, wire codes: Red wire possitive / Black wire is negitive. Wiring Diagram (115 VAC) Wiring Diagram (230 VAC) Wiring Diagram (24 VDC)

Startup Instructions Fill reservoir with clean approved lubricant until lubricant level is within 25mm (1 inch) from the top of the reservoir. Attach 5/16-24 inch tube fitting to discharge port and tighten to 3.4 Nm (30 in. lb.) torque. If lubricant distribution system has not been previously primed with lubricant, it is necessary to prime the system manually to purge air from the system before operating machinery. This may be accomplished by manually operating the TMD-5 lubricator. Raise and release the manual feed knob several times until lubricant flows at all bearing points. Adjust lubricant delivery volume as needed. Lubricant Discharge Adjustment The amount of lubricant delivered for each stroke of the piston is adjustable from 1 to 5 cubic centimeters. Adjustment is made by raising the collar with indicator window andturning manual feed knob and collar. To decrease delivery volume, turn clockwise. To increase delivery, turn counter-clockwise. Return collar to original position to lock adjustment setting in place. Approximate lubricant discharge setting in cubic centimeters is indicated by graduations appearing near the center of the window in the collar. For exact delivery, it is always best to measure delivery using a graduated cylinder. Lubricant delivery per hour is equal to the number of cycles per hour times the discharge volume per cycle. Typical System Layout 4

How to Order Name Cycle Time Part # 50 Hz 60 Hz 115/230 VAC 24 VDC TMD-5 Lubricator 6.4 min. 5.3 min. 26350-1 - 10.7 min. 8.9 min. 26350-2 - 16.0 min. 13.3 min. 26350-3 - 33.2 min. 27.7 min. 26350-4 32295 64.0 min. 53.3 min. 26350-5 - 128.0 min. 106.7 min. 26350-6 - Before performing service to lubricator, always turn off and disconnect electrical power. When connecting lubricator, make sure that unit is securely and adequately grounded. Failure to ground properly may cause serious injury. When ordering, specify by name and part number, e.g. TMD-5 Lubricator, Part #26350-3. Service Parts Order by part number and name shown below. If you are unsure of the service part needed, include complete lubricator part number and serial letters as shown on nameplate. For major repairs requiring parts not identified on the drawing, return the lubricator for factory rebuilding and adjustment. If a new lubricator is required for replacement, order by part number shown on the nameplate. Item Part # Description 1-3* 26361 Filter Group Kit 1* 20577 Spring Clip 2* B3747 Filter Disc 3* B3746 Filter Screen 4 20324- KIT Reservoir 5 B9640 Level Switch N.O.** 5A 20256 Level Switch N.O. with rod** 6 22285 Filler Screen 7 24278-3 Motor/Lubricator 26350-1 24278-1 Motor/Lubricator 26350-2 24278-6 Motor/Lubricator 26350-3 24278-2 Motor/Lubricator 26350-4 24278-4 Motor/Lubricator 26350-5 24278-5 Motor/Lubricator 26350-6 32306 Motor/Lubricator 32295 * Recommended spare parts. ** Also available in NC, p.n.b9640-1 & 20256-1 OIL OUTLET 5/16-24 THREAD FEMALE 5 244 Ø 7 (X2) 169.5 166 146 MAX! MIN 22.5 MAXIMUM STROKE LENGTH FOR MANUAL OPERATION 5A 6 43 7 1 2 3 4 Measurements shown in inches. 130 Accessories Description Part # Line Filter, 1 inch, 25 micron 19850 Line Filter, 3 inch, 25 micron 19848 Pressure Switch, SPST - N.O., 0.8 Bar (12 psi) 26410 Pressure Switch, SPST - N.C., 0.7 Bar (10 psi) 26393 Pressure Gauge, 0-7 Bar (0-100 psi) B5610 5

Maintenance 1. Use only clean and approved lubricant. Check lubricant level daily and refill as needed to maintain proper level in reservoir at all times. Failure to maintain proper lubricant level may result in serious damage to lubricator and machine being lubricated. Before disassembling lubricator to perform routine maintenance, always turn off and disconnect electrical power. 2. Install a 25 micron filter in the main line near the lubricator whenever meter units are used. 3. Replace suction filter annually or as frequently as necessary by following the steps below: a. Remove reservoir by unscrewing 4 screws. If sediment has accumulated inside the reservoir, wipe with clean cloth to remove. b. Remove spring clip and pry out old suction filter element and screen. c. Insert screen and new filter disc (screen first). d. Install spring clip and reservoir. e. Refill with clean lubricant. 4. Incorporate a pressure gauge downstream from the in-line filter to provide visual indication of lubrication cycles. 5. Install a pressure switch downstream from the in-line filter to provide electronic monitoring of lubrication cycles. 6. All tubing, flexible hoses and fittings must be compatible with the lubricant, operating pressure and surrounding environment. Before performing service to lubricator, always turn off and disconnect electrical power. Troubleshooting 6 Symptom Possible Cause Remedy Lubricator does not pump automatically. Motor runs but lubricator does not pump within specified cycle time. Lubricator will not pump when manually operated. Air bubbles in lubricant when discharged from lubricator. Lubricant level switch does not operate properly. 1. Motor not running - poor electrical connection. 1. Check electrical connections to insure power is being supplied to motor. If motor will not run, replace motor. 1. Discharge setting incorrect. 1. Readjust setting refer to lubricant discharge adjustment. 2. Clogged suction filter disc. 2. Replace suction filter disc. 3. Use of non-approved lubricant. 3. Replace suction filter disc and use approved lubricant. 1. Rocker arm near top of cam for piston stroke. 1. Allow motor to run until lubrication cycle is initiated. 2. Discharge setting incorrect. 2. Readjust setting refer to lubricant discharge adjustment. 3. Clogged suction filter disc. 3. Replace suction filter disc. 4. Use of non-approved lubricant. 4. Replace suction filter disc and use approved lubricant. 1. Clogged suction filter disc. 1. Replace suction filter disc. 2. Use of non-approved lubricant. 2. Replace suction filter disc and use approved lubricant. 3. Reservoir low on lubricant. 3. Refill reservoir. 1. Switch contacts reversed. 1. Invert float on level switch stem refer to low lubricant level indication. 2. Switch contact rating exceeded. 2. Replace lubricant level switch assembly.