ZS35 Screw Clamp Terminal Blocks Feed-through

Similar documents
ZS6 Screw Clamp Terminal Blocks Feed-through

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZK6 PI-Spring Terminal Blocks Feed-through

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZK4-PE PI-Spring Terminal Blocks Ground

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS6 Screw Clamp Terminal Blocks Feed-through

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZDP Pluggable Terminal Blocks Feed-through

ZP2.5-PE Spring Terminal Block Ground

ZP2.5-4P Spring Terminal Block Feed-through

DBL distribution blocks 3x1 pole

ZS4-SF1 Screw Clamp Terminal Block

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Electronic overload relays EF205 and EF370

Thermal overload relay TF140DU and TF140DU-V1000

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

MS General Information Extended Product Type: MS

Thermal overload relay TF65 and TF96

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Mini contactors B6, BC6 with 3 pole

Manual motor starter MS116

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Thermal Overload Relays

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Manual motor starter MS132

Manual motor starter magnetic only MO325

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS116

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DX³ RCCBs - ID 4P up to 100 A

AF40... AF96 3-pole contactors Technical data

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starter MS132

Manual motor starter MS132

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Voltage limiting device HVL

Phase + Neutral, neutral on left side

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Surge arrester POLIM-H..SD

TX³ RCCBs 2P up to 100 A

Voltage limiting device HVL

up to 63 A (1 module per pole)

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

ABB i-bus KNX DG/S x DALI-Gateway Basic

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Transcription:

Technical Datasheet SNK609D00 Catalogue Page ZS3 Screw Clamp Terminal Blocks Feed-through Closed terminal block: - No end section needed, - Optimized rigidity, - Perfectly adapted to solar applications: voltage is rated 000 V AC / DC IEC. SNK6004F004 SNK000F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC00498 F0000 Screw Clamp Terminal Blocks 3 mm² 0 AWG 6 mm 0.630 in Spacing Ordering Details Color Grey Blue Orange Grey Blue Orange Type ZS3 ZS3-BL ZS3-OR Order Code SNK600R0000 SNK600R0000 SNK6030R0000 EAN Code 349600 3496004 34960303 Pack (ing) 0 0 0 Weight ( pce) g 3.40 3.40 3.40 Declarations and Certificates CE CB RoHS USR CSA EAC Ex ATEX IECEx BR-Ex e II USR Haz Loc BV RINA DNV ATEX Declaration

Declarations and Certificates CE CE CB CB RoHS RoHS USR USR SND00U0* SND608A0* SND3049F0* SND604A0* CSA CSA SND606A0* EAC Ex EAC Ex ATEX ATEX SND6004A* IECEx IECEx SND600A* BR-Ex e II BR-Ex e II SND604A0* USR Haz Loc USR Haz Loc SND604A0* BV BV SND603A0* RINA RINA SND6088A0* DNV DNV SND608A0* Atex Declaration Atex Declaration SND08C0* Explosive Atmosphere: ATEX Classification Group Category IM II GD Ex eb I/II/IIIC Protection Method Ex e: increased security In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail Wire stripping length IEC 6094- TH 3-., TH 3- Denudage IP0 TH 3-., TH 3- mm 0.669 in NEMA Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 6. mm 0.6 in.9 N.m. N.m ± 0. N.m ± 0.88 N.m Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL94 V0 NF F 60 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter 6... 3 mm² 6... 3 mm² 4... 3 mm² 4 3 mm² A9-B9 IEC 6094- Needle flame testec 606-- Compliant Screw clamp 0... 0 AWG 0... AWG 0... AWG 0 mm 0.394 in Ferrule 4 mm 0. in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²). Technical Datasheet SNK609D00 ABB

Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors 6... 6 mm² 0... 6 AWG Flexible conductors 6... 6 mm² Flexible conductors with twin ferrule 4 0 mm²... 8 AWG Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²) Cross section Rated cross section 3 mm² 0 AWG Maximum Cross section 3 mm² 0 AWG Electrical characteristics Current Rated current A Field and factory wiring Cat. Factory wiring Cat. UL 09 0 A UL 09 0 A CSA-C-. n 8 0 A Maximum Exe current IEC/EN 6009- A Rated short-time withstand current s (Icw) 400 A Short-time withstand current 0. s s 0 s 30 s min 80 A 0 A 8 A A 0 A Rated short-circuit withstand current UL 09 Max. current (4 temperature increase) / Max. cross section (mm²) A Maximum short circuit current (s) 400 A 3 mm² Short Circuit Current Rating (SCCR) SA UL 09 supplement SCCR With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating UL 09 00 ka 0... 0 AWG 600 V J 0 A T 0 A RK 00 A RK 00 A G 60 A CC 30 A Voltage Rated voltage IEC 6094-000 V Rated voltage UL 09 600 V Use Group UL 09 B, C Rated voltage CSA-C-. n 8 600 V Rated voltage Ex e IEC/ EN 6009-693 V Rated impulse withstand voltage IEC 6094-8000 V Dielectric test voltage IEC 6094-00 V Pollution degree IEC 6094-3 Overvoltage category IEC 6094- III ABB Technical Datasheet SNK609D00 3

Temperature range Ambient temperature min/max Storage -... +0 C Installing -... +40 C Service -... +0 C -6... +30 F +3... +04 F -6... +30 F Current Derating curve for continuous service temperature SNK00089F0000 Dissipated power Maximum dissipated power at rated current Maximum dissipated power at maximum Exe current IEC 6094-4 W IEC 6009- Rated power dissipation at an ambient temperature of 3 C - IEC 6094--3 Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068- Compliant Temperature +00 C 96 h IEC 60068-30 Compliant Temperature + C Relative humidity Number of cycles ( cycle = 4h) IEC 60068- Compliant Temperature -40 C 96 h IEC 60068--8 Temperature Relative humidity Corrosion Salt mist IEC 60068- Compliant 96 h Concentration % SO ISO 6988 Compliant 48 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 60068-60 Number of the test method 4 Technical Datasheet SNK609D00 ABB

Vibrations and shocks Sinusoidal vibrations IEC 60068--6 Compliant Frequency range 0... Hz Number of cycles 0 Acceleration 0 m/s² Functional random vibrations IEC 633 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes ZS3 Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. IEC 633 Frequency range Acceleration IEC 633 Acceleration Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB049R06 680 0.3 3 4 6 End Stops Circuit Separators Protecting Covers Protecting Covers Protecting Cover Kits MC8 MC8-YL MC8PA UMH PROCAP8 SAT8 PR3.G PR4 PR PR30 PR3.Z BAZH CS-R CO PL6 KCO JB6- JB6-3 JB6-4 JB6- JB6-0 SNK60000R0000 SNK60004R0000 SNK69999R0000 SNK9006R0000 SNK90063R0000 SNK90066R0000 SNA64800R0300 SNA6800R00 SNA6800R00 SNA30R000 SNA4300R00 SNK9000R0000 SNK90003R0000 SNK900604R0000 SNK9006R0000 SNK90064R0000 SNK9630R0000 SNK96303R0000 SNK96304R0000 SNK9630R0000 SNK9630R0000 0 0 0 0 0 0 0 0 0 0 0 0.00 0.00 4.00 0.0.00 6.00 8.00 9.00 00 38.00 8.00 4.00.0 300.00 4.60 4.80 0.00 6.00.00 8.00 6.60 ABB Technical Datasheet SNK609D00

Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-6968 Chassieu cedex / France Tel. +33 (0)4 Fax +33 (0)4 93 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK609D00 - PDF