MFPA Leipzig GmbH Test, monitoring and certification point for building materials, products and systems

Similar documents
Evidence of Performance Airborne sound insulation of flat roofs

Evidence of performance Reduction of impact sound pressure level by floor coverings

Sound-absorbing spacer Sorp10

UNIGLAS Tender Specifications

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY LAMINATED FLOORING

MFPA Leipzig GmbH Testing, Inspection and Certification Authority for Construction Products and Construction Types

Influence of mounting tube diameter on anemometer output

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Certification Scheme

Assessment Report. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str Idstein

Contact person RISE Date Reference Page. Fredrik Öberg P02435B 1 (5) Building Technology

Tests Report Nº B2014 LACUS IN 11 TG B Laboratory measurements of airborne sound insulation

Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

Report on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

Test-Report. Power determination on PV-Modules at Standard Test Conditions (STC) and PID-Test. PI-Report-Number: a_V2 2012/04/03

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Security steel door dw 62-1 Teckentrup

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION

Tested fasteners for passive structural fire prevention

Full extension concealed slide with soft closing and self-closing

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Test report. About the effect of Lambda System Cleaning Products. No

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

VITLAB Dispenser. Standard Operating Procedure (SOP)

Classification report No K1

Australian Standard. Caravan and light trailer towing components. Part 1: Towbars and towing brackets AS

ZE motor-protective relay Overload monitoring of EEx e motors

Certificate: / 22 March 2013

BRILEX Venting Solutions

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

Deutsche Akkreditierungsstelle GmbH

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Approval of SITEMA Safety Catchers for use as a mechanical restraint device in presses.

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Report Test Report

Sustainable Rail Strategy The Value of Quality

ARMASOUND INDUSTRIAL SYSTEMS THE FIRST SOUND CONTROL SYSTEMS TO MINIMISE THE RISK OF CORROSION UNDER INSULATION (CUI)

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

PTB GLV. Vertical Centrifugal Pump

TYPE-CERTIFICATE DATA SHEET

VARYCONTROL VAV Dual Duct Terminal Boxes

Durch professionelle Datenanalyse clever optimieren sensitive Eis- und Schadenserkennung am Rotorblatt

LEVER OPTIMIZATION FOR TORQUE STANDARD MACHINES

Plastocell Kunststoff GmbH Mühlweg Schifferstadt Phone +49 (0) 62 35/

Instruction Manual. Ex-Time 40 / 50

Fixed Points. 7.i

Ex m Solenoid Operator Type 0519

Gemeinschaft Thermisches Spritzen

Confirmation: / 22 March 2013

Schüco product performance certificate Aluminium sliding systems Schüco ASS 70 FD

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

TEST EQUIPMENT USED. Part , ANSI C63.4, RSS 210

Z from: 1 November 2016

Study of Fuel Economy Standard and Testing Procedure for Motor Vehicles in Thailand

Summary of the project SWD th November Project duration June 2015 to December Edited by

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

DEUTZ lubricating oil Quality Classes DQC DEUTZ Quality Class

Instruction manual. CSV 402 caravan power supply. Table of contents

weinor can hold you the safe, fast way to fix it properly

TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies. Test Report

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

Design and application

TEST METHODS CONCERNING TRANSPORT EQUIPMENT

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

STOREPARKER SERIES STOREPARKER N2503 THE DEPENDENT PARKING SYSTEM ON 3 LEVELS WITHOUT PIT DEPENDENT PARKING SYSTEMS

High Voltage Holiday Detectors & Accessories for Coatings, Linings and Wrappings.

Gas Turbine Aircraft Engines

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

National comparison on verification of fuel dispensers

OPTIFLUX 2000 Quick Start

Industry 4.0 Is Unthinkable Without Calibration!

VIBRATION AND MECHANICAL SHOCK TEST REPORT

Your partner for. e-mobility. Future-proof drivetrain testing for electric and hybrid transmissions.

Pendulum Impact Tester PSd 50

Standard Elastomeric Bearings

CERTIFICATE of Product Conformity (QAL1 )

RUBBERTITE. Technical Data Sheet Issue:

ISO INTERNATIONAL STANDARD. Measurement of noise emitted by accelerating road vehicles Engineering method Part 2: L category

Price List 2013 In-House Repairs and Calibration

Vertical Tensile Machine

ELVI-System. Elevator Inspection System 2.0. Non destructive elevator testing

Accreditation. Deutsche Akkreditierungsstelle GmbH hereby confirms that the testing laboratory

Transcription:

MFPA Leipzig GmbH Test, monitoring and certification point for building materials, products and systems Business Unit IV Construction Physics Prof. Dr.-Ing. habil. Peter Bauer Work group 4.2 Noise Protection Dipl.-Phys. D. Sprinz Phone +49 (0) 341-6582-115 sprinz@mfpa-leipzig.de VMPA certified test site to DIN 4109 D. Erler, B. Sc. VMPA-SPG-129-97-SN Phone +49 (0) 341-6582-162 Test Site acc. to 29b BlmSchG for Noise d.erler@mfpa-leipzig.de Test report No. PB 4.2/12-184-7 from 03 November2017. Duplicate Object: Measurement of airborne sound insulation to DIN EN ISO 10140-2 VSG glazing with a designation Muster "17-StB-064-14" Contracting company: Folienwerk Wolfen GmbH Guardianstraße 4 06766 Bitterfeld-Wolfen Contract date: 06.09.2017 Test data: 17.10.2017 Personnel: D. Erler, B. Sc. Dipl.-Phys. D. Sprinz This test report consist of 6 pages and 2 appendices. This report may only be reproduced in full. A publication even excerpts requires prior written permission from MFPA Leipzig GmbH. The written German form is the legally binding form with original signatures of the drawing approver. The general business terms and conditions of MFPA Leipzig GmbH apply.,.--_-2,---...- ffli----iget DAkkS Certified test lab accredited by DAkkS GmbH to DIN EN ISO/IEC 17025 akkreditiertes Society of materials research and test institute for the Building industry Leipzig mbh (MFPA Leipzig GmbH),----5-----,Zhc German Location: Hans-Weigel-Str. 2b 04319 Leipzig/Germany Accreditationn site Executive director Prof. Dr.-Ing. Frank Dehn D,PL-11021-01-00 Comm. register Amtsgericht Leipzig HRB 17719 According to regional building ordinance (SAC 02) VAT No.: DE 813200649 anerkannte To building product unded regulation (NB 0800) notified Tel.: +49 (0) 341-6582-0 KM point. Fax: +49 (0) 341-6582-135

Constructions physics from 03. November 2017 Page 2 from 6 1. Scope of work A VSG glazing with the designation "sample 17-StB-064-14" from the contracting company Folienwerk Wolfen GmbH Guardianstraße 4 06766 Bitterfeld-Wolfen Should undergo airborne sound insulation measurement to DIN EN ISO 10140-2 in a MFPA Leipzig GmbH test bench and analysed according to DIN EN ISO 717-1. 2. Test objects and test attachments The glazing to be tested With the designation "sample 17-StB-064-14" Outer dimensions (W x H): 1230 mm x 1480 mm Was delivered on 08.09.2017 by the contracting company of MFPA Leipzig and was integrated into the test opening in the test bench of MFPA Leipzig by specialists of MFPA Leipzig. The test date of the test object is given on the cover page of this report and was done in the test bench after 24 hours of acclimatisation time for the glazing. Set up of the tested glazing: Laminated glass 44.2: 4 mm Float 0.76 mm Evguard - laminated foil 4 mm Float The aforementioned details about item designations / numbers of test objects and components of the test objects are details from the contracting company. Integration of the tested windows in the test bench: The VSG glazing has been integrated in an pre-assembled frame made of wooden slats by specialists from MFPA Leipzig and inserted into the test opening. On both sides of the test component there wre different niche depths in a ratio of 2:1. The seal between the test bench and test object and the frame was done with elastic sealant of type Perennator TX 2001 S grey.

Construction physics from 03. November 2017 Page 3 of 6 Thickness of the glazing determined by measurements of testing institute: (from outside to inside, each in the centre and edge of the pane) 4 mm float / 0.8 mm foil / 4 mm float 8.8 mm total thickness Outer dimensions of the glazing: Height x width = 1480 mm x 1230 mm (determined by measurement of the testing institute on the day of testing) Total weight of the glazing: Total weight: 35.9 kg (determined by measurement of the testing institute on the day of testing) The area related weight, regarding the outer dimensions of the glazing, is shown in Appendix 1. 3. Test bench The test bench complies with the requirements of DIN EN ISO 10140-5. There is a continuous separating groove between both sand-lime brickwork and concrete echo spaces (sending and receiving spaces) of the test bench to suppress edge transfer The common separating wall wiht the integration opening for the test component is made and plastered in a two-shell sand-line brickwork 2 x 175 mm, raw density class 2.0. In the 50 mm wide continuous separating groove between the brickwork shells there are densely packed mineral wool panels. Other walls of the sending and receiving spaces are built as sand-lime brickwork, raw density class 2.0 and plastered on both sides. The test spaces have a floorplan with one right angle and three irregular angles. The lower ceiling is140 mm steel reinforced concrete, the upper ceiling is 200 mm steel reinforced concrete. The test area S of the test opening was 1.88 m 2 (1.50 m high x 1.25 m wide). The sender space volumes and the receiving room volumes are detailed in Appendix 1. The air temperatures and the relative humidity in the test spaces as well as the statics pressure at the time of measurement are detailed in Appendix 1. Before starting the test, the pane temperatures of the glazing in the sending and receiving spaces were measured. In both cases the results correspond to the air temperatures in the test spaces according to Appendix 1.

Construction physics from 03. November 2017 Page 4 of 6 4. Test procedure Measurement of airborne sound insulation was done according to: DIN EN ISO 10140-2, Acoustics, measurement of sound insulation of components in a test bench, Part 2: Measurement of airborne sound insulation, version December 2010 Airborne sound insulation calculations were done according to: DIN EN ISO 717-1, Acoustics, Analysis of sound insulation in buildings and of components, Part 1: Airborne sound insulation, version June 2013 Determination of the sound insulation dimension R was done with broadband noise in Terz frequency ranges 50 5000 Hz using the available test area. The sound insulation dimension R results from the following equation: wherein: R = L i - L2 + 10 Ig ( s A) in db L1 L2 average noise leve in the sender area in db average noise level in the receiver area in db S Area of the test body in m 2 A equivalent absorption area in the receiver area in m 2 The equivalent absorbtion area in the receiver area was determined in the receiver space based on 12 echo time measurements terzwise according to the following equation: wherein: V A = 0,16 x = 1 Volume of the receiving space in m 3 T Echo time in the receiver area in s Due to the maximum insulation of the test bench of 76 db, the measurements were not influenced by edge transfer. The scope and execution of measurements correspond to the basics of the working group of the building control recognised noise inspection sites in agreement with NABau building subcomittee 00.71.02. A gas analysis of the intermediate space of the pane was not part of the contract.

Construction physics from 03. November 2017 Page 5 of 6 5. Instrumentation The instrumentation listed in Table 1 were used: Tabelle 1: Instrumentation used Device Typ e Manufacturer Real-time analyzer with noise generator 840 Norsonic Free-field microphone 1220 Norsonic Pre-amplifier 1201 Norsonic Calibrator 4231 B & K Power amplifier 235 Norsonic Loudspeaker combination (Dodekaeder) 229 Norsonic Microphone swivel system, remote control 231, 252, 253 Norsonic The instruments were calibrated regularly, the measurement chain was calibrated before and after each measurement. The MFPA Leipzig regularly participates in the comparative measurements for test sites of group I (qualification lab) of the Physikalisch Technischen Bundesanstalt (PTB) Braunschweig (most recently in 2016) and is entered as a test siste in the "Directory of test, monitoring and certification sites to the regional construction ordinance " of the German Institute for Construction Technology DIBt under the eading "SAC 02". MFPA Leipzig is accredited by DAkkS GmbH as a test lab according to DIN EN ISO/IEC 17025. 6. Measurement results In the following Table 2, the measurement results of the analysed sound insulation dimension R w is given according to DIN EN ISO 717-1 for a frequency range of 100 to 3150 Hz, each with the spectrum adjustment values. Table 2: Test results Test set up Glasing with the designation Bezeichnung "Sample17-StB-064-14" Analysed Spectrum adjustment value sound insul. value Test value Co5- C50-0 100 Ctr.50- Ctr.50 Ctr.100 Rw (C; C. ) 3150 5000-5000 3150-5000 -5000 [db] See Appendix 37 (-2 ; -4) -2-2 -2-5 -5-4 1 Remarks: the spectrum adjustment values C and Ct, to DIN EN ISO 717-1 should be adjusted to the analysed sound insulation value Rw to the A spectrum and traffic noise at high speed (C value) and city traffic noise (Ctr value). They are only given for information; at this time public law in the Federal Republic of German applies DIN 4109 as the basis for analysis without spectrum adjustment values.

Construction physics from 03. November 2017 Page 6 of 6 The graphical image of the R-value depending on frequency can be seen in Appendix 1. Based on DIN EN ISO 717-1, the sound insulation value measured in the test bench and analysed is; R w (in 1/10 db with measurement uncertainty): R w = 37.0 db ± 1.2 db For the given measurement uncertainty there is an average standard deviation for test bench measurements according to DIN EN ISO 12999-1:2014-09. 7. Information about the test results For VSG or GH panes there is a dependency of sound insulation from the ambient temperature. For lower temperatures than the test temperature a reduction in noise insulation may occur. The values determined are test values that were measured under lab conditions. The results of tests exclusively refer to the described test objects and not to the population. This document doesn not replace any proof of conformity or usability in regards to building ordinaces (national / European). Leipzig, 03. November 2017 Prof. Dr.-Ing. P. Bauer Dipl.-Ing. V. Fenske D: Erler; B. Sc. Business Unit Director Deputy Work Group Manager Test Engineer Dipl.-Phys. D. Sprinz Work Group Manager

MFPA MFPA Leipzig GmbH No. PB 4.2/12-184-7 Appendix 1 Construction Physics from 03. November 2017 Page 1 of 1 Sound insumation measurement to ISO 10140-2 Measurement of airborne soiund insulation of components in a test bench Contracting company Manufacturer: Test object integrated into: Test space designation: Product designation: Test object set up: Folienwerk Wolfen GmbH, Guardianstraße 4, D-06766 Bitterfeld-Wolfen Auftraggeber MFPA Leipzig GmbH B F.02 / B F.01 VSG glazing with designation "Sample 17-StB-064-14" Outer dimensions (W x H): 1230 mm x 1480 mm Pane set up: Laminated glass 44.2-4 mm Float - 0.76 mm Evguard - Laminated - 4 mm foil float Testing date: 17.10.2017 Area S test object: 1.88m' Area related weight: 19.7 kg/m' Temperature SR / ER: 21 / 21 C Rel. humidity SR / ER: 48 / 47 % Static pressure: 100 kpa Volume SR / ER: 78.5 / 57,. m' (SR = Sender space; ER = receiver space) The frequency range corresponding to the curve of the displaced reference value (ISO 717-1) Frequenz f [Hz] R Terz [db] 50 26.9 63 33.0 80 17.4 100 20.6 125 24.1 150 25.2 200 27.8 250 27.7 315 29.8 400 32.6 500 34.3 630 35.7 800 37.1 1000 38.2 V50 39.7 1500 41.1 2000 40.7 2500 37.7 3150 31.7 4000 36.4 5000 39.2 Analysis to ISO 717-1 R w(c ; C tr) = 3 7 ( - 2 ; - 4 ) db The determination was based on test bench M that was obtained in Terz bands. C 50-3150= -2 db C50.-5000-2 Ctr 50-3150= -5 db Ctr 50-5000= -5 db C100-5000,= -2 db db C1r,100.-5000 = -4 db M FPA Leipzig GmbH Noise protection area HSaris-Weigel-Str. 2h 04319 Leipzig Mail

MFPA Leipzig GmbH Construction physics No. PB 4.2/12-184-7 from 03. November 2017 Appendix 2 Page 1 of 1 Figure A.2.1: tested glazing (sender space side) Figure A.2.2: tested glazing (receiver test side)