Effective June 2016 New Issue

Similar documents
COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Effective March 2015 Supersedes S August 2012

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

Effective May 2017 Supersedes January 2003 (S )

Effective May 2017 Supersedes December 2004 (S )

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

S Voltage Regulators. Contents. QD3 Quik-Drive Voltage Regulator Tap-Changer Manual. Figure 1B. QD3 Tap-changer. Figure 1A. QD3 Tap-changer.

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

Two-way cable interlock kit for Magnum fixed circuit breakers

CCP2-FLR1-21_ flange-rod operating mechanism

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Factory Authorized Mechanism Enhancement (FAME)

3-way multi-family drawout cable interlock kit - type 32 - RF

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Two-way cable interlock kit for Magnum drawout circuit breakers

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

Installation Instructions For Motor Control Center (MCC) Units

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Effective October 2016 Supersedes January 2014 (S )

Instruction Booklet IB E. Contents

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

CM52 Network Protector with Arc Flash Reduction Module

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

ELB ELB

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

O & M Manual for the EATON Generator Ready Loadcenter

FCB-450, LCB-600, MCB-800

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Installation Instructions

Single Post Caliper Brake VC500

DAP-625S and DAP-875S

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

AIR CHAMP PRODUCTS. BD Caliper Brake STANDARD FORM NO. L Y MTY (81) QRO (442)

Straight-Bore Clutch LSCC-32, 44, 54

Installation Manual TWM Performance Short Shift Kit Stage 1 and Stage 2 MazdaSpeed 6

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

LINEAR MOTION CONTROL

Ford Mustang 2013 GT500 Rear Break Install Guide for Mustang GT

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

Installation Instructions

Vacuum Circuit Breaker (Vehicle)

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

38 kv Type VCPW-HD Simple Electrical Ground & Test Device (SEG&TD) lower terminal instruction booklet

Magnum Breaker Remote Racking Device (MRR1000)

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Transcription:

Voltage Regulators MN225035EN Effective June 2016 New Issue COOPER POWER SERIES QD8 Quik-Drive Tap-Changer Switch Assembly Kit 5740785B13 and Switch Neutral Stationary Assembly Kit 5791646A48 Installation Instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY................................... II SAFETY FOR LIFE.........................................................................IV SAFETY INFORMATION....................................................................IV Safety instructions.............................................................................. iv PRODUCT INFORMATION................................................................... 1 Introduction....................................................................................1 Read this manual first............................................................................1 Acceptance and initial inspection...................................................................1 Handling and storage.............................................................................1 Quality standards................................................................................1 Additional information............................................................................1 Parts supplied..................................................................................1 Tools required..................................................................................1 INSTALLATION PROCEDURE................................................................ 2 Removal.......................................................................................2 Reassembly....................................................................................4 PLACING TAP-CHANGER INTO NEUTRAL...................................................... 7 iii

! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv

Product information Introduction Eaton s Cooper Power series QD8 Quik-Drive tap-changer reversing switch movable contact assembly and the reversing switch neutral stationary contact assembly kits and installation instructions provides instructions for removal and replacement of the reversing switch movable contact assembly and reversing switch neutral stationary contact for the polymer model of the QD8 Quik-Drive tap-changer. Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Acceptance and initial inspection Each kit is in good condition when accepted by the carrier for shipment. Upon receipt, inspect the shipping container for signs of damage. Unpack the kit and inspect it thoroughly for damage incurred during shipment. If damaged is discovered, file a claim with the carrier immediately. Handling and storage Be careful during handling and storage of the kit to minimize the possibility of damage. If the kit is to be stored for any length of time prior to installation, provide a clean, dry storage area. Parts supplied Table 1. Switch Assembly Kit Item Part Number Description Qty 1 0740785B13 Switch 1 Table 2. Switch Neutral Stationary Assembly Kit Item Part Number Description 1 0791646A48 Switch Neutral Stationary 2 0800005001Z Jam Nut 3 0892568A02 Belleville Washer Tools required 3/8 inch drive ratchet wrench 3/8 inch drive ratchet extension 1/4 inch socket 7/16 inch socket 9/16 inch socket 3/4 inch deep-well socket 3/32 inch Allen wrench Standard 8-inch long flat-blade screwdriver Torque wrench for in-lbs Loctite 243 Threadlocker Quality standards ISO 9001 Certified Quality Management System Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, contact your representative. Figure 2. neutral stationary contact assembly kit Figure 1. movable contact assembly kit 1

Installation procedure Removal 1. This procedure may be completed without removal of the tap changer from the voltage regulator. Carefully follow the procedures for partially untanking a voltage regulator in Service Information MN225008EN, VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions. Neutral Stationary Assembly Segment Actuator Arm Actuator Arm Nut Bushing Actuator Arm Figure 5. Bushing Bushing Mounting Bolt 4. Using a 7/16" socket wrench, loosen and remove both bushing-mounting bolts. See Figure 5. 5. Remove the bushing from the reversing movable contact shaft. See Figure 6. Figure 3. switch and hardware 2. Using a 9/16" wrench loosen and remove the reversing actuator arm nut. See Figure 3. 3. Lift outward on the reversing actuator arm and remove it from the reversing movable contact bushing. The reversing actuator shaft may be tapped in to allow clearance to remove the arm. See Figures 4 and 5. Actuator Arm Actuator Shaft Bushing Figure 6. Removal of bushing Figure 4. Removal of actuator arm 2

6. Use a 3/32" Allen wrench and a 1/4" socket wrench to loosen and remove the self-locking nuts and logic switch mounting screws. See Figure 7 and Figure 8. 7. After removing the logic switch mounting screws the switches will drop away from the reversing switch movable contact tube and hang by the wires. 8. On the back side of the tap changer contact board, carefully mark the reversing switch leads; photos can be helpful to assist in remembering the arrangement of the connections. See Figure 9. Logic switch hardware Figure 7. logic hardware switch neutral stationary contact leads Screw Nut Figure 9. Loose logic switches 9. Using a 3/4" wrench, remove the nuts and jam nuts holding the leads and copper bars connected to the reversing switch neutral stationary contact and remove the connections. See Figure 9. 10. Use a 3/4" wrench to loosen and remove the nuts and flat washers from both of the reversing neutral stationary contacts on the back of the tap-changer contact panel. See Figure 10. Logic Switch Figure 8. Removal of logic switch Stationary Hardware Figure 10. neutral stationary contact 3

11. Pull the reversing movable contact assembly and the reversing neutral stationary contact forward toward the steel front panel as shown in Figure 11. 14. Remove the reversing actuator shaft from the reversing movable contact assembly and retain for use in the new contact assembly. See Figure 13. Neutral Stationary Assembly Reversible Assembly Actuator Shaft Figure 13. The actuator shaft removed from the reversing movable contact assembly Figure 11. movable and stationary contacts 12. Rotate the reversing movable contact counter clockwise until the movable contact assembly disengages from the reversing neutral stationary contact and remove it from the tap-changer. See Figure 12. 13. Remove the reversing neutral stationary contact from the tap-changer contact panel. Reassembly 15. Insert the reversing actuator shaft into the new reversing movable contact assembly. See Figure 13. 16. Partially install the reversing neutral stationary contact into the mounting holes as shown in Figure 14. 17. Place the new reversing movable contact into the mounting slot in the tap-changer front panel, aligning the movable contact assembly with the reversing neutral stationary contact. See Figure 14. Assembly Assembly Mounting Slot Figure 12. Rotating the reversing movable contact Figure 14. Reinstalling reversing movable contact 4

18. Insert a standard flat screwdriver between the middle and top button contacts on the reversing movable contact assembly and twist to separate. Line up the movable and stationary contacts and rotate the movable contact assembly clockwise over the reversing stationary contact. See Figure 15. 20. Slide the stationary and movable contact assembly toward the contact panel. Align the movable contact assembly so that the reversing movable tube aligns with and goes through the hole in the contact panel. At this point the stationary contact and movable contact should be fully engaged with the contact panel. See Figure 17. Tube Main Stationary Board Figure 15. Positioning reversing movable contacts 19. Continue to reposition the screwdriver, separate the button contacts and rotate the reversing movable contact assembly until the middle button contact is fully engaged in the center of the reversing stationary contact blade. See Figure 16. Figure 17. Aligning with main contact board 21. Place a Belleville washer and nut over each of the reversing neutral stationary contact studs. The cupped side of the washer must face in toward the contact board. Tighten to a torque of 180 192 in-lbs (20.3 21.7 Nm). See Figure 18. Neutral Stationary Assembly Figure 16. Engaging contacts Figure 18. Reinstalling neutral stationary and hardware 22. Reinstall the copper bars and leads to the positions noted in step 7 and secure with the hardware removed earlier. Tighten the nuts to a torque of 180 192 in-lbs (20.3 21.7 Nm). 5

23. Place the mounting hardware onto the reversing logic switches and fasten to the tap-changer front plate. Use a 3/32" Allen wrench and 1/4" socket wrench to tighten the nuts to a torque of 4 5 in-lbs (0.5 0.6 Nm). See Figure 19. Logic Switches 4-40 Lock Nut 25. Place the reversing segment arm onto the reversing actuator shaft. Align the square portion of the shaft with the square hole in the arm. If needed, place a screwdriver through the movable contact tube and push the shaft forward while seating the arm over the shaft. It may be necessary to rotate the movable contact assembly slightly to align the shaft and hole. See Figure 21 and Figure 22. Segment Arm 4-40x1.25 Allen Screws Shaft Figure 21. Installing reversing segment arm Figure 19. Reinstalling logic switches 24. Apply Loctite 243 Threadlocker to the two 1/4-28 bolts. Using the bolts and a 7/16" wrench, fasten the reversing movable bushing to the front of the tap-changer. Tighten the bolts to a torque of 30 40 in-lbs (3.4 4.5 Nm). See Figure 20. Bushing Hardware Figure 22. Positioning the reversing movable with the bushing Figure 20. Reinstalling bushing 6

26. Place the self-locking nut onto the reversing segment shaft and tighten with a 9/16" wrench. The nut should be tightened to a torque of 180 to 192 in-lbs (20.3 to 21.7 Nm). See Figure 23. Placing tap-changer into neutral 1. Place a 3/8" socket with extension and ratchet on the output shaft of the motor; rotate the motor until the contacts and other components are aligned in the neutral position. See Figure 24. Hardware Figure 23. Fastening reversing segment 27. Once the work has been completed place the tap-changer in the neutral position. Figure 24. Rotating the motor shaft 2. Confirm that the regulator is in the neutral position: A. Main movable contacts are located on the neutral stationary contact, which is located at the 11 o clock position. See Figure 25. Neutral Stationary Main s Figure 25. Neutral stationary contact position for main movable contacts 7

B. The reversing movable contact is located on the reversing neutral stationary contact. See Figure 26. D. The neutral switch will be depressed with the switch lever. See Figure 28. Neutral Stationary Switch Lever Figure 26. Neutral position for reversing movable C. The pinion cam is pointing to the right over the holding switch actuator. See Figure 27. Neutral Switch Figure 28. Neutral switch is depressed Holding Switch Actuator Pinion Cam Figure 27. Neutral position for position indicator pinion cam and holding switch Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com! SAFETY FOR LIFE Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No. MN225035EN June 2016 5740785B13 Rev 0 5791646A48 Rev 0 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton's Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.