www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

Similar documents
www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Substation Transformers

Substation Transformers

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

C. System Design and Performance Requirements

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

Unit Substation Transformers 5 and 15 KV Class

RELIABLE POWER COOPER POWER SYSTEMS. Transformer Products Group FROM

NEW Solutions for Underground System Growth

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Standard Features and Accessories

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Distribution transformers Efficiency over life-cycle

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

Distribution Transformers

SWITCHGEAR DIVISION PRODUCT PROFILES

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Distribution Transformers

Prime Power Energie Systems Inc.

Underground Distribution Switchgear

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

C1000 Series Automatic Cap Bank

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

Submersible Vacuum Fault Interrupters

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

Design Standard. Purpose: Design Standard:

Single-Phase Step Voltage Regulators

GROUP D. Switch & Protective device.

Single-phase pad-mounted step voltage regulator

HPS EnduraCoil. Cast Resin Transformer

CAST RESIN TRANSFORMERS

Three-Phase Pole Mounted Recloser

Underground Distribution Switchgear

SECTION PADMOUNT TRANSFORMER - OIL FILLED

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Single-phase step voltage regulators

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

www. ElectricalPartManuals. com Westinghouse Type RSL Rectangular Coil Core Form Liquid Immersed Substation Transformers

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Technical Specification for Pole Mounted Capacitor Rack

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Figure 1. Two and Three-phase MagneX.

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

www. ElectricalPartManuals. com Westinghouse PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 750 Thru 2500 Kva

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Kuhlman Electric Corporation Volt Instrument Transformers

100 / 110 DRYWELL FUSE SPECIFICATION

Underground Distribution Switchgear

SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ

Proudly Made In America

SPECIFICATION FOR THREE PHASE PAD-MOUNT DISTRIBUTION TRANSFORMERS

University of Houston Master Construction Specifications Insert Project Name

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Midwest Dry Type Transformers

Chapter 6 Generator-Voltage System

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

A. Submit manufacturer's literature and technical data before starting work.

AIR CORE REACTORS. Phoenix Electric Corporation

Switchgear Skid, C1192

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

H1 H2 H3 X0 X1 X2 X3

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

A 1.2 kv class externally removable secondary bushing

ABB Transformadores para aplicaciones solares y eolicas

Howard Industries. Single-Phase Step

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

NXPLUS C Single busbar. Maintenance-free for lifetime

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Publication No.: PSG

Typical Specification

Outdoor Power Transmission & Distribution

Power System Solutions (PSS)

INSTRUCTION MANUAL #103

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

Transcription:

Substation Transformers Primary or Secondary Unit GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet exact customer specifications. Flexibility in design, combined with the highest quality manufacturing processes and equipment, enable Cooper Power Systems to provide a product optimized to the customer s requirements. All units meet applicable ANSI, NEMA, IEEE Standards and NEC and CEA specifications. Unit substation transformers are available with enclosed sidewallmounted bushings for connections to primary and/or secondary switchgear. Substation transformers are made with a wide range of core steels and winding conductors to meet total owning cost or material requirements. Flexible core and tank construction enables your dimensional requirements to be met. Cooper Power Systems transformers are available with standard electrical grade mineral insulating oil or other dielectric coolants manufactured by Cooper Power Systems. Unit substation transformers intended for indoor use are filled with R-Temp fluid, a less-flammable, high molecular weight hydrocarbon with a flawless fire safety record. Electrical codes recognize the advantages of using R-Temp fluid both indoors and outdoors for fire sensitive applications. R-Temp fluid-filled units meet OSHA and Section 450-23,996 NEC requirements. Transformers intended for outdoor applications may be filled with R-Temp fluid or normally formulated hydro-refined mineral oil. March 998 Supersedes /94 Printed in U.S.A. Electrical Apparatus 20-5 Figure. Secondary unit substation transformer equipped with transition flange and full length cabinet.

Primary or Secondary Unit LIQUID TEMPERATURE GAUGE For easy monitoring of oil temperature. Available with multiple alarm contacts. FLANGE Allows connection to high-voltage gear. Figure 2. Secondary unit substation transformer with standard features and optional accessories. 2 DE-ENERGIZED TAP CHANGER Tap changer is externally operable. COOLING RADIATORS Detachable, bolt-on radiators with valves are available. BASE Suitable for skidding, rolling and jacking. RAPID PRESSURE RISE RELAY Monitors rapid rise of internal pressure. GROUND PADS Non-corrosive, stainless steel ground pads on the front and rear. CONTROL BOX Weather-resistant, dust-proof, NEMA-rated control box for controls and alarm contacts. PRESSURE/VACUUM GAUGE Available with bleeder valve. PRESSURE RELIEF DEVICE Activated by excessive tank pressure. DRAIN/FILTERING VALVE The combination drain and filtering valve contains a fluid sampling device. TANK LIFTING LUGS Lift hooks welded to the tank at each corner for lifting. FILLING/FILTER PRESS CONNECTION One-inch upper filling and filter press connection. FULL LENGTH CABINET LIQUID LEVEL GAUGE Monitors oil level. Available with alarm contacts. NAMEPLATE Laser-scribed anodized aluminum.

STANDARD FEATURES De-energized tap changer, externally operable Extra-heavy, welded-in-place lifting lugs and jack pads Sidewall mounted high-voltage porcelain bushings Sidewall mounted low-voltage molded epoxy bushings with NEMA six-hole spades Tank bases designed to allow skidding or rolling in any direction One-inch upper filling plug with filter press connection One-inch combination drain/filtering valve with sampling device Available in ANSI #6 Light Gray or ANSI #70 Sky Gray Tank interior is painted light gray, improving visibility for field inspection and servicing Pressure test connection Dial-type thermometer Dial-type liquid level gauge Pressure vacuum gauge Stainless steel grounding pads Laser-scribed anodized aluminum nameplate Cooling radiators are welded directly to the tank Standard grade mineral insulating oil (for outdoor applications) Pressure relief device OPTIONAL ACCESSORIES Primary and secondary termination enclosure options Throat Flange Top- or bottom-entry air terminal chamber Top- or bottom-entry full length cabinet Pressure vacuum bleeder valve Cover mounted pressure relief device (for oil-cooled units; standard with R-Temp units) Detachable, bolt-on radiators with valves Monitoring devices Dial-type thermometer with alarm contacts (standard with FA Fan Package) Liquid level gauge with alarm contacts Pressure/vacuum gauge with alarm contacts Cover mounted pressure relief device with alarm contacts Rapid pressure rise relay Optional seal-in panel Winding temperature indicator with alarm contacts R-Temp less-flammable fluid and other environmentally desirable fluid options Primary air disconnect switch Forced air fan control package Package includes fans, NEMA 3R control box, fan controls, dial-type thermometer with alarm contacts. Nitrogen blanket with purge valves (3 psi) Control box PROTECTION OPTIONS Surge arresters 20-5 Distribution, intermediate, or station class Kyle Vacuum Fault Interrupter (VFI) 3

Primary or Secondary Unit ELECTRICAL DATA TABLE Three-phase, Single Temperature kva Ratings TABLE 2 Percent Impedance Voltage TABLE 3 Audible Sound Levels 4 Three-phase kva Self-cooled and forced-air cooled with 65 C temperature rise 65 C Rise 65 C Rise OA OA/FA 500 575 750 862 000 +5% 50 500 725 2000 2300 2500 325 3750 4687 5000 +25% 6250 7500 9375 0000 2500 kv BIL Low Voltage Class < 2400 V 2400 V 45-50 5.75 2 6.50 3 200 7.25 7.00 250 7.75 7.50 The standard tolerance is ± 7.5%. 2 Option for 6.75% is available. 3 Option for 5.50% is available. Self-cooled, Two Winding kva Rating NEMA Average db, OA db, FA 500 56 67 50-700 57 67 70-000 58 67 00-500 60 67 50-2000 6 67 200-2500 62 67 250-3000 63 67 300-4000 64 67 400-5000 65 67 500-6000 66 68 600-7500 67 70 750-0000 68 7 TABLE 4 Three-phase, Dual Temperature kva Ratings Three-phase kva Self-cooled and forced-air cooled with dual rated 55/65 C temperature rise 55 C Rise 65 C Rise 55 C Rise 65 C Rise OA 0A OA/FA OA/FA 500 560 575 644 750 840 862 965 000 20 50 288 500 680 725 932 2000 2240 2300 2576 2500 +2% 2800 325 3500 3750 4200 4687 5250 5000 5600 6750 7000 7500 8400 9375 0500 0000 200 2500 4000 TABLE 5 Insulation Test Levels kv Class Induced Test kv BIL Applied Test 80 or 400 Hz-7200 Cycle Distribution Power 60 Hz (kv).2 30 45 0 2.5 45 60 5 5.0 60 75 9 8.7 TWICE 75 95 26 5.0 RATED 95 0 34 25.0 (Grd Y Only) VOLTAGE 25 50 40 25.0 50 50 50 34.5 (Grd Y Only) 25 50 50 34.5 50 200 70 46.0 200 250 95 TABLE 6 Temperature Rise Ratings 0-3300 feet (0-000 meters) Standard Optional Unit Rating 65 C 55/65 C Ambient Temperature Max. 40 C 40 C Ambient Temperature 24 Hour Av. 30 C 30 C Temperature Rise Winding 65 C 55 C Temperature Rise Hotspot 80 C 65 C Average Rise by resistance. Refer to NEMA Standards TRI; ANSI Standard C57.2.00. Note: Derate kva by 0.4% for each 00 M (330 ft.) that the altitude is above 000 M (3300 ft.).

A D C 55" H3 H2 H Figure 3. High-voltage left (Segment 2) shown. High-voltage right (segment 4) also available. 2 3 4 ANSI segment designation TOP VIEW B ELEVATION X3 X2 X X0 8" 55" TABLE 7 Oil Filled Aluminum Windings 55/65 C Rise 20-5 Base Dimensions Drawing Dimensions Approx. (in.) (in.) Total kva Gallons Weight (Ibs.) Width Depth A B C D Of Fluid (With Fluid) 500 5 35 69 50 40 59 335 6,300 750 56 36 69 55 36 56 355 7,300 000 58 36 69 57 42 62 370 8,200 500 54 36 78 53 54 75 400 9,800 2000 57 38 78 56 55 09 455 2,000 2500 68 40 78 67 50 99 595 4,680 >2500 * Consult Factory Representative Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact Cooper Power Systems for exact dimensions. TABLE 8 R-Temp Filled Aluminum Windings 55/65 C Rise Base Dimensions Drawing Dimensions Approx. (in.) (in.) Total kva Gallons Weight (Ibs.) Width Depth A B C D Of Fluid (With Fluid) 500 5 35 69 50 40 59 325 6,300 750 56 36 69 55 42 62 355 7,600 000 58 36 69 57 42 84 375 8,400 500 56 36 78 55 62 83 425 0,800 2000 60 40 78 59 56 530 3,500 2500 68 40 78 67 58 5 620 6,300 >2500 * Consult Factory Representative Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact Cooper Power Systems for exact dimensions. TABLE 9 Oil Filled Copper Windings 55/65 C Rise Base Dimensions Drawing Dimensions Approx. (in.) (in.) Total kva Gallons Weight (Ibs.) Width Depth A B C D Of Fluid (With Fluid) 500 5 34 69 50 39 59 320 5,500 750 55 38 69 54 39 60 375 7,500 000 59 38 69 58 45 66 390 8,750 500 5 40 78 50 56 78 435,000 2000 59 38 78 58 57 3 475 3,250 2500 59 38 78 58 57 3 500 4,500 >2500 * Consult Factory Representative Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact Cooper Power Systems for exact dimensions. TABLE 0 R-Temp Filled Copper Windings 55/65 C Rise Base Dimensions Drawing Dimensions Approx. (in.) (in.) Total kva Gallons Weight (Ibs.) Width Depth A B C D Of Fluid (With Fluid) 500 47 34 69 46 39 59 30 5,250 750 55 34 69 54 39 59 350 6,750 000 55 35 69 54 40 78 350 8,000 500 59 36 78 58 5 02 450,500 2000 59 36 84 58 59 8 50 3,500 2500 63 38 84 62 60 20 550 5,500 >2500 * Consult Factory Representative Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact Cooper Power Systems for exact dimensions. 5

Primary or Secondary Unit Figure 4. Throat. 6 4" BUSHING 9" 8" 9" Ø 0.50" 2 HOLES 8" 22" 0" 24" 38" 34" BUSHINGS Figure 5. Air terminal chamber-bottom entry. BUSHING 8" 22" 0" 55" Figure 6. Full length cabinet-bottom entry. 8" 9" 9" 9" 9" 34" 38.3" 2" (Typ.) 5" 20" FRONT VIEW (with Lift-Off Front Panel) 38.3" FRONT VIEW (with Lift-Off Front Panel) 4" Figure 7. Flange. BUSHING Figure 8. Air terminal chamber-top entry. BUSHING 8" 22" 8" 22" 0.5" 0.5" 42" 0.5" 0.5" 24" 0" 24 " 55" Figure 9. Full length cabinet-top entry. 34" 38" 34" BUSHINGS 8" Ø 0.50" 9" 9" 9" 9" 6 HOLES 36" 38.3" FRONT VIEW (with Lift-Off Front Panel) 38.3" 2" (TYP.) 40" 44" FRONT VIEW (with Lift-Off Front Panel)

CONSTRUCTION Core The three-legged, step-lap mitered core construction is manufactured using a high-quality cutting machine. For maximum efficiency, cores are precisely stacked, virtually eliminating gaps in the corner joints. Five-legged wound core or shell-type triplex designs are used for wye-wye connected transformers, and other special transformer designs. Cores are manufactured with precision cut, burr-free, grain-oriented silicon steel. Many grades of core steel are available for optimizing core loss efficiency. Coils Substation transformers feature a rectangular coil configuration with wire-wound, high-voltage primaries and sheet-wound secondaries. The design minimizes axial stress developed by short circuits and provides for magnetic balancing of tap connections. Coils are wound using the highest quality winding machines providing exacting tension control and conductor placement for superior short-circuit strength and maximum efficiency. Extra mechanical strength is provided by diamond pattern, epoxy coated paper insulation, used throughout the coil, with additional epoxy at heavy stress points. The diamond pattern distribution of the epoxy and carefully arranged ducts, provide a network of passages through which cooling fluid can freely circulate. Coil assemblies are heat-cured under calculated hydraulic pressure to ensure performance against short-circuit forces. Core and Coil Assemblies Substation transformer core and coil assemblies are braced with heavy heavy steel end plates to prevent the rectangular coil from distorting under fault conditions. Plates are clamped in place using presses, and welded or bolted to form a solid core and coil assembly. Tanks Transformer tanks are designed for high strength, and ease of handling, installation, and maintenance. Tanks are welded using precision-cut, hotrolled, pickled and oiled steel. They are sealed to protect the insulating fluid and other internal components. Transformer tanks are pressure-tested to withstand 7 psig without permanent distortion and 5 psig without rupture. Tank Finish An advanced multi-stage finishing process exceeds ANSI C57.2.28 standards. The eight-state pretreatment process assures coating adhesion and retards corrosion. It converts tank surfaces to a nonmetallic, water insoluble iron phosphate coating. The three-step, epoxy primer (E-coat) provides a barrier against moisture, salt and corrosives. The electrostaticallyapplied, oven-cured polyester power coat (P-coat) enhances resistance to abrasion and impact. A urethane final coat seals and adds ultraviolet protection. Vacuum Processing Transformers are dried and filled with filtered insulating fluid under vacuum, while secondary windings are energized. Coils are heated to drive out moisture, ensuring maximum penetration of fluid into the coil insulation system. Special attention to moisture removal is the major reason for Cooper s track record of superior reliability and service life. Cooling System Oil-Air (OA) cooling is provided with transformers rated 500 kva. A choice of OA-FFA (Future Forced Air) or OA-FA (Forced Air) cooling is provided with units rated 750 kva and above. Insulating Fluid Cooper Power Systems transformers are available with standard electrical grade mineral insulating oil or other dielectric coolants manufactured by Cooper Power Systems. The highly refined oil is tested and degassed to assure a chemically inert product with minimal acid ions. Special additives minimize oxygen absorption and inhibit oxidation. To ensure high dielectric strength, the oil is retested for dryness and dielectric strength, refiltered, heated, dried, and stored under vacuum before being added to the completed transformer. R-Temp fluid, manufactured by Cooper Power Systems under strict quality control for optimum transformer cooling characteristics, provides higher dielectric strength than mineral oil. The special formulation is less flammable as defined by the National Electric Safety Code, as well as non-toxic and biodegradable. Envirotemp FR3 fluid, the fluid used in Envirotran transformers is a fire resistant, natural ester-based fluid. Envirotemp FR3 fluid offers the advantage of a seed oil-based dielectric coolant with food grade additives, in addition to increased fire safety when compared to mineral oil. R-Temp and Envirotemp FR3 fluid can be used in a substation transformer next to buildings or inside buildings with suitable containment provisions. SUBSTATION VFI TRANSFORMER 20-5 The VFI transformer combines a conventional Cooper Power Systems distribution transformer with the proven Kyle Vacuum Fault Interrupter (VFI). This combination provides both voltage transformation and transformer overcurrent protection in one space saving, money saving package. The substation VFI transformer with transformer protection protects the transformer and provides proper coordination with upstream protective devices. When a transformer fault or overload condition occurs, the VFI breaker trips and isolates the transformer. The three-phase VFI breaker has independent single-phase initiation, but is three-phase mechanically gang-tripped. A trip signal on any phase will open all three phases. This feature eliminates single-phasing of three-phase loads. It also enables the VFI breaker to be used as a threephase loadbreak switch. Because the VFI breaker is resettable, restoring three-phase service is faster and easier. R-TRAN FM APPROVED TRANSFORMER Cooper Power Systems R-Tran Transformer is FM Approved for indoor locations. Factory Mutual Research Corporation s approval of the R-Tran transformer line makes it easy to comply and verify compliance with the 996 National Electrical Code (NEC ) section 450-23, Less- Flammable Liquid-Filled Transformer Requirements for both indoor and outdoor locations. 7

Primary or Secondary Unit FM Approved R-Tran transformers offer the user the benefit of a transformer that can be easily specified to comply with NEC, and makes FM Safety Data Sheet compliance simpler, while also providing maximum safety and flexibility for both indoor and outdoor installations. Because the FM Approved logo is readily visible on the transformer and its nameplate, NEC compliance is now easily verifiable by the inspector. Substation R-Tran FM Approved transformers from Cooper Power Systems are manufactured under strict compliance with FMRC Standard 3990, and are filled with FM Approved R-Temp fire-resistant dielectric coolant. Primary Air Disconnect Switch Provides economical, visible disconnect primary loadbreak switching. Fully coordinated and packaged with the transformer by Cooper Power Systems. Meets IEEE/ANSI C37.20.3, NEMA SG-5 and related standards. Standard features Switch Three-pole, two-position, gang-operated air interrupter; unfused Standard ratings: 600 A continuous and loadbreak; 40 ka fault close and momentary 5 kv (60 kv BIL) or 5 kv (95 kv BIL) Enclosure Standardized modular selfsupporting, bolted design Mechanical safety interlock prevents access when switch is closed or closing of switch when door is open. Optional Features 200 A continuous and load break current rating; 6 ka fault close and momentary. Requires 200 A copper bus option. Key interlocks (single cylinder) for interlocking primary switch with secondary main circuit protective device. Auxiliary switch for remote indication of primary switch position Where high interrupting ratings and short-circuit protection are desired: current-limiting nonexpulsion power fuses Where lower interrupting ratings are adequate: Non-disconnect power fuses Disconnect power fuses 998 Cooper Power Systems, Inc. R-Temp Envirotemp, Envirotran and Kyle are registered trademarks of Cooper Industries, Inc. R-Tran is a trademark of Cooper Industries, Inc. National Electric Code and NEC are registered trademarks of the National Fire Protection Association. UL is a registered trademark of Underwriter s Laboratories, Inc. 8 Printed on Recycled Paper QUALITY CONTROL All transformers are subjected to Routine and Design Performance Tests per the requirements of ANSI C57.2.00 Each transformer must pass the following tests: Resistance measurements of all windings at the rated voltage connection of each unit, and at the tap extremes. Ratio tests at the rated voltage connection and at all tap connections. Polarity and phase-relation tests at the rated voltage connections. No load losses at rated voltage on the rated voltage connection. Exciting current at rated voltage on the rated voltage connection. Impedance and load loss at rated current on the rated voltage connection of each unit. Temperature rise tests Performed in accordance with ANSI Standards. Performed on one unit of a given rating when test records on an essentially duplicate unit are not available. Applied potential test Induced potential test Routine impulse test P.O. Box 640 Waukesha, WI 5387 www.cooperpower.com MI 3/98