MA-5200 Series MA-5300 Series

Similar documents
MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

IMP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning. Hyciraulic Actuator General Instructions SIEBE

MF4E MF4E

MC-351, 421, 431, MC-4311

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

CP (Vdc) CP (Milliamp) CP (Slidewire)

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

CP CP

MK-6600 Series, MK-6800 Series, and MK-6911

AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions

TS , -850 Series TS , -850 Series TS-57031, TS

AV-401. Application. Features. Applicable Literature. Pneumatic Actuator Valve Linkage Kit General Instructions

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

TS Series TS Series

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

MA40-704X Series MA41-707X Series MA41-715X Series

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

TK-6024, TK-6124, TK-8024, TK-8124

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

2211 Series. Application. Features. One-Pipe Pneumatic Room Thermostats General Instructions SPECIFICATIONS

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

AV-611. Application. Applicable Literature. Schneider Electric DuraDrive Globe Valve Linkage General Instructions

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Application. Features

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

AV-608 Linkage Adapter Kit

MX4X-6XXX-20X Series MX4X-7XXX-20X Series

Powers TM Controls EA 338 Electronic Actuator

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

TAC DuraDrive Product Guide Direct Coupled Actuators

VA-4233-GGx Series Electric Valve Actuators

Non-Spring Return EconoDrive Floating Actuator

MS Series MS Series MS Series

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

MAx1-720x Two Position Series MFx Floating Series MSx Proportional Series

AM-676, AM , AM-690-R, AM-692, AM-693-R, AM-762, and AM-763

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions

M436A/M836A,B Damper Motors

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

NETSIAN TECHNOLOGY VALVE SCHEDULE

AV-602. Application. Globe Valve Linkage General Instructions

M9216 Series Electric Spring Return Actuators

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

Damper Actuator Installation

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

Installation Instructions

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Installation Instructions

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

Flowrite 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

M100F Incremental Motor Actuator R81F Interface Board

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Invensys Energy Solutions 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL United States of America

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

TKS-5001, TKS , TKS-6001, TKS-7001

MF /MS Series

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

MF Series MF Series MF Series

Torque min. 35 in-lb, for control of air dampers

ML6425, ML7425 Spring Return Electric Linear Valve Actuators

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

VA-4233-AGx Series Electric Valve Actuators

A25 Series Warm Air Control with Manual Reset

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

ML7421A,B Electric Linear Valve Actuator

VB-9213 Series. Application. Features. Applicable Literature

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

MS4120F, MS4620F, MS8120F, S2024-F, S20230-F Fast-Acting, Two-Position Actuators

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Series 41 and 81 Modutrol IV Motors

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

MA40-704X Series, MA4X-707X Series, MA4X-715X Series DuraDrive Series Spring Return Two-Position Actuators General Instructions

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

VA-8020 Floating Valve Actuator

Transcription:

MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require a return to the normal position upon power interruption. Features Two-position actuators controlled by an SPST controller Spring return 24 Vac, 120 Vac, and 240 Vac models are available An actuator with the part number suffix "-500" has a built-in, adjustable, SPDT auxiliary switch Available in damper models or base models that require damper or valve linkage Die cast lower housing with 1/2" conduit opening and painted steel upper housing Hydraulic actuator with oil-immersed motor and pump Applicable Literature TAC Pneumatic Products Catalog, F-27383 TAC Environmental Controls Cross-Reference Guide, F-23638 TAC Environmental Controls Reference Manual, F-21683 TAC Environmental Controls Application Manual, F-21335 General Instructions Sheet F-19069, for Valve LInkages AV-600 and AV-601 Material Safety Data Sheet MSDS-3, (Until Feb. 1989) Material Safety Data Sheet MSDS-12 (Currently) MA-521X Series Valve Actuator MA-533X Series Damper Actuator Printed in U.S.A. 8-08 Copyright 2008 TAC All Rights Reserved. F-15070-14

SPECIFICATIONS Actuator Inputs Control Circuit: Two wire, SPST. Power Input: Refer to Table-1 and Table-2. Connections: Color-coded 4 ft. (1.2 m) leads. Actuator Outputs Electrical: Auxiliary Switch (MA-5xxx-500), 10 Amps, 120/240 Vac adjustable SPDT, factory set to close the N.O. contact at the retracted end of stroke. Mechanical: Stroke, Damper Approximately 2" (51 mm) from fully retracted to fully extended (includes AM-601 linkage). Valve Approximately 9/16" (14.3 mm) from fully retracted to fully extended. Nominal Damper Area, Actuator sizing should be done in accordance with damper manufacturer s specifications. Environment Ambient Temperature Limits: Shipping & Storage, -40 to 140 F (-40 to 60 C). Operating, Damper 0 to 140 F (-18 to 60 C). Valve Refer to Table-3. Humidity: 5 to 95% RH, non-condensing. Location: NEMA Type 1. Agency Listings: UL 873, Underwriters Laboratories (File # E9429 Category Temperature-Indicating and Regulating Equipment). CSA, Certified for use in Canada by Underwriters Laboratories. Canadian Standard C22.2 No. 24-93. European Community, EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). Table-1 Model Chart for Damper Actuators. Part Number AC Voltage +10/ -15% Actuator Power Input Hz VA Watts Timing in Seconds @ 72 F (22 C) To Extend (No Load Stroke) Retract on Power Loss Torque Rating (Extend & Retract) lb.-in. (N-m) MA-5330 120 MA-5333 24 50 60 18 14 60 15 20 (2.3) 2 Copyright 2008 TAC All Rights Reserved. F-15070-14

Table-2 Model Chart for Valve Actuators. Also for Damper Actuators with Field Assembled Damper Linkages. Part Number AC Voltage +10/-15% Actuator Power Input Hz VA Watts 10 Amps Aux Switch Timing in Seconds @ 72 F (22 C) To Extend (No Load Stroke) Retract on Power Loss Required Linkage a Damper Valve MA-5210 MA-5210-500 120 No Yes MA-5211 MA-5211-500 240 50 60 18 14 No Yes 60 15 AM-601 b AV-600 AV-601 c MA-5213 MA-5213-500 24 No Yes a Damper models are provided with factory-installed damper linkages. Only base models require separately-ordered linkages. b With the installation of the AM-601 damper linkage, these valve actuators become functionally the same as the damper actuators listed in Table-1. Refer to Table-1 for the torque rating. c May be required for steam and hot water. Refer to Table-3. Table-3 Maximum Allowable Ambient Air Temperature for Valve Actuators. Maximum Temperature of Media in the Valve Body (Check the Rating of the Valve) F ( C) Maximum Ambient Temperature of MA-521x Series AV-600 (Only) F ( C) AV-600 and AV-601 F ( C) 366 (186) 90 (32) 90 (32) 340 (171) 100 (38) 100 (38) 281 (138) 115 (46) 140 (46) a 181 (83) 140 (60) a 140 (60) a 80 (26) 140 (60) a 140 (60) a a Maximum ambient temperature of the actuator must never exceed 140 F (60 C). ACCESSORIES Common 11-1612 1/2" conduit bushing Damper Linkages AM-111 Crank arm for 5/16" (8 mm) diameter damper shaft AM-112 Crank arm for 3/8" (10 mm) diameter damper shaft AM-113 Crank arm for 1/2" (13 mm) diameter damper shaft AM-115 Crank arm for 7/16" (11 mm) diameter damper shaft AM-122 Linkage connector straight type AM-123 Damper clip AM-125 5/16" diameter x 20" damper rod AM-125-048 5/16" diameter x 48" damper rod AM-132 Ball joint connector AM-161-3 Damper linkage kit AM-601 Device includes mounting bracket, damper linkage with spring, and AM-122 straight connector. Required to modify (MA-521x series) valve actuators into 2" (51 mm) stroke damper actuators. AM-602 Spacer Valve Linkages AV-600 Valve linkage AV-601 Valve linkage extension for hot water and steam applications; use with AV-600 TOOLS (factory-available) TOOL-12 Wrench for adjustment of auxiliary switch TOOL-19 Spring compression tool for AV-600 TOOL-37 1-5/8" (41 mm) open-ended wrench F-15070-14 Copyright 2008 TAC All Rights Reserved. 3

TYPICAL APPLICATIONS (wiring diagrams) Aux. Switch Leads (-500 Actuators only) Brown (N.O.) Orange (N.C.) Red/White (C) MA-5XXX Actuator L1 Thermostat or Switch Black Actuator Voltage Vac 24 120 240 L2 Color(s) of L2 Lead Black/Blue White White/Black Green NOTE: Actuator extends when contacts are closed and retracts when contacts are open Figure-1 Typical Wiring for MA-5xxx Series Actuators. INSTALLATION Inspection Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products. Requirements Job wiring diagrams. Tools (not provided): Digital Volt-ohm Meter (DVM). Appropriate drill and drill bit for mounting screws. Appropriate screw drivers and wrenches. TOOL-12, Wrench for adjustment of auxiliary switch. TOOL-19, Spring compression tool for AV-600. TOOL-37, 1-5/8" (41 mm) open-ended wrench. Training: Installer must be a qualified, experienced technician. Warning: Disconnect power supply before installation to prevent electrical shock and equipment damage. Make all connections in accordance with the wiring diagram and in accordance with national and local electrical codes. Use copper conductors only. Caution: Static charges produce voltages high enough to damage the electronic components. Follow static electricity precautions when installing or servicing the device(s). Discharge any static electricity you may have accumulated by using wrist straps, or by touching a known, securely grounded object. Do not exceed the ratings of the device(s). Do not apply power to the unit unless the damper linkage and/or the valve assembly have been installed. Avoid locations where excessive moisture, corrosive fumes, or vibration is present. Do not install insulation on any part of the actuator. 4 Copyright 2008 TAC All Rights Reserved. F-15070-14

Mounting Do not twist or exert any force on the actuator housing during installation. Either turn the base by hand or, if necessary, use a 1-5/8" (41 mm) open-ended wrench (TOOL-37) on the flats provided on the actuator base or the valve body mounting nut. Refer to Figure-2. Housing Base Wrench Flats Figure-2 Housing and Base Location. Dampers The actuator is not position sensitive. It can be mounted in any position in a NEMA Type 1 location. Valves Allow 3" (76 mm) of clearance above the actuator valve assembly for the removal and reattachment of the actuator to the installed valve. 1. Install all two-way valves so that they close against the flow. An arrow on the valve body or tag indicates proper flow direction. 2. Always install three-way mixing valves with two inlets and one outlet. 3. Always install three-way diverting valves with one inlet and two outlets. Caution: For steam applications only, mount the actuator above the valve body at 45 from vertical. 4. Actuators can be mounted in any upright position above the centerline of the valve body. Wiring Requirements Power Leads The low voltage (24 Vac) power leads may be connected to a Class 2 circuit if routed separately from Class 1 circuit wiring. The line voltage (120 and 240 Vac) leads must be connected to a Class 1 circuit. Refer to Figure-7. Refer to Table-4 for the maximum length of run for the power leads, for the given wire size(s). To determine the allowable maximum power lead run when wiring multiple actuators, divide the maximum run shown in Table-4 by the number of actuators on the run. Refer to Figure-3 for further details. F-15070-14 Copyright 2008 TAC All Rights Reserved. 5

Table-4 Power Wiring Data. Actuator Voltage Vac Actuator Model Number Power Lead Colors Wire Size GA Maximum Wire Run ft. (m) 120 240 MA-5210 MA-5210-500 MA-5211 MA-5211-500 Black & White 14 3,500 (1,067) Black & White/Black 14 6,000 (1,829) 24 MA-5213 MA-5213-500 Black & Black/Blue 14 12 300 (91.5) 480 (146.3) 120 MA-5330 MA-5330-500 Black & White 14 3,500 (1,067) 24 MA-5333 MA-5333-500 Black & Black/Blue 14 12 300 (91.5) 480 (146.3) 24 Vac Black/Blue 120 Vac White 240 Vac White/Black To Vac Power Black Green MA-52XX Green To Additional MA-52XX Series Actuators MA-52XX Figure-3 Wiring of Multiple MA-52xx Series Actuators to Single Power Source. Auxiliary Switch Leads The low voltage (24 Vac) auxiliary switch leads may be connected to a Class 2 circuit. The line voltage (120 Vac and 240 Vac) auxiliary switch leads must be connected to a Class 1 circuit and routed separately from any Class 2 circuit wiring. Refer to Figure-7. Wiring Connections Wire Lead Connections (No Conduit) Make connections as required. Refer to Figure-1 for a wiring diagram of a typical application. Refer to Figure-4 for a view of the actuator. Note: The cover plate and screw supplied with the actuator are not required with this method. 6 Copyright 2008 TAC All Rights Reserved. F-15070-14

Figure-4 Connection of Wire Leads (No Conduit). Installing 3/8" Flexible Conduit Onto One or Both Sides of Actuator Flexible conduit may be installed onto one or both sides of the actuator (refer to Figure-6 and Figure-7). Install each conduit as follows: 1. Determine the side of the actuator to which the flexible conduit is to be attached. 2. Remove the knockout (e.g., with channel lock pliers) on the selected side of the actuator. Refer to Figure-5. 3. Make the required connections. Refer to Figure-1 for a wiring diagram of a typical application. Base Knockout Figure-5 Removal of Knockout on Actuator Base. 4. Slip the conduit onto the base, over the ribs. Refer to Figure-6 and Figure-7. 5. If flexible conduit is to be installed on both sides of the actuator, repeat the preceding steps to install the second conduit. Base Cover Plate Ribs or Figure-6 Flexible Conduit Installation to Either Side of Actuator. F-15070-14 Copyright 2008 TAC All Rights Reserved. 7

Low voltage motor leads may be connected to a Class 2 circuit if routed separately from wiring that is other than Class 2 Typical for 24 Vac models (MP-5XX3) 4 x 4 Conduit Box Transformer (AM-610 shown) Cover Plate The line voltage auxiliary switch leads must be separated from Class 2 motor circuit wiring. Leave Knockout in place Note: Class 2 circuit wiring must be routed separately from the wiring from other circuits. Do not route Class 2 circuit wiring in the same conduit box with the line voltage transformer Figure-7 MA-5200 and MA-5300 Series Wiring with Separation for Class 2 and Line Voltage Circuits. 6. Install the cover plate with two screws. The cover plate and two screws are supplied with the actuator. Installing Conduit Box Onto Actuator Installation of a conduit box allows for the attachment of one or more thin wall conduits to the actuator. This procedure also serves as an optional method for connecting flexible conduit to the actuator. 1. Remove the knockout from the cover plate supplied with the actuator. Refer to Figure-8. Cover Plate Knockout Figure-8 Cover Plate Knockout Removal. 2. Slip the actuator s leads through a standard 1/2 conduit bushing (Figure-9, not supplied) and the knockout hole in the cover plate. Refer to Figure-10. 1/8" (3 mm) maximum Use TAC 11-1612, Bridgeport 1102-DC, or equivalent Figure-9 1/2" Conduit Bushing. 8 Copyright 2008 TAC All Rights Reserved. F-15070-14

1/2" Conduit Bushing (not supplied) Base Cover Plate Figure-10 Conduit Bushing and Cover Plate Installation. 3. Seat the conduit bushing in the base. 4. Install the cover plate, using the two screws provided. 5. Loosely install the conduit box and the locknut onto the conduit bushing. Refer to Figure-11. Figure-11 Attachment of Conduit Box to Conduit Bushing. 6. Tighten the locknut as follows: a. Tilt the conduit box approximately 30 degrees counterclockwise, relative to the actuator. b. Finger-tighten the locknut against the conduit box. c. Rotate the conduit box clockwise until it is aligned with the actuator. This will tighten the locknut. 7. Make the required wiring connections. Refer to Figure-1 for a wiring diagram of a typical application. 8. Install the conduit to the conduit box as required. Note: As shown in Figure-10, the hole in the cover plate of the actuator conduit housing is sized to accept both British standard M20 (20 mm) conduit connectors and 20 mm-to-pg16 adaptors for use with DIN PG16 connectors. (Follow the steps for installing the conduit box to the actuator.) F-15070-14 Copyright 2008 TAC All Rights Reserved. 9

Linkage Assembly Damper Note: Each actuator in the MA-5x3x series is provided with a factory-installed damper linkage. No separately-ordered linkage is required. Caution: Do not twist or exert any force on the actuator housing during installation. Either turn the base by hand or, if necessary, use a 1-5/8" (41 mm) open-ended wrench (TOOL- 37) on the flats provided on the actuator base, or on the valve body mounting nut. (Refer to Figure-2.) 1. Determine the best mounting position for the actuator as follows: a. Determine, from the system requirements, if the damper should spring-return to the open position (refer to Figure-12) or closed position (refer to Figure-13) whenever power is lost to the actuator. For example, an outside air damper actuator is typically linked so as to retract (spring-return) to the damper s fully closed position (safe position). Spring returns open on loss of power Open Close Retract Extend Damper Shaft Figure-12 Dampers Open When Actuator Retracts (Spring-Returns Open on Power Loss). Spring returns open on loss of power Extend Retract Open Close Damper Shaft Figure-13 Dampers Open When Actuator Extends (Spring-Returns Closed on Power Loss). b. Be sure to allow adequate working space around the actuator mounting location to mount the actuator, link it to the damper, and wire it into the system (refer to Figure-20). c. If possible, select a mounting position such that, at mid-stroke, the actuator crank arm and the damper crank arm on the drive shaft are each at a 90 angle to the damper rod (Refer to Figure-14). This is the recommended mounting position. It may be necessary to swivel the actuator linkage to arrive at this mounting location. 10 Copyright 2008 TAC All Rights Reserved. F-15070-14

Mid-Stroke Position Mounting Points Actuator Crank Arm Angle from Mid-Stroke Position (See Table) Required Damper Rotation Angle from Mid-Stroke Position Position of Linkage Connector Mounting Points Damper Rod Linkage Connectors Damper Crank Arm Damper Shaft 60 90 Position of Linkage Connector (See Table) 30 45 2" (50 mm) 1-1/2" (38 mm) Figure-14 Recommended Actuator/Damper Mounting. d. Consider the damper rod length when positioning the actuator in relation to the damper. A damper rod that is too long is not rigid enough to provide good control, while a damper rod that is too short makes adjustment difficult. 2. Position the actuator on the duct and mark the location of the mounting holes, using the actuator mounting bracket as a template (refer to Figure-20). 3. Drill or punch the mounting holes in the duct for the appropriate 1/4" (6 mm) diameter screws or bolts. The actuator must be mounted firmly enough to prevent excessive actuator movement under normal damper loading. If there is excessive actuator movement, the damper may not fully open or close. 4. Mount a ball joint connector in the slot on the damper crank arm. To achieve 90 of damper rotation, position the connector 1-1/2" (38 mm) from the centerline of the shaft hole on the crank arm. For 60 of damper rotation, position the connector 2" (50 mm) from the shaft hole centerline. Typically, 60 to 70 of rotation (maximum is 90 ) is sufficient to permit almost maximum air flow through the dampers. (Refer to Figure-14). 5. Rotate the damper to its open position. Install and secure the damper crank arm (with ball joint connector) to the damper shaft, positioning the crank arm as follows (Refer to Figure-14): a. To achieve 60 of damper rotation, position the crank arm so that it is pointed towards the actuator at 30 from its mid-stroke position. b. To achieve 90 of damper rotation, position the crank arm so that it is pointed towards the actuator at 45 from its mid-stroke position. 6. Install the damper rod by sliding one end through the ball joint connector mounted on the damper crank arm, and the other end through the straight connector on the actuator crank arm. Tighten the nut on the actuator crank arm s straight connector. Cut off any excess length of damper rod. 7. For normally open dampers, tighten the nut on the ball joint connector on the damper crank arm. To ensure that the damper closes completely, make adjustments so that the actuator is 1/16" (1.6 mm) from the extended end of stroke when the damper closes. Verify and, if necessary, make final adjustments during system checkout. 8. For normally closed dampers, rotate the damper crank arm until the damper is closed. While holding the damper closed, tighten the nut on the ball joint connector on the damper crank arm. To ensure that the damper closes completely, make adjustments so that the actuator is 1/16" (1.6 mm) from the retracted end of stroke when the damper closes. Final adjustment of the actuator and damper must be performed when the system is powered and functioning. Refer to the CHECKOUT section to ensure that the damper is linked correctly. F-15070-14 Copyright 2008 TAC All Rights Reserved. 11

Valve For valve assembly details refer to AV-600, Valve Linkage Kit General Instructions, F-26279 or AV-601, Linkage Extension Kit General Instructions, F-26280. Refer to Figure-21 for external dimensions of the valve actuator. Adjustments Auxiliary Switch (MA-5xxx-500) The switching point is adjustable over the entire actuator stroke and is pre-set at the factory to close the N.C. contacts at the retracted end of stroke. Turning the switch adjustment screw CW (using TOOL-12), adjusts the make (or break) point closer to the extended end of stroke. (Refer to Figure-15). MA-52XX-500 Series Auxiliary Switch Adjustment Screw Position Indication and Switch Action Cam Figure-15 Auxiliary Switch Actuation Point Adjustment and Position Indication for MA-5xxx-500 Series. CHECKOUT After the entire system has been installed and the actuator has been powered up, perform the following checks for proper system operation. Caution: Never power the actuator without a spring return linkage attached. Positioning with Controller Go, No-Go Test If the sensed media is within the controller s setpoint range, the actuator can be positioned by adjusting the controller setpoint up and down. Check for correct operation of the actuator (valve or damper) while the actuator is being stroked. 1. Apply power to the actuator. The actuator motor should run and the actuator shaft should extend. 2. Remove power from the actuator. The actuator motor should stop running and the actuator shaft should spring-return to the retracted position. 12 Copyright 2008 TAC All Rights Reserved. F-15070-14

THEORY OF OPERATION Refer to Figure-16. The permanently sealed, oil-filled case contains a movable hydraulic piston assembly and an electric pump for the hydraulic system. The pump generates a fluid pressure which is transmitted to the top of the piston, creating a hydraulic force which drives the piston downward. Opposing the hydraulic force is the spring of the valve or damper linkage. When the hydraulic force becomes great enough to overcome the opposing spring force, the piston translates downward, extending the output shaft. The electric pump is powered by the input supply voltage and runs whenever the voltage is applied. When power is removed from the pump, it stops running, decreasing the hydraulic force above the piston. This allows the spring force to overcome the hydraulic force, pushing the piston upward and retracting the output shaft. The oil above the piston is allowed to flow backward through the pump by means of a check valve. Hydraulic Piston Assembly Oil-Filled Case Check Valve Electric Pump Switch/Thermostat Position Indication and Switch Action Cam Switch Point Adjustment for Auxiliary Switch Auxiliary Switch Orange Brown Red/White To AC Power Source Auxiliary Switch Wires Figure-16 MA-5xxx Series Actuators. REPLACEMENT PARTS The installation of replacement actuators, in place of the obsolete series of MA-5xxx actuators (refer to Figure-17), may require additional items. These replacement items are required for the following reasons: 1. The AM-601 damper linkage is used to convert base actuators to damper actuators when damper models are not available. 2. The AM-602 spacer is used when current actuators are installed on old linkages (refer to Figure-18 and Figure-19). 3. The AE-249 transformer (208 Vac to 120 Vac) is used when replacing 208 Vac actuators (MA-5xx2) with 120 Vac actuators (MA-5xx0). 3/4" (19 mm) 1-5/16" (33 mm) 1-5/16" (33 mm) MA-521X-XXX MA-521X-XXX-2 MA-521X-XXX-3 Obsolete Actuators Current Actuator Figure-17 Current and Obsolete Actuators. F-15070-14 Copyright 2008 TAC All Rights Reserved. 13

1-5/8" (41mm approx.) 2-3/16" (56mm approx.) Spacer AM-602 1-5/8" (41mm approx.) Obsolete Linkages AV-315, AV-317, AV-319-10, & AV-319-20 Current Linkage AV-600 Figure-18 Current and Obsolete Valve Linkages. No Strap Strap Obsolete AM-601 Current AM-601-0-0-2 Figure-19 Current and Obsolete Damper Linkages. MAINTENANCE TROUBLESHOOTING FIELD REPAIR The actuator is sealed in oil and requires no maintenance. Regular maintenance of the total system is recommended to assure sustained, optimum performance. Use the following steps to locate malfunctions: 1. Check the actuator by applying the proper supply voltage. 2. The motor should run when power is applied. If it does not run, the actuator is inoperative and should be replaced. 3. While the motor is running, the actuator should extend. If it does not extend, check the mechanical linkage for any damage or misadjustment which could prevent the actuator from extending. If the mechanical linkage is inoperative, adjust the linkage or replace the damaged components, as applicable. If the mechanical linkage moves correctly and freely, the problem lies in the actuator and it must be replaced. 4. If applying power directly to the actuator results in correct operation of the actuator, the actuator and linkage are functional, and the problem lies in the wiring or thermostat. Repair or replace the wiring or thermostat, as applicable. None. Replace an inoperative actuator with a functional unit. 14 Copyright 2008 TAC All Rights Reserved. F-15070-14

DIMENSIONAL DATA 5/16" (8 mm) 4-5/8" (117 mm) (4) 1/4" (6 mm) 4-1/4" (108 mm) 3-1/4" (83 mm) Actuator 4-3/4" (120 mm) 5-3/4" (146 mm) 8" (203 mm) 2" (50 mm) 4-1/4" (110 mm) 5-1/2" (140 mm) Figure-20 Damper Linkage Assembly Dimensions. 3-1/4" Dia. (83 mm) 3-23/32" (94 mm) 6-3/4" (171 mm) 1-3/8" (35 mm) 2-9/32" (58 mm) Figure-21 Actuator Dimensions. F-15070-14 Copyright 2008 TAC All Rights Reserved. 15

Copyright 2008, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, IL 61132-2940 www.tac.com F-15070-14