Gas Fireplace Framing Guide

Similar documents
Gas Fireplace Framing Guide

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

CLUTCH-BRAKES SERIES 5.8 FRENO-EMBRAGUES SERIE 5.8

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Si Ud. o sus operadores no pueden leer el Inglés, se hagan explicar este manual completamente antes de tratar el manejo o servicio de esta máquina.

Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS. Important! Read all warnings before starting assembly.

INSTALLATION INSTRUCTION Magnetic Transformer

Save this booklet PLEASE READ THIS BOOKLET BEFORE OPERATION A CUT ABOVE THE REST 110/220 VOLT ELECTRIC SHEAR SERIAL NUMBER PURCHASE DATE

fabricando los productos que nos mantienen en movimiento Por Katie Kabler making the products that keep us moving By Katie Kabler

Used on 564 SS Gas Fireplaces Only. #8 x 3/8 Sheet Metal Screws. Upper and. Lower Grills. Heat Shield

INSTRUCCIONES TECNICAS

ONE LIFE, ONE DREAM, ONE EXPERIENCE... BE THE SPECIAL ONE onecars.es

Table of Contents. Parts Overview 1-3. Tools Needed 4. Recommended Service Parts 4. Gas Fire-Up Check List 5. Troubleshooting Flow Chart 6-9

MODEL VW2960C ASSEMBLY INSTRUCTIONS

Clavijas y tomas industriales Industrial plugs & sockets

564 Shadowbox Face (w Screen) Instructions

Jump Starter and AC/DC/USB Power Source Arrancador y CA / CC / USB fuente de alimentación

12V Battery Charger & Engine Starter Cargador de baterías 12V y arrancador

All-Fuel Chimney Systems

FLOOR JACK. Operators Manual. Model Ton Capacity. Safety Operation Maintenance Parts

FOR YOUNG RIDERS PARA JÓVENES PILOTOS

Save this booklet PLEASE READ THIS BOOKLET BEFORE OPERATION A CUT ABOVE THE REST 12 VOLT DC ELECTRIC SHEAR SERIAL NUMBER PURCHASE DATE

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

Heavy-Duty Clutch Handler. Max. Capacity: 150 lbs.

MAYWOOD FLORENCE CHESTERFIELD SQUARE WINDSOR HILLS CULVER CITY. MARINA del REY VENICE C1

Assembly Instructions Instrucciones para ensamblar Instructions de montage. Montageanleitungen Montage-instructies

HIGH LIFT JACK STANDS

Model AA Briggs & Stratton Corporation Milwaukee, Wisconsin 53201

COMPANY STANDARD SPECIAL POWER UNIT APPLICATIONS

THE XXV EDITION INTERNATIONAL EXHIBITION NEWS 2018 VENIS NEWS 2018 VENIS

BUZONES INDIVIDUALES EXTERIOR

COLORES DISPONIBLES / AVAILABLE COLOURS CARACTERÍSTICAS TÉCNICAS / TECHNICAL FEATURES. Z14 Nature Self Service Counter Top Ref.

Modified YearRound Calendars

FLOOR JACK. Operators Manual. Model /4 Ton Capacity. Safety Operation Maintenance Parts

Innovation and tradition combine under the common denominator of quality and design in this new cataloge of Bronces Iranzo.

GreenStart Igniter for Inserts: Installation Instructions (SKU )

DVS / 31 DVI Shadowbox Face Installation Instructions (sku black: bronze: )

Installation Instructions M5 HEAD & CENTER SECTION Hitch Rated for 27,000 lbs, Max. Pin Weight 6,750 lbs

Datasheet LEDFLOODSTRIP PLUS. 14/03/18 Grupo MCI

TERRA SERIES WINCH READ AND UNDERSTAND THIS MANUAL BEFORE INSTALLATION AND OPERATION OF YOUR SUPERWINCH.

desired air flows are obtained, the knurled ring can be locked into position. In most instances,

FLOOR JACK. Operators Manual. Model /4 Ton Capacity. Safety Operation Maintenance Parts

Installation Instructions

The Future of Surface Preparation

EE4118. Economy 3 Way Electric Actuated Stainless Steel Ball Valve

Hastings Ranch Dr. Sierra Madre Bl. Sierra Madre Villa Av. Foothill Bl b. Sierra 4 Madre F187. Michillinda Av. Rosemead Bl. 487 Santa Anita Av

PY Energy Sector Strengthening Project (P114971)

KUADRA H PANEL FIJO SHOWER PANEL

MAN Diesel & Turbo. Engineering the Future since Company Presentation. MAN Diesel & Turbo España S.A.U. Fernando Marcos NAVALIA May 2.

12V Manual Battery Charger & Engine Starter 12V Cargador de baterías manual y arrancador

DVL / 33 DVI Shadowbox Face Installation Instructions (SKUs Black: ; Bronze: )

INSTALLATION INSTRUCTIONS

Technical Service BULLETIN

Si Ud. o sus operadores no pueden leer el Inglés, se hagan explicar este manual completamente antes de tratar el manejo o servicio de esta máquina.

INSTALLATION INSTRUCTIONS

ANALYSIS AND SELECTION OF LIGHT VEHICLES STEERING SYSTEMS. 1 Gonzalez-Zavala Eduardo U., 1 Espíndola-Martínez Rodrigo.

PDF // DE REPARACION FREIGHTLINER FL 70 PRODUCT CATALOG

Installation Instructions CRAFT M/L

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

BREAKER AND SORTER OF ALMONDS

Telescopic Transmission Jack

G 2000 QT English (06/04)

READ AND FOLLOW ALL INSTRUCTIONS

FILE MAZDA 5 MANUAL DE SERVICIO EBOOK

DV Power Vent System Model 7THPDVS

CRYSTALVUE PUBLIC VIEW DISPLAY (PVD) FEED THROUGH MOUNTS

MODEL N COMPLETE BASKETBALL SYSTEM OWNER S MANUAL COPY OWNER S MANUAL. Keep this Product ID Number and use when contacting Customer Service:

6.21 (Conventional / Convencional) 6.22 (Progressive / Progresivo) Series (Progressive / Progresivo)

Zoom and Print Options

FILE // MANUAL ALARMA RENAULT CLIO DOWNLOAD

OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

Cajas Boxes. Cajas derivación IP30 Junction boxes IP30. Registros de terminación de red ICT Register and ICT enclosures

Specification Grade Contemporary Wall Mount/Technical Installation Data

LED VaporProof Fixture

j Universal Studios CityWalk k California State University, Northridge l Taft High School

Air Operated End Lift

HYDRAULIC CLUTCH-BRAKE SERIES

HHL W-Line Elevating Platform Manual de Recambios Spare Parts Manual

SLIM GROUND LINER 198 GRUPO MCI

Make sure all wiring is inserted into the cavity between the insert and the fireplace. Failure to do this may cause the wiring to become damaged.

Manual. Handleiding. Manuel. Anleitung. Manual. VE.Bus BMS. ES Appendix

TOE KICK AND ACCESSORIES

SIT Pilot Assembly Retrofit - # 308 (Replaces R. Shaw Pilot Asbly) (SKU # )

APPROVED HETAS APPROVED

Fast Lift Hydraulic Service Jack

OPERATOR'S MANUAL MANUEL DEL OPERADOR

Si Ud. o sus operadores no pueden leer el Inglés, se hagan explicar este manual completamente antes de tratar el manejo o servicio de esta máquina.

FILE - RENAULT KANGOO 1999 OWNER MANUAL

PDF OPEL INSIGNIA GPS MANUAL EBOOK

MANUAL DE SERVICIO JEEP LIBERTY DOCUMENT

MANUAL DESPIECE VOLKSWAGEN TOURAN

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

LED VAPOR PROOF FIXTURE

PVC FOOT VALVE SKU: CV4674

Large Diameter Chimney System

UNE ISO RNL

Installation instructions concerning seat heating elements for the front seats Instruction de montage pour chauffage de sièges avant Instrucciones de

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Transcription:

Gas Fireplace Framing Guide Models, 21 TRV, 564 SS, 564 SS CF, 564 HO, 864 TRV, 864 TRV CF, 854 ST, 864 HO, 3615 HO, 4415 HO, 4415 HO See-Thru, 6015 HO, 4237 Clean Face and ProBuilder 42 Note: For General Reference Only. Aways consult the product Installation Manual for exact installation information. Installation Manuals can be found at www.fireplacex.com 1/18/2018

WARNING: Sheet metal edges can be sharp ADVERTENCIA: Los bordes de chapa metálica pueden estar afilados CAUTION: RESTRICTOR ADJUSTMENT REQUIRED This heater will not operate properly if the vent restrictor is not set for your specific installation. See Vent configuration section in the owner s installation manual. FIRST FIRE OR START UP Your appliance has been finished with the highest quality paint. Though this paint dries quickly to the touch, it does not cure or become hard until heated up by the appliance during first fire. For this reason the stove will emit light smoke and have a slight odor. Consult your owner s manual for the complete paint curing instructions. Partially open doors or windows to minimize smoke & odor. LA PRECAUCIÓN: EL AJUSTE DE RESTRICTOR REQUERIDO Este calentador no funcionará apropiadamente si el restrictor de abertura no está previsto para su instalación específica. See "La configuración de abertura" corte transversal en el manual de instalación del propietario. EL PRIMERO FUEGO O COMIENZA PARA ARRIBAS Su aparato ha estado terminado con la pintura de mejor calidad. Aunque esta pintura se seca rápidamente al tacto, no hace la cura o becomve duro until calienta por el aparato durante el primer fuego. Para esta razón la cocina emitirá humo ligero y tendrá un olor leve. Consulte el manual de su propietario para la pintura completa curar las instrucciones. Abra puertas o ventanas parcialmente para minimizar humo & olor. 112-10001

564 SS GSR2 SCR Framing Guide Top Vent Configuration 8" (203mm) Diameter Vent 845mm TRAVIS INDUSTRIES HOUSE OF FIRE 12521 HARBOUR REACH DRIVE MUKILTEO, WA 98275-5458 28-1/2"* 724mm <16-3/4" 426mm Weight: 155 Lbs. (70.4kg) * Includes the required 1/2" (13mm) clearance. Minimum Framing Dimensions - Rear Vent Configuration Included Firestop (required) HINT: place the fireplace so the center Part# 250-00747 line is at least 5" (127mm) from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Minimum Framing Dimensions - Top Vent Configuration Minimum 38" (965mm) Fireplace Enclosure Height Vent Clearances for B" (203mm) dia. Vent: 1" (25mm) to the sides, 1" (25mm) below, and 4" (102mm) above the vent to combustibles of Rear Vent.- ki Center 'J/ 24-1/4" 616mm Route the electrical line to a position to the left rear of the fireplace. Route the electrical line to a position to the 33-1/2',. 851mm <'" left rear of the fireplace. 33-1/2" 851mm /. 36-1/2" 927mm = [,,,, 438mm y The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. 36-1/2" 927mm Minimum enclosure height= 38' WARNING: A cut-out for the gas line may be required on the framing. See the dimensions under "Gas Line Connection" for details. The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. Corner Installations - Rear Vent Configuration A typical 45 installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 1" (25mm) 564 SS Firestop Clearance Corner Installations - Top Vent Configuration A typical 45" installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply) Minimum 1/2" (13mm) Clearance 7"(178mm) Approximate (varies due to vent installation) 6" (152mm) Section for 2x6 (51mm X 152mm) Walls 45-3/4" 4" (102mm) Section for 2x4 (51mm X 102mm) Walls 45-3/4"

864TRVGSR2 Framing Guide Top Vent Configuration 8" (203mm) 0 Vent Optional "Extra Room 38-1/4 972mm Weight: 205 Lbs. (93 Kg) Rear Vent Configuration 8" (203mm) 0 Vent TRAVIS INDUSTRIES HOUSE OF FIRE 12521 HARBOUR REACH DRIVE MUKILTEO, WA 98275-5458 20-5/8'" 30 314" 781mm Minimum Framing Dimensions - Top Vent Configuration Minimum Framing Dimensions - Rear Vent Configuration HINT: place the fireplace so the center Included Firestop (required) line is at least 5" (127mm) from both Part # 93006094 vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Route the electrical line to a position to the left rear of the fireplace. Route the electrical line to a position to the left rear of the fireplace..- Ir _ 38" ::r 965mm Vent Clearances 8" (203mm) dia. Vent: 1" (25mm) to the sides, 1" (25mm) below, and 3" (76mm) above the vent to combustibles Center of Rear Vent 30-3/4" 781mm 38-1/2" 978mm 38-1/2" 978mm 25-3/4" 41-1/4" 1048mm Minimum enclosure height= 38-1/2" (978mm) Corner Installations - Top Vent Configuration _.,/- 20-3/4" - The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. A typical 45 installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 112' (13mm) Clearance 41-1/4" 1048mm Minimum enclosure height= 38-1/2" (978mm) -.. ff,e;;; Corner Installations - Rear Vent Configuration The on/off switchtthermostat wire (if A typical 45 installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). TravisFirestop Minimum 1" {25mm) Clearance (sku 93006094) used) should be routed to a location near the right front of the fireplace. 15-1/2" 394mm - -@ 7 112'(91mm) Approximate {varies due to vent installation) NOTE Most installations use: 50-1/2" 6'(152mm)Sectiontor 2X 6Walls(51mm X 152mm) 4"(102mm)Sectionlor 2x4 Walls (21mm X 102mm) (Travis 1198900166) 50-1/2"