Gas Fireplace Framing Guide Models, 21 TRV, 564 SS, 564 SS CF, 564 HO, 864 TRV, 864 TRV CF, 854 ST, 864 HO, 3615 HO, 4415 HO, 4415 HO See-Thru, 6015 HO, 4237 Clean Face and ProBuilder 42 Note: For General Reference Only. Aways consult the product Installation Manual for exact installation information. Installation Manuals can be found at www.fireplacex.com 1/18/2018
WARNING: Sheet metal edges can be sharp ADVERTENCIA: Los bordes de chapa metálica pueden estar afilados CAUTION: RESTRICTOR ADJUSTMENT REQUIRED This heater will not operate properly if the vent restrictor is not set for your specific installation. See Vent configuration section in the owner s installation manual. FIRST FIRE OR START UP Your appliance has been finished with the highest quality paint. Though this paint dries quickly to the touch, it does not cure or become hard until heated up by the appliance during first fire. For this reason the stove will emit light smoke and have a slight odor. Consult your owner s manual for the complete paint curing instructions. Partially open doors or windows to minimize smoke & odor. LA PRECAUCIÓN: EL AJUSTE DE RESTRICTOR REQUERIDO Este calentador no funcionará apropiadamente si el restrictor de abertura no está previsto para su instalación específica. See "La configuración de abertura" corte transversal en el manual de instalación del propietario. EL PRIMERO FUEGO O COMIENZA PARA ARRIBAS Su aparato ha estado terminado con la pintura de mejor calidad. Aunque esta pintura se seca rápidamente al tacto, no hace la cura o becomve duro until calienta por el aparato durante el primer fuego. Para esta razón la cocina emitirá humo ligero y tendrá un olor leve. Consulte el manual de su propietario para la pintura completa curar las instrucciones. Abra puertas o ventanas parcialmente para minimizar humo & olor. 112-10001
564 SS GSR2 SCR Framing Guide Top Vent Configuration 8" (203mm) Diameter Vent 845mm TRAVIS INDUSTRIES HOUSE OF FIRE 12521 HARBOUR REACH DRIVE MUKILTEO, WA 98275-5458 28-1/2"* 724mm <16-3/4" 426mm Weight: 155 Lbs. (70.4kg) * Includes the required 1/2" (13mm) clearance. Minimum Framing Dimensions - Rear Vent Configuration Included Firestop (required) HINT: place the fireplace so the center Part# 250-00747 line is at least 5" (127mm) from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Minimum Framing Dimensions - Top Vent Configuration Minimum 38" (965mm) Fireplace Enclosure Height Vent Clearances for B" (203mm) dia. Vent: 1" (25mm) to the sides, 1" (25mm) below, and 4" (102mm) above the vent to combustibles of Rear Vent.- ki Center 'J/ 24-1/4" 616mm Route the electrical line to a position to the left rear of the fireplace. Route the electrical line to a position to the 33-1/2',. 851mm <'" left rear of the fireplace. 33-1/2" 851mm /. 36-1/2" 927mm = [,,,, 438mm y The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. 36-1/2" 927mm Minimum enclosure height= 38' WARNING: A cut-out for the gas line may be required on the framing. See the dimensions under "Gas Line Connection" for details. The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. Corner Installations - Rear Vent Configuration A typical 45 installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 1" (25mm) 564 SS Firestop Clearance Corner Installations - Top Vent Configuration A typical 45" installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply) Minimum 1/2" (13mm) Clearance 7"(178mm) Approximate (varies due to vent installation) 6" (152mm) Section for 2x6 (51mm X 152mm) Walls 45-3/4" 4" (102mm) Section for 2x4 (51mm X 102mm) Walls 45-3/4"
864TRVGSR2 Framing Guide Top Vent Configuration 8" (203mm) 0 Vent Optional "Extra Room 38-1/4 972mm Weight: 205 Lbs. (93 Kg) Rear Vent Configuration 8" (203mm) 0 Vent TRAVIS INDUSTRIES HOUSE OF FIRE 12521 HARBOUR REACH DRIVE MUKILTEO, WA 98275-5458 20-5/8'" 30 314" 781mm Minimum Framing Dimensions - Top Vent Configuration Minimum Framing Dimensions - Rear Vent Configuration HINT: place the fireplace so the center Included Firestop (required) line is at least 5" (127mm) from both Part # 93006094 vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Route the electrical line to a position to the left rear of the fireplace. Route the electrical line to a position to the left rear of the fireplace..- Ir _ 38" ::r 965mm Vent Clearances 8" (203mm) dia. Vent: 1" (25mm) to the sides, 1" (25mm) below, and 3" (76mm) above the vent to combustibles Center of Rear Vent 30-3/4" 781mm 38-1/2" 978mm 38-1/2" 978mm 25-3/4" 41-1/4" 1048mm Minimum enclosure height= 38-1/2" (978mm) Corner Installations - Top Vent Configuration _.,/- 20-3/4" - The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. A typical 45 installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 112' (13mm) Clearance 41-1/4" 1048mm Minimum enclosure height= 38-1/2" (978mm) -.. ff,e;;; Corner Installations - Rear Vent Configuration The on/off switchtthermostat wire (if A typical 45 installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). TravisFirestop Minimum 1" {25mm) Clearance (sku 93006094) used) should be routed to a location near the right front of the fireplace. 15-1/2" 394mm - -@ 7 112'(91mm) Approximate {varies due to vent installation) NOTE Most installations use: 50-1/2" 6'(152mm)Sectiontor 2X 6Walls(51mm X 152mm) 4"(102mm)Sectionlor 2x4 Walls (21mm X 102mm) (Travis 1198900166) 50-1/2"