Haakon Ellingsen AS Årenga 8, N-1340 Skui P.O. Box 184, N-1309 Rud Phone Fax

Similar documents
EFS EFS 2000 Electric failsafe actuators

ICON 2000 series Electric actuators

The EFS 2000 v4 series are electric quarter turn spring return actuators for closing and opening a valve in emergency conditions.

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

BIFFI. Compact electric actuator for 90 operation, complete with the intelligent control unit ICON 2000 to fit small valves

Haakon Ellingsen AS Årenga 8, N-1340 Skui P.O. Box 184, N-1309 Rud Phone Fax

Intelligent, non-intrusive, multi-turn electric actuator

F01 Electric Actuators

ECU1000 ELECTRONIC CONTROL UNIT

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

ELECTRO-HYDRAULIC ACTUATION SYSTEMS

Skilmatic SI 3 3 Electric Fail-Safe Actuators

The F02 series are compact, intelligent quarter-turn electric actuators for the accurate control of valves with torques from 35 to 2000 Nm /

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES

308 to 17,700 lb.in. Ambient temperature Standard range: -25 C to +70 C / -13 F to 158 F Low temp range: -40 C to +70 C / -40 F to 158 F

Keystone EPI-2 electric actuators

Biffi Fail Safe Electric Actuators, model EFS2000v4 Instruction and Operating Manual

A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction.

ACTUATION SOLUTIONS EXPERIENCE MORE

ACTUATORS AND CONTROLS OVERVIEW

COMPACT ACTUATORS COMPACT PNEUMATIC & HYDRAULIC ACTUATORS

True Fail-Safe Technology and Precision Control for Reliable Shutdown

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

RS ACTUATO RS ACTUATO

PRODUCTS AND CAPABILITIES ACTUATION & CONTROLS ACTUATION & CONTROLS PRODUCTS AND CAPABILITIES

ATM SERIES THREE PHASE MULTI - TURN

Innovation in actuation.

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM

VALVCON ADC-SERIES ELECTRIC ACTUATOR WITH OPTIONAL BATTERY BACK-UP POWER

VALVITALIA VALVE OPERATORS

Electronic Limit Switch Type

TQ Series represents our devoted technology over 30 years of experience in the valve actuation, offering customer the reliable, quality assured, and

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

QUARTER-TURN ELECTRIC ACTUATORS

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

True Fail-Safe Technology and Precision Control Meet Emergency Shutdown and Demanding Process Applications

MORIN. Pneumatic and hydraulic actuators EXPERIENCE MORE

GIG/GIGS/GPO Gas Powered Actuators. GIG/GIGS/GPO gas powered actuators

Type Electronic Limit Switch

LOW PRESSURE ACTUATORS. LOW PRESSURE PNEUMATIC actuators

COMPLETE LISTING OF OPTIONS. Toggles, Lights

IQTF Range. Keeping the World Flowing. Electric full output turn actuators for choke and control valve applications

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Automation is the techniques and equipment used to achieve automatic operation or control.

AT EVO SERIES BATTERY CHARGER

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

ALGA/ALGAS SERIES PNEUMATIC ACTUATORS ALGA/ALGAS PNEUMATIC ACTUATORS

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

ECONOMISER SERIES E2T USER MANUAL

LEDEEN SEF. Smart electric fail-safe actuator and control systems

Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm.

MAQ Series Electric Actuator

DIESEL Engine Fire Pump Controllers Features

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

ATevo SERIES BATTERY CHARGER

Lexium integrated drives

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

AT SERIES EVO BATTERY CHARGER

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

MME/MOE Intelligent Electric Actuators About Ontrac

Redundant Control System

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

BAC Custom Engineered Controls

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuator EQ Series

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

EIM CONTROLS HQ-SERIES QUARTER TURN ELECTRIC ACTUATORS

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Lexium integrated drives

Paralleling Equipment

Quarter turn actuators Index

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

EVO AT SERIES BATTERY CHARGER

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

ELECTRIC MULTI-TURN ACTUATORS for valve automation in the oil & gas industry with high torque requirements

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

825-P Modular Protection System for motors Specification Guide

Double Acting and Spring Return Direct Gas Quarter-turn Actuators Output Torques to 6,500,000 lb.in.

OFO & OFOS HYDRAULIC SUBSEA ACTUATORS

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Installation and Operating Manual

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Linear Valve Electric Actuator

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Automation Selection Guide

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

4 Redundant Control System

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

AE Installation Operation & Maintenance Instructions

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Transcription:

NORWEGIAN DISTRIBUTOR: Ellingsen NOR INSTRUMENTS Haakon Ellingsen AS Årenga 8, N-1340 Skui P.O. Box 184, N-1309 Rud Phone + 47 67151200 Fax +47 67151201 post@ellingsen.biz www.ellingsen.biz EFS2000-BU-E Rev.1 - Sep 2010 Biffi Italia s.r.l. Headquarters, Sales department, 29017 Fiorenzuola d Arda - Italy tel. +39 0523 944411 fax +39 0523 943923 e-mail biffi_italia@biffi.it website: www.biffi.it

Product Brochure 2000 EFS2000: the hi-tech electric fail-safe actuator A simple electric actuator designed and engineered to operate safety valves with ICON2000 advanced and reliable solutions

Features More than half a century ago Biffi started its business in valve actuation. Its world-wide leadership has been built through continuous innovation and the ability to face the new challenges that a fast changing environment comes up with. It was in 1992 that Biffi started its intelligent actuator campaign. Since then Biffi Intelligent actuators have been welcomed by all major companies around the world, in many different applications: platforms, deep tropical forest, Siberian chill and harsh desert environment. With ICON2000, we made a further step forward towards ease of use and maintenance. Release 2004 of ICON2000 introduces a new philosophy in the construction of electric actuators electronic cards: all major optional functions are integrated in the base card, which allows easy plug-in of future upgrades. EFS2000 is the latest step in the acknowledgement of Biffi product quality and reliability. EFS2000 integrates in one single actuator all the advanced technological solutions of the ICON2000v4 with a strong and reliable spring-return mechanism for safe applications. The EFS2000 is an Electric Quarter Turn Spring Return Actuator which has the purpose to close or open a valve in emergency conditions, when an ESD alarm signal occurs or when motor power supply fails. Actuator operation, setting and diagnostics are available via the integral user-friendly pushbutton panel Bluetooth TM, radiofrequency wireless connector based on a qualified Bluetooth TM class 1 module(*) available as standard Watertight and explosion-proof PDAs are available from Biffi Italia for actuator operation, download of diagnostic info, non-intrusive upgrading of firmware and for maintenance purposes through Bluetooth TM Enhanced hardware and software performances to offer: - advanced maintenance data including reports on the last opening and closing position/torque curves with relative parameters and with direct comparisons with reference curves; - detailed and updated information on actuator internal parameters with precise and clear alarm reports, with both General and Recent (partial) log; - Data logger function for collecting different types of data for maintenance or diagnostic programs, available both in: RECORDER mode for measurement and memorization of main actuator internal parameters with configurable SAMPLING TIME and START DATE and TIME EVENT mode with memorization of OPEN or CLOSE commands, including indication of source, date and time with configurable START DATE and TIME T-RECORDER mode for measurement and memorization of torque and temperature with configurable SAMPLING TIME, START DATE and TIME. STOP of recording in case of torque alarm. 2 (*) US and Italy patented Bluetooth is a trademark of Bluetooth SIG, Inc., USA

Customized displays: - Numeric: 3 1 / 2 digits, for the indication of position or torque - Graphic: 32x122 dots, for a complete diagnostic user-friendly communication with the operator - Backlights - Heater - 8 selectable languages as standard A single enhanced-type terminal board Advanced open bus communication protocols: - Lonworks - Profibus DPV0, DPV1 and Redundant DPV1 - Foundation Fieldbus - Modbus - Hart Diagnostics Internal circuits continuously monitor the status of the system and elaborate all the information coming from the sensors: diagnostic messages are displayed in one of the available languages, so that there is no need to decipher complicated codes. The set of messages is complete both with alarms and warnings. Partial Stroke Test (PST) The PST is proposed as an essential part of the diagnostics. Through a specific procedure a partial stroke test function can be carried out to check the functionality of the essential parts achieve the EFS safety function while the valve/actuator is in line and in service. SIL Certified.. Suitable for use in SIL 3 applications following IEC 61508 / IEC 61511 - TUV Certified. 3

The EFS2000 actuator consists of six main parts: 1. a spring return mechanism, which moves the valve in the foreseen fail-safe condition when requested by an ESD signal or by a motor power failure. 2. a multiturn electric actuator which operates, through an epicyclic gear reduction (3) the valve during normal working conditions and in the mean time compress the spring when the operation is in opposite direction to the fail safe direction. 3. an epicyclic gear reduction, which increment the torque of the multi turn actuator and transform the stroke into a quarter turn value. 4. an electro-magnetic clutch which hold in position the female wheel of epicyclic gear (3) during the normal operation and release it in case of fail-safe function. 5. an hydraulic control group which is necessary to adjust the fail-safe speed and to manually operate the actuator by means of a hand-pump in case of power failure. 6. a local control and configuration panel which is utilised to configure the functional parameters and to operate locally (OPEN/CLOSE/OFF-EMERGENCY/RESET) the actuator when electric power is present. Working Principle The spring return system is kept in fail safe position by helical springs. During the normal operation the multi-turn turn electric actuator transmits the movement to the valve through the epicyclic gearing reduction and to the spring return mechanism through the rack. Spring return mechanism is based on rack-pinion mechanism; the rack is connected in one side to the spring and in the other side to the hydraulic cylinder; pinion of rack-pinion mechanism is connected to the valve stem. Input shaft of the epicyclic gearing reduction is connected the multi-turn actuator output shaft; output shaft of the epicyclic gearing reduction is connected to the pinion of rack-pinion mechanism. The female wheel of the epicyclic reduction is reversible: during normal operation it is kept on position by means of a electromagnetic clutch which hold the worm shaft connected to the epicyclic gearing. The coil of the electromagnetic clutch is normally fed by a direct current from separated external power source, or derived from motor power voltage, through a supply module. When the ESD condition occurs, the supply to the electromagnetic clutch is cut causing the disconnection of system which hold the worm shaft: in this conditions the epicyclic gearing become reversible causing the movement of the actuator on the fail condition by the effect of the spring. To avoid dangerous shock to the valve during the ESD action, an hydraulic damper is mounted on the spring system, whit an adjustable flow control orifice to be set to obtain the specified ESD times. Position of the valve is continuously monitored both in electric mode, both in fail-safe condition, by means of a position sensor directly connected the EFS output drive. After a Fail-Safe action, a local RESET is required, through the local control panel. Emergency Closing Operation In case of electric supply failure the electromagnetical lach opens and the actuator moves the valve in closing position by spring 4

Fail safe time regulation The closing time is adjustable by flow regulator 526 Local manual operation to open In case of loss of electric supply, switch valve 998 to manual mode and actuate hand pump 540 to open the actuator Local manual operation to close With valve 998 in manual position press the lever of hydraulic pushbutton 414, the actuator moves in closing by spring 1 Single acting spring return hydraulic actuator 30 Hydraulic accumulator (piston type/spring return) 352 Needle valve 356 Hydraulic filter 379 Check valve 395 Safety relief valve 414 2/2 N.C. hand-operated spring-return valve 526 Bidirectional flow regulator 527 Nozzle 528 Unidirectional flow regulator (adjustable setting) 540 Handpump 621 LP/HP pressure gauges 966 Terminals enclosure 998 2/2 N.C. hand-operated valve (auto/manual) 999 Electromagnetical latch 398 PST SOV (optional) Selector 998 is drawn in AUTO position Control Group Functions EFS2000 are equipped with an Hydraulic Control Group with two base functions: Adjustment of fail safe time Manual override function to operate the EFS when electrical power is not available. Adjustment of fail safe time is done trough the flow control valve (528). Manual override through the hand pump (540). Before to perform the local manual operation by hand-pump it is necessary to guarantee that the electromagnetic clutch is open: press the pushbutton OFF (Red mushroom) on the local control panel to be sure that clutch is really open. After the above operation, using a local two-positions (AUTO/MANUAL) hydraulic selector (998), select the local operation mode and successively through the hand pump manual operation can be carried out. At the end of manual operation, if the actuator is required to remain in the position opposite to the spring, it is necessary to leave the hydraulic selector in MANUAL position. To restore the electric mode function the hydraulic selector must be moved to AUTO position and, as soon the electrical power is available, the red mushroom pushbutton must be pressed to RESET the actuator. Select then LOCAL or REMOTE position, on the local control panel, according to the wanted type of operation. Legenda AUTO MANUAL 1 - Single acting spring return hydraulic actuator 30 - Hydraulic accumulator 39 - Selector position microswitch 352 - Needle valve 356 - Hydraulic filter 379 - Check valve 395 - Safety relief valve 414 - Hydraulic pushbutton 526 - Adjustable flow regulator 527 - Flow regulator 540 - Handpump 621 - Pressure gauce 966 - Terminals enclosure 998 - Auto/manual selector 999 - Electromagnetic latch 5

...in cost reduction and user-friendliness The reduced number of mechanical parts ensures higher reliability and lower maintenance costs. The aluminium alloy highly resistant housing and covers, together with a lower number of joints, have increased EFS capacity to stand up to the most aggressive environments. A double-sealed enclosure assures protection from dust and humidity. The choice of internal components has increased the overall system efficiency (the motor is directly engaged to the gears) lowering the operational costs. Reduction of training costs is also one of the goals we have achieved through the user-friendliness of the system. No more codes to decipher: the EFS menu is clear and easy, and comes with all the following languages: Italian, English, Spanish, Portuguese, French,Turkish, Russian and Norwegian. Torque sensor The direct measure of the motor speed reports torque with high precision and a resolution of 1% of the nominal torque. Torque detection is based on motor torque vs. speed characteristics, voltage and temperature compensated. The torque vs. speed curve is memorised for each type of motors and in case of motor replacement simply a new configuration from the actuator local control panel is requested. Position sensor Low power consumption, long-life, absolute position sensor controlled by a dedicated microprocessor. Rotations in both senses are recognised and counted. If manually operated during power failure, the position is updated, stored and displayed locally. Electronic card: the latest technology The card is controlled by an high-performance microchip, with a slash memory. This allows high flexibility and the possibility to be re-programmed if necessary. The internal wiring is considerably reduced. The modular design of the electronic cards allows high flexibility for a great variety of combinations. All the electronic cards are treated with a tropicalisation protection in order to increase the performances even in the most severe enviromental conditions. 6

7

A dedicated software for PC and PDA is available for EFS 2000. With the new software, total control of EFS 2000 is always available in your hands and in your office. With a smart user-friendly graphic interface, all the actuator information, set-up, configuration data, diagnostic messages and data logger info are available for visualisation, analysis and reconfiguration from your PDA or PC. PDA Manager The PDA Manager will transform your common PDA or dedicated industrial PDA into a strong tool for the complete control, set-up and diagnostics of the EFS 2000 actuators installed in your plant. A user-friendly graphic interface reproduces the actuator local control panel for an easy control of the valve and offers several tools for a complete analysis of the actuator status. EFS 2000 supports Bluetooth TM non-intrusive communication with the possibility to communicate with the actuator within a distance of several meters from any angle. In addition, it is possible to connect to all the actuators within operation distance with one single PDA. 8

All the data exchanged with the actuator on-field can be shared with your PC in the office through the PC Manager Software. Connect the PDA to the PC with the ActiveSync program and download all the data. Standard PDA minimum basic requirements: Operating systems: Windows Mobile TM 2003 for Pocket PC; Bluetooth TM interface module; Processor: 266 MHz processor; Memory: 32 MB SDRAM minimum; 3.5" TFT display with 16k colour depth. Ex-hazardous area industrial PDA technical characteristics: - High performance industrial PDA based on Windows Mobile TM, with compact external dimensions, an integrated WLAN, USB and Bluetooth TM port. - Meets different industry requirements operating both inside and outside of Ex-hazardous areas. Basic features: Ergonomic design to facilitate operations without fatigue during continuous use; High resolution colour display, readable even in the most unfavourable light conditions; Protection from static electricicty, water and dust; Shockproof housing (non-corroding); Standard keyboard with navigation field and programmable keys; 3.5" TFT display with 16k colour depth. Technical data sheet: Operating systems: Windows Mobile TM 2003 Premium-Software for Pocket PC; Processor: 400 MHz processor based on Intel technology; Power supply: Rechargeable battery; Standard delivery: Unit, Charger, Operating instructions, safety instruction, software CD; Ex-Data: Ex-hazardous application intrinsically safe type and suitable for different gas and dust atmospheres, ATEX or other certification. 9

PC Manager PC Manager transforms your PC into a strong tool for the control, set-up and diagnostics of EFS 2000 actuators. A user-friendly graphic interface reproduces the actuator local control panel for an easy control of the valve and offers several tools for a complete analysis of the actuator status. EFS 2000 supports Bluetooth TM non-intrusive communication or serial communication (intrusive). The same interfaces available with PDA MANAGER with an improved graphic release (considering the larger screens available on PCs) are easily syncronisable with the PDA: - Actuator control: 10

- Actuator maintenance and diagnostic informations: - Actuator set-up: - Actuator data logger: PC Manager software supports Bluetooth TM, or serial communication (Windows 2000 and XP operating systems). 11

Standard ICON2000 multiturn electric actuator 12 Spring return mechanism

Local control and configuration panel Hydraulic control group for manual operation Electromagnetic clutch Epicyclic gear reduction with rack and pinion transmission 13

The base version is an intelligent actuator with hardwired (i.e. point-to-point) connection. High profile standards: all major features are included in the base version. Automatic phase correction The valve will be protected as the system automatically recognises and corrects phases preventing any unforeseen error in the rotation direction. Phase failure correction In case of loss of one phase, this features prevents the motor from overheating. The minimum time to set the alarm on is 100 ms, in order to prevent the system from being influenced by casual oscillations. In case of loss of one phase during motor running, the actuator will reach the end-of-travel position before setting the alarm condition and de-energising the actuator. Motor thermostat If during operation the temperature of the motor overrides the security limits, a thermostat will set the alarm condition and the command signal will be inhibited. Jammed valve protection If, after a command (close/open), the valve position does not change within a pre-set time, an alarm condition is set and the command signal will be inhibited. The pre-set time can be any time within an interval of 2 to 100 seconds. Anti-hammer protection This feature will protect both the motor and the valve. If a torque limit is reached it will prevent the valve from moving in the same direction which caused the torque limit. Instantaneous reversal protection When the actuator is operating in one direction and an immediate command for a reverse direction is set, unpredicted current surges arise with possible damages to the motor. To prevent such problems, a delay between the opposite commands can be programmed from 500 ms to 5 seconds. Warnings Warning signals become active when the operating conditions are close to a critical alarm level. Warning is displayed but operation is not interrupted. Remote controls Three different configurations are available: - 4 wires (OP, CL, Stop, C/latched) - 3 wires (OP, CL, C/push-to-run or latched with instant reverse) - 2 wires (NO contact to open or reverse) Control voltage - 24Vdc, internal supply - 20 to 125 Vdc, external supply - 20 to 120 Vac, external supply 14

15

Emergency Shutdown (ESD) When an ESD signal is received, the actuator performs the ESD programmed action, moving on the fail position under the action of the spring. The ESD action is performed by default when the ESD signal is sent. Other conditions for ESD can be configured through the local interface: - ESD in case of loss of main power; - ESD in case of Local Selector selected in OFF position - ESD by an emergency local pushbutton (mushroom type). Local RESET After an ESD action, normal operation can be restored after a Local RESET through the local pushbutton, or rather be automatically restored, depending on configuration. Analogic position retransmission Through 4-20mA with galvanic insulation Remote output contacts 7 voltage-free latching contacts and 1 change-over, voltage-free contact of relays are available for remote indication. They can all be configured as Normally Open or Normally Closed for one of the following conditions: - Fully open - Fully closed - Intermediate position - Position XX % - Position XX % - Actuator opening - Actuator closing - Motor running - Blinker - Local selected - Remote selected - Local stop active - PST active - Manual operation - Motor over temperature - Torque alarm - Torque alarm in opening - Torque alarm in closing - Jammed valve alarm - Jammed valve in opening - Jammed valve in closing - Mid-travel alarm - Warning - Low battery - EFS in manual mode - PST failed - EFS mid-travel alarm - MAINS (only for AS8) Interlock controls Two interlock inputs are available to inhibit actuator movement in open or close direction 16

Monitor relay When the actuator is not available for remote control, an alarm condition is set through a Monitor Relay with a change-over type, voltage free contact. The Monitor Relay is normally energized and will be de-energized under one of the following conditions: - loss of main power - speed sensor failure - loss of one phase - HW error - internal temperature alarm - mid-travel alarm - electrical contactors failure - configuration error - position sensor failure - EFS mid-travel alarm - EFS in manual mode The following other conditions can be individually configured to switch over the Monitor Relay: - motor over temperature - Manual operation selected - over torque - ESD action - jammed valve - Local STOP pushbutton pressed - LOCAL or OFF selected - Low battery Contactor failure As one of the vital parts of the actuators, contactors are continuously monitored. If a malfunction is detected an alarm is set and the command is inhibited. Maximum torque alarm During torque operation, if the current torque exceeds the relevant set value, the actuator command is inhibited and an alarm condition is set. Opto-coupled remote controls Actuator may be remotely controlled by 4, 3 or 2 wires, depending on the connection on the terminal board. Several options are available: latched, momentary, etc... Torque alarm by-pass During opening command, starting from open/closed position it is possible to set an interval from 0% to 20% of the total stroke where torque alarm is ignored. This will allow the actuator to win the Break-to-open torque. High/Low electronic temperature Through a semiconductor-based temperature sensor, the temperature in the electronic card is detected and an alarm condition is set on reaching the lowest/highest limits. 17

Local operator interface The local interface is designed for easy operation and to supply a complete and clear set of information. It is composed of - a padlockable three-position selector for LOCAL/OFF/REMOTE operation selection - two pushbuttons for local OPEN/CLOSE controls and menu navigation - one pushbutton for local stop - 2 customised displays, with backlight and heater: numeric 3 1 / 2 digit display for torque and position indication graphic display supporting various character sets 3 bi-coloured LED (green/red) to indicate fully open/closed/intermediate position 1 bicoloured LED (red/yellow) to indicate alarm/warning state. 1 blue LED to indicate Bluetooth connection active. Class 2 Bluetooth module available for wireless connection to PDA or PC. All buttons are recessed for protection from accidents or misuse. The local pushbuttons OPEN/CLOSE can be configured with 3 options: latched, latched + instant reverse, push-to-run. Through the local interface the field operator can enter a basic configuration menu which allows to set the following parameters: Base parameters - End of travel position in opening/closing - Opening/closing torque values - Position/torque display - Opening/closing by torque/position - Output contacts - PST function - Remote/Local control feature - ESD feature Extended parameters - Timer parameters - Position servo-amplifier parameters - Fieldbus interface parameters - Data logger - Maintenance date - Diagnostic info -. The configuration menu is password-protected. Added extra features Predictive maintenance Some of the most vital parts of the actuator are monitored: - contactor cycles count - torque trend - alarms data log Timer Function Module (TMR) It allows for partial or complete timer controlled valve stroke.through the local/remote interface the following can be set: - if it has to be active during opening or closing operation - ON time, from 2 to 200 sec max, with resolution of 1 sec. - OFF time, from 1 to 200 sec max, with resolution of 1 sec. - percentage of position when timer starts in opening - percentage of position when timer starts in closing Electronic card identification message Base, terminal board EFS card and 4-20mA card are clearly identified with a 64 character message for fast track including: - Biffi assembly code - Assembly serial number - Manufacturing date - Software and Hardware versions - Description 18

Data log ICON2000 is complete with an exhaustive data log system which will allow for storage of main events occurring during actuator operation. The recorded data are: Alarms: Last 64 alarms and date Last 64 warnings and date Torque curves: The EFS actuator keeps track of the most recently recorded 100 curves in opening and 100 curves in closing, storing data relevant to: date, time, temperatures, main voltage, travel time, torque sample (measured each 1% of position change). Operations: Opening time of the last stroke Closing time of last stroke Total contactor operations Motor run time Time out without electrical power Utilisation rate Recent contactor operations Recent motor run time Recent time without electrical power Recent utilisation rate Maintenance dates: Last maintenance date Next maintenance date Date of the last "clear recent data log" Start-up date PST data: Last PST report Next scheduled PST date PST initial signature (sec/pos) Last 100 PST profiles (sec/pos) EFS data: EFS status Clutch coil status Manual/Auto selector status EFS card temperature (C ) Mushroom pushbutton status EFS heater status Motor rating Motor duty Motor poles Motor type Motor current Test date Wiring diagram Enclosure Certificate Lubricant HW version SW version Torque set-up in opening Torque set-up in closing Valve data To identify the valve and its function in the process, the valve manufacturer/end user can enter the following data: Valve tag name Valve serial number Manufacturer Break opening torque Max stem thrust Flange type 28 characters are available for such information. Customisable torque profiles In some applications you need to set different torque profiles for operating the valve. For this reason we have introduced a 3-point torque profile. Local ESD function Local mushroom pushbutton Emergency and PST curves The EFS actuator keeps tracks of the most recently recorded 16 emergency curves and 16 PST curves and relevant signature (EFS and PST) Log-in recorder: The last 8 log-in data via Bluetooh TM, and PDA/PC are recorded Name plate The basic information about the actuator are electronically stored in a non-volatile memory: Serial number Actuator size Nominal torque Actuator speed Power supply 19

The following is a description of our EFS2000 standard features/options and working conditions. For whatever you may require which is not listed below, please contact Biffi Sales offices. Voltage ratings The actuator can accept the following voltage supplies: Three phase: 50 Hz 230, 240, 380, 400, 415, 440, 460, 480, 500, 690 V 60 Hz 208, 280, 380, 460, 480, 575 V Single phase 110, 115, 220, 240 V at 50, 60 Hz ESD signal voltage: from 24 to 230 Vac/Vdc ESD signal power: 40W in rush/24w maintained Tolerance on fluctuations Voltage: ±10% continuous +10% -15% intermittent Frequency: ±2% Working temperature The standard range is -30 C to +70 C Extended ranges -40 C to +70 C Special temperature range on request. Storage temperature From -55 C to +85 C Environmental protections Only waterproof IP 68 according to EN60529 (15 m dept/90 hours), or alternatively NEMA 4, NEMA 4X and NEMA 6 according to NEMA ICS6 Standard explosionproof degree Ex-d IIB T4 according to IEC / EN 60079 (-40 C/+70 C) IP 68 according to EN60529 (15 m dept/90 hours) Hazardous classification II 2 GD according to ATEX 94/9/EEC IP 68 according to EN60529 (15 m dept/90 hours) Safety Compliance Electromagnetic compatibility directive (EMC) EFS2000 actuators conform to the requirements of EMC Directive 2004/108/EC and further amendments. 20

Low voltage directive (LV) EFS2000 actuators conform with Low Voltage Directive 2006/95/EC and further amendments by the application of EN60204-1 1993. Machinery directive EFS2000 actuators comply with the provision of Machinery Directive 2006/42/EC. Functional Safety (IEC 61508).. Suitable for use in SIL 3 application; TUV certificate Test Summary Life test Standard ICON2000 life test is based on AWWA 540-93 for a minimum of 10,000 cycles. Vibration test EFS2000 are certified as per IEC 60068-2-6- Appendix B (plant induced): frequencies from 1 to 500 Hz (in 3 axes) with 2.0g peak acceleration. Sweep cycles in each axis: 10. Seismic test EFS2000 are tested in accordance with IEC 60068-2-57. Frequencies from 1 to 35 Hz (in 3 axes) with max 2.0g peak acceleration. Verification of structural integrity at 5g. Endurance of oscillogram: 30 seconds. Motors Base version ICON2000 are equipped with three-phase asynchronous, squirrel cage, induction-type low-inertia balanced motors. For single phase or direct current supply, a special interface allows to use conventional asynchronous motors. The open frame is protected by an Explosionproof / Waterproof cover fixed on the actuator housing. Internal protection by a temperature sensor, inserted in the motor windings. The motor flange is directly coupled to the actuator housing with internal flying leads wired to an intermediate terminal board. Electric motors are supplied with insulation class for H as standard with dedicated speed and temperature sensor. 21

Manual override All actuators may be provided with an hydraulic control group for manual operation by means of a hand-pump in case of power failure. This control group is also necessary to adjust the fail-safe speed. Terminal block Terminal block is located in a double sealed enclosure. The terminal block is provided with the following terminations and accessories: - 3 terminals for power supply - 46 terminals for controls - 2 for DC external supply - 2 for low voltage (max 230V) external supply - 1 external earth - 1 external neutral Cable entries Three cable entries are supplied as standard. One extra entry is optionally available. The standard thread is NPT and diameter is: - one with 11/2" - two with 1" - one with 3/4" (optional) ISO Rc 7/1, ISO metric BS3643 and DIN 40430/PG and different diameters are available as options. Data logger Data logger is available for collecting different types of data useful in maintenance or diagnostic programs. Since the amount of collected data is quite large, the data logger must be downloaded onto a Pc/Pda through Irda or Bluetooth TM connection to be viewed. The main functions of the Data logger are: - RECORDER mode: measurement and memorisation of main voltage supply (V), motor temperature (C ), electronics compartment temperature (C ), with configurable sampling time and start date and time (up to 256 sets of measures can be memorised) - EVENT mode: memorisation of Open or Close commands, with indication of source, date and time. Configurable Start date and time. Up to 128 events can be memorised. - T-RECORDER mode: measurement and memorization of torque in opening (%), torque in closing (%), motor temperature (C ), electronic compartment temperature (C ) with configurable sampling time, start and time. The last 256 measures are continuously memorised. When a torque alarm arises the T-recorder stops. 22

23

A large variety of optional modules can be added to the base version. If the option you are looking for is not listed below, please contact Biffi. Fieldbus interfaces ICON2000 modular design is easily upgraded from base-to-base to bus versions. You just need to add the relevant plug-in card. ICON2000 flexible interface allows connection to the major field bus available on the market: Foundation Fieldbus Profibus DPV0, DPV1 and redundant DPV1 LonWorks Hart Modbus Please ask our Sales people for specific requirements. Position Servoamplifier Module (PSM) The module is necessary for actuators in modulating and inching duty. It drives the motor through pulses at constant frequency and duration proportional to the position error, following an externally set analogical point signal. The basic features are: Input: 4-20 ma or 0-20 ma with galvanic insulation Output: 4-20 ma with galvanic insulation for position or torque re-transmission. Three additional SPST output contacts to be configured "make or break". 2 interlock inputs. Position Analogue Retransmission Module (APTM) This card gives a 4-20 ma galvanically insulated module for position or torque retransmission. It is easily plugged in on the base card with no need for dedicated tools. Solid state power switch over temperature (only for heavy modulation duty version) It detects power card maximum temperature condition and sets the relevant alarm. Extended temperature ranges -40/+70 C by use of extended range components -55/+70 C by use of a heating source for internal electronic components, powered by external supply. 24

Partial stroke test (PST) Through a specific procedure a partial stroke test function can be carried out to check the functionality of the essential parts to achieve the EFS safety function while the valve/actuator is in line and in service. Anticondensate heater The internal modules provide enough power to grant anticondensation protection for general applications. But when the environment air humidity reaches critical levels, an additional heater (10 Watt - 1500 Ohm, with external power supply) may be supplied on request. Battery Auxiliary batteries can be provided in an intrinsically safe enclosure. With auxiliary batteries it is possible to remotely transmit position also in case of power failure. 25

Spring to Open The information herein contained is reserved * property of Biffi and is subject to being modified without notice. Standard cable entries: a = 1 NPT b = 1 1/2 NPT 26 EFS2000 Series Overall Dimensions Model A a 1 a 2 B b 1 b 2 b 3 H Weight (Kg) EFS 10 OP 780 374 406 575 273 302 36 475 100 EFS 20 OP 780 374 406 575 273 302 36 475 120 EFS 40 OP 1020 540 480 575 273 302 65 475 160 EFS 80 OP 1020 540 480 575 273 302 65 475 180 EFS 160 OP 1390 780 610 575 273 302 125 525 300 EFS 320 OP 2055 1070 985 582 283 299 164 700 515 EFS 480 OP 2055 1070 985 582 283 299 164 700 550 EFS 960 OP 3025 1925 1100 624 313 311 204 800 880

Spring to Close Standard cable entries: a = 1 NPT b = 1 1/2 NPT EFS2000 Series Overall Dimensions Model A a 1 a 2 B b 1 b 2 b 3 H Weight (Kg) EFS 10 CL 780 374 406 575 273 302 36 475 100 EFS 20 CL 780 374 406 575 273 302 36 475 120 EFS 40 CL 1020 540 480 575 273 302 65 475 160 EFS 80 CL 1020 540 480 575 273 302 65 475 180 EFS 160 CL 1390 780 610 575 273 302 125 525 300 EFS 320 CL 2055 1070 985 582 283 299 164 700 515 EFS 480 CL 2055 1070 985 582 283 299 164 700 550 EFS 960 CL 3025 1925 1100 624 313 311 204 800 880 27

EFS2000 Series WGR Model ISO 5211 Ø d1 Ø d3 Ø d4 N Hmin h1 EFS10 EFS20 EFS40 EFS80 EFS160 EFS320 EFS480 EFS960 F10 F10 F14 F14 F16 F25 F25 F30 125 125 175 175 210 300 300 350 102 102 140 140 165 254 254 298 M10 M10 M16 M16 M20 M16 M16 M20 4 4 4 4 4 8 8 8 50 50 89 89 105 130 130 165 20 20 25 25 30 25 25 30 d7 Max Stem Acceptance Insert Bush Ø d7 25 25 42 42 65 90 90 103 Ø dx 35 35 51 51 76 104 104 120 28

Torque Curves Fail to Open diagram Fail to Close diagram Note: Please refer to the torque performance tables in the following pages. 29

EFS2000 v4-3ph version - Spring to Open data sheet EFS Model EFS 10OP/93-8 EFS 10OP/93-12 EFS 10OP/93-25 EFS 10OP/93-37 EFS 10OP/93-74 EFS 20OP/225-8 EFS 20OP/225-12 EFS 20OP/225-25 EFS 20OP/225-37 EFS 20OP/225-74 EFS 40OP/450-8 EFS 40OP/450-12 EFS 40OP/450-25 EFS 40OP/450-37 EFS 40OP/450-74 EFS 80OP/900-8 EFS 80OP/900-12 EFS 80OP/900-25 EFS 80OP/900-37 EFS 80OP/900-74 EFS 160OP/-8 EFS 160OP/-12 EFS 160OP/-25 EFS 160OP/-37 EFS 160OP/-74 EFS 320OP/-8 (2) EFS 320OP/-12 (2) EFS 320OP/-25 EFS 320OP/-37 EFS 320OP/-74 EFS 480OP/4500-16 EFS 480OP/4500-25 EFS 480OP/4500-37 EFS 480OP/4500-74 EFS 960OP/9000-12 (*) EFS 960OP/9000-25 (*) EFS 960OP/9000-37 (*) EFS 960OP/9000-74 (*) SET [Nm] 93 93 93 93 93 225 225 225 225 225 450 450 450 450 450 850 850 850 850 850 4500 4500 4500 4500 9000 9000 9000 9000 SST [Nm] 130 130 130 130 130 300 300 300 300 300 610 610 610 610 610 1150 1150 1150 1150 1150 7800 7800 7800 7800 12000 12000 12000 12000 MST [Nm] 150 150 150 150 150 350 350 350 350 350 680 680 680 680 680 1250 1250 1250 1250 1250 5800 5800 5800 5800 12000 12000 12000 12000 MET [Nm] 110 110 110 110 110 275 275 275 275 275 520 520 520 520 520 900 900 900 900 900 8200 8200 8200 8200 ET [Nm] 46 31 15 10 5 46 31 15 10 5 92 61 31 20 10 92 61 31 20 10 146 97 73 49 24 230 153 77 51 26 115 77 51 26 202 101 67 34 MAX SET ACTUATOR OUTPUT TORQUE [Nm] (1) 260 240 350 350 350 660 590 520 520 520 1.260 1.130 1.010 1.010 1.010 1.800 1.700 2.000 1.900 1.900 3.900 3.900 4.500 4.400 4.400 7.500 7.500 8.600 8.600 8.400 11.800 11.000 11.000 10.800 17.400 19.200 19.200 19.200 FST From 5 to 45 secs From 5 to 45 secs From 5 to 45 secs From 5 to 45 secs ICON Model IICON-010/25-8 ICON-010/25-12 ICON-010/25-25 ICON-010/25-37 ICON-010/25-74 ICON-010/50-8 ICON-010/50-12 ICON-010/50-25 ICON-010/50-37 ICON-010/50-74 ICON-010/60-8 ICON-010/60-12 ICON-010/60-25 ICON-010/60-37 ICON-010/60-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-020/210-8 ICON-020/210-12 ICON-020/210-25 ICON-020/210-37 ICON-020/210-74 ICON-020/240-16 ICON-020/240-25 ICON-020/240-37 ICON-020/240-74 ICON-030/430-12 ICON-030/430-25 ICON-030/430-37 ICON-030/430-74 Legenda SET Spring ending torque (Nm) at 90 (end to open) SST Spring starting torque (Nm) at 0 (start to open) MST Electric Mode starting torque (Nm) at 90 (start to close) MET Electric Mode ending torque (Nm) al 0 (end to close) ET Time for stroke (sec/90 ) with electric motor at 50Hz; multiply by 0,833 for 60Hz supply FST Fail safe adjustable time (sec/90 ) (*) For model EFS960 please contact BIFFI. (1) The Max Set Actuator Output torque is referred to the Open manoeuvre done with the electric motor set @ 40% and the spring. FOR NO REASON, THE MOTOR SET TORQUE OF 40% IN THE OPENING DIRECTION HAS TO BE CHANGED. (2) Motor service limited to S2-10'. EFS performance table above is referred only to actuators ON/OFF service, up to 60 starts/hour, motor service S2-15'. 30

EFS2000 v4-3ph version - Spring to Close data sheet EFS Model EFS 10CL/93-8 EFS 10CL/93-12 EFS 10CL/93-25 EFS 10CL/93-37 EFS 10CL/93-74 EFS 20CL/225-8 EFS 20CL/225-12 EFS 20CL/225-25 EFS 20CL/225-37 EFS 20CL/225-74 EFS 40CL/450-8 EFS 40CL/450-12 EFS 40CL/450-25 EFS 40CL/450-37 EFS 40CL/450-74 EFS 80CL/900-8 EFS 80CL/900-12 EFS 80CL/900-25 EFS 80CL/900-37 EFS 80CL/900-74 EFS 160CL/-8 EFS 160CL/-12 EFS 160CL/-25 EFS 160CL/-37 EFS 160CL/-74 EFS 320CL/-8 EFS 320CL/-12 EFS 320CL/-25 EFS 320CL/-37 EFS 320CL/-74 EFS 480CL/4500-16 EFS 480CL/4500-25 EFS 480CL/4500-37 EFS 480CL/4500-74 EFS 960CL/9000-12 (*) EFS 960CL/9000-25 (*) EFS 960CL/9000-37 (*) EFS 960CL/9000-74 (*) SET [Nm] 93 93 93 93 93 225 225 225 225 225 450 450 450 450 450 850 850 850 850 850 4500 4500 4500 4500 9000 9000 9000 9000 SST [Nm] 130 130 130 130 130 300 300 300 300 300 610 610 610 610 610 1150 1150 1150 1150 1150 7800 7800 7800 7800 12000 12000 12000 12000 MST [Nm] 150 150 150 150 150 350 350 350 350 350 680 680 680 680 680 1250 1250 1250 1250 1250 5800 5800 5800 5800 12000 12000 12000 12000 MET [Nm] 110 110 110 110 110 275 275 275 275 275 520 520 520 520 520 900 900 900 900 900 8200 8200 8200 8200 ET [Nm] 45,92 31 15,31 10,2 5,1 45,92 30,61 15,31 10,2 5,1 91,84 61,22 30,61 20,41 10,2 91,84 61,22 30,61 20,41 10,2 145,71 97,14 72,86 48,57 24,29 229,59 153,06 76,53 51,02 25,51 114,8 76,53 51,02 25,51 202,04 101,02 67,35 33,67 MAX SET ACTUATOR OUTPUT TORQUE [Nm] (1) 260 240 350 350 350 660 590 520 520 520 1.260 1.130 1.010 1.010 1.010 1.800 1.700 2.000 1.900 1.900 3.900 3.900 4.500 4.400 4.400 7.500 7.500 8.600 8.600 8.400 11.800 11.000 11.000 10.800 17.400 19.200 19.200 19.200 FST From 5 to 45 secs From 5 to 45 secs From 5 to 45 secs From 5 to 45 secs ICON Model IICON-010/25-8 ICON-010/25-12 ICON-010/25-25 ICON-010/25-37 ICON-010/25-74 ICON-010/50-8 ICON-010/50-12 ICON-010/50-25 ICON-010/50-37 ICON-010/50-74 ICON-010/60-8 ICON-010/60-12 ICON-010/60-25 ICON-010/60-37 ICON-010/60-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-010/110-8 ICON-010/110-12 ICON-010/110-25 ICON-010/110-37 ICON-010/110-74 ICON-020/210-8 ICON-020/210-12 ICON-020/210-25 ICON-020/210-37 ICON-020/210-74 ICON-020/240-16 ICON-020/240-25 ICON-020/240-37 ICON-020/240-74 ICON-030/430-12 ICON-030/430-25 ICON-030/430-37 ICON-030/430-74 Legenda SET Spring ending torque (Nm) at 0 (end to close) SST Spring starting torque (Nm) at 90 (start to close) MST Electric Mode starting torque (Nm) at 0 (start to open) MET Electric Mode ending torque (Nm) al 90 (end to open) ET Time for stroke (sec/90 ) with electric motor at 50Hz; multiply by 0,833 for 60Hz supply FST Fail safe adjustable time (sec/90 ) (*) For model EFS960 please contact BIFFI. (1) The Max Set Actuator Output torque is referred to the Close manoeuvre done with the electric motor set @ 40% and the spring. FOR NO REASON, THE MOTOR SET TORQUE OF 40% IN THE CLOSING DIRECTION HAS TO BE CHANGED. (2) Motor service limited to S2-10'. EFS performance table above is referred only to actuators ON/OFF service, up to 60 starts/hour, motor service S2-15'. 31

General Configuration 32

NOTES 33

NOTES 34

For any further information you may require please contact Biffi Sales office; tel. ++39-0523.944411, fax ++39-0523.943923, e-mail: sales@biffi.it Norwegian distributor: Haakon Ellingsen AS Årenga 8, N-1340 Skui P.O. Box 184, N-1309 Rud Phone + 47 67151200 Fax +47 67151201 post@ellingsen.biz www.ellingsen.biz Biffi reserves the right to modify contents without notice. 35