TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

Similar documents
BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Variable Speed Product Line

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Hydrovar and Packaged Hydrovar

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

Commercial Products PUMPS CONTROLS PRESSURE BOOSTING BRGLCAR R4

Commercial Products. Pumps Controls Pressure Boosting BRGLCAR R1

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

ITT. Goulds Pumps G&L Series Commercial Products. Engineered for life. Commercial Water. Goulds Pumps is a brand of ITT Corporation.

SUBMITTAL SAVCPC AQUAVAR CPC. (Centrifugal Pump Control)

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

PPC3 & PPC5. State-of-the-art pump protection and controllers

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

AQUAVAR AQUAVAR 56 AQUAVAR CPC

AquaBoost Packaged Systems

INSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC. (Centrifugal Pump Control) 600 VOLT ADDENDUM

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

5GS, 7GS, 10GS, 13GS, 18GS & 25GS 5-25 GPM, ½ 5 HP, 60 HZ, SUBMERSIBLE PUMPS

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

5LS, 7LS, 10LS, 13LS, 18LS & 25LS 5-25 GPM, ½ 1½ HP, 60 HZ, SUBMERSIBLE PUMPS

4" Motors and Controls

100H, 150H, 225H, 275H

5CS, 7CS, 10CS, 13CS, 18CS & 25CS 5-25 GPM, ½ 3 HP, 60 HZ, SUBMERSIBLE PUMPS

TECHNICAL BROCHURE BHSJ. Basic Convertible Pump HSJ MULTI-STAGE CONVERTIBLE JET PUMPS - 60 HZ

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Sensorless Vector Drives

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

TECHNICAL BROCHURE B5-18SB R1 5SB, 7SB, 10SB & 18SB 5-18 GPM, ½ 1½ HP, 60 HZ SUBMERSIBLE PUMPS

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

Aquavar ABII TECHNICAL BROCHURE BAQUABII R2 VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

Low voltage AC drives

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

RVS-DN Digital Reduced Voltage Motor Starter

TECHNICAL BROCHURE BCP3PH R9. Three Phase 4" Motors, ½-10 HP 60 HERTZ, 3450 RPM

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

RVS-DX Digital Reduced Voltage Motor Starter

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

JC-VSD FP Series II Drives Product Bulletin 1

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

HVAC Products. Introducing the SED2 Variable Frequency Drives

BAC Custom Engineered Controls

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

ROBICON W120 enclosed drive

TECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN. PrimeLine SP SPM & SPH SERIES

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Description 1/8-7.5HP

TECHNICAL BROCHURE BAC2000. Series 2000 Closed Coupled. Series 2000 Frame Mounted. Series A-C 2000 SINGLE STAGE END SUCTION

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

TECHNICAL BROCHURE BC3WIRE-G2 R4

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

SECTION MOTOR CONTROL

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

SECTION VARIABLE FREQUENCY DRIVE UNITS

TECHNICAL BROCHURE B45-70HB R2 45HB, 70HB HIGH PRESSURE CENTRIFUGAL BOOSTER PUMP

J1000. Compact Inverter Series.

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

PSE The efficient range Description

CONSTANT PRESSURE CONTROLLERS

Hydropak Booster Systems. Series motralec

TECHNICAL BROCHURE B5-75GSX. GS-CBM GS Xtreme 60 HZ, 4" SUBMERSIBLE PUMPS

VSD Series II Variable Speed Micro Drives

Number 1 in efficiency

Delta Products VFD CP2000 Bypass Control Packages.

EPS-ECONOMY PUMP STARTER

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

J1000 D E F I 1000 J1000 J1000 J1000 J1000

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

e-hm REPAIR PARTS REPAIR PARTS ReHM R1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

USERS MANUAL MCD REMOTE OPERATOR

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

ITT. Goulds Pumps 5GS, 7GS, 10GS, 13GS, 18GS & 25GS. Engineered for life B5-25GS. Residential Water Systems FEATURES

ABB central inverters PVS to 2000 kva

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

VS1PFB 230V, 50/60 Hz, 3-Phase

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

3x3x7B Series 80 In-Line Mounted Centrifugal Pumps

Series A DC Link Chokes

GS2 Series - Introduction

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

ABB central inverters PVS to 2091 kva

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Transcription:

TECHNICAL BROCHURE BAQUACPC Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

Introduction The Aquavar CPC (Centrifugal Pump Controller) from incorporates the latest state-of-the-art Aquavar technology, with over 10 years of experience providing variable speed pump controllers. The Aquavar CPC is a variable frequency drive and pump specific PLC in one compact unit, that will vary the speed of the motor to maintain a consistent pressure, flow, temperature or level. Here are just a few of the features and benefits of this innovative product: Compatible with previous versions of Aquavar, using version 120 software. Start-up wizards expedite the programming process, for specific applications. Removable control panel/display. Fully backlit display with large text makes the control pad easy to read. Dedicated help key activates parameter descriptions to enable an easy reference to the programming guide. Transducer assembly (0-300 psi) and 16-foot shielded cable included for constant pressure. Helps protect the pump from cavitation, dead head and blocked suction. Helps protect the motor from short circuit, phase loss, overload, undervoltage, overvoltage. Help key activates parameter descriptions to aid in the programming process. Integrated line choke reduces harmonics and provides 3-5% impedence line reactor. EMC/RFI filters reduce drive noise emissions and interference. Preventative maintenance reminders. Fault logger records the last 3 faults and drive characteristics at the time of fault. Detachable conduit box allows more space for incoming power and motor wiring. Fieldbus compatible, standard Modbus Protocol (SCADA). Capable of controlling up to 3 fixed speed pumps, with one drive. Manage fully variable multipump systems using a CPC for each pump. Up to 4 pumps and drives can be linked. Auto lead/lag and switching control built in. Priming delay feature. Energy savings versus standard fixed speed system. Onboard energy calculator. PAGE 2

Layout Port for quickly inserting / removing control panel (keypad). Easy to access terminal block for control wiring of transducer and other peripheral devices. Analog and digital inputs and outputs for start/stop, speed control, monitoring, etc. Relay outputs to provide control wiring for up to three fixed speed pumps (Note: fixed speed pumps require their own starters). Multipump RS 485 connection. Connect up to 4 pumps without additional PLCs! Conduit box is quickly removed with two screws providing easy access to main power and wiring terminals. Backlit display with large, easy-to-read characters. Cell phone style keypad allows the user to quickly change parameters and save modifications. Help key enables onboard parameter explanation to expedite the programming process. Local/Remote allows operator to run motor at full speed manual control or via transducer. PAGE 3

Product Chart INPUT INPUT NEMA 1 Cont. Output Amps NORMAL DUTY Frame VOLTAGE PHASE BASE MODEL Normal Duty ➀ HORSEPOWER ➁ Size CPC20071 3.5 1 R1 CPC20171 8.5 2 R1 CPC20241 12 3 R2 CPC20311 15.5 5 R2 CPC20461 23 7.5 R3 230 1 CPC20591 29.5 10 R3 CPC20881 44.0 15 R4 CPC21141 57.0 20 R4 CPC21431 71.5 25 R6 CPC21781 89.0 30 R6 CPC22211 110.5 40 R6 CPC22481 124.0 50 R6 CPC20041 4.6 1 R1 CPC20071 7.5 2 R1 CPC20121 11.8 3 R1 CPC20171 16.7 5 R1 CPC20241 24.2 7.5 R2 CPC20311 30.8 10 R2 CPC20461 46.2 15 R3 230 3 CPC20591 59.4 20 R3 CPC20751 74.8 25 R4 CPC20881 88.0 30 R4 CPC21141 114.0 40 R4 CPC21431 143.0 50 R6 CPC21781 178.0 60 R6 CPC22211 221.0 75 R6 CPC22481 248.0 100 R6 CPC40061 6.9 3 R1 CPC40081 8.8 5 R1 CPC40121 11.9 7.5 R1 CPC40151 15.4 10 R2 CPC40231 23 15 R2 CPC40311 31 20 R3 CPC40381 38 25 R3 CPC40451 45 30 R3 CPC40591 59 40 R4 CPC40721 72 50 R4 CPC40781 78 60 R4 460 3 CPC40971 97 75 R4 CPC41251 125 100 R5 CPC41571 157 125 R6 CPC41801 180 150 R6 CPC42451 246 200 R6 CPC43161 316 250 R7 CPC43681 368 300 R8 CPC44141 414 350 R8 CPC44861 486 400 R8 CPC45261 526 450 R8 CPC46021 602 500 R8 CPC46451 645 550 R8 CPC50031 2.7 2 R2 CPC50041 3.9 3 R2 CPC50061 6.1 5 R2 CPC50091 9 7.5 R2 CPC50111 11 10 R2 CPC50171 17 15 R2 CPC50221 22 20 R2 575 3 CPC50271 27 25 R3 CPC50321 32 30 R4 CPC50411 41 40 R4 CPC50521 52 50 R4 CPC50621 62 60 R4 CPC50771 77 75 R6 CPC50991 99 100 R6 CPC51251 125 125 R6 CPC51441 144 150 R6 ➀ NOTE: Drive output is 3 phase voltage. PAGE 4 ➁ ALWAYS consult motor maximum amp rating before selecting drive.

Specifications Ratings and Enclosures NEMA 1 (indoor use) standard; other enclosures are available upon request. 1 200 HP (frame R1 R6) wall mounted; 250 550 HP (frame R7 and R8) floor mounted. Ambient temperature 5º F 104º F. Higher temperatures can be achieved using optional enclosure upgrades and derating factor for up to 122º F. At altitudes from 0 to 3300 feet rated current is available, for every 328 feet above 3300 feet the current must be derated 1%. Maximum 6600 feet (consult factory above 6600 feet). Relative humidity lower than 95% without condensation. UL 508C compliant. UL approved. Electrical Characteristics Input Power 3 phase 380 V to 480 V +10%/-15% Frequency 48 to 63 Hz 1 phase 208 V to 240 V +10%/-15%.98 power factor 3 phase 208 V to 240 V +10%/-15% 3 phase 575 V +10%/-15% Output Power 3 phase from 0 to Vsupply (All motors must be 3 phase.) 0 to 60 Hz frequency Nomenclature TYPE CODE CPC 4 370 1 AQUAVAR CPC (Series) Voltage 2 230 Volt 4 460 Volt 5 575 Volt Amps 370 Amps *See Technical Section NEMA Enclosure Rating 1 NEMA 1 (indoor) 2 NEMA 12 (indoor - dustproof) Options Load Reactor Fused Disconnect * Consult factory for other options, if available. Not all combinations may be available. PAGE 5

Weights and Dimensions Frame Sizes R1 through R6 (see product chart for horsepower) The dimensions and weight for the AQUAVAR depend on the frame size and enclosure type. If unsure of frame size, first, find the Type code on the drive labels. Then look up that type code in the Technical Data, to determine the frame size. A complete set of dimensional drawings for AQUAVAR drives is located in the Technical Reference section of the IOM (Installation, Operation Manual). Units with UL Type 1 Enclosures Outside Dimensions UL Type 1 Dimensions for each Frame Size Ref. R1 R2 R3 R4 R5 R6 mm in mm in mm in mm in mm in mm in W 125 4.9 125 4.9 203 8.0 203 8.0 265 10.4 300 11.8 H 330 13.0 430 16.9 490 19.3 596 23.4 602 23.7 700 27.6 H2 315 12.4 415 16.3 478 18.8 583 23.0 578 22.8 698 27.5 H3 369 14.5 469 18.5 583 23.0 689 27.1 739 29.1 880 34.6 D 212 8.3 222 8.7 231 9.1 262 10.3 286 11.3 400 15.8 NOTE: Enclosures are standard NEMA 1, indoor use only. For outdoor, NEMA 3R enclosures, consult factory. PAGE 6

Weights and Dimensions Frame Sizes R1 through R6 (see product chart for horsepower) Mounting Dimensions UL Type 1 Dimensions for each Frame Size Ref. R1 R2 R3 R4 R5 R6 mm in mm in mm in mm in mm in mm in W1* 98.0 3.9 98.0 3.9 160 6.3 160 6.3 238 9.4 263 10.4 W2* 98.0 3.9 98.0 3.9 H1* 318 12.5 418 16.4 473 18.6 578 22.8 588 23.2 675 26.6 a 5.5 0.2 5.5 0.2 6.5 0.25 6.5 0.25 6.5 0.25 9.0 0.35 b 10.0 0.4 10.0 0.4 13.0 0.5 13.0 0.5 14.0 0.55 14.0 0.55 c 5.5 0.2 5.5 0.2 8.0 0.3 8.0 0.3 8.5 0.3 8.5 0.3 d 5.5 0.2 5.5 0.2 6.5 0.25 6.5 0.25 6.5 0.25 9.0 0.35 * Center to center dimension. Weight UL Type 1 Weight for each Frame Size R1 R2 R3 R4 R5 R6 kg lb. kg lb. kg lb. kg lb. kg lb. kg lb. 6.1 13.4 8.9 19.5 14.7 32.4 22.8 50.2 37 82 78 176 PAGE 7

Weights and Dimensions Frame Sizes R7 and R8 (see product chart for horsepower) E1 E1 Top View E2 X2 W2 D H1 Frame NEMA 1 Enclosure H1 W2 Depth Weight E1 E2 mm in mm in mm in kg lb. mm in mm in R7 1503 59.17 609 23.98 495 19.49 195 430 92 3.62 250 9.84 R8 2130 83.86 800 31.5 585 23.03 375 827 92 3.62 250 9.84 Drawing is not for engineering purposes. NOTE: Fusible disconnect included for 200 through 550 HP. Xylem, Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone: (800) 453-6777 Fax: (888) 322-5877 www.xyleminc.com/brands/gouldswatertechnology Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. 2012 Xylem Inc. BAQUACPC R1 May 2012