BUS DOOR SYSTEM ELECTRO-PNEUMATIC IN-SWING BUS DOOR CONTROL MECHANISM Installation Operation and Maintenance Manual RTX-IOM-BDOS-R01-0216 Page 1 of 18
Table of Contents 1. Introduction... 3 1.1. Definitions... 4 2. Operation principal... 4 3. Identification... 5 4. Installation procedure... 5 5. Maintenance... 12 6. Characteristics parts... 12 6.1. Cylinder Ø63/100... 12 6.2. Solenoid valve SVAJ214 (Coil Operated)... 12 6.3. Pneumatic emergency valve... 13 6.4. Solenoid valve SDAJ213 (Coil Operated) Reset valve... 13 6.5. Solenoid valve DSA210(3/2 PILOT OPERATED)... 14 6.6. Pressure switch... 14 6.7. Anti Pinch Sensor (PDV)... 15 7. Trouble shooting... 16 7.1 Additional Information... 17 8. Packaging & store... 18 9. Assistance... 18 RTX-IOM-BDOS-R01-0216 Page 2 of 18
1. Introduction Thank you for choosing ROTEX product. Each product is fully inspected after the production to offer you the highest quality. In order to fully utilize the product, we strongly recommend users to read this manual carefully and understood. This manual provides information on installation; operation and maintenance procedures and related instructions for the ROTEX make Bus door systems. The aim of this literature is to support the use of products in correct manner, and all the technical information provided in the catalogue. The manual should be given to the end user. The manual can be changed or revised without any prior notice. Any changes in product's specification, structure, and/or any components may not result immediate revised version of the manual. The manual should not be duplicated or reproduced for any purpose without any consent of Rotex Manufacturers & Engineers Private Limited, INDIA. Manufacturer Warranty For the safety, it is vital to follow instructions in the manual. It is not ROTEX s liability for any damages which caused by users' negligence. It is not ROTEX's liability for any damages or accidents which resulted by any alteration or modification of the product and parts. If alteration or modification is necessary, please contact the ROTEX directly. ROTEX warrants the product from the date of original retail purchase of the product for one (1) year, except as otherwise stated. ROTEX warranty will not cover the products that the product have been subjected to abuse, accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; damages that occurs in shipment, failure due to power surge, and cosmetic damage. Improper or incorrectly performed maintenance or report voids this Limited Warranty. For detailed warranty information, please contact: ROTEX MANUFACTERURS & ENGINEERS PRIVATE LIMITED, Manapada road, Dombivli (e), Maharastra, India, Pin 421204. RTX-IOM-BDOS-R01-0216 Page 3 of 18
1.1. Definitions WARNING: If not observed, user incurs a high risk of severe damage to product and/or fatal injury to personnel. CAUTION: If not observed, user may incur damage to product and/or injury to personnel. NOTE: Advisory and information comments provided to assist maintenance personnel to carry out maintenance procedures. 2. Operation principal It is improved driving mechanism for opening/closing the door of the buses. It is featured with compact structure, fine performance and long life service. It uses electrical as well as pneumatic systems for opening/closing of the door. Pneumatic control systems can be designed in the form of pneumatic circuits. A pneumatic circuit is formed by various pneumatic components, such as cylinders, directional control valves, flow control valves, etc. Pneumatic circuits have the following functions: 1. To control the injection and release of compressed air in the cylinders. 2. To use one valve to control another valve. Similarly, Electric control systems can be designed in the form of electric circuits. An electric circuit is formed by various electric components, such as micro processor, switches, control box etc. Electric circuits have the following functions: 1. To control the controller operation. 2. To trigger the solenoid valve. RTX-IOM-BDOS-R01-0216 Page 4 of 18
3. Identification 4. Installation procedure The equipment must be installed in the accordance with the laws, guide lines and rules applicable within the country. CAUTION: Do not dismantle the cylinder while operation is in line. Do not allow dirty air or fluids to get into the cylinder. NOTE: Ensure the installation meets the legal and regulatory requirements of the country and state of use. The door assembly should be left in the original packing until it is required for the use. Operating pressure range 4-10 bar. Operating temperature range -20 C to +80 C Check the components as per packing list before installation. Make sure that sealing gasket and glass have been installed on the door panels. RTX-IOM-BDOS-R01-0216 Page 5 of 18
Drawings RTX-IOM-BDOS-R01-0216 Page 6 of 18
RTX-IOM-BDOS-R01-0216 Page 7 of 18
1. First install top mounting plate assembly by mounting the screw through plate into the bus frame at its position as per drawing. 2. Install the sealing gasket on bus frame. Fix it using stiffener plate with self tapping screw. RTX-IOM-BDOS-R01-0216 Page 8 of 18
3. Mount the bracketed support shaft perfectly vertical by pushing shaft head into bearing of the mounting plate and tight the bracket at the bottom. 4. Mount the brackets and handle on the door panel as per the drawing. And then install the door panel on the bus frame one by one by mounting door panel into arm brackets of door shaft. RTX-IOM-BDOS-R01-0216 Page 9 of 18
5. Install the guide rollers properly, to align door with structure to avoid gap adjust eccentric roller shaft. 6. At last install the brush. 7. Manually close and open the door to check its smooth movements. 8. Connect the pneumatic tube and electrical wire as per drawings. 9. Open and close the door automatically to check whether the door moves smoothly. If needed, adjust the speed and cushioning. Initial adjustment When door closes, disconnect its connection with cylinder. Pull the cylinder rod outside 5 mm approx and again join the disconnected connection. Now close the door. This will ensure tight closing of the door. Locking position After initial adjustment, mark the locking position at closed door position. RTX-IOM-BDOS-R01-0216 Page 10 of 18
Electro-Pneumatic circuit diagram RTX-IOM-BDOS-R01-0216 Page 11 of 18
5. Maintenance NOTE: ROTEX recommends ROTEX V09 grease for greasing. Apply the grease with soft brush or similar. In case of any difficulty consult ROTEX distributor. 1. Install, operate and maintain as per the instructions and recommendations of this manual. 2. Observe grease layer on moving parts weekly. 3. While observing apply grease on the moving parts if necessary. 6. Characteristics parts 6.1. Cylinder Ø63/100 Function: Drive the door to open and close Specification: Working Medium Filtered compressed air (Min 50µ) Pressure range 1 10 bar Front fixing Ball & Socket joint Rear fixing MP4 Ambient temp. -20 C to +70 C Cushioning adjustment Both ends 6.2. Solenoid valve SVAJ214 (Coil Operated) Function: Drive the cylinder to open and close Specification: Working Medium Filtered compressed air (Min 50µ) Position 5/2 Pressure range 1 10 bar Ambient temp. -10 C to +70 C Response time - @5bar On time 20 msec., off time 22 msec. Orifice 6.0mm Mounting Through holes in housing, also suitable for mounting on manifold Flow rate 290 l /min Connection 1/4 BSP inlet/outlet 1/8 BSP exhaust RTX-IOM-BDOS-R01-0216 Page 12 of 18
6.3. Pneumatic emergency valve Function: Used for exhaust the system pressure to open the door manually. There are two type of cover proved in which the emergency valve fitted. The round cover installed near the doors at outer side of bus and the square ones inside. 6.4. Solenoid valve SDAJ213 (Coil Operated) Reset valve Function: Used to reset the system after emergency Specification: Working Medium Filtered compressed air (Min 50µ) Position 3/2 Pressure range 2.5 10 bar Ambient temp. -10 C to +70 C Response time -@5bar On time 20msec., off time 22msec. Orifice 3.0mm Mounting Through holes in housing, also suitable for mounting on manifold Flow rate 290 l /min Connection 1/4 BSP INLET/OUTLET RTX-IOM-BDOS-R01-0216 Page 13 of 18
6.5. Solenoid valve DSA210(3/2 PILOT OPERATED) Function: Used to maintain air flow in the system Specification: Working Medium Filtered compressed air (Min 50µ) Pressure range 2.5 10 bar Ambient temp. -10 C to +70 C Response time - @5bar On time 20msec., off time 22msec. Orifice 3.0mm Mounting Through holes in housing, also suitable for mounting on manifold Flow rate 290 l /min Connection 1/4 BSP INLET/OUTLET Pilot Pressure 6.6. Pressure switch Function: To give feedback the system after obtaining requires pressure in the system for operation. Specification Working Medium Filtered compressed air (Min 50µ) Range / Set point 0-10 bar / 1 bar Ambient temp. -10 C to +70 C Mounting On the bracket Connection 1/8 BSP (F) x 8/6 PU tube Conn. RTX-IOM-BDOS-R01-0216 Page 14 of 18
6.7. Anti Pinch Sensor (PDV) Function: Whenever there is any obstruction at the door, due to the difference of air pressure in the cylinders, the mechanical switch operates and that signal is sensed by the controller thus making the door retract automatically. 6.8. Beeper With Indicator Function: During the door closing, the buzzer beeps to warn the driver. And also in case of emergency the beeping frequency changes to warn the driver. RTX-IOM-BDOS-R01-0216 Page 15 of 18
7. Trouble shooting No. Trouble Cause Solution Leakage in cylinder Tight the fittings. 1. Door not working. 2. 3. 4. 5. Emergency Switch System Reset problem Ant pinch function not working Door open/close either too fast/slow. Solenoid valve failure. Controller wiring harness is damaged. Check the on/off switch on the dash board for proper functioning. Low pressure at the main cut off valve Continues air exhaust but not achieved emergency condition. Pressures switch connection loose. PDV sensor connection loose Flow control not adjusted. Cushioning screw adjustment. Check as per manual/replace. Correct the harness connection. Check the connections and wiring/check on/off switch contacts/ replace the switch. Start the engine to build pressure or else check for bending in pipe line. Check button (Manual condition) of SDAJ213 (Reset valve) whether it is in pressed condition. It should be in unpressed condition only. Check the connection of pressure switch. Correct the connection of PDV sensor on cylinder. Rotate the knob of the flow control to adjust the air flow. Adjust the cushioning screw to avoid jerks during door close/open. RTX-IOM-BDOS-R01-0216 Page 16 of 18
7.1 Additional Information 1. Reed switch position Reed switch assembled as per above picture. It is always on rear side of the cylinder in in-swing door. 2. 5/2 double solenoid valve- The open & close coil as per above picture (View from inside of the bus). If it is not functioning properly please check tubing routing of the system (Refer electro-pneumatic diagram). 3. Pressure difference valve (PDV) PDV can be set by grub screw adjustment Clockwise rotation Less sensitivity Anti-clockwise rotation- High sensitivity RTX-IOM-BDOS-R01-0216 Page 17 of 18
8. Packaging & store 1. When not in use, DOOR ASSEMBLY should be kept in a sealed plastic bag in a cardboard box to prevent moisture or dust from contacting product. 2. DOOR ASSEMBLY should be stored in a dry place free from water and dust. 3. Store at temperature between 40 F and 120 F (4 C and 49 C). 4. Locate in an area to avoid damage by impact. 9. Assistance For technical questions or assistance, contact any authorized distributor of ROTEX Or ROTEX MANUFACTURERS AND ENGINEERS PRIVATE LIMITED Manpada Road, Dombivli (East)-421204 Maharastra, INDIA. Tel: +91 251 2871033/ 2871390/ 2871196/ 2871989 Fax: +91 251 2871191 rotexdbl@rotexautomation.com RTX-IOM-BDOS-R01-0216 Page 18 of 18