Installation Instructions

Similar documents
Installation Instructions 7024

Installation Instructions

Installation Instructions

Installation Instructions Series

Installation Instructions Series Series

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

SERIN MONOBLOCK LAVATORY FAUCET with

INSTALLATION INSTRUCTIONS PATIENCE

INSTALLATION INSTRUCTIONS STUDIO S

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Basin Set INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

Installation Instructions

Installation Instructions

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Installation Instructions

Installation Instructions

Installation Instructions 1662SG SG.222

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Installation Instructions 1662SG SG.224

Installation Instructions

Installation Instructions 1662SG SG.223

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Installation Instructions

Installation Instructions

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Allura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Installation Instructions

Installation Instructions

Central Brass C O M P A N Y. A Division of Pioneer Industries, Inc. Installation Guide

Installation Instructions

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS

Deck-Mounted Bath Set with Diverter

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Installation Instructions

Installation Instructions

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Serial Number Purchase Date

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

INSTALLATION INSTRUCTIONS

Ventus Single Handle Vessel Bathroom Faucet

INSTALLATION INSTRUCTIONS

5 5 8 " Description Part # Description Part # O-ring. Tee Connector. Widespread Handle * 1.5 GPM Flow Restrictor PM-080

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Pasadena. 49 Series. Serie 49 Série 49. Lavatory Widespread Faucet Grifo Extenso Para Baño Robinet Sans Applique Pour Lavabo COMPANY

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation For Service Only

2-DOOR LAUNDRY CABINET KIT

Ramus Single Handle Lavatory Faucet

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Single Lever Pull-Out Kitchen Faucet

Service Manual Air Plus Second Stage

INSTALLATION INSTRUCTIONS

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

ROMAN WATERFALL BATHTUB FAUCET

Transcription:

CADET Centerset Lavatory Faucet with Speed Connect Drain Installation Instructions Congratulations on purchasing your American Standard faucet with the Speed Connect Drain, a feature found only on American Standard faucets. Speed Connect Drain* / of the parts, installs in / of the time No tools needed Never needs adjustment Guaranteed to seal properly the first time, every time. 8 8 LESS Certified to comply with ANSI A.8. M989 Rev.. *Your new American Standard faucet is designed to work only with the Speed Connect Drain. Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. Recommended tools Screwdriver INSTALL FAUCET Channel Locks CAUTION Turn off hot and cold water supplies before beginning. Adjustable Wrench Plumbers' Putty or Caulking Tubing Cutter Apply a bead of putty along the edge of the underside of the FAUCET (). Insert FAUCET () and CABLE CONNECTOR () through center hole of mounting surface. From under side of mounting surface thread the two MOUNTING NUTS () onto FAUCET SHANKS (). Center FAUCET () and hand tighten MOUNTING NUTS () to secure FAUCET (). PUTTY (HAND TIGHTEN)

INSTALL POP-UP Remove CLEAR COVER (). Remove CARDBOARD SPACER () from under POP-UP (). Drop BODY () through sink drain hole. Make sure WHITE FOAM GASKET () is under flange of BODY (). REAR OF Note: No plumber s putty or caulk is required. The CABLE ATTACHMENT POINT () must face towards the rear of the. HOLE INSTALL BLACK GASKET Install BLACK CONE GASKET () onto BODY () from below. Note: The flat side of the BLACK CONE GASKET () must face down. FLAT SIDE OF GASKET MUST FACE DOWN INSTALL GRAY LOCKNUT Install GRAY LOCKNUT () onto BODY () from below. Note: The flat side of the GRAY LOCKNUT () must face up. Tighten firmly by hand. No tools are required. Check FLANGE in to ensure that WHITE FOAM GASKET () is fully compressed and not visible. FLAT SIDE OF GRAY LOCKNUT MUST FACE UP FLANGE WHITE FOAM GASKET NOT VISIBLE POP-UP KNOB POP-UP KNOB () must be fully down. DOWN M989 Rev..

ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR () clockwise onto BODY CONNECTION () and hand tighten. Your new POP-UP installation is now complete. Note: Tailpeice on pop-up drain is -/ O.D. -/ O.D. 7 CHECK OPERATION OF POP-UP Operate LIFT KNOB () to verify that STOPPER () opens and closes. Note: If STOPPER () does not open and close properly then refer to the troubleshooting section of these instructions. 8 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY. Connect water supply to INLET SHANKS () with /" IPS FLEXIBLE SUPPLIES () or /8" O.D. BULL-NOSE RISERS (). Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length. Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS. Connect -/ O.D. TAILPIECE () on POP-UP to p trap. COUPLING NUT ON FLEX SUPPLIES /8 O.D. BULL-NOSE RISERS COUPLING NUT WITH FAUCET FLEXIBLE SUPPLIES COMPRESSION NUT FERRULE P TRAP COLD HOT /8 COMPRESSION CONNECTION M989 Rev..

9 TEST INSTALLED FITTING With HANDLES () in OFF position, turn on WATER SUPPLIES () and check all connections for leaks. Ensure that AERATOR () is tightened completely. Operate HANDLES () to allow water flow. 0 CHECK CONNECTIONS Operate POP-UP KNOB () and fill Sink with water. Check that STOPPER () makes a good seal and retains water in Sink. If STOPPER () does not seal properly, please refer to Troubleshooting Guide in these instructions. Release POP-UP KNOB () down and check all drain connections and "P" trap for leaks. Tighten if necessary. SERVICE If Faucet Drips Proceed As Follows: Turn VALVE in OFF position. WASTE OUTLET P TRAP If spout drips, operate HANDLES () several times from OFF to ON position. Do not force-handles they turn only 90. To change direction of handle rotation, proceed as follows: For Products purchased before May 008 Turn VALVE to OFF position. Loosen SET SCREW () and pull HANDLE () off. Remove ADAPTER SCREW () and pull ADAPTER () off VALVE STEM (). For Products purchased after May 008 Turn VALVE STEM () 90 so that flat on VALVE STEM () faces away from the SPOUT (). (Water may turn on) Replace HANDLE () and tighten SET SCREW (). Turn ADAPTER () 90 so that flat within ADAPTER () catches a different flat on the VALVE STEM (). Replace ADAPTER (), ADAPTER SCREW () and HANDLE (). Tighten SET SCREW (). FLAT FLAT AERATOR () may accumulate dirt causing distorted and reduced water flow. Remove AERATOR () and rinse clean. CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. M989 Rev..

Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position: Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode. CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector () counter-clockwise. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration. Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C. Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C. Re-attach the Cable to the Drain Body Connection () by threading the Cable Connector () clockwise onto the Drain Body Connection () and hand-tighten. CAM Fig. C. RE-ATTACH DISCONNECT CAM CAP STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector () counter-clockwise. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration. Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D. Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E. The Stopper can now be removed by lifting it out of the Drain. Fig. F. Fig. D. Fig. E. Fig. F. REMOVE CAM REMOVE CAM CAP M989 Rev..

STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways, Locked Mode (Stopper cannot be removed) or Unlock Mode (Stopper is removable). Locked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G. Fig. G. To install the stopper in Locked mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.fig. G. LOGO Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J. Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not snap into place, then rotate the Cam to make sure it is fully inserted. Fig. K. Re-attach Cable. See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation. Stopper will be in Locked mode and not be removable. LOOP TOWARD REAR OF locked Mode Unlocked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H. Fig. H. To install the stopper in Unlocked mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down. Fig. H. Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J. Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not snap into place, then rotate the Cam to make sure it is fully inserted. Fig. K. Re-attach Cable. See CABLE ADJUSTMENT PROCEDURE in Troublingshooting Guide to complete installation. Stopper will be in Unlocked mode and removable. LOGO LOOP TOWARD FRONT OF 80 Unlocked Mode Fig. J. Fig. K. CAM INSTALL CAM INSTALL CAM CAP M989 Rev..

TIPS FOR REMOVING YOUR OLD : Most existing drains can be removed quickly and easily with only a pair of channellock pliers or a wrench. However, there may be situations where it is difficult to remove your old drain or determine how the drain is disassembled. Depending upon the existing Drain in your sink, it is either removed from above or below the sink. The illustrations below show some typical drain installations and how they are disassembled from the sink. The following tips can help with some of the more common challenges in drain removal: Loosen nuts on P-Trap using channel locks. Suggest spraying nuts with spray lubricant to loosen any corrosion or debris that may have built up. Remove P-Trap half from Tailpiece. Use bucket to catch any residual water in P-trap. Unthread Pivot Rod Nut from Drain Body and remove. Pull Stopper out from Drain Body. For Drains that are removed from below Sink: Loosen Mounting Nut as far down as it will go. Push Drain Body up into Sink and unthread Flange from Drain Body. Remove Drain Body from below sink. For Drains that are removed from above Sink: Unthread Tailpiece from Drain Body. Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks. Suggest spraying nut with spray lubricant to loosen any corrosion or debris that may have built up. Push Drain Body up into the Sink and remove. Note: If Drain body rotates while loosening Mounting Nut, insert a screw driver into overflow hole to prevent Drain Body from rotating while Mounting Nut is removed. Required tools Channel Locks Adjustable Wrench Phillips Screwdriver WHEN IS REMOVED FROM BELOW WHEN IS REMOVED FROM ABOVE METAL OR TWO PIECE BODY METAL BODY WITH TAILPIECE SCREWDRIVER BODY WITH TAILPIECE STOPPER UNTHREAD FLANGE STOPPER METAL BODY STOPPER BODY METAL OR BODY PIVOT ROD NUT MOUNTING NUT PIVOT ROD NUT MOUNTING NUT and GASKET TAILPIECE PIVOT ROD NUT MOUNTING NUT and GASKET TAILPIECE FINISHED WALL P-TRAP HALF FINISHED WALL P-TRAP HALF FINISHED WALL P-TRAP HALF 7 M989 Rev..