Operators Manual. Recirculating Chiller /06/08

Similar documents
Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Operators Manual. Microprocessor Controlled Water Baths /98

MRC 150/300 USER MANUAL. 1 Laird Technologies

Reach ins, Freeezers & Refrigerators Installation & Operation Manual


Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

PolyStat Immersion Circulators

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Operators Manual Refrigerated Recirculating Chillers

¼ to 1HP Chiller Service Manual

ESE Series Cast Iron Sewage Pumps

Automotive Air Conditioning Manifold Gauge Sets

PowerFLO 5800/5900 Series

Installation & Operation Manual Chef Base

User s Manual for Tennessee Chill Box System P/N CB8000

TPHK Series Immersible Pump

Active Controlled Cooling System

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

Users Manual Certified Series Direct Drive Pump 1-7 LPM

BroadBand PowerShield. 20 AHr Battery. User Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

TPAK Series COOLANT PUMP

60 Watt Industrial LED Low Bay Light

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

StormPro BA Series Sump Pump

GARDEN HOSE UTILITY PUMP

TPHK Series Immersible Pump

Air-Operated Waste Oil Drainer

Curved Glass Bakery Cases Installation and Operation Manual

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

Matala. VersiFlow Series. Instruction and Maintenance Manual

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

INSTALLATION AND OPERATION INSTRUCTIONS FUEL LIFTER PUMP MODEL OPT-91UL

110 Volt/12 Volt Portable Inflator

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

ULTRAWARMER HOLDING STATION INSTALLATION & OPERATIONS MANUAL

12 Volt Heavy-Duty Air Inflator

Thermo Fisher Scientific (U.S. and Canada only) 11 (847) (Outside U.S.) (847) (Local)

SAVE THESE INSTRUCTIONS

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Telescoping Pressure Washer Wand 18'

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

BCFS Belt Driven Centrifugal Filtered Supply Fans

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

In-Line Linear Actuator

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

Operation Care Service

G8 Portable Fuel Transfer Pump Owner s Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Pack-Master Air, Spark Resistant Product Manual

User Guide. DuraChill Air- and Water-Cooled 1.5 HP Chillers

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Owner s Manual, Operating Instructions Manual, and Replacement Parts Manual. Lift-Rite Hand Pallet Trucks Model PST Plus

MV Series Motors Operation & Parts Manual

GeyserMax-Flow Series

25 GALLON PORTABLE OIL LIFT

Operator s Manual. LM-Series & MM-Series Compact Chillers

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Use/Installation Guide

SOLAR DASH CHARGING SYSTEM USER GUIDE

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

BARNSTEAD THERMOLYNE ROTO MIX TYPE

Pressure Washer Hose Reel

CTFRP Series Power Supplies

User s Manual and Operating Instructions

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Environmental Series Air Curtains

MANUAL. Use / Installation. Outdoor Access Doors, Dry Storage, and Storage Drawer

BATTERY & STARTER ANALYSER (BSA-12) User Manual

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

2-in-1 Air Operated Waste Oil Drainer

INSTALLATION AND OPERATION MANUAL

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

2SHE Series Direct-Drive Shutter Fans

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual


4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Viking Use/Installation Guide

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

TABLE OF CONTENTS 6.0 WARRANTY

HALLMARK INDUSTRIES INC

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE

AUTOMATIC SUBMERSIBLE UTILITY PUMP

PRE-PLUMBED SEWAGE SYSTEM

SUBMERSIBLE SUMP PUMPS

Transcription:

Operators Manual Recirculating Chiller 110-197 11/06/08

Table of Contents Section 1. General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description of the Recirculating Chiller 1.5 Specification Chart Section 2. Set Up 2.1 Location 2.2 Fluids 2.3 Hosing Section 3. Operation 3.1 Power 3.2 Operation 3.3 Safety Overload Warning Section 4. Maintenance 4.1 Cleaning 4.2 Air Vents (Required Maintenance) Section 5. Troubleshooting 5.1 Unit Disabled 5.2 No pumping 5.3 Insufficient pumping 5.4 Insufficient Cooling Section 6. Service and Technical Support Section 7. Replacement Parts This symbol marks chapters and sections of this instruction manual which are particularly relevant to safety. When attached to the unit, this symbol draws attention to the relevant section of the instruction manual This symbol indications hazardous voltages may be present. Read all instructions pertaining to safety, set up and operation. Proper operation is the users responsibility. 2

Section 1. General Information 1.1 Warranty Thank you for your purchase. We are confident it will serve you for a long time. Our warranty to you is as follows: The manufacturer agrees to correct for the original user of this product, either by repair, or at the manufacturer s election, by replacement, any defect that develops after delivery of this product within the period as stated on the warranty card. In the event of replacement, the replacement unit will be warranted for 90 days or warranted for the remainder of the original unit s parts or labor warranty period, whichever is longer. If a replacement unit is sent, the defective unit must be returned to the manufacturer within 30 days of receipt of the replacement unit. If the defective unit is not received within 30 days, the manufacturer reserves the right to bill for the replacement unit. If this product should require service, contact the manufacturer/suppliers office for instructions. When return of the product is necessary, a return authorization number will be assigned and the product should be shipped, transportation charges pre-paid, to the indicated service center. To insure prompt handling, the return authorization number should be placed on the outside of the package and a detailed explanation of the defect enclosed with the item. This warranty shall not apply if accident, neglect, unreasonable use, improper service caused the defect or malfunction, or other causes not arising out of defects in material or workmanship. There are no warranties, expressed or implied, including, but not limited to, those of merchantability or fitness for a particular purpose that extends beyond the description and period set forth herein. The manufacturer s sole obligation under this warranty is limited to the repair or replacement of a defective product and the manufacturer shall not, in any event be liable for any incidental or consequential damages of any kind resulting from use or possession of the product. Some states do not allow: (1) limitations on how long an implied warranty lasts or (2) exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific rights, and you may also have other rights that vary from state to state. 1.2 Unpacking The Recirculating Chiller is shipped in a special carton. Retain the carton and all packing materials until the unit is completely assembled and working properly. Set up and run the unit immediately to confirm proper operation. Beyond one week, your unit may be warranty repaired, but not replaced. If the unit is damaged or does not operate properly, contact the transportation company, file a damage claim and contact the company where your unit was purchased. 1.3 Package Contents - Recirculating Chiller - Operators Manual - Warranty Card 1.4 Description of the Recirculating Chiller The Recirculating Chiller provides cooling down to -10 C and heating up to 40 C for small-scale applications. It is equipped with an analog controller that provides economical and accurate control with a ±0.2 temperature stability. A magnetic drive centrifugal pump provides flow of coolants to external apparatus. 3

1.5 Specification Chart Temperature range : -10 C to 40 C Temperature stability Controller Readout Readout Accuracy : ± 0.2 C : Analog Controller : Via thermometer : ± 0.2 C Cooling Capacity : @20 C 190 Watts / 648 BTUs/hr @10 C 140 Watts / 478 BTUs/hr Flow rate @ 0 psi Maximum Pressure Overall dimensions Shipping weight @ 0 C 90 Watts / 307 BTUs/hr @-10 C 45 Watts / 154 BTUs/hr : 1.43 gpm, 5.4 lpm : 5 psi : 12 x 11 x 18 in., 30.5 x 28 x 46 cm : 45 lbs, 20.4 kg Catalog number : 120V 082550, 240V 082551 Voltage, Frequency, Current : 120V, 60 Hz, 7 A, 240V, 50 Hz, 3.5 A Circuit Breaker rating : 12 amps Environmental Conditions Environmental Conditions: Indoor Use Only Over Voltage: Category ll Maximum Altitude: 2000 meters Operating Ambient: 5 to 30 C Relative Humidity: 80% for temperatures to 30 C Pollution Degree: 2 Class 1: Residential, Commercial, Light Industrial Class 2: Heavy Industrial Section 2. Set Up 2.1 Location 2.2 Fluids Locate the recirculating chiller on a level surface. Insure easy access to the top cover and position the chiller for unobstructed airflow through the front and rear screens. Avoid voltage drops by using properly grounded power outlets wired with 14 gauge or larger diameter wire. If possible, be close to the power distribution panel. Minimize low line voltage problems by eliminating the use of extension cords. When moving, disconnect from main voltage. Drain liquid from the unit and remove all tubing. Lift and carry by grasping the underside edges of the unit. For most applications above 15 C distilled water is satisfactory. For operation below 15 C the chiller should be protected with an antifreeze solution. Ethylene Glycol (laboratory grade) and water in a 50/50 mixture is satisfactory. Wettable parts are brass, copper, nylon, polypropylene, PVC and Buna N. Only use fluids that satisfy safety, health and equipment compatibility requirements. Caustic, corrosive or flammable fluids must never be used. 2.3 Hosing To maintain a safe work place and avoid leaks, special care should be taken when choosing hoses and connectors for the chiller. 1. Pressure ratings Tubing should be able to withstand the largest pressure that it will encounter. Choose connecting tubing accordingly. 2. Flexible Tubing Avoid tubing that will expand and take up fluid volume when operating at the desired pressure. 4

Section 3. Operation 3.1 Power Plug the unit into a properly grounded outlet with the same voltage and frequency indicated on the identification label (rear of unit). Avoid voltage drops by using properly grounded power outlets wired with 14 gauge or larger diameter wire and if possible, be close to the power distribution panel. The use of extension cords is not recommended; this will avoid low line voltage problems. 3.2 Operation 1. Connection to the chiller can be made with either hoses or pipe. The direction of the flow through the system is controlled by the way the hoses or pipes are connected to the chiller. The inlet draws liquid to the chiller; outlet pumps liquid out to the system. 2. Turn the reservoir cap, on the top of the chiller, counterclockwise and lift up to remove it. Use a funnel to fill the system, but do not replace the cap at this time. Check all hoses and fittings for tightness and be sure there are no bends or crimps in connecting hoses. 3. Plug the chiller into the proper AC outlet. Press the power switch ON. The chiller begins to pump fluid through your system. Check for any possible leaks. Set your desired temperature 4. With the pump running, the fluid level in the reservoir decreases as the closed system begins to fill. Add fluid as needed until the level in the reservoir stops going down. This means that your system is filled and the air has been purged from it. Replace the reservoir cap and turn it clockwise to lock it. 3.3 Safety Overload Warning The compressor in this unit is equipped with an internal safety overload switch. If the unit is turned off, wait 5 minutes before restarting, allowing internal pressure and temperature to stabilize. If the unit is turned on before stabilization, the compressor may not operate. If this happens, turn the unit off again and wait 5 minutes before restarting. Section 4. Maintenance CAUTION: Disconnect power before servicing. 4.1 Cleaning To clean the unit s exterior, use only mild soap and water or a general-purpose cleaner. Be careful to prevent cleaning liquids from entering the inside of the unit. 4.2 Air Vents (Required Maintenance) The refrigeration condenser fins are located just behind the front grill panel. Dust that accumulates reduces the amount of cooling power available. The dust should be blown out periodically with compressed air. All other items are permanently lubricated and need no attention. 5

Section 5. Troubleshooting 5.1 Unit Disabled Check the power to the unit. Be sure the circuit breaker is on. If the unit continues to be disabled request service. 5.2 No pumping Check if the motor is running. Check the fluid level in the whole system to be sure the pump is receiving fluid. Check for blockage within the circulating system. 5.3 Insufficient pumping Check for low line voltage. Hose diameter may be too small. Fluid viscosity may be high. Check for restrictions in connecting tubing. 5.4 Insufficient Cooling Check for low or high line voltage. Check for blocked airflow through ventilation screens. Refrigeration unit should not be operated above 32 C ambient temperature. Such a condition may cause the refrigeration compressor to shut down. Wait 5 minutes between stopping and starting the chiller. Check to see that heat load does not exceed refrigeration capacity. Section 6. Service and Technical Support If you have followed the troubleshooting steps and your chiller fails to operate properly, contact the distributor or manufacturer from whom the unit was purchased. Have the following information available for the customer service person: - Model and Serial Number - Voltage (from back panel label) - Date of purchase and your purchase order number - Suppliers' order number or invoice number A summary of your problem Section 7. Replacement Parts PCB 120V 500-197 PCB 240V 500-213 Heater Assembly 120V 525-448 Heater Assembly 240V 525-464 Fan 120V 215-196 Fan 240V 215-197 Pump 120V 215-265 Pump 240V 215-269 6