Test report No

Similar documents
Test report no

Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Test report No

Classification report No K1

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report no

Test Report No

Test report no

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

FIRE TEST REPORT FH 5154

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Report Test Report

Accessories and workbenches

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

FIRE TEST REPORT FH 5728

EU Mutual Recognition Technical Requirements

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Sound-absorbing spacer Sorp10

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

PRODUCT EVALUATION REPORT

Confirmation: / 22 March 2013

Full extension concealed slide with soft closing and self-closing

FIRE TEST REPORT FH 5078

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

DNVGL-CP-0110 Edition March 2016

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

RENOLIN Xtreme Temp Plus

Test report. About the effect of Lambda System Cleaning Products. No

TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb)

EC type-examination of SITEMA Safety Brakes by DGUV Test

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

Urban Wildfire Interface: Exterior Wall Wildfire Testing

National Standard of People s Republic of China

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT TABLE FOR AMBULANCE STRETCHER

Certificate: / 22 March 2013

Certificate: / 22 March 2013

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

Bruker BioSpin MATCH. Multiple Adjustable Tube Clamp Holder User Manual - Version 005. NMR Solutions. think forward

For BIS Use Only Doc: CED 50(7436) BUREAU OF INDIAN STANDARDS

STS Directory Accreditation number: STS 0630

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Grade A. Evo EV-19 EV-5 EV-4 EV-2 EV-18 EV-14 EV-10 EV-22 EV-20 EV-21 EV-1 EV-23 EV-24 EV-25. Discover more at inscapesolutions.

Title: WF Report No:

The Furniture Retail Quality Group Best Practice Guide

RENEP CGLP. High-performance slideway oils for machine tools, with excellent demulsification properties. Description. Advantages

ISO :2015/DAM 1

Liste der verwendeten Prüfmittel List of used test equipment

BEST HOME FURNISHINGS TERMS, CONDITIONS & WARRANTIES

MITRAS MATERIALS GMBH

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

DEUTSCHE NORM DIN 8077

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Contact person Date Reference Page Michael Lindblad F013838C 1 (1) Sustainable Built Environment

INVESTIGATION OF DENTAL LUBRICANTS

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

PRODUCT INFORMATION RENOLIN DTA. Lubricating and hydraulic oils. Description. Advantages. Application. Specifications

CETOP POSITION PAPER PP 07

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Technical information No. 01. IT systems. The basis for reliable power supply

Certificate: _01 / 29 April 2014

Sequence VH Report Forms Version Conducted For

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

David Fagan, Mobility Manager Paragon Mobility Pty Ltd 3/10 Tapnor Crescent, Brendale, Queensland th December, 2011.

DECLARATION OF CONFORMITY REGARDING RESTRICTIONS OF HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT

Series 240 Pneumatic Control Valve Type DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

The bereal Project - Scientific Highlights

RAUWORKS SCREEN/PARTITION PRODUCT RANGE AND TECHNICAL INFORMATION. Construction Automotive Industry

ANSI/API Standard 607 Sixth Edition 2010 ISO 10497: 2010 Fire Test Certificate

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016

Installation. Active Valve Control Control of Exhaust Valves MB W205 C43 AMG C63 (S) AMG

Flash Point Process Analyzer

BS EN ISO :2006

DECLARATION OF CONFORMITY REGARDING END-OF LIFE VEHICLES (EL V)

Chemical indicators and test devices Benchmarking sterilisation processes.

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1031 issued 23.01.2014 Applicant: VS-Vereinigte Spezialmöbelfabriken GmbH & Co. KG Hochhäuserstraße 8 D 97941Tauberbischofsheim Date of order: 18.12.2013 Date of sampling: no official sampling of the specimen by a representative of Exova Warringtonfire, Frankfurt Date of arrival: 18.12.2013 Date of test: 07.01.2014 Order: Testing of the ignitability according to DIN EN 1021-1 and -2 (April 2006) With assessment according to DIN 66084 Description / designation of the test object ClubLounge, Seat and Couchelement CS CulturalShit / Landscape / Soft Seating Description of the relevant test procedure DIN EN 1021 1 + -2 (April 2006) DIN 66084 Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713

Test report no. 2014-1031 issued 23.01.2014 page 2 of 9 1. Description of the test material 1.1 Details of the customer: ClubLounge, Seat and Couchelement CS CulturalShit / Landscape / Soft Seating Specimen composition: Cover: Stamskin Top (attached sheet) Upholstered Seat: Carpenter RF40065 Upholstered Back: Carpenter RF60045 PP-Slip Sheet: VAL, Karle + Hartmann -> attached data sheets Intende end use of product: Public Building / School 1.2 At the sample preparation by Exova Warringtonfire, Frankfurt determined values: Leather with fabric on foam (Foam an in the description) Imitation leather Fleece Colour: grey white Thickness 1 mm Square weight: 778 g/m² 13 g/m² Imitation leather Fleece Colour: blue white Thickness 1 mm Square weight: 786 g/m² 13 g/m² Before the test, the samples were conditioned at 23 C and 50% humidity.

Test report no. 2014-1031 issued 23.01.2014 page 3 of 9 2. Test results 2.1 Testing of the burning behaviour according to DIN EN 1021-1 (ignition source: cigarette) Leather grey with Fleece Specimen no. 1 2 Smoldering criteria: Unsafe escalating combustion no no Test assembly consumed no no Smolder to extremities no no smolder through thickness no no smolder more than an hour no no More than 100mm from source no no Flaming criteria: Unsafe escalating combustion no no Test assembly consumed no no Flames to extremities no no Flames through thickness no no Flames > 120 seconds no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: The cigarette 1 burn out after 4:30 (min.:sec.) The cigarette 2 burn out after 4:35 (min.:sec.) Test result:

Test report no. 2014-1031 issued 23.01.2014 page 4 of 9 2.2 Testing the burning behaviour according to DIN EN 1021-2 (ignition source: gas flame) specimen no. 1 2 3 Smoldering criteria: Unsafe escalating combustion no no no Test assembly consumed no no no smolder to extremities no no no smolder through thickness no no no smolder more than an hour no no no More than 100mm from source no no no Flaming criteria: Unsafe escalating combustion no no no Test assembly consumed no no no Flames to extremities no no no Flames through thickness no no no Flames > 120 seconds no no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: none Test result:

Test report no. 2014-1031 issued 23.01.2014 page 5 of 9 2.3 Testing of the burning behaviour according to DIN EN 1021-1 (ignition source: cigarette) Leather blue with Fleece Specimen no. 1 2 Smoldering criteria: Unsafe escalating combustion no no Test assembly consumed no no Smolder to extremities no no smolder through thickness no no smolder more than an hour no no More than 100mm from source no no Flaming criteria: Unsafe escalating combustion no no Test assembly consumed no no Flames to extremities no no Flames through thickness no no Flames > 120 seconds no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: The cigarette 1 burn out after 4:40 (min.:sec.) The cigarette 2 burn out after 4:35 (min.:sec.) Test result:

Test report no. 2014-1031 issued 23.01.2014 page 6 of 9 2.4 Testing the burning behaviour according to DIN EN 1021-2 (ignition source: gas flame) specimen no. 1 2 3 Smoldering criteria: Unsafe escalating combustion no no no Test assembly consumed no no no smolder to extremities no no no smolder through thickness no no no smolder more than an hour no no no More than 100mm from source no no no Flaming criteria: Unsafe escalating combustion no no no Test assembly consumed no no no Flames to extremities no no no Flames through thickness no no no Flames > 120 seconds no no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: none Test result:

Test report no. 2014-1031 issued 23.01.2014 page 7 of 9 3. Appearance of the specimen after the test

Test report no. 2014-1031 issued 23.01.2014 page 8 of 9 3.1 Appearance of the specimen after the test

Test report no. 2014-1031 issued 23.01.2014 page 9 of 9 4. Assessment The in chapter one described material fulfils the requirements: according to DIN EN 1021-1 (April 2006): (ignition source: glowing cigarette) according to DIN EN 1021-2 (April 2006) : (ignition source: gas flame ) The tested material passed the requirements to classes P-b and P-c according to DIN 66084 5. Special comment The fire test result is valid only for in section 1 described material. In the composition with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable that the above classification is not any longer valid. The burning behaviour in composition with other materials has to be tested separately. Frankfurt, the 21.08.2014 H. Anders Dipl.-Ing. T. Zachäus Tester in charge Laboratory Supervisor The results of the tests relate only to the behaviour of the test specimen which is designated on the top. Test reports are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire, Frankfurt. The abridged account of a test report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This test report is a translation of the German version 2014-1031 (issued 23.01.2014). In case of doubt only the German version is valid This test report contains 9 pages