Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1031 issued 23.01.2014 Applicant: VS-Vereinigte Spezialmöbelfabriken GmbH & Co. KG Hochhäuserstraße 8 D 97941Tauberbischofsheim Date of order: 18.12.2013 Date of sampling: no official sampling of the specimen by a representative of Exova Warringtonfire, Frankfurt Date of arrival: 18.12.2013 Date of test: 07.01.2014 Order: Testing of the ignitability according to DIN EN 1021-1 and -2 (April 2006) With assessment according to DIN 66084 Description / designation of the test object ClubLounge, Seat and Couchelement CS CulturalShit / Landscape / Soft Seating Description of the relevant test procedure DIN EN 1021 1 + -2 (April 2006) DIN 66084 Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713
Test report no. 2014-1031 issued 23.01.2014 page 2 of 9 1. Description of the test material 1.1 Details of the customer: ClubLounge, Seat and Couchelement CS CulturalShit / Landscape / Soft Seating Specimen composition: Cover: Stamskin Top (attached sheet) Upholstered Seat: Carpenter RF40065 Upholstered Back: Carpenter RF60045 PP-Slip Sheet: VAL, Karle + Hartmann -> attached data sheets Intende end use of product: Public Building / School 1.2 At the sample preparation by Exova Warringtonfire, Frankfurt determined values: Leather with fabric on foam (Foam an in the description) Imitation leather Fleece Colour: grey white Thickness 1 mm Square weight: 778 g/m² 13 g/m² Imitation leather Fleece Colour: blue white Thickness 1 mm Square weight: 786 g/m² 13 g/m² Before the test, the samples were conditioned at 23 C and 50% humidity.
Test report no. 2014-1031 issued 23.01.2014 page 3 of 9 2. Test results 2.1 Testing of the burning behaviour according to DIN EN 1021-1 (ignition source: cigarette) Leather grey with Fleece Specimen no. 1 2 Smoldering criteria: Unsafe escalating combustion no no Test assembly consumed no no Smolder to extremities no no smolder through thickness no no smolder more than an hour no no More than 100mm from source no no Flaming criteria: Unsafe escalating combustion no no Test assembly consumed no no Flames to extremities no no Flames through thickness no no Flames > 120 seconds no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: The cigarette 1 burn out after 4:30 (min.:sec.) The cigarette 2 burn out after 4:35 (min.:sec.) Test result:
Test report no. 2014-1031 issued 23.01.2014 page 4 of 9 2.2 Testing the burning behaviour according to DIN EN 1021-2 (ignition source: gas flame) specimen no. 1 2 3 Smoldering criteria: Unsafe escalating combustion no no no Test assembly consumed no no no smolder to extremities no no no smolder through thickness no no no smolder more than an hour no no no More than 100mm from source no no no Flaming criteria: Unsafe escalating combustion no no no Test assembly consumed no no no Flames to extremities no no no Flames through thickness no no no Flames > 120 seconds no no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: none Test result:
Test report no. 2014-1031 issued 23.01.2014 page 5 of 9 2.3 Testing of the burning behaviour according to DIN EN 1021-1 (ignition source: cigarette) Leather blue with Fleece Specimen no. 1 2 Smoldering criteria: Unsafe escalating combustion no no Test assembly consumed no no Smolder to extremities no no smolder through thickness no no smolder more than an hour no no More than 100mm from source no no Flaming criteria: Unsafe escalating combustion no no Test assembly consumed no no Flames to extremities no no Flames through thickness no no Flames > 120 seconds no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: The cigarette 1 burn out after 4:40 (min.:sec.) The cigarette 2 burn out after 4:35 (min.:sec.) Test result:
Test report no. 2014-1031 issued 23.01.2014 page 6 of 9 2.4 Testing the burning behaviour according to DIN EN 1021-2 (ignition source: gas flame) specimen no. 1 2 3 Smoldering criteria: Unsafe escalating combustion no no no Test assembly consumed no no no smolder to extremities no no no smolder through thickness no no no smolder more than an hour no no no More than 100mm from source no no no Flaming criteria: Unsafe escalating combustion no no no Test assembly consumed no no no Flames to extremities no no no Flames through thickness no no no Flames > 120 seconds no no no Enter "yes" if criteria exceeded or "no" if criteria not exceeded Remarks: none Test result:
Test report no. 2014-1031 issued 23.01.2014 page 7 of 9 3. Appearance of the specimen after the test
Test report no. 2014-1031 issued 23.01.2014 page 8 of 9 3.1 Appearance of the specimen after the test
Test report no. 2014-1031 issued 23.01.2014 page 9 of 9 4. Assessment The in chapter one described material fulfils the requirements: according to DIN EN 1021-1 (April 2006): (ignition source: glowing cigarette) according to DIN EN 1021-2 (April 2006) : (ignition source: gas flame ) The tested material passed the requirements to classes P-b and P-c according to DIN 66084 5. Special comment The fire test result is valid only for in section 1 described material. In the composition with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable that the above classification is not any longer valid. The burning behaviour in composition with other materials has to be tested separately. Frankfurt, the 21.08.2014 H. Anders Dipl.-Ing. T. Zachäus Tester in charge Laboratory Supervisor The results of the tests relate only to the behaviour of the test specimen which is designated on the top. Test reports are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire, Frankfurt. The abridged account of a test report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This test report is a translation of the German version 2014-1031 (issued 23.01.2014). In case of doubt only the German version is valid This test report contains 9 pages