PERUBAHAN SPESIFIKASI TEKNIS PENGADAAN ALAT LABORATORIUM BALAI BESAR POM DI PALEMBANG TAHUN 2012

Similar documents
C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

S 1125 HPLC Pump System

HPLC System S 600 Series

HPLC SYSTEM S 500 SERIES

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

NEW HPLC - SYSTEM LINE

Liquid Chromatography

END OF YEAR WAREHOUSE CLEARANCE SALE! Ex Demo & Superseded Instrumentation

LM series. LE series. DK series. TS series. BH BU BL BT series. GC series. DS series. LR series

Cassia Siamia BLOOD BANK REFRIGERATED CENTRIFUGE MP 6000 R. Technical Data (MP 6000 R)

Agilent 7693A Automated Liquid Sampler

Environmental/Analytical LabCivil Engineering Lab Equipment

Agilent 7693A Automated Liquid Sampler

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

Determination of Sudan Dyes I IV in Curry Paste

ACQUITY UPLC I-Class System with 2D Technology

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Liquid Chromatography LC Consumables SSI-LC

E v a p o r a t o r s

Quick Reference Guide. Supplies for Waters HPLC Systems

HyperShear TM HPLC Mixers

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Vacuum Evaporator with optional separate remote controller with or without shaking feature page 2 page 3 page 3. Incubator with cooling feature

RALF At a glance. Bioengineering RALF essentials. General

GENERAL PURPOSE INCUBATOR

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

Shaking Incubators & Shakers

GENERAL CATALOG L.TEX CORPORATON

General Pricelist (EXW Baar or Brno, reference price in EUR, prices and specifications are subject to change)

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup (2700 for 50Hz models)

The Only No Compromise

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Date and Time of Pre Bid Meeting November 22, 2016 at a.m

Technical Procedure for Gas Chromatography (GC-FID)

Mistral LC-MS Evolution Specification

Multi-Functional Digital Feedback Controller incorporated into all Digital Instruments

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

BENCHTOP SHAKING INCUBATOR

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Competence in Plastic Labware

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Incubators. Incubators

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Corning Brand Equipment Product Selection Guide

Pursuing high precision, speed, and ease of use

889 IC Sample Center

Vessels and Distillation Equipment

ACQUITY UPLC I-Class System Specifications

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Accurate to 0.1 NIST Traceable Advanced PID Algorithm USB Port Free datalogging/control software

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Refrigerators/Freezers

new yellow MAG HS 10 / HS 7 / HS 4 New magnetic stirrers with heating 769,00 EUR 605,00 EUR 544,00 EUR FRANCE

Hitachi High-Speed Amino Acid Analyzer

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

PETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis

Agilent 1100 Series Capillary LC System. System Manual

HyperShear TM HPLC Mixers

Easy to use! Smart, practical instruments which are robust and reliable, and fit on any laboratory bench. STIRRERS DRY BATH INCUBATORS MIXERS

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Model ED 400 Drying and heating chambers Classic.Line with natural convection

ZINSSER-MINILAB A Complete Laboratory in a Case

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Lab Overview 2017 /

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Guaranteed Technical Particulars(GTP) Deviation/Remarks Specify if any. Computerized Motor testing system suitable to test LV 3 phase motors

Heavy Duty Orbital Shakers

Product Overview of GYROZEN Centrifuges

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

ISO Certified Products CE-Marked Products CE-MDD Marked Products Validation (IQ, OQ & PQ) Service

Heating oven with mechanical control

HyperShear TM HPLC and UHPLC Mixers

Since Discover economical and innovative solutions.

Specifications for lab instruments

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

VERITY Purification Systems Build the perfect system to fit your research

PATROL UPLC Process Analysis System for Production

B/R Vacuum Distillation ASTM D1160. Fully Automatic Vacuum Distillation According to D1160

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P.

Accurate to 0.1 NIST Traceable Advanced PID Algorighm USB Port Free datalogging/control software. Controllers I N S C O N TA G N

Hybridization Ovens. Versatile instruments for common hybridization applications

Elmasonic S Ultrasonic cleaning units. The sum of all possibilities

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

2014 Buick Encore. Fig. 2: Replacing Measured Compressor Oil Courtesy of GENERAL MOTORS COMPANY

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Heating chamber with mechanical convection

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Heating chamber with mechanical convection

4x750 ml Ventilated Refrigerated. Centrifuges

Transcription:

PERUBAHAN SPESIFIKASI TEKNIS PENGADAAN ALAT LABORATORIUM BALAI BESAR POM DI PALEMBANG TAHUN 2012 No Nama Barang dan Spesifikasi Teknis 1 AUTOCLAVE UNIT 2 Dimensions : (W x H x L) : approximately 65 x 120 x 65 cm Chamber size : ( ɸ x H ): approximately 40 x 80 cm Capacity : minimal 100 Liter Power source : 220-240 Volt, 50-60 Hz Power consumption : 4 KW or lower Sterilization temperature range : 105 C to 135 C, or wider Chamber material : Stainless steel SUS 304 Max allowable pressure : 0.26 Mpa Temperature display range : 5 C to 135 C, or wider Sterilisation Time Range : 1 to 250 minutes, or better Pressure gauge : 0 to 0.4Mpa, or better Accecories : Stailess steel wire basket 3 pcs in different types, heater cover, drain hose, exhaust hose, drain bottle, caster stoppers 2 AUTOINJECTOR AND AUTOSAMPLER for Agilent Technologies 7890 A Gas Chromathography 7693a Autoinjector, include : Transfer Turret : 16-Sample Turret : Mounting post : Parking post for GC : Syringe 10 µl : Solvent Bottles 3 CENTRIFUGE Speed control : up to 8500 rpm, or higher (by fixed angle rotor) Max Capacity : 300 ml (6x50) or better Force range/rcf : Up to 4600 xg, or better (by fixed angle rotor) Running time : 1-99 min or better Display : LCD digital Power consumption : 220-240V / 50-60 Hz Timer feature : : hold, at-speed, regular timed mode Noise : < 65dBA Control : microprocessor Accessories : Polypropilen conical bottom centrifuge tube with cap 50 ml : 10 pcs : Wood Test tube rack hole ɸ 18 mm @ 3 pcs : Fixed Angle Rotor capacity 12x15 ml : Fixed Angle Rotor capacity 6x50 ml Included of : Instalation 4 CONDUCTIVITY METER Temperature range : -5 to 100 o C or wider Conductivity range : 0 to 3000 ms/cm, or wider Conductivity accuracy : ± 0.5 % or less Conductivity Resolution : adjustable Sensor (s) : Conductivity cell, includes flow cell 0.01 to 300 µs/cm or Power Supply : wider 220-240 V, or Universal AC power adapter, or 4 x 1.5V AA Asesories : 100 µs/cm conductivity standard (5 x 60 ml bottles) : Swing arm electrode stand 5 DENSITOMETER/ TLC SCANNER Object formats : up to 200 200 mm Light sources : deuterium, halogen-tungsten

: Deuterium lamp : 190-400 nm or better : Halogen tungsten lamp: 390-900 nm or better Data step resolution : 25 200 µm or better Monochromator : 1200 lines/mm or better bandwith selectable : 5/20 nm or better reproducibility of wavelength : 0.2 nm or better setting accuracy : 1 nm or better Maximum speed of spectra : 100 nm/s at oversampling rate 40/nm or greater recording Scanning speed : 1 100 mm/s, Fully automatic scanning Detector : Reflectance mode : Two matched broadband photomultiplier, multialkali type : Spectral sensitivity : 185-850 nm or better Voltage : 220/240 V, 50/60 Hz Workstation (hardware) : computer, processor intel pentium IV 2.8 GHz, DDR 2 G : Pentium IV core 2 duo, Windows XP, DDR 2 GB, Hard Disk 160 GB, RAM min 2 GB, : CDROM Drive, DVD/CD Writer, LCD Monitor17", VGA card min 128 MB, Laser-jet printer. Workstation (soft ware) : Compatible with Windows XP 2000/ Windows 7 : TLC Scanner Including 027.6312 equilink : Planar Chromatography Manager : Qualification & Self Test : Quantitative Chromatogram Evaluation : Spectrum Library 6 DISTILLATION SYSTEM Standard configuration : Automatic addition NaOH, programmable reaction and distillation time, Protection door with safety switch Distillation time : 2-4 minutes or better Recovery rate : up to 99.5 % or better Reproducibility : ± 1% or less Detection limit (N) : 0.1 mg or lower Steam regulation : 30-100 % or better Power Supply : 220-240 V, 50-60 Hz, 1600 watts or lower Accessories : Tubing Set Complete Set of storage tanks : 1 set Kjedalterm digestion tube 250 ml : 6 pcs UPS 5 KVA 1 Phase 1 unit Tool Kit Include : Instalation (IQ, OQ, PQ) Training Uji Fungsi Guarantee min. a year Original Manual operation (English/Indonesian) 7 DISINTEGRATION TESTER WITH TWO STATION Display : LCD Reciprocating mechanism - Speed : 30 ± 1 strokes/ min - Stroke : 55 mm Volume of waterbath : 9 Liters Volume of beaker : 1 Liters Power supply : 100-240V/ 45-65Hz, 75 watts or lower Complete : Tester unit : Plexyglass water bath : Thermostat 25-40oC : Test vessel : Basket with disk : Power cable : Printer, connection cable and printer paper 8 FURNACE Chamber capacity : 14 liters Temperature max : 1200 o C or better Power: : 220-240 V/50-60 Hz. - 3100 Watts or lower Accessory : Stainless Stell Shelf, 2 buah Include : : Instalation

9 HEATING MANTLE Capacity : 1000 ml Temperature range : up to 450 o C Power Supply : 220-240V, 50-60 Hz, 300 Watts or lower 10 HOT PLATE Plate dimension : : 30 x 60 cm or greater Heating material : Aluminium Temperature range : : up to 370 oc or better Power : 220-240 V/50 Hz., 3200 Watts or lower include : Instalation 11 HOT PLATE + STIRER Plate dimension : : 18 x 18 cm or greater Heating material : Ceramic Temperature range : : up to 540 o C or better Display : : digital Speed range : 60-1200 rpm or wider Stirring Volume : up to 10 L or greater Power supply : 220 V / 50Hz. 1200 Watts or lower Assesories : Magnetic stirrer bar 5 x 30 mm : 1 pcs : Magnetic stirrer bar 5 x 40 mm : 1 pcs : Magnetic stirrer bar 5 x 50 mm : 1 pcs include : 12 HOT PLATE + STIRER Plate dimension : : 26 x 26 cm or greater Heating material : Ceramic Temperature range : : up to 400 o C or better Temperature display : : digital Strirring speed :. : 60-1200 rpm or wider Power : 220 V / 50Hz. 1600 Watts or lower Assesories : Magnetic stirrer bar 5 x 30 mm : 1 pcs : Magnetic stirrer bar 5 x 40 mm : 1 pcs : Magnetic stirrer bar 5 x 50 mm : 1 pcs include : 13 HOMOGENIZER Speed : up to 26,000 rpm or better Power supply : 100-240 Volt, 40-70 Hz, 130 watts or lower Viskositas : Allows for any viscosity up to 5,000 mpa s Max Quantities : up to 2,0 L Accessories : Plate stand : 2 cross sleves : vessel holding bracket Include : : Instalation 14 HPLC UV-Vis DETECTOR Pompa : Binary and Quartenary Pump, Dual-plunger reciprocating Tipe pump Flow rate range : 0,1-5 ml/min or wider Flow rate accuracy : ± 2% or less Pressure operating Range : up to 375 bar or better Vesel : minimal 4 Detector Detector UV Vis : Lamp : D2 lamp, W lamp, Hg lamp (for wavelength check) wavelength range : 200-600 nm or wider wavelength Accuracy : 1 nm or less Degasser : 1 unit Column Oven

temperature Range : 20-65 o C or wider Manual Injector 1 unit Data Prosessor : Min Pentium IV core 2 duo, Windows XP, Hard disk min 120 G, RAM min 1 G, DVD/VCd Writer, LCD monitor 18", laser jet printer : Software compatible for data acquisition, analysis, storage Accecories Dust cover : 1 set Tools kit : 1 set Column C 18, 5 µm x 25 cm : 2 pcs MICRO SYRINGE 100 ul : 1 pcs Sample filter : 1 set UPS 10KVa, 1 phase : 1 pcs Include: : Instalation (IQ, OQ, PQ) 15 HPLC UV-Vis Detector with Autosampler Pompa : Binary and Quartenary Pump, Parallel-type double plunger or Tipe equivalent Flow rate range : 0,1-5 ml/min or wider Flow rate accuracy : ± 1% or less Flow rate Presisi : 0.1% RSD or better Pressure operating Range : up to 400 bar or better Vesel : minimal 4 Detector : Detector UV Vis Lamp : Deuterium (D2) lamp wavelength range : 200-600 nm or wider wavelength Accuracy : 1 nm or less bandwith : 8 nm Degasser : 1 Unit Column Oven temperature Range : 20-65 o C or wider temperature Precision : ± 1% or less Auto sampler : Injection Vol range : up to 100 ul or better Injection Volume accuracy : ± 1% or less Number of sampel : min 100 sampel @ 1,5 ml : the manual injector also can use if we release the automatic injector (not use autosampler) Data Prosessor : Min Pentium IV core 2 duo, Windows XP, Hard disk min 120 G, RAM min 1 G, DVD/VCd Writer, LCD monitor 18", laser jet printer : Software compatible for data acquisition, analysis, storage Accecories : Dust cover : 1 set Tools kit : 1 set Column C 18, 4,6 µm x 25 cm (tahan terhadap tekanan sampai dengan 300 bar atau lebih) : 2 pcs MICRO SYRINGE 100 ul : 2 psc Maintanace Kit : 1 set Reservoir tray : 1 set Auto rinsing Kit : 1 set Sample filter : 1 set sample vial 1,5 ml : 2 Pck (100pcs/pck) UPS 10KVa 1 phase : 1 pcs Include : Instalation (IQ, OQ, PQ) 16 HPLC UV-Vis and Flourosence Detector with Autosampler Pompa : Binary and Quartenary Pump, Dual-plunger reciprocating Tipe pump Flow rate range : 0,1-5 ml/min or wider Flow rate accuracy : ± 2% or less Pressure operating Range : up to 375 bar or better Vessel : minimal 4 solvent Detector : Fluorescence Detector light Source : Xe lamp, Hg lamp

Wavelength Range : 200-650 nm or wider Wavelength Accuracy : ± 3 nm or less Detector UV Vis : wavelength range : 200-600 nm or wider light Source : D2 lamp, W lamp, Hg lamp Wavelength Accuracy : ± 1 nm or less Degasser : Column Oven temperature Setting Range : 20-65 o C or better Temperature accuracy: : ± 0.1 C or less Auto sampler Injection Vol range : 1-50µl or wider Number of Sample : up to 200 vials (@ 1,5 ml) Manual Injector : Rheodyn Injector Data Prosessor : Min Pentium IV core 2 duo, Windows XP, Hard disk min 120 G, RAM min 1 G, DVD/VCd Writer, LCD monitor 18", laser jet printer : Software compatible for data acquisition, analysis, storage Accecories Dust cover : 1 set Tools kit : 1 set Column C 18, 5 µm, 25 cm : 2 pcs MICRO SYRINGE 50 ul : 1 pcs Sample filter : 1 set UPS 10KVa, 1 phase : 1 pcs sample vial 1,5 ml : 1 set Cap with hole : 1 set Septum : 1 set Include : Instalation (IQ, OQ, PQ) 17 HPLC Photo Diode Array Detector with Autosampler Pompa : Binary and Quartenary Pump, Parallel-type double plunger or Tipe equivalent Flow rate range : 0,1-5 ml/min or wider Flow rate accuracy : ± 1% or less Flow rate Presisi : 0.1% RSD or better Pressure operating Range : up to 400 bar or better Vesel : minimal 4 Detector Photodiode Array Detector Light source : Deuterium (D2) lamp, Tungsten (W) lamp Wavelength range : 200-800 nm or wider Wavelength accuracy : ± 1nm or less Wavelength precision : ± 0.1nm or less Degasser Column Oven temperature Range : up to 85 C or better temperature Precision : ± 1% or less Auto sampler Injection Vol range : up to 100µL Injection Volume accuracy : ± 1% or less Number of sampel : minimal 100 vial @ 1,5 ml : Note : the manual injector also can use if we release the automatic injector (not use autosampler) Data Prosessor : Min Pentium IV core 2 duo, Windows XP, Hard disk min 120 G, RAM min 1 G, DVD/VCd Writer, LCD monitor 18", laser jet printer : Software compatible for data acquisition, analysis, storage Accecories Dust cover : 1 set Tools kit : 1 set Column C 18, 4,6 µm x 25 cm : 2 pcs (tahan terhadap tekanan sampai dengan 300 bar atau lebih) MICRO SYRINGE 100 ul : 2 pcs Maintanace Kit : 1 set Reservoir tray : 1 set Auto rinsing Kit : 1 set Sample filter : 1 set sample vial : 2 Pck (100pcs/pck) UPS 10KVa, 1 ph : 1 Pcs Include : Instalation (IQ, OQ, PQ)

18 INKUBATOR Temperatur range : from -12 C up to 60 C or wider Volume : minimal 400 Liters Control LED with microprocessor, show the actual temp, adjustment temp, and timer, etc Material : Main body stainless Stell with double locking, inner door: glass Ventilation : adjustable Power Supply : 220-240 V/50-60 Hz, 750 watts or lower Dimension (W x H x L) : Approximately (120x150x65) cm Accessories : Shelves stainless steel 3 pcs : Stabilizer compatible Include 19 LABORATORY BLENDER Speed : up to 22.000 rpm or better Capacity : ± 1 Liter Container : : Stainless steel with handle and two piece vinyland styrene lid Power : 220-240 Volt, 50/60 Hz 20 LABORATORY REFRIGERATOR External Dims. (WxDxH) : (50-80)x(75-100)x(180-200) cm Volume : 600 L Drawers : Minimal 5 (solid roll-out) Doors : 1x double pane glass doors, Self closing Insulation : CFC-free, rigid polyurethane foamed-in-place or better Cooling Method : Forced air circulation with single fan Defrost Method : Forced type (cycle defrost system) : Full automatic Temperature Control : Microprocessor controlled on/off type : 1 o C step setting Temperature type (1 o C step resolution) Safety : High and low temperature protection circuit, Temperature lock, High and low temperature alarm Power Supply : 1 phase, 220 V/50-60 Hz, 200 W Accessories : Stabilizer 500 VA Include 21 MVU dan HVG for Shimadzu AA-6300 Mercury Vapour Unit for Shimadzu AA-6300 complete with accessories Type : MVU-1A Brand : SHIMADZU Vaporization method : Reduction and vaporization using reducing agent Measurement method : recirculation Air flow rate : 6 L/min Flow cell : Optical path length up to 100 mm Sample volume : 250 ml max Exhaust contamination prevention : Adsorption trapping in mercury trap bottle Complete with : Holder for gas flow cell : Gas Flow cell/long Abs. Cell for MVU-1A : Mounting Adaptor for AA-6300 : Step down Transformer 2 A ( from 220 V to 100 V) Hydride Vapour Generator for Shimadzu AA-6300 complete with accessories Type : HVG-1 Brand : SHIMADZU Method of Hydride Derization : Continuous Flow Method Sample Consumption : 0 to 7 ml/min, variable Reagent consumption : 0 to 2.5 ml/min, variable Atomizer : Heated absorbtion cell (Heated by Air-C2H2 flame in standard system) Carrier gas : Ar pressure: 3,2 kg/cm 2, consumption:70ml/min Complete with : Nozzle Assy for connected with Auto Sampler : Gas Argon UHP with cylinder : Pressure Regulator Ar Accessories : Hollow catode lamp for Mercury (Hg) 2 set : Hollow catode lamp for Arsenic (As) 2 set

: Standard solution Arsenic (As) 1 set : Standard Solution Mercury (Hg) 1 set Include: : Instalation (IQ, OQ, PQ) 22 ORBITAL SHAKER Motion : orbital Rotation speed (rpm) : 30-300 rpm or wider Timer : minimal 60 min or greater Power : 110/220V, 50/60Hz, 30W or lower Speed control : Digital Automatic Feedback Controller Accessories : Platform with Universal sping rack : Platform with 9x250 ml flask clamps : 1 unit 23 ph METER ph Range : 0,00-14,00 or wider Power Supply : 100-240 V/ 40-70 Hz, with plug adaptor Display : LCD ph Relative accuracy : ± 0.005 or less ph Resolution : variable 0.001 / 0.01/0.1 mv Range : -1800 to 1800 or wider mv Relative Accuracy : ± 0.2 or less mv Resolution : 0.1 or better Temperature range : 0 to 100 0C or wider Complete : workstation with integrated stirrer, : Technical buffer ph = 4,00 at 25 o C (ED min. a year) : Technical buffer ph = 7,00 at 25 o C (ED min. a year) : Technical buffer ph = 10,00 at 25 o C (ED min. a year) Include & Training 24 TIMBANGAN SEMI MIKRO UNIT 2 Maximum Capacity : 100g Readability : 0.01 mg Repeatability : 0.05 mg Linearity : 0.1 mg Power supply : 220-240 Volt, 45-60 Hz or AC Adapter 120 V Display : LCD Acessories : Stabilizer 500 ma 25 MEJA TIMBANGAN Size : 90 x 60 x 12 cm, tinggi meja 80cm Material : non magnetic material as fiber glass, : carbon tube use material diameter of approximate 10-15mm maximum distance : 30cm between bars. Complete with : dumping pad, vibration lower then 15 Hz Include : : Instalation 26 ULTRA LOW TEMPERATURE FREEZER Temperature range : up to -80 C or better Capacity : Approx. 80 L Storage capacity : Approx 2 box: min 40 pcs. Power supply : 220-240 V/ 50-60 Hz, 340 W or lower Display : digital display Refrigerant : HFC Mixed Refrigerant Accessories : Inventory Rack 6 Pcs 27 ULTRASONIC CLEANER Capacity : min 20 L Display : LCD Timer : 1-99 minutes or better Tank Temperature : Ambient - 50 o C or wider Power Supply : 100-240 V/40-50 KHz

28 VORTEX MIXER UNIT 3 Stirring speed: : up to 3000 rpm or better Operational mode: : Continuous or automatic Power supply: : 100 240 V / 50 60 Hz, 15 watts or lower Complete with : a standard cup for single test tube. Speed Control : Electronic Accessories : Costumizable soft foam top (1 set), Foam stand for microtiter (1 set) 29 WATERBATH Capacity : 14 Liter Temperature range : (5 C ambient) up to +95 C or wider Controller : microprocessor PID Timer : 1 to 99 min or better Power Supply : 220-240 V, 50-60 Hz, 1.800 W or lower Material : Stainless steel Dimention casing : l x w : approximately 60 x 45 cm Accessories : : Flat stainless steel cover with openings and concentric ring sets (6 openings / 87 mm diameter) : Gable stainless steel cover mounted for condensate drainage : Water level control 30 WATERBATH Capacity : 29 Liter Temperature range : (5 C ambient) up to +95 C or wider Controller : microprocessor PID Timer : 1min to 99 hours or better Material : Stainless steel Power Supply : 220-240 V, 50/60 Hz, 2400 W or lower Dimention casing : l x w : approximately 80 x 50 cm Accessories : : Flat stainless steel cover with openings and concentric ring sets (8 openings / 107 mm diameter) : Gable stainless steel cover mounted for condensate drainage : Water level control Catt: Perubahan terdapat pada Spesifikasi dengan tulisan berwarna merah