MOTOR, SERVO, & FEEDBACK CABLES

Similar documents
www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

Selection table for heat-resistant cables

Photo: HELUKABEL. Trailing Cables G 1

Selection table for data and computer cables

Includes Hybrid Cables for SICK HIPERFACE DSL and HEIDENHAIN HMC6. NEW! TOPSERV PUR Single CABLES ACC. TO CROSS SECTION & ACC.

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

The BIG names in Cable for the BIG jobs in Cable. Flexible Cables

The BIG names in Cable for the BIG jobs in Cable. Flexible Cables

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 115 CY

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Approvals (Norm references)

CF270.UL.D.

PUR c-track cables For highest requirements

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

Industrial Cables and Wires

Telephone Cables Fire Warning Cables

Ship Wiring and Marine Cables

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

INFORMATION. Hybrid cables. Description

H05 V-K PVC-Single Cores, fine wire stranded

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

14 HH EAC/CTP CE RoHS-II conform

Data sheet chainflex CF210.UL

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

flame Retardant overall screened Instrumentation cables (Multicore)

Technical attributes

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

DNV-GL HH CE RoHS-II conform

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

Data sheet chainflex CF270.UL.D

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PVC motor cables unshielded

Industrial Ethernet Cables

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

Data sheet chainflex CF8821

Cables for Airport Equipment

CRANE, CONVEYOR, LIFT & REELING CABLES

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

ÖLFLEX CLASSIC 110 H Info Benefits

Due to the increasing data transfer between machines and equipment the higher standards in data and computer applications are necessary.

Data sheet chainflex CF886

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Cables for Railway Technology

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

Selection table for single conductors

Data sheet chainflex CF240

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

20 HUBER+SUHNER RADOX SOLAR

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

Data sheet chainflex CF140.UL

Data sheet chainflex CF6

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

Power & Control Cable IEC

Cable Assemblies according to Bosch Rexroth Standard

Ph: Product Catalogue Industrial Cables Hazardous area equipment Cable termination

Technical Data Sheet Shielded (CY) PVC Control Cable

Global data. Electrical parameters

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Data sheet chainflex CFSOFT1

LUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions

Power & Control Cables

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...

Data sheet chainflex CF881

BlueLine Cables for Shipbuilding

Data sheet chainflex CF886

Installation Devices 4

LÜTZE Machine and System Installation Technology

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Power & Control Cable IEC

Technical Data Sheet Shielded (CY) PVC Control Cable

CF11.LC / CF11.LC.D CF14.CAT5

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Technical Data Sheet Unshielded (YY) PVC Control Cable

Cable systems We offer you the essential components for a future-oriented e-mobility.

Data sheet chainflex CF5

Cables for cable carriers and reels SYSTEMS IN MOTION

Technical Data Sheet Shielded (CY) PVC Control Cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

THERMOCOUPLE CABLES THERMOELECTRICITY

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

Transcription:

MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free UV-resistant Outdoor use Drag chain Colored cores/vde 093 Screened/shielded HAR/VDE REG no./vde UL/CSA Page D TOPFLEX 00-PVC -5 to +80-0 to +80 0./ kv 7.5x x 97 TOPFLEX 00-C-PVC -5 to +80-0 to +80 0./ kv 7.5x x X 98 TOPFLEX -PUR -30 to +80-0 to +80 0./ kv 7.5x x X X X X 99 TOPFLEX -C-PUR -30 to +80-0 to +80 0./ kv 0x 5x X X X X X 00 TOPSERV 0 / 0-30 to +80-0 to +80 0./ kv 7.5x x X X X X X 0 Feedback cable -5 to +70-30 to +80 350 0x X X 0 Feedback cable PUR -30 to +80-0 to +80 50 0x 5x X X X X X 03 TOPFLEX - EMV-YSLCYK-J +5 to +70-0 to +70 0./ kv 0x 0x X X 0 TOPFLEX - EMV-3 PLUS YSLCY-J +5 to +70-0 to +70 0./ kv 0x 0x X X 05 TOPFLEX - EMV-UV-YSLCYK-J -5 to +70-0 to +70 0./ kv 0x 0x X X X X 0 TOPFLEX - EMV-UV-3 PLUS YSLCYK-J -5 to +70-0 to +70 0./ kv 0x 0x X X X X 07 TOPFLEX - EMV-UV-XSLCYK-J -5 to +90-0 to +90 0./ kv 0x 0x X X X X 09 TOPFLEX - EMV-UV-3 PLUS XSLCYK-J -5 to +90-0 to +90 0./ kv 0x 0x X X X X TOPFLEX - EMV-UV-XSLCH-J -5 to +90-0 to +90 0./ kv 0x 0x X X X 3 TOPFLEX - EMV-UV-3 PLUS XSLCH-J -5 to +90-0 to +90 0./ kv 0x 0x X X X 5 TOPFLEX MOTOR 09-5 to +70-0 to +80 0./ kv 0x 0x X X X X X 7 The selection table is intended as an initial orientation. Please see the relevant page of the catalogue for detailed information on the product properties. 95

SELECTION TABLE - DRAG CHAIN CABLES PUR motor & servo cables for drag chains Max. movement distance in m (0 m up to 5-cores) Max. speed (m/s) Min. bending radius - flexing (D=outerØ) Max. acceleration (m/s ) Max. cycles Material Nominal voltage U 0 /U / Operating voltage Approvals Temperature ( C) - flexing Page UL/CSA equivalent TOPFLEX -PUR 30 7.5 x D 50 Mio PP/PUR 00/000V -30 to +80 99 3 TOPFLEX C-PUR 30 0 x D 50 Mio PP/CU/PUR 00/000V -30 to +80 00 37 TOPSERV 0 30 7.5 x D 3 0 Mio PP/CU/PUR 00/000V -30 to +80 0 8 TOPSERV 0 30 7.5 x D 3 0 Mio PP/CU/PUR 00/000V -30 to +80 0 8 PUR feedback cables for drag chain cables Tachofeedback-cable-C-PUR 30 0 x D 50 9 Mio PP/CU/PUR 50V -30 to +80 03 70 Incremental encoder cable C-PUR 30 0 x D 50 9 Mio PP/CU/PUR 50V -30 to +80 03 70 TOPFLEX -PUR 30 0 x D 50 9 Mio PP/CU/PUR 350V -30 to +80 03 70 A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel and professionally installed (see the installation manual: cable installation in drag chains, see pages 03 and 037). The selection table is intended as an initial orientation. Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains, see pages 030 and 03. 9

TOPFLEX 00-PVC motor power supply cable 0,/kV, meter marking Special PVC-insulated sheathed cable adapted to DIN VDE 093, 095 flexing -5 C to +80 C fixed installation -0 C to +80 C Nominal voltage U0/U 00/000 V Test voltage 000 V Breakdown voltage min. 8000 V min. 0 MOhm x km flexing 7,5x cable Ø fixed installation x cable Ø Radiation resistance up to 80x0 cj/kg (to 80 Mrad) DIN VDE 095 cl.5, fine-wire, IEC 08 cl.5 Core insulation of PVC Core identification to DIN VDE 093 black cores with continuous white numbering GN-YE conductor Cores stranded in layers with optimal lay-length Outer sheath of special PVC Sheath colour grey (RAL 700) PVC outer sheath: extensively oil resistant Chemical Resistance - see table Technical Informations Tests PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) For use in drag chains, we recommend our versions TOPFLEX -PUR and TOPFLEX -C-PUR screened analogue type: TOPFLEX 00-C-PVC, confer page 98 As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible installation for medium mechanical loads in dry, damp and wet environments. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. D Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight mm weight 80 G,5 9, 58,0 30,0 8 G 5 7, 90,0 805,0 8 G,5, 95,0 0,0 87 G 35 30,0 3,0 00,0 8 G 3,0 5,0 330,0 88 G 50 35,8 90,0 900,0 83 G,5 3,0 5,0 0 89 G 70 0,9 0,0 050,0 /0 8 G 0 8, 38,0 0,0 8 85 G 95, 38,0 550,0 3/0 85 G,3 5,0 00,0 855 G 0 5, 08,0 7000,0 /0 Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 97

TOPFLEX 00-C-PVC motor power supply cable 0,/kV, EMC prefered type, meter marking Special PVC-insulated sheathed cable adapted to DIN VDE 093, 095 flexing -5 C to +80 C fixed installation -0 C to +80 C Nominal voltage U0/U 00/000 V Test voltage 000 V Breakdown voltage min. 8000 V max. 50 Ohm/km min. 0 MOhm x km flexing 7,5x cable Ø fixed installation x cable Ø Radiation resistance up to 80x0 cj/kg (to 80 Mrad) DIN VDE 095 cl.5, fine-wire, IEC 08 cl.5 Core insulation of PVC Core identification to DIN VDE 093 black cores with continuous white numbering GN-YE conductor Cores stranded in layers with optimal lay-length Inner sheath of Tinned copper braided screen, 85% coverage Outer sheath of special PVC Colour grey (RAL 700) PVC outer sheath largely oil resistant, for Chemical Resistance - see table Technical Informations Tests PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) For use in drag chains, we recommend our versions TOPFLEX -PUR and TOPFLEX -C-PUR unscreened analogue type: TOPFLEX 00-PVC, confer page 97 As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible installation for medium mechanical loads in dry, damp and wet environments. To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight mm weight 90 G,5,8 99,0 50,0 9 G 5 3,7 9,0 90,0 9 G,5 3,8 9,0 30,0 97 G 35 3,5 80,0 55,0 9 G 5,7 3,0 530,0 85 G 50 0,7 370,0 335,0 93 G 7,3 3,0 0,0 0 857 G 70,0 357,0 00,0 /0 9 G 0,5 59,0 050,0 8 858 G 95 5,3 00,0 00,0 3/0 95 G, 807,0 5,0 859 G 0 5, 53,0 735,0 /0 Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 98

TOPFLEX -PUR motor power supply cable 0,/kV, cable for drag chain, halogen-free, meter marking D Special-PUR drag chain cable adapted to DIN VDE 093, 095, 050, DIN VDE 085-55- / DIN EN 5055- flexing -30 C to +80 C fixed installation -0 C to +80 C Nominal voltage U0/U 00/000 V Test voltage 000 V min. 0 MOhm x km Min. bending radius flexing 7,5x cable Ø fixed installation x cable Ø DIN VDE 095 cl., extra fine-wire, BS 30 cl., IEC 08 cl. Core insualtion of PP Core identification to DIN VDE 093 black cores with continuous white numbering GN-YE conductor Cores stranded together with optimal lay-length and stabilising filler Fleece wrapping facilitates sliding Outer sheath of PUR Sheath colour grey (RAL 700) Adhesion-free, extremely abrasion resistant, halogen-free, resistant to hydrolysis and microbial attack resistant to UV-radiation, oxygen and ozone G = with green-yellow conductor For extreme applications extending beyond standard solutions we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Please observe applicable installation regulations for use in energy supply chains. screened analogue type: TOPFLEX -C-PUR, confer page 00 As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for outdoor use. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight mm weight 870 G,5 8,0 58,0 5,0 87 G 5,9 90,0 50,0 87 G,5 0,8 95,0 5,0 877 G 35 30,7 3,0 00,0 87 G,5 5,0 30,0 978 G 50 3,5 90,0 950,0 873 G,8 3,0 70,0 0 979 G 70, 0,0 090,0 /0 87 G 0 8,8 38,0 70,0 8 980 G 95 8, 38,0 5580,0 3/0 875 G,8 5,0,0 98 G 0 5, 08,0 700,0 /0 Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 99

TOPFLEX -C-PUR Motor power supply cable for drag chains 0,/kV, EMC preferred type, halogen-free, meter marking Special-PUR drag chain cable Adhesion-free, extremely abrasion adapted to DIN VDE 093, 095, 050, DIN VDE 085-55- / DIN EN 5055- DIN VDE 095 cl., extra fine-wire, BS 30 cl., IEC 08 cl. Core insualtion PP resistant, halogen-free, resistant to hydrolysis and microbial attack resistant to UV-radiation, flexing -30 C to +80 C fixed installation -0 C to +80 C Nominal voltage U0/U 00/000 V Core identification to DIN VDE 093 black cores with continuous white numbering oxygen and ozone Test voltage 000 V GN-YE conductor max. 50 Ohm/km Cores stranded together with optimal lay-length and stabilising filler Fleece wrapping facilitates sliding min. 0 MOhm x km Inner sheath of TPE Min. bending radius Tinned copper braided screen, G = with green-yellow conductor flexing 0x cable Ø 85% coverage fixed installation 5x cable Ø Outer sheath of PUR Sheath colour grey (RAL 700) For extreme applications extending beyond standard solutions we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Please observe applicable installation regulations for use in energy supply chains. unscreened analogue type: TOPFLEX -PUR, confer page 99 As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for outdoor use. To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight mm weight 970 G,5,3 99,0 0,0 97 G 5 3, 9,0 990,0 97 G,5 3,5 9,0 30,0 977 G 35 35, 80,0 535,0 97 G,0 3,0 90,0 98 G 50,5 370,0 330,0 973 G 7,8 3,0 80,0 0 983 G 70 8,8 357,0 50,0 /0 97 G 0, 59,0 035,0 8 98 G 95 5, 00,0 090,0 3/0 975 G 7, 807,0 0,0 985 G 0 58,5 53,0 7380,0 /0 Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 00

TOPSERV 0 / 0 PUR servo cable with or signal pairs 0,/kV, high flexible, cable for drag chain, EMC preferred type D Spezial-PUR drag chain cable low capacitance by using PP as core adapted to DIN VDE 095, 050, DIN VDE 085-55--/DIN EN 5055- DIN VDE 095 cl., extra fine-wire Core insulation of halogen-free PP insulation PUR-outer sheath low adhesion, flexing -30 C to +80 C fixed installation -0 C to +80 C Nominal voltage power supply cores U0/U 00/000 V control cores U0/U 300/500 V Core identification power supply cores core : black with imprint U/L/C/L+ core : black with imprint V/L core 3: black with imprint W/L3/D/Lcontrol cores resistant to hydrolysis and microbial attack, halogen-free These highly flexible cables are fitted with an additional overall screen to assure EMC compatibility, i.e. the protection against electromagnetic interference Test voltage power supply cores 000 V control cores 000 V Power rating to DIN VDE 098 part TOPSERV 0 core black with imprint BR core black with imprint BR TOPSERV 0 pair : black with number no. 5+ pair : black with number no. 7+8 min. 0 MOhm x km GN-YE conductor For extreme applications extending beyond Screening of the control cores in pairs, standard solutions we recommend that flexing 7,5x cable Ø tinned drain wire and you request our questionnaire, which has fixed installation x cable Ø tinned Cu braid been especially designed for energy supply Control cores stranded in pairs and laid up in systems. max. 50 Ohm/km layers together with the power supply cores Foil wrapping Overall screening of tinned cu braid, visible coverage min. 80% Fleece wrapping Outer sheath of PUR Sheath colour petrol (RAL 508) Please observe applicable installation regulations for use in energy supply chains. AWG sizes are approximate equivalent values. The actual cross-section is in. Servo-cable and Feedback-cable with UL-approval to e.g. Siemens, Bosch Rexroth, Lenze etc. can be found in chapter N... The combination of feeder cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors, as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements are met to a high degree as is the electromagnetic compatibillity (EMC). These cables can also be used as drag chain cables. Manufacturing is based on specifications from renowned manufacturers of servo-actuators and servo-controls as well as in accordance with diverse VDE standards. for system SIMODRIVE. To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. TOPSERV 0 ( pair screened and overall screening) TOPSERV 0 ( pairs individually screened and overall Part no. No.cores x Outer Ø Cop. Weight AWG-No. screening) weight Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight 79 ( G,5 + ( x,0)),5 39,0,0 mm ( G,5 + ( x,0)) 3, 88,0 73,0 7990 ( G,5 + x ( x,0)), 8,0,0 7705 (G+( x,0)), 0,0 35,0 799 ( G,5 + x ( x,0)) 5,0 3,0 3,0 770 (G+( x,0)),0 30,0 500,0 0 799 (G+ x ( x,0)),0 308,0 5,0 7707 (G0+( x,0)) 0, 590,0 753,0 8 7993 (G+ x ( x,0)) 8, 0,0 57,0 0 7708 (G+( x,0)) 3,8 85,0 0,0 799 (G0+ x ( x,0)),8 7,0 805,0 8 7709 (G5+( x,0)) 7,0 30,0 99,0 7995 (G+ x ( x,0)) 5,0 98,0,0 770 (G35+( x,0)) 3,9 80,0 99,0 799 (G5+ x ( x,0)) 7,7 00,0 58,0 77 (G50+( x,0)) 3,7 530,0 880,0 70 (G35+ x ( x,0)) 3,0 88,0 85,0 Dimensions and specifications may be changed without prior notice. (RD0) 7997 (G50+ x ( x,0)) 37,0 57,0 977,0 Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 0

Feedback cables PVC EMC-preferred type, meter marking Special core and sheath compound of PVC Bare copper, fine and/or ultra-fine wire Largely oil-resistant, for oil-/ chemical conductors acc. to DIN VDE 095 cl.5 Resistance see Technical Information table flexing -5 C to +70 C fixed installation -30 C to +80 C Nominal voltage 350 V Test voltage core/core 000 V and/or IEC 08 Core insulation of PVC Part No. 800 Cu-screen of single pairs and PVC sheath Core identification see table below Tests core/screen 000 V Single cores or pairs stranded in layer with optimal lay-length PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, min. 0 MOhm x km Core wrapping with film DIN EN 033--, IEC 033- (equivalent 0x cable Ø Tinned copper braided screen, 85% coverage DIN VDE 07 part 80 test method B) Outer sheath of special PVC max. 50 Ohm/km Colour grey (RAL 700) AWG sizes are approximate equivalent values. The actual cross-section is in. These feedback cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission of data and signals. Additional cores for the power supply to individual components are available. To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. TOPFLEX -PVC Part No.cores x no. 800 ( 3 x ( x 0,) + ( x 0,5)) 80 ( x x 0, + x 0,5) 85 ( 0 x 0, + x 0,5) 8 ( 0 x 0, + x 0,5) Core marking 0, GN+YE, GY+PK, BU+RD RD+BK, BN+GN, YE+VT, GN+PK DIN 700 DIN 700 Incremental feedback-cable Part No.cores x Core no. marking 0,5 85 ( x x 0,5 + x,0) BN+GN, RD+BK, VT+BU, GY+PK Dimensions and specifications may be changed without prior notice. (RD0) Core marking 0,5 WH, BN WH, BU, WH/GN, BN/GN WH, BN WH, BN, GN, YE Core marking WH, BN Sheath colour Grey Grey Grey Grey Sheath colour Grey Outer Ø Cop. mm weight 8,5 78,0 8,5 8,0 8,0, 8, 5,3 Outer Ø Cop. mm weight 8,8,0 Weight,0,0 70,0 8,0 Weight 0,0 AWG-No. AWG-No. Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 0

Feedback cables PUR high flexible feedback cables for drag chain, EMC-preferred type, meter marking D flexing -30 C to +80 C fixed installation -0 C to +80 C Nominal voltage TOPFLEX -PUR 350 V Tachofeedback-cable-C-PUR 50 V Incremental Feedback-cable-C-PUR 50 V Test voltage core/core 000 V core/screen 000 V min. 0 MOhm x km flexing 0x cable Ø fixed installation 5x cable Ø max. 50 Ohm/km Radiation resistance up to 00x0 cj/kg (up to 00 Mrad) DIN VDE 095 cl., extra fine-wire, BS 30 cl., IEC 08 cl. Core insualtion of PP Part No. 87 Cu-screen of single pairs or single cores and PETP (polyethylene terephthalate) sheath Core identification see table below Single cores or pairs stranded in layer with optimal lay-length (pairs part no. 88) Drain wire Tinned copper braided screen, 85% coverage Outer sheath of special PUR, matt Sheath colour see table below Special PUR outer sheath low adhesion Resistant to Oils and fats Acids and alkalis Hydraulic fluids Oxygen and ozone UV-radiation Hydrolysis Microbial attack Water and weathering effects The high abrasion resistance and notch resistance meet the highest requirements For extreme applications extending beyond standard solutions we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Please observe the assembly instruction for use in energy supply chains. AWG sizes are approximate equivalent values. The actual cross-section is in. Both cables fulfil different tasks for the control of servo-motors. The tachofeedback-cable or response cable serves the regulation of the motor speed and measurement of the actual values. The incremental feedback-cable or position response cable transfers the control signals for positioning and engineering characteristics and is used as the flexible connecting cable for tachometer, brakes and pulse transmitter in case of high mechanical stress in plant, machine and control engineering in dry, moist and wet rooms. Particularly suitable for continuous operating in drag chains, industrial robotics and handling equipment as these cables enable an excellent transmission of data and signals. Additional cores for the power supply to individual components are available. The braided screen guarantees reliable signal transmission. Optimum functionality, long service life and an excellent cost-performance ratio are given for the mentioned applications by the special compounds used for insulation and sheath. To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. TOPFLEX -PUR Part No.cores x no. 87 ( 3 x ( x 0,) + ( x 0,5)) 85 x x 0, + x 0,5 89 ( 0 x 0, + x 0,5) Tachofeedback-cable Part No.cores x no. 83 ( 9 x 0,5) Core marking 0, DIN 700 BN+GN, YE+VT, GY+PK, RD+BU DIN 700 Core marking 0,5 WH, BN, GN, YE, GY, PK, BU, RD, BK Incremental feedback cable Part No.cores x Core no. marking 0, 88 ( x x 0,5 + x,0) RD+BK, BN+GN, YE+VT, GN+PK Dimensions and specifications may be changed without prior notice. (RD0) Core marking 0,5 WH, BN WH, BN, WH/GN, BN/GN WH, BN Core marking - - Core marking WH, BN Sheath colour Grey Grey Grey Sheath colour Orange Sheath colour Orange Outer Ø Cop. mm weight 8,3 78,0 8, 73,0 7, 39,0 Outer Ø Cop. mm weight 8,8 80,8 Outer Ø Cop. mm weight 8,8 5, Weight 03,0 05,0 83,0 Weight 8,0 Weight 05,0 AWG-No. AWG-No. 0 AWG-No. 03

TOPFLEX -EMV-YSLCY-J for power supply connections to frequency converters, double screened, 0,/kV, meter marking Special motor power supply cable for frequency converters adapted to DIN VDE 050 flexing +5 C to +70 C fixed installation -0 C to +70 C Nominal voltage U0/U 00/000 V Max. operating voltage A.C. and 3-phase 700/00 V DC operation 900/800 V Test voltage 000 V min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation-resistance up to 80x0 cj/kg (up to 80 Mrad) DIN VDE 095 cl.5, fine-wire, BS 30 cl.5, IEC 08 cl.5 Core insulation of polyethylene (PE) Core identification BN, BK, GY GN-YE conductor Cores stranded in concentric layers. Screen with special aluminium film. Tinned copper braided screen, 85% coverage Outer sheath of special PVC Sheath colour transparent G = with GN-YE conductor **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. AWG sizes are approximate equivalent values. The actual cross-section is in. Low mutual capacitance Low coupling resistance for high electromagnetic compatibility This screened motor supply cable with low mutual capacitance of the single cores because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting cables Due to the optimal screening an interference-free operation of frequency converters is obtained Tests PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part This TOPFLEX -EMV-YSLCY-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments, not however for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. 08 085 08 087 088 089 090 09 09 093 09 095 09 097 No.cores x G,5 G,5 G G G 0 G G 5 G 35 G 50 G 70 G 95 G 0 G G 85 Outer Ø mm 0,,9 3, 5,3 9,,,7 9,3 3, 39,0,0 8,7 5, 0, Mutual capacitance Core / Core nf / km 70 80 90 90 0 0 0 90 90 50 Core / Screen nf / km 0 30 00 30 0 0 30 30 0 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 3 0 0 80 90 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 8 3 8 08 35 8 07 50 9 335 38 Cop. weight 95,0,0 35,0 30,0 533,0 789,0 3,0,0 35,0 39,0 3,0 535,0 39,0 739,0 Weight 30,0 300,0 85,0 33,0 83,0 9,0 8,0,0 955,0 3953,0 530,0 0,0 703,0 838,0 AWG-No. 0 8 /0 3/0 /0 300 kcmil 350 kcmil Dimensions and specifications may be changed without prior notice. (RD0) 0

TOPFLEX -EMV-3 PLUS YSLCY-Jfor power supply connections to frequency converters, double screened, 0,/kV, meter marking D Special motor power supply cable for frequency converters adapted to DIN VDE 050 flexing +5 C to +70 C fixed installation -0 C to +70 C Nominal voltage U0/U 00/000 V Max. operating voltage A.C. and 3-phase 700/00 V DC operation 900/800 V Test voltage 000 V min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation-resistance up to 80x0 cj/kg (up to 80 Mrad) DIN VDE 095 cl.5, fine-wire, BS 30 cl.5, IEC 08 cl.5 Core insulation of polyethylene (PE) Core identification BK, BN, GY GN-YE conductor (divided into 3) 3+3-core structure Cores stranded in concentric layers. Screen with special aluminium film. Tinned copper braided screen, 85% coverage Outer sheath of special PVC Sheath colour transparent **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. AWG sizes are approximate equivalent values. The actual cross-section is in. Low mutual capacitance Low coupling resistance for high electromagnetic compatibility The minimum cross-section of 0,75² meets the requirements of DIN EN 00 part. The 3 PLUS-construction of motor power supply cables features a symmetrical 3-core design, improved in terms of EMC characteristics comparing favorably with a -core version. The protective conductor PE, divided into 3 is uniformly stranded in the interstices. This enables an extremely concentric structure. Due to the optimal screening an interference-free operation of frequency converters is obtained Tests PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments not however for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. This screened motor supply cable with low mutual capacitance of the single cores because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting cables. Due to the optimal screening an interference-free operation of frequency converters is obtained. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. 38 39 370 37 37 373 37 375 37 377 378 379 380 38 38 No.cores x 3 x,5 + 3 G 0,5 3 x,5 + 3 G 0,5 3 x + 3 G 0,75 3 x + 3 G,0 3 x 0 + 3 G,5 3 x + 3 G,5 3 x 5 + 3 G,0 3 x 35 + 3 G,0 3 x 50 + 3 G 0,0 3 x 70 + 3 G 0,0 3 x 95 + 3 G,0 3 x 0 + 3 G,0 3 x + 3 G 5,0 3 x 85 + 3 G 35,0 3 x 0 + 3 G,5 Outer Ø mm 9, 0,8,3,0 7,,,5,9 3,5 35,5 0,, 9,3 55, 0,0 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 3 0 0 80 90 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 8 3 8 08 35 8 07 50 9 335 38 53 Cop. weight 8,0,0,0 98,0 9,0 73,0 38,0 535,0 08,0 87,0 3953,0 83,0 5,0 99,0 850,0 Weight AWG-No. 0,0 0,0 33,0 0,0 0 5,0 8 89,0 35,0 78,0 399,0 305,0 /0,0 3/0 507,0 /0 8,0 300 kcmil 789,0 350 kcmil 950,0 500 kcmil Dimensions and specifications may be changed without prior notice. (RD0) 05

TOPFLEX -EMV-UV-YSLCYK-J for power supply connections to frequency converters, double screened, 0,/kV, meter marking Special motor power supply cable for frequency converters adapted to DIN VDE 050 flexing -5 C to +70 C fixed installation -0 C to +70 C Nominal voltage U0/U 00/000 V Max. operating voltage A.C. and 3-phase 700/00 V DC operation 900/800 V Test voltage 000 V min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation-resistance up to 80x0 cj/kg (up to 80 Mrad) DIN VDE 095 cl.5, fine-wire, BS 30 cl.5, IEC 08 cl.5 Core insulation of polyethylene (PE) Core identificdation BN, BK, GY GN-YE conductor Cores stranded in concentric layers. Screen with special aluminium film. Tinned copper braided screen, 85% coverage Outer sheath of special PVC Sheath colour black (RAL 9005) **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. Low mutual capacitance Low coupling resistance for high electromagnetic compatibility UV-resitant Outdoor application, possible for installation in underground at G This screened motor supply cable with low mutual capacitance of the single cores because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting cables Due to the optimal screening an interference-free operation of frequency converters is obtained Tests PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part AWG sizes are approximate equivalent values. The actual cross-section is in. This TOPFLEX -EMV-YSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for outdoor applications, possible for installation in underground at G. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. 3 35 3 37 38 39 0 3 5 7 No.cores x G,5 G,5 G G G 0 G G 5 G 35 G 50 G 70 G 95 G 0 G G 85 Outer Ø mm 0,,9 3, 5,3 9,,,7 9,3 3, 39,0,0 8,7 5, 0, Mutual capacitance Core / Core nf / km 70 80 90 90 0 0 0 90 90 50 Core / Screen nf / km 0 30 00 30 0 0 30 30 0 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 3 0 0 80 90 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 8 3 8 08 35 8 07 50 9 335 38 Cop. weight 95,0,0 35,0 30,0 533,0 789,0 3,0,0 35,0 39,0 3,0 535,0 39,0 739,0 Weight 30,0 300,0 85,0 30,0 80,0 90,0 80,0 0,0 950,0 3950,0 5300,0 00,0 700,0 8380,0 AWG-No. 0 8 /0 3/0 /0 300 kcmil 350 kcmil Dimensions and specifications may be changed without prior notice. (RD0) 0

TOPFLEX -EMV-UV-3 PLUS YSLCYK-J for power supply connections to frequency converters, double screened, 0,/kV, meter marking D Special motor power supply cable for frequency converters adapted to DIN VDE 050 flexing -5 C up to +70 C fixed installation -0 C up to +70 C Nominal voltage U0/U 00/000 V Max. operating voltage A.C. and 3-phase 700/00 V DC operation 900/800 V Test voltage 000 V min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation resistance up to 80x0 cj/kg (up to 80 Mrad) DIN VDE 095 cl.5, fine-wire, BS 30 cl.5, IEC 08 cl.5 Core insulation of polyethylene (PE) Core identification BK, BN, GY GN-YE conductor (divided into 3) 3+3 core design Cores stranded in concentric layers. Screen with special aluminium film. Tinned copper braided screen, 85% coverage Outer sheath of special PVC Sheath colour black (RAL 9005) **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. AWG sizes are approximate equivalent values. The actual cross-section is in. Low mutual capacitance Low coupling resistance for high electromagnetic compatibility Due to the optimal screening an interference-free operation of frequency converters is obtained The 3 PLUS-construction of motor power supply cables features a symmetrical 3-core design, improved in terms of EMC characteristics comparing favorably with a -core version. The protective conductor PE, divided into 3 is uniformly stranded in the interstices. This enables an extremely concentric structure The minimum cross-section of 0,75 meets the requirements of DIN EN 00 part UV-resistant Outdoor application This screened motor supply cable with low mutual capacitance of the single cores because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting cables Tests PVC self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for outdoor applications, possible for installation in underground at 3x+3G,5. Used in the automobile industry, food industry, environmental engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Continuation 07

TOPFLEX -EMV-UV-3 PLUS YSLCYK-J for power supply connections to frequency converters, double screened, 0,/kV, meter marking Part no. 73 7 75 7 77 78 79 80 8 8 83 8 85 8 87 No.cores x 3 x,5 + 3 G 0,5 3 x,5 + 3 G 0,5 3 x + 3 G 0,75 3 x + 3 G,0 3 x 0 + 3 G,5 3 x + 3 G,5 3 x 5 + 3 G,0 3 x 35 + 3 G,0 3 x 50 + 3 G 0,0 3 x 70 + 3 G 0,0 3 x 95 + 3 G,0 3 x 0 + 3 G,0 3 x + 3 G 5,0 3 x 85 + 3 G 35,0 3 x 0 + 3 G,5 Outer Ø mm 9, 0,8,3,0 7,,,5,9 3,5 35,5 0,, 9,3 55, 0,0 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 3 0 0 80 90 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 8 3 8 08 35 8 07 50 9 335 38 53 Cop. weight 8,0,0,0 98,0 9,0 73,0 38,0 535,0 08,0 87,0 3953,0 83,0 5,0 99,0 850,0 Weight AWG-No. 0,0 0,0 33,0 0,0 0 5,0 8 89,0 35,0 78,0 399,0 305,0 /0,0 3/0 5075,0 /0 8,0 300 kcmil 789,0 350 kcmil 950,0 500 kcmil Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 08

TOPFLEX -EMV-UV-XSLCYK-J for power supply connections to frequency converters, double screened, higher current carrying capacity, 0,/kV, meter marking D Special motor power supply cable for frequency converters adapted to DIN VDE 050 DIN VDE 095 cl.5, fine-wire, BS 30 cl.5, IEC 08 cl.5 Core insulation of cross-linked flexing -5 C to +90 C polyethylene (XLPE) fixed installation -0 C to +90 C Core identification BN, BK, GY Permissible operating temperature GN-YE conductor at conductor +90 C Cores stranded in concentric layers Nominal voltage U0/U 00/000 V. Screen with special aluminium film Max. operating voltage. Tinned copper braided screen, A.C. and 3-phase 700/00 V 85% coverage DC operation 900/800 V Outer sheath of special PVC Test voltage 000 V Sheath colour black (RAL 9005) min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation-resistance up to 80x0 cj/kg (up to 80 Mrad) **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. AWG sizes are approximate equivalent values. The actual cross-section is in. Low mutual capacitance Low coupling resistance for high electromagnetic compatibility UV-resitant Outdoor application, possible for installation in underground at G This screened motor supply cable with low mutual capacitance of the single cores because of the special XLPE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PE-sheathed connecting cables Due to the optimal screening an interference-free operation of frequency converters is obtained Tests self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part This TOPFLEX -EMV-UV-XSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power distribution cables. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for outdoor applications, possible for installation in underground at G. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Part no. 89 90 9 9 93 9 No.cores x G,5 G,5 G G G 0 G Outer Ø mm 0,,,8,9 7,7 0,9 Mutual capacitance Core / Core nf / km 70 80 90 90 0 0 Core / Screen nf / km 0 30 00 30 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 0 0 80 90 Power ratings **) with 3 loaded cores in Amperes 3 3 5 75 00 Cop. weight 95,0,0 35,0 30,0 533,0 789,0 Weight 30,0 300,0 85,0 30,0 80,0 90,0 AWG-No. 0 8 Continuation 09

TOPFLEX -EMV-UV-XSLCYK-J for power supply connections to frequency converters, double screened, higher current carrying capacity, 0,/kV, meter marking Part no. 95 9 97 98 99 500 50 507 No.cores x G 5 G 35 G 50 G 70 G 95 G 0 G G 85 Outer Ø mm 5,3 8,0 3,3 37,,,8 5,3 58,7 Mutual capacitance Core / Core nf / km 0 90 90 50 Core / Screen nf / km 0 0 30 30 0 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 3 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 7 58 9 98 3 399 5 Cop. weight 3,0,0 35,0 39,0 3,0 535,0 39,0 739,0 Weight 80,0 0,0 950,0 3950,0 5300,0 00,0 700,0 8380,0 AWG-No. /0 3/0 /0 300 kcmil 350 kcmil Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP 0

TOPFLEX -EMV-UV-3 PLUS XSLCYK-J for power supply connections to frequency converters, double screened, higher current carrying capacity, 0,/kV, meter marking D Special motor power supply cable for frequency converters adapted to DIN VDE 050 flexing -5 C to +90 C fixed installation -0 C to +90 C Permissible operating temperature at conductor +90 C Nominal voltage U0/U 00/000 V Max. operating voltage A.C. and 3-phase 700/00 V DC operation 900/800 V Test voltage 000 V min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation resistance up to 80x0 cj/kg (up to 80 Mrad) DIN VDE 095 cl.5, fine-wire, BS 30 cl.5, IEC 08 cl.5 Core insulation of cross-linked polyethylene (XLPE) Core identification BK, BN, GY GN-YE conductor (divided into 3) 3+3 core design Cores stranded in concentric layers. Screen with special aluminium film. Tinned copper braided screen, 85% coverage Outer sheath of special PVC Sheath colour black (RAL 9005) **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. AWG sizes are approximate equivalent values. The actual cross-section is in. Low mutual capacitance Low coupling resistance for high electromagnetic compatibility Due to the optimal screening an interference-free operation of frequency converters is obtained The 3 PLUS-construction of motor power supply cables features a symmetrical 3-core design, improved in terms of EMC characteristics comparing favorably with a -core version. The protective conductor PE, divided into 3 is uniformly stranded in the interstices. This enables an extremely concentric structure. The minimum cross-section of 0,75 meets the requirements of DIN EN 00 part UV-resistant Outdoor application, possible for installation in undergraound at 3x+3G,5 This screened motor supply cable with low mutual capacitance of the single cores because of the special XLPE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PE-sheathed connecting cables Tests self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for outdoor applications, possible for installation in underground at 3x+3G,5. Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power distribution cables. Used in the automobile industry, food industry, environmental engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Continuation

TOPFLEX -EMV-UV-3 PLUS XSLCYK-J for power supply connections to frequency converters, double screened, higher current carrying capacity, 0,/kV, meter marking Part no. 508 509 50 5 5 53 5 55 5 57 58 59 50 5 587 No.cores x 3 x,5 + 3 G 0,5 3 x,5 + 3 G 0,5 3 x + 3 G 0,75 3 x + 3 G,0 3 x 0 + 3 G,5 3 x + 3 G,5 3 x 5 + 3 G,0 3 x 35 + 3 G,0 3 x 50 + 3 G 0,0 3 x 70 + 3 G 0,0 3 x 95 + 3 G,0 3 x 0 + 3 G,0 3 x + 3 G 5,0 3 x 85 + 3 G 35,0 3 x 0 + 3 G,5 Outer Ø mm 9, 0,8,3,0 7, 0, 3,, 30,8 3, 37,8, 7,5 53, 58,7 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 3 0 0 80 90 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 3 3 5 75 00 7 58 9 98 3 399 5 538 Cop. weight 8,0,0,0 98,0 9,0 73,0 38,0 535,0 08,0 87,0 3953,0 83,0 5,0 99,0 850,0 Weight AWG-No. 0,0 0,0 33,0 0,0 0 5,0 8 89,0 35,0 78,0 399,0 305,0 /0,0 3/0 5075,0 /0 8,0 300 kcmil 789,0 350 kcmil 950,0 350 kcmil Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP

TOPFLEX -EMV-UV-XSLCH-J for power supply connections to frequency converters, halogen-free, double screened, higher current carrying capacity, 0,/kV, meter marking D Special motor power supply cable for frequency converters adapted to DIN VDE 050 Bare copper, fine wire conductor to DIN VDE 095 cl.5, BS 30 cl.5, IEC 08 cl.5 Core insulation of cross-linked flexing -5 C to +90 C polyethylene (XLPE) fixed installation -0 C to +90 C Core cidentification: BN, BL, GY Permissible operating temperature GN-YE conductor at conductor +90 C Cores stranded in concentric layers Nominal voltage U0/U 00/000 V. Screen with special aluminium film Max. operating voltage. Tinned copper braided screen, A.C. and 3-phase 700/00 V 85% coverage DC operation 900/800 V Outer sheath of special polyolefin compound Test voltage 000 V Sheath colour black (RAL 9005) min. 00 MOhm x km acc. to different cross-sections max. 50 Ohm/km free-movement for outer Ø: up to mm: 0x cable Ø > -0 mm: 5x cable Ø > 0 mm: 0x cable Ø fixed installation for outer Ø: up to mm: 5x cable Ø > -0 mm: 7,5x cable Ø > 0 mm: 0x cable Ø Radiation-resistance up to 80x0 cj/kg (up to 80 Mrad) **) The current carrying capacity for permanent operation at ambient temperature of 30 C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 098 part. AWG sizes are approximate equivalent values. The actual cross-section is in. halogen-free Low mutual capacitance Low coupling resistance for high electromagnetic compatibility This screened motor supply cable with low mutual capacitance of the single cores because of the special XLPE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PE-sheathed connecting cables Due to the optimal screening an interference-free operation of frequency converters is obtained Tests self-extinguishing and flame retardant acc. to DIN VDE 08-33--, DIN EN 033--, IEC 033- (equivalent DIN VDE 07 part 80 test method B) Meets EMC requirements acc. to EN 550 and DIN VDE 0875 part This TOPFLEX -EMV-UV-XSLCH-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power distribution cables. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments. These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas. The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional interference requirements of EN 550. = The product is conformed with the EC Low-Voltage Directive 00/95/EC. Continuation 3

TOPFLEX -EMV-UV-XSLCH-J for power supply connections to frequency converters, halogen-free, double screened, higher current carrying capacity, 0,/kV, meter marking Part no. 5 53 5 55 5 57 58 59 530 53 53 533 53 535 No.cores x G,5 G,5 G G G 0 G G 5 G 35 G 50 G 70 G 95 G 0 G G 85 Outer Ø mm 0,,,8,9 7,7 0,9 5,3 8,0 3,3 37,,,8 5,3 58,7 Mutual capacitance Core / Core nf / km 70 80 90 90 0 0 0 90 90 50 Core / Screen nf / km 0 30 00 30 0 0 30 30 0 Coupling resistance at MHz at 30 MHz Ohm/km Ohm/km 8 7 9 3 0 0 80 90 95 85 0 5 50 Power ratings **) with 3 loaded cores in Amperes 3 3 5 75 00 7 8 9 98 3 399 5 Cop. weight 95,0,0 35,0 30,0 533,0 789,0 3,0,0 35,0 39,0 3,0 535,0 39,0 739,0 Weight 30,0 300,0 85,0 30,0 80,0 90,0 80,0 0,0 950,0 3950,0 5300,0 00,0 700,0 8380,0 AWG-No. 0 8 /0 3/0 /0 300 kcmil 350 kcmil Dimensions and specifications may be changed without prior notice. (RD0) Suitable accessories can be found in Chapter X. Cable Gland - HELUTOP HT-MS-EP