INNOZED D0 fuse-bases with touch protection

Similar documents
INNOZED D0 fuse-bases with touch protection

LINOCUR Size D02 63A 230VAC/440VAC

IEC Low Voltage General Purpose Protection

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

NEOZED D0 fuse-links gg 400/440VAC

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIFIX 60 Universal Bus Bar Carriers

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

BETA Switching Switches and Light Indicators

MULTIVERT 1000A Main Incomer, 690VAC

Modulostar CMS10 Modular fuse-holders

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

MULTIVERT 250A Size 1, 690VAC

Modulostar US10 Modular fuse-holders

UltraSafe US22 Modular fuse-holders

Cylindrical fuse-link

SENTRON SIVACON ALPHA

Fuse switch disconnectors

Control Circuit Protection

Gears & Fuse Gears. IEC General Purpose Fuses DIN Fuses Fuse Switch-disconnectors

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

General Purpose IEC Fuses

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

8WH2 Spring-Loaded Terminals

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Fuse switch disconnectors

8WH2 Spring-Loaded Terminals

Cylindrical fuse-link

Surge-Trap Pluggable STPT2 Series - 40kA

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Fuse switch-disconnectors

Miniature Circuit-Breakers (MCBs)

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

BETA Fuses and Fuse Systems

PANEL PANEL MOUNTING COMPONENTS

SCREW-TYPE DISTRIBUTION BLOCKS

Special Purpose Fuses

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Vertical fuse disconnects

Vertical fuse disconnects

Glass fuse 16x5 mm time lag. Number Amp. Number Amp.

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

FUSE BASES NH FUSE BASES 690V 160A 160A

SCREW-TYPE DISTRIBUTION BLOCKS

MS General Information Extended Product Type: MS

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

NB1 Miniature Circuit Breaker

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Fuse switch-disconnectors

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

vertical fuse switch disconnectors

Fuse holders and fuses

3NP1 Fuse Switch Disconnectors up to 630 A

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Miniature Circuit-Breakers (MCBs)

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Jtec 10kA Miniature Circuit Breaker

Solid State Relays, 3-phase

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

NH-Fuse system Low voltage

Vertical fuse disconnects

Varius SUMMARY OF MODELS

Viking 3 - Screw connection Disconnect terminal blocks

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

MS25, MST25, MS20, MST20

Electronic overload relays EF205 and EF370

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Modular contactor for installation into distribution boards

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

In-line Plug-in Design 3NJ6

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Protection Equipment. 5/2 Introduction

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Horizontal fuse disconnects

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

LV HRC fuse switch-disconnectors

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Standardized fuse characteristics

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Series L9 UL489 Miniature Circuit Breakers

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Siemens AG Fuse Systems. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.com/lowvoltage

Miniature Circuit Breaker

Synergy EN product information

Transcription:

INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks, sizes D01 and D02. It is designed for a fast mounting on DIN rail in distribution boards and panels, for residential and industrial applications. INNOZED has an integrated touch protection cover, that prevents from electrocution in builtin status. The use of combtype busbars allows the positioning of the wires to be visually controlled. The use of wiring bus bars in the lower area of the terminal allows an easier insertion of the wires and visual control of the termination points at the same time. INNOZED allows a flexibility in the connection configuration. The fixing clamps consist of two separate compartments, that ensures a secure connection of two different wires. It is possible to use wires with different crosssections from 4mm² to 35mm² or two similar wires up to 16mm² cross section. TECHNICAL DATA OVERVIEW Voltage AC Voltage DC Amper (A) SCCR 400 VAC 250 VDC 63 A 50 ka (AC), 8 ka (DC) Mounting Installation on to DIN rails to EN 60716 Body Material plastic, silicon and halogen free Contact Materials Screws +/ (PZ2), galvanized, chromized (Chrome 3) Product Size Number of Poles D01,D02 1pole, 3pole Single pole and triple pole design Snap on fixing for DINrails 35mm Multi termination of 2 conductors (35mm² + 16mm²) or comb bus bar and cable possible Frame clamp 1.5 35 mm² fine stranded for direct clamping or with wire end sleeve, M = 3.0 4.0 Nm Space saving fuse base High safety during installation, operation and maintenance Extensive touch protection due to integrated cover Double function clamp up to 35mm² Large termination area and good termination conditions for outgoing feeders Installation in 45mm standard cut out Materials used are synthetic, free of silicon and halogen APPLICATIONS Distribution boards for residential use panel boards for industrial use STANDARDS IEC/EN 602693 VDE 06363 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 1

INNOZED D0 fusebases with touch protection PRODUCT RANGE INNOZED D01 16 A, 400 V AC single pole E14 Design Weight kg 1 Package 04724.000000 04724.000000 W1032489 both sides double function clamp 1.535 mm² 0.08 9 1 weight in kg per piece or set including package INNOZED D01 16 A, 400 V AC triple pole E14 Design Weight kg 1 Package 04734.000000 04734.000000 X1032490 both sides double function clamp 1.535 mm² 0.24 3 1 weight in kg per piece or set including package INNOZED D02 63 A, 400 V AC single pole E18 Design Weight kg 1 Package 04725.000000 04725.000000 Y1032491 both sides double function clamp 1.535 mm² 0.08 9 1 weight in kg per piece or set including package INNOZED D02 63 A, 400 V AC triple pole E18 Design Weight kg 1 Package 04735.000000 04735.000000 Z1032492 both sides double function clamp 1.535 mm² 0.24 3 1 weight in kg per piece or set including package TECHNICAL DATA IN ACCORDANCE WITH EN / IEC 60269 INNOZED D01, 16A 1pole INNOZED D01, 16A 3pole INNOZED D02, 63A 1pole INNOZED D02, 63A 3pole Number of poles/phases 1 3 1 3 Rated operational current I e 16 A 16 A 63 A 63 A Max. power dissipation of fuse links P n 2,5W 2,5W 5,5W 5,5W Rated operational voltage U e 400V AC, 250V DC 400V AC, 250V DC 400V AC, 250V DC 400V AC, 250V DC Rated short circuit making capacity with fuse links U e = AC 400 V; I e = 16 A U e = AC 400 V; I e = 63 A U e = DC 250 V; I e = 16 A U e = DC 250 V; I e = 63 A 50 ka 8 ka Rated impulse withstand voltage U imp 6 kv 6 kv 6 kv 6 kv Rated frequency 50 Hz 50 Hz 50 Hz 50 Hz Fire resistance UL 94 UL 94 UL 94 UL 94 Cable terminal connection Standard cable terminal frame clamp 1 535mm² 50 ka 8 ka frame clamp 1 535mm² 50 ka 8 ka frame clamp 1 535mm² 50 ka 8 ka frame clamp 1 535mm² Size D01 D01 D02 D02 Temperature resistance 120 C 120 C 120 C 120 C Track resistance/comperative tracking index CTI 200 CTI 200 CTI 200 CTI 200 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 2

INNOZED D0 fusebases with touch protection DIMENSIONS INNOZED D0 fuse base with touch protection 45 60 68 55 6 27 81 Dimensions in mm ACCESSORIES D0 screw caps 400V AC synthetic Description Weight Package 01714.000200 01715.000200 11714.000220 11715.000220 01715.000000 01711.000200 01770.000200 01714.000200 E212501 D01, E14, 16A, with testing hole 11.8 g 20 01715.000200 P211981 D02, E18, 63A, with testing hole 11.6 g 20 11714.000220 R214536 D01, E14, 16A, with sealing and testing hole 11.6 g 20 11715.000220 S214537 D02, E18, 63A, with sealing and testing hole 11.6 g 20 01715.000000 L206435 D02, E18, 63A, without testing hole 12 g 20 01715.890200 M214026 D02, E18, 63A, with adapter insert for fuse links size D01 12.4 g 20 D0 screw caps 400/440 VAC, 250 V DC porcelain, with removal grips Description Weight Package 01710.000200 H201211 D01, E14, 16A, with testing hole 16.4 g 20 01711.000200 T215044 D02, E18, 63A, with testing hole 18.5 g 20 01770.000200 F1033740 D01, E14, 16A, with testing hole 16.4 g 20 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 3

INNOZED D0 fusebases with touch protection ACCESSORIES D0 cartridge ring adapter inserts D01 E14 Description Weight Package 01705.002000 01705.004000 01705.002000 J216576 2A, pink 0.4 g 50 01705.004000 J219681 4A, brown 0.4 g 50 01705.006000 P206438 6A, green 0.4 g 50 01705.010000 M213014 10A, red 0.4 g 50 01705.006000 01705.010000 D0 cartridge ring adapter inserts D02 E18 Description Application Weight Package 01706.020000 01706.025000 01706.035000 01706.050000 01706.002000 01706.004000 01706.006000 01706.010000 01706.016000 01706.020000 S200668 20A, blue 0.5 g 50 01706.025000 R213524 25A, yellow 0.6 g 50 01706.035000 J216070 35A, black 0.5 g 50 01706.050000 R218630 50A, white 0.7 g 50 01706.002000 K216577 2A, pink For D01 fuse links in D02 fuse bases 0.5 g 50 01706.004000 S222127 4A, brown For D01 fuse links in D02 fuse bases 0.6 g 50 01706.006000 R211983 6A, green For D01 fuse links in D02 fuse bases 0.6 g 50 01706.010000 H216069 10A, red For D01 fuse links in D02 fuse bases 0.6 g 50 01706.016000 Q218629 16A, grey For D01 fuse links in D02 fuse bases 0.5 g 50 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 4

INNOZED D0 fusebases with touch protection ACCESSORIES Wiring bars / Insulated bus bars Design Weight Package 02963.000000 M215107 single pole, 16 mm², peg design, Lshaped 171 g 5 02963.000000 22963.003000 22963.003000 K302873 22963.361000 J1002417 22963.363000 L302874 02901.000000 E302891 02901.350000 K1002418 02903.165000 G302893 02903.350000 R302902 triple pole, 16 mm², peg design, Lshaped single pole, 35 mm², peg design, Lshaped triple pole, 35 mm², peg design, Lshaped for single pole wiring bus bar endcover for triple pole wiring bus bar for triple pole wiring bus bars up to 16 mm² for triple pole wiring bus bars up to 35 mm² 638 g 5 469 g 5 1214 g 5 0.4 g 10 0.5 g 10 1.8 g 10 1.5 g 10 22963.363000 02901.000000 02901.350000 02903.165000 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 5

LINOCUR LINOCUR IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuselink, equiped with significant safety characeristics and sophisticated switching and terminal technology. The power dissipation of Neozed fuselinks leads to internal heating in the Linocur device. Special design measures have been implemented in the development of Linocur in order to prevent the device from overheating and avoid the unwanted, premature operation of the fuselink: generously sized, solid copper strip conductors highly sprung foot contact wide area of heat transfer through contact with the screw cap wide area of contact at the foot contact special contacts which share functions Thanks to this design, Linocur features one of the lowest power dissipation values on the market for D0 fusecombination units devices. FEATURES & BENEFITS Lowest Power Dissipation Remote fuse monitoring (optional) Highly userfriendly and safe changing of the fuse Bayonett design of the screw cap for quick changing of the fuse Easy installation (feeding from above and below) Double clamp connection for in/ output Modern design Modular system: 1 to 3+N poles, available with and without gauge piece APPLICATIONS Low voltage power distribution for: process industries commercial residential. STANDARDS EN/IEC 609473 DIN VDE 43880 DIN VDE 0660 Part 107 DIN VDE 0638 DIN VDE 0636 Part 3 IEC 602693 IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 1

LINOCUR TECHNICAL DATA OVERVIEW 1 pole AC 230V Voltage 2, 3, 4 pole AC 400V marine application AC 440V per pole DC 65V Ampere Range (A) 2... 63 A Breaking capacity 50 ka Protection IP 20 AC 22B AC 400V 63A SCCR DC 22B DC 65V/pole AC 23B AC 400V 50A AC 23B AC 440V 35A Mounting DIN rail acc. EN 60715 Product Size D02 1, 2, 3polar Number of Poles 2polar (1+N) 4polar (3+N) Overvoltage category IV Rated frequency 50... 60 Hz Rated impulse withstand voltage U imp 6 kv Power dissipation 63A: phase=1.8w, neutral=1.4w IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 2

LINOCUR PRODUCT RANGE D0 Linocur D02 230 to 400VAC, 65VDC Rated current In Number of poles/ phases Width Cross section Weight Package 05861.063000 05861.063000 Z1012620 63 A 1 27 mm 35 mm² 0.2133 kg 3 05862.063000 J1012606 63 A 2 54 mm 35 mm² 0.32 kg 2 05863.063000 B1012622 63 A 3 81 mm 35 mm² 0.64 kg 1 05861.063100 H1012628 63 A 1+N 54 mm 35 mm² 0.32 kg 2 05863.063100 E1012602 63 A 3+N 108 mm 35 mm² 0.64 kg 1 D0 Linocur D02 220VDC Rated current In Number of poles/phases Width Cross section Weight Package 05864.063000 L1012608 63 A 4 108 mm 35 mm² 0.64 kg 1 D0 Linocur D02 230VAC to 400VAC, 65VDC, with fuselinks and fixed gauge pieces Rated current In Number of poles/ phases Width Cross section Weight Package 05863.050000 05861.020000 M1012609 20 A 1 27 mm 35 mm² 0.2133 kg 3 05861.025000 A1012621 25 A 1 27 mm 35 mm² 0.2133 kg 3 05862.025000 B1012760 25 A 2 54 mm 35 mm² 0.32 kg 2 05863.025000 G1012627 25 A 3 81 mm 35 mm² 0.64 kg 2 05861.035000 N1012610 35 A 1 27 mm 35 mm² 0.2133 kg 3 05862.035000 D1012624 35 A 2 54 mm 35 mm² 0.32 kg 2 05863.035000 E1012625 35 A 3 81 mm 35 mm² 0.64 kg 1 05861.050000 C1012761 50 A 1 27 mm 35 mm² 0.2133 kg 3 05862.050000 D1012762 50 A 2 54 mm 35 mm² 0.32 kg 2 05863.050000 P1012611 50 A 3 81 mm 35 mm² 0.64 kg 1 D0 Linocur D02 250VAC to 440 VAC (suitable for marine application) Rated current In Number of poles/ phases Width Cross section Weight Package 05861.063040 H1012605 63 A 1 27 mm 35 mm² 0.138 kg 3 05862.063040 S1012614 63 A 2 54 mm 35 mm² 0.32 kg 2 05863.063040 J1012629 63 A 3 81 mm 35 mm² 0.64 kg 1 05863.063140 T1012615 63 A 3+N 108 mm 35 mm² 0.253 kg 1 IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 3

LINOCUR DIMENSIONS Dimensions in mm ACCESSORIES 01713.700000 01715.700000 01714.830000 01715.710000 D0 screw caps 400V AC synthetic 01713.700000 W1016665 01715.700000 K1015206 Locking devices 01714.830000 J214069 Description Design Weight Package Description Design 01715.710000 L1015207 Reduction Spring, for the use of D01 fuselinks in the bayonet screw cap Size D01 Replacement srew cap with sealing hole, without testing hole D02, 63A Special key for locking caps 1 g 10 Replacement srew cap with sealing hole, without testing hole D02, 63A Rated current In Weight 32.9 g 1 Locking cap for D0 Linocur, with industrial locking wrench 63A 12.5 g 10 63 A 6 g 10 Package IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 4

LINOCUR ACCESSORIES Wiring bars / Insulated bus bars Design Weight Package 02963.000000 M215107 single pole, 16 mm², peg design, Lshaped 171 g 5 02963.000000 22963.003000 22963.363000 22963.003000 K302873 22963.363000 L302874 02901.000000 E302891 02903.165000 G302893 02903.350000 R302902 02923.102159 Z302886 02923.162159 A302887 02923.102243 B302888 02923.162243 C302889 02923.109156 D302890 triple pole, 16 mm², peg design, Lshaped triple pole, 35 mm², peg design, Lshaped for single pole wiring bus bar for triple pole wiring bus bars up to 16 mm² for triple pole wiring bus bars up to 35 mm² Eurovario wiring rail fixed length and may not be cut length 159mm, cross section 10mm² Eurovario wiring rail fixed length and may not be cut length 159mm, cross section 16mm² Eurovario wiring rail fixed length and may not be cut length 243mm, cross section 10mm² Eurovario wiring rail fixed length and may not be cut length 243mm, cross section 16mm² special wiring bar to connect Linocur (27mm) with miniature circuit breakers (18mm) length 140mm, cross section 16mm² 638 g 5 1214 g 5 0.4 g 10 1.8 g 10 1.5 g 10 46.5 g 5 67.5 g 5 81.7 g 5 119 g 10 71.1 g 5 02901.000000 02903.165000 05860.100000 05860.200000 05860.300000 Indication facilities 05860.100000 G1015203 05860.200000 H1015204 05860.300000 J1015205 Terminal clamps 02993.100000 V1007924 Design Weight Package Monitoring device for Linocur 2P, 3P, 3P+N Type 1 (switch position), cross section 1,5mm², operating voltage 400V +/10% Monitoring device for Linocur 2P, 3P, 3P+N Type 2 (fuse operation), cross section 1,5mm², operating voltage 400V +/10% Monitoring device for Linocur 2P, 3P, 3P+N Type 3 (switch position and fuse operation), cross section 1,5mm², operating voltage 400V +/10% Design Weight Package Connecting terminal 50mm², insulated, long, cross section 50mm² (if 35mm² rail 2296.363000 is used then infeed terminal required) 0.435 kg 1 0.435 kg 1 0.435 kg 1 37.5 g 10 IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 5