O6D AND O6E COMPRESSOR DATA AND ACCESSORY GUIDE

Similar documents
SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

RCD Air Cooled Condensing Unit (50/60 Hz)

Build your reputation on our reliability.

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

MODEL SCS REMOTE CONDENSER

SERVICE GUIDE 06D/06E/06CC COMPRESSORS.

McQuay Air-Cooled Reciprocating Chiller ALR

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Bosch BOVA Split System Heat Pump

ZR125KC-TFD. Electrical. Alternate Applications

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Bosch BOVA Split System Heat Pump

MODELS JG43, JG63, JG83 JG44, JG64, JG84

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers

Screw Compressors for Commercial Air Conditioning and Refrigeration

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

Application Data CONTENTS. COMPRESSOR PHYSICAL DATA (Table 1) Table 1 Open-Drive Compressors

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

AE R5 February 1997 Reformatted November 2010

CAC SERIES 3 to 5 Ton Split System Condensers

HCH6. Product Specifications

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Tecumseh Semi Hermetic Condensing Units

MT/MTZ 50 Hz R22 R407C R134a R404A / R507

Copeland Scroll TM compressors. for commercial applications

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Q5RD Series Single Packaged Heat Pump, Single Phase

TECHNICAL SPECIFICATIONS

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

1/2 TO 6 HP INDOOR WATER COOLED CONDENSING UNITS

CONDENSING UNITS RAKB- SERIES. Seven Models

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

TECHNICAL SPECIFICATIONS

N2AE - 50 Hz PRODUCT SPECIFICATIONS

Compressor MODEL 05G $3.00

N4A6. Product Specifications

WCA4**4. Product Specifications

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

Refrigerating Engineers & Technicians Association. Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package

CAC SERIES 12-1/2 Thru 20 Ton

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

HEAT PUMPS UPKB- SERIES. Seven Models

TEH-LINE CONDENSING UNITS

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

Low Profile Unit Coolers

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

Installation, Start-Up and Service Instructions

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

PRAC14 PRODUCT SPECIFICATIONS

Código : Motoc"DISCUS"-6DJ3R40M0-TSN200-M22/502--

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

LUI / LUO. Condensing Units

Shandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

LOW PROFILE UNIT COOLER

1/2-6 HP Air-cooled Condensing Units

R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

DESCRIPTION FEATURES

1/2-6 HP Air-cooled Condensing Units

10+ SEER - AIR CONDITIONER

SANYO SCROLL COMPRESSORS

MV Product Specifications

Código : Motoc"DISCUS"-4DL3F63K0-TSK200-B22/502--

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

CSA6. Product Specifications. SoftSound SXC 2600

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]

H-MSTB January Replaces H-MSTB, Oct M Series. AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor Models. Technical Guide MOH MOZ MOS

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

CARLYLE REMANUFACTURED COPELAND COMPRESSORS

Transcription:

O6D AND O6E COMPRESSOR DATA AND ACCESSORY GUIDE REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION

TABLE OF CONTENTS CARLYLE SEMI-HERMETIC COMPRESSORS GUIDE TO 06D PART NUMBERING SYSTEM... 3 06D AIR CONDITIONING DUTY COMPRESSOR APPLICATION DATA... 4-7 REQUIRED CIRCUIT BREAKERS FOR 06D AC DUTY COMPRESSORS... 8 GUIDE TO 06E PART NUMBERING SYSTEM... 9 06 E AIR CONDITIONING DUTY COMPRESSOR APPLICATION DATA... 10-1 REQUIRED CIRCUIT BREAKERS FOR 06E COMPRESSORS...13 CARLYLE REFRIGERATION COMPRESSORS 06D REFRIGERATION AND MEDIUM TEMPERATURE DUTY COMPRESSOR APPLICATION DATA... 14-16 REQUIRED CIRCUIT BREAKERS FOR 06D REFRIGERATION DUTY COMPRESSORS... 17 06E REFRIGERATION AND MEDIUM TEMPERATURE DUTY COMPRESSOR APPLICATION DATA... 18, 19 REQUIRED CIRCUIT BREAKERS FOR 06E REFRIGERATION DUTY COMPRESSORS... 0 TOTALINE COMPRESSOR OILS - FOR CARLYLE AND TOTALINE COMPRESSORS... 1 MINERAL REFRIGERATION OILS... VACUUM PUMP OILS... POLYOL-ESTER OILS... ALKYLBENZENE REFRIGERATION OILS... OPTIONAL SEMI-HERMETIC O6D & 06E COMPRESSOR ACCESSORIES SUCTION CUTOFF UNLOADING VS. HOT GAS BYPASS UNLOADING COMPARISON... 3 06D AND 06E SUCTION CUTOFF UNLOADING KITS... 4, 5 CRANKCASE HEATERS... 6 TERMINAL BOX KITS... 7 LUBE OIL CONTROLS... 8 SUSPENSION KIT... 8 COMPRESSOR MOUNTING PLATE KIT... 8 CYLINDER HEAD COOLING FAN PACKAGE... 9 TERMINAL LUG PACKAGE... 9 TERMINAL LUGS... 9 ACROSS-THE-LINE JUMPER BAR KIT... 9 REQUIRED SEMI-HERMETIC O6D & 06E COMPRESSOR ACCESSORIES... 30 REQUIRED REFRIGERATION DUTY O6D & 06E COMPRESSOR ACCESSORIES... 31 SERVICE VALVE KITS... 31 COMPRESSOR CROSS REFERENCE DATA... 3-39

CARLYLE SEMI-HERMETIC COMPRESSORS GUIDE TO 06D PART NUMBERING SYSTEM MODEL VARIABLE DIGIT 0 1 PRODUCT SERIES 6 D 3 UNLOADER VARIATIONS A 4 MOTOR SIZE 3 5 CFM DISPLACEMENT 1 6 6 7 KEY NUMBER 0 8 VARIABLES SUCTION VALVE & M.E. COVER ORIENTATION 0 9 OVERLOADS & INTERNAL THERMOSTAT A 10 ELECTRICAL CHARACTERISTIC VARIATIONS 3 11 1 FUTURE DESIGN VARIABLES 0 13 PACKAGING VARIATIONS 0 14 NOTES: 1. SPECIAL ORDER SERVICE COMPRESSORS FOR BRYANT MAY BE PROCESSED AS 9 NAMEPLATED 6 (8TH DIGIT).. SERVICE MODELS WITH C IN THE 10TH DIGIT REPLACE ALL A, C AND E ORIGINAL EQUIPMENT MODELS AND D SERVICE MODELS REPLACE 8 & F MODELS. TERMINAL BOXES AND OVERLOADS ARE TO BE RE-USED OR REPLACED IF DAMAGED. 3. 09 IN THE 11TH & 1TH DIGITS HAS BEEN USED IN THE PAST FOR 400-3-50 MOTORS AND IS NO LONGER USED, SO AS TO AVOID CONFUSION IN SERVICE THESE DIGITS ARE TO BE LEFT ON THIS CHART BUT ARE NOT TO BE RE-USED. L E T T E R A B C D E F G M N R W X Y S H J 1st, nd, 3rd DIGITS SIGNIFY 06D HERMETIC RECIP. COMPRESSOR S T A N D A R D X X X X X X X X X S E R V I C E X X X X 4th DIGIT UNLOADER VARIABLE B O T H 5th DIGIT VARIABLE 0 1 3 4 5 6 7 8 9 DESCRIPTION NO HOT GAS BY-PASS UNLOADERS ELECTRIC UNLOADERS 1 STEP STEP PRESSURE UNLOADERS 1 STEP STEP SUCTION CUT-OFF 1 STEP ELECTRIC UNLOADERS STEP X MEDIUM TEMPERATURE, REPLACES ALL A s IN SERVICE X SHAVED HEADS - SPECIAL ORDER X REFRIGERATION AIC - PLUGGED HEADS, REPLACES ALL C & E SERVICE - SPECIAL ORDER 1 PLUGGED HEAD REPLACES ALL B, C, D & E PROD. MODELS IN SERVICE REFR. PLUGGED HEADS SERVICE - SPECIAL ORDER HI-EFF SERVICE MOD. w/1 BLOCKED UNLOADER HEAD - REPLACES F, G, H & J SUCTION CUT-OFF 1 STEP PRESSURE UNLOADERS STEP MOTOR SIZES CYL 4 CYL 3 HP 6 CYL HP 5 HP 4 LBFT 5 HP 7 LBFT 3-1/ HP 5-1/ HP 3 HP 5 HP 0 LBFT 0 LBFT 4 LBFT 10th DIGIT A B C D E F G T 13th DIGIT 0 1 3 4 5 6 7 FUTURE DESIGN VARIABLES ORIGINAL DESIGN A/C & REFRIG. nd GENERATION REFRIG. COMPRESSOR w/new VALVE PLATE MED. RANGE A/C COMPRESSOR w/refrig. CHARACTERISTICS LOW CLEARANCE VOLUME SUCTION CUT-OFF 1 STEP ELECTRIC UNLOADERS OILLESS OVERLOAD & T STAT VARIABLE SEE NOTE EXTL. OVLDS. YES YES NO NO YES YES YES NO INTL. T RAT. YES NO YES NO YES NO YES YES DESCRIPTION 1st OVERLOAD VARIATION 1st OVERLOAD VARIATION MANUAL RESET OVERLOADS TECUMSEH SERVICE MODELS 14th DIGIT 0 1 3 4 5 6 7 8 9 11th &1th DIGITS 0 0 0 1 0 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 1 1 1 1 3 1 4 1 5 1 8 1 9 1 6 3 1 3 3 6 3 8 3 9 3 3 3 4 PACKAGE VARIATIONS SERVICE UNIT SINGLE PACK- BASE UNIT UNPACKAGES SERVICE PACK- DOMESTIC LESS SERVICE VALVE MULTI-PACK - DOMESTIC EXPORT - 1 UNIT MULTI-PACK PALLETIZED GOVERNMENT PACK SERVICE PACK- DOMESTIC w/service VALVE MATCHED COMPONENTS - CONSISTS OF SEPARATE EXPORT PACKAGE PIECES DOMESTIC MULTI-PACK & MCMINNVILLE ELECTRICAL CHARACTERISTICS VOLTS-PHASE-HERTZ 575-3-60 00-1-60 30-1-60 00-3-60 30-3-60 400/460-3-50/60 30-1-50 0-3-50 SEE NOTE 3 30--60 480-3-60 08/30-3-60 380-3-60 00-3-60 30-3-60 0-3-50 30/460-3-60 575-3-60 400/460-3-50/60 575-3-60 08/30-3-60 400/460-3-50/60 415-3-50 415-3-50 08/30-1-60 0-3-50 START P/W P/W P/W P/W 6th & 7th DIGIT CFM 0 7 0 8 0 9 1 3 1 6 1 8 0 4 8 3 7 CRANKCASE ASSEMBLY NO. 6D0-49 6D3-49 6D3-49 6D48-49 6D48-49 6D48-49 6D48-49 6D68-49 6D75-49 6D75-49 CYL BORE 1-13/16 8th DIGIT KEY NUMBER VARIABLE SIGNIFICANCE 0 PROD. MOD. w/t-box 1 PKG. CPRSR. & CONTROL BOX OEM A/C COMPRESSOR 3 TYLER MODELS 4 TECUMSEH OEM MODELS 5 FUTURE USE 6 REMANUFACTURED SERVICE COMP. 7 NEWMAN SERVICE COMPRESSOR 8 SPECIAL ORDER ONLY 9 SERV. SPEC. OR SEE NOTE 1 9th DIGIT A B C D E F G LOC. OF VALUES MOTOR END MOTOR END MOTOR END MOTOR END MOTOR END PUMP END PUMP END SUCTION SERVICE VALVE VARIABLES M.E. COV. DESC. BOLT 4 BOLT BOLT 4 BOLT BOLT PLAIN PLAIN VALVE ORIENTATION 30 30 0 90 90 or 180 70 90 150 70 5 180 Generally, for a compressor changeout in a Carrier/BDP unit the use of existing circuit breaker(s) is acceptable. 3

CARLYLE SEMI-HERMETIC COMPRESSORS 06D CARLYLE SEMI-HERMETIC COMPRESSORS AIR CONDITIONING DUTY COMPRESSOR APPLICATION DATA For mounting configuration, dimensions and weights, refer to outline drawings in the Totaline Network Parts Catalog. R- CAPACITY (000 BTUH) AIR COOLED WATER COOLED NO. CFM SUCTION 45 SST 40 SST NOMINAL OF @ TEMP. RANGE 130 SCT 105 SCT MODEL NO. HP CYL. 1750 RPM ( F) 0 SC 0 SC 06DM808 3 8.0-10 to 50 36.7 39.8 06D( )313 5 4 13.1-10 to 50 56.9 6.7 06D( )818 6.5 4 18.3-10 to 50 83.3 91.0 06D( )74 6.5 6 3.9-10 to 50-1.6 06D( )84 7.5 6 3.9-10 to 50 106.5 117.3 06D( )38 10 6 8.0-10 to 50 18.7 140.0 06D( )337 10 6 37.1-10 to 50-185.6 06D( )537 15 6 37.1-10 to 50 175.4 191.3 4

CARLYLE SEMI-HERMETIC COMPRESSORS 06D CARLYLE SEMI-HERMETIC COMPRESSORS DATA AND ACCESSORY LISTING To use this chart, first select the compressor suitable for the application. Consider capacity, refrigerant, voltage, wire size, space limitations, etc. Next, use the compressor model number to enter the accessory tables and find the necessary accessories. These include Circuit Breakers, Service Valve Kits, Terminal Box Kits, Crankcase Heaters. You can also select any optional accessories needed for the installation. 06D COMPRESSOR DATA STANDARD EFFICIENCY MODELS WITH ONE PLUGGED HOT GAS BYPASS UNLOADER HEAD OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA 4 CYLINDER... AIR CONDITIONING... UNLOADING... 60 HZ 06DX8186-0600 460 6.5 18.3 7 10800 17.6.0 6.0 06DX8186-100 08/30 6.5 18.3 7 10800 39.0 48.8 137.0 4 CYLINDER... AIR CONDITIONING... UNLOADING... 50 HZ 06DX8186-0600 400 6.5 15 7 9000 17.6.0 6.0 6 CYLINDER... AIR CONDITIONING... UNLOADING... 60 HZ 06DX746-0100 575 6.5 3.9 10 10800 14.1 17.6 50.0 06DX746-0600 460 6.5 3.9 10 10800 17.6.0 6.0 06DX746-100 08/30 6.5 3.9 10 10800 39.0 48.8 137.0 06DX846-0100 575 7.5 3.9 10 14100 17.8. 6.0 06DX846-0600 460 7.5 3.9 10 14100. 7.8 77.0 06DX846-100 08/30 7.5 3.9 10 14100 49.3 61.5 170.0 06DX386-0100 575 10 8 10 15900 0.0 5.0 69.0 06DX386-0600 460 10 8 10 15900 4.8 31.0 86.0 06DX386-100 08/30 10 8 10 15900 55. 69.0 191.0 06DX3376-0100 575 10 37.1 10 15900 0.0 5.0 69.0 06DX3376-0600 460 10 37.1 10 15900 4.8 31.0 86.0 06DX3376-100 08/30 10 37.1 10 15900 55. 69.0 191.0 6 CYLINDER... AIR CONDITIONING... UNLOADING... 50 HZ 06DX746-0600 400 6.5 0 10 9000 17.6.0 6.0 06DX846-0600 400 7.5 0 10 11700. 7.8 77.0 06DX386-0600 400 10 3.3 10 1300 4.8 31.0 86.0 06DX3376-0600 400 10 31 10 1300 4.8 31.0 86.0 06DX5376-0600 400 15 31 10 1700 3.0 40.0 10.0 6 CYLINDER... AIR CONDITIONING... UNLOADING... PART WIND START... 60 HZ 06DX3376-1400 00 10 37.1 10 15900 7.6/7.6 34.5/34.5 115/9 06DX3376-1500 30 10 37.1 10 15900 4.8/4.8 31.0/31.0 103/86 6 CYLINDER... AIR CONDITIONING... UNLOADING... 60 HZ 06DX5376-0100 575 15 37.1 10 0700 5.6 3.0 96.0 06DX5376-0600 460 15 37.1 10 0700 3.0 40.0 10.0 06DX5376-100 08/30 15 37.1 10 0700 71. 89.0 66.0 6 CYLINDER... AIR CONDITIONING... UNLOADING... PART WIND START... 60 HZ 06DX5376-1400 00 15 37.1 10 0700 35.6/35.6 44.5/44.5 160/133 06DX5376-1500 30 15 37.1 10 0700 3.0/3.0 40.0/40.0 144/10 6 CYLINDER... AIR CONDITIONING... UNLOADING... PART WIND START... 50 HZ 06DX386-1800 0 10 3.3 10 1300 41.6 5.0 143 06DX3376-1800 0 10 31 10 1300 41.6 5.0 143 06DX5376-1800 0 15 31 10 1700 46.9 67.0 00 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. Generally, for a compressor changeout in a Carrier/BDP unit, the use of existing circuit breaker(s) is acceptable. 5

CARLYLE SEMI-HERMETIC COMPRESSORS 06D COMPRESSOR DATA - SINGLE PHASE STANDARD EFFICIENCY (NO UNLOADING) OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 60 HZ 06DM8086-0300 30 3 8 3.5 800 17.0.0 70.0 06DM1096-0300 30 8.7 3.5 800 1.5 15.6 50.0 4 CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 60 HZ 06DM3136-0300 30 5 13.1 5 6600 8.0 35.0 100.0 06DM3166-0300 30 5 15.9 5 6600 8.0 35.0 100.0 06DM3186-0300 30 5 18.3 7 6600 8.0 35.0 100.0 06DM5186-0300 30 5.5 18.3 7 7700 36.8 46.0 148.0 06DM7186-0300 30 5 18.3 7 6600 8.0 35.0 100.0 06D COMPRESSOR DATA - THREE PHASE MEDIUM TEMPERATURE (NO UNLOADING) OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 60 HZ 06DM8086-3100 575 3 8 3.5 4100 5.6 7.0 8.4 06DM8086-300 08/30 3 8 3.5 4100 14.0 17.4 71.0 06DM8086-3600 460 3 8 3.5 4100 7.0 8.7 35.5 CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 50 HZ 06DM8086-3600 400 3 6.7 3.5 3400 7.0 8.7 35.5 4 CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 60 HZ 06DM3136-3100 575 5 13.1 5 650 8.6 10.8 40.0 06DM3136-300 08/30 5 13.1 5 650 1.5 7.0 100.0 06DM3136-3600 460 5 13.1 5 650 10.8 13.5 50.0 06DM3166-3100 575 5 15.9 5 650 8.6 10.8 40.0 06DM3166-300 08/30 5 15.9 5 650 1.5 7.0 100.0 06DM3166-3600 460 5 15.9 5 650 10.8 13.5 50.0 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. 06D COMPRESSOR DATA - THREE PHASE HIGH EFFICIENCY (NO UNLOADING) OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA 4 CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 50 HZ 06DM3136-3600 400 5 11 5 500 10.8 13.5 50.0 06DM3166-3600 400 5 13 5 500 10.8 13.5 50.0 6 CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 60 HZ 06DM3376-3100 575 10 37.1 10 16500 17.9 5.0 91.0 06DM3376-3600 460 10 37.1 10 16500.1 31.0 114.0 06DM3376-300 08/30 10 37.1 10 16500 44.3 6.0 8.0 6 CYLINDER... AIR CONDITIONING & MEDIUM TEMP... 50 HZ 06DM3376-3600 400 10 31 10 13700.1 31.0 114.0 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. 6

CARLYLE SEMI-HERMETIC COMPRESSORS 06D COMPRESSOR DATA - THREE PHASE HIGH EFFICIENCY A/C DUTY - SUCTION CUTOFF UNLOADING OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA 4 CYLINDER... AIR CONDITIONING... UNLOADING... 60 HZ 06DS3136-3100 575 5 13.1 5 650 8.6 10.8 40.0 06DS3136-3600 460 5 13.1 5 650 10.8 13.5 50.0 06DS3136-300 08/30 5 13.1 5 650 1.5 7.0 100.0 06DS8166-3600 460 6.5 15.9 5 10800 15.7.0 80.0 06DS8186-3100 575 6.5 18.3 7 10800 1.6 17.6 64.0 06DS8186-3600 460 6.5 18.3 7 10800 15.7.0 80.0 06DS8186-300 08/30 6.5 18.3 7 10800 31.5 44.0 160.0 4 CYLINDER AIR CONDITIONING... UNLOADING... 50 HZ 06DS3136-3600 400 5 11 5 500 10.8 13.5 50.0 06DS8166-3600 400 6.5 13 5 9000 15.7.0 80.0 06DS8186-3600 400 6.5 15 7 9000 15.7.0 80.0 6 CYLINDER... AIR CONDITIONING... UNLOADING... 60 HZ 06DS846-3100 575 7.5 3.9 10 1800 15.9.0 79.0 06DS846-3600 460 7.5 3.9 10 1800 19.9 7.8 99.0 06DS846-300 08/30 7.5 3.9 10 1800 39.7 55.5 198.0 06DS386-3100 575 10 8 10 16500 17.9 5.0 91.0 06DS386-3600 460 10 8 10 16500.1 31.0 114.0 06DS386-300 08/30 10 8 10 16500 44.3 6.0 8.0 06DS5376-0100 575 15 37.1 10 0700 5.6 3.0 96.0 06DS5376-0600 460 15 37.1 10 0700 3.0 40.0 10.0 06DS5376-100 08/30 15 37.1 10 0700 71. 89.0 66.0 6 CYLINDER... AIR CONDITIONING... UNLOADING... 50 HZ 06DS846-3600 400 7.5 0 10 10700 19.9 7.8 99.0 06DS386-3600 400 10 3 10 13700.1 31.0 114.0 06DS5376-0600 400 15 37.1 10 1700 3.0 40.0 10.0 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. Generally, for a compressor changeout in a Carrier/BDP unit, the use of existing circuit breaker(s) is acceptable. 7

CARLYLE SEMI-HERMETIC COMPRESSORS REQUIRED CIRCUIT BREAKERS: 06D... 60Hz (AC DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS 06DM8086-0300 HH83XB480 06DM3376-300 HH83XB305 06DS5376-100 HH83XB311 06DM1096-0300 HH83XB481 06DM3376-1400 HH83XE630 06DX8186-0100 HH83XB450 06DM8096-0300 HH3XB480 06DM3376-1500 HH83XE604 06DX8186-0600 HH83XB445 06DM3136-0300 HH83XB483 06DM5376-0100 HH83XB440 06DX8186-100 HH83XB306 06DM3166-0300 HH83XB483 06DM5376-0600 HH83XB4 06DX7i6-0100 HH83XB450 06DM3186-0300 HH83XB483 06DM5376-100 HH83XB311 06DX746-0600 HH83XB419 06DM5186-0300 HH83XB484 06DM5376-1400 HH83XE633 06DX746-100 HH83XB49 06DM7186-0300 HH83XB483 06DM5376-1500 HH83XE643 06DX846-0100 HH83XB419 06DM8086-300 HH83XB490 06DS3136-3100 HH83XB497 06DX846-0600 HH83XB400 06DM8086-3600 HH83XB494 06DS3136-300 HH83XB316 06DX846-100 HH83XB307 06DM3136-3100 HH83XB497 06DS3136-3600 HH83XB443 06DX386-0100 HH83XB451 06DM3136-300 HH83XB316 06DS8166-3600 HH83XB416 06DX386-0600 HH83XB45 06DM3136-3600 HH83XB443 06DS8186-3100 HH83XB450 06DX386-100 HH83XB305 06DM3166-3100 HH83XB497 06DS8186-300 HH83XB368 06DX3376-0100 HH83XB451 06DM3166-300 HH83XB316 06DS8186-3600 HH83XB416 06DX3376-0600 HH83XB45 06DM3166-3600 HH83XB443 06DS846-3100 HH83XB416 06DX3376-100 HH83XB305 06DM8186-0100 HH83XB450 06DS846-300 HH83XB364 06DX3376-1400 HH83XE630 06DM8186-0600 HH83XB419 06DS846-3600 HH83XB415 06DX3376-1500 HH83XE604 06DM8186-100 HH83XB306 06DS386-3100 HH83XB451 06DX5376-0100 HH83XB40 06DM846-0100 HH83XB419 06DS386-300 HH83XB305 06DX5376-0600 HH83XB401 06DM846-0600 HH83XB400 06DS386-3600 HH83XB45 06DX5376-100 HH83XB311 06DM846-100 HH83XB43 06DS5376-0100 HH83XB40 06DX5376-1400 HH83XE633 06DM3376-3100 HH83XB451 06DS5376-0600 HH83XB401 06DX5376-1500 HH83XE643 06DM3376-3600 HH83XB45 REQUIRED CIRCUIT BREAKERS: 06D... 50Hz (AC DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS 06DM808-3600 HH83XB494 06DS8166-3600 HH83XB416 06DX84-0600 HH83XB400 06DM313-3600 HH83XB443 06DS8186-3600 HH83XB416 06DX38-0600 HH83XB45 06DM316-3600 HH83XB443 06DS846-3600 HH83XB415 06DX38-1800 HH83XB365 06DM818-0600 HH83XB419 06DS386-3600 HH83XB45 06DX337-0600 HH83XB45 06DM84-0600 HH83XB400 06DS5376-3600 HH83XB401 06DX337-1800 HH83XB365 06DM337-3600 HH83XB45 06DX818-0600 HH83XB445 06DX537-0600 HH83XB401 06DM537-0600 HH83XB4 06DX74-0600 HH83XB419 06DX537-1800 HH83XB314 06DS3136-3600 HH83XB443 8

CARLYLE SEMI-HERMETIC COMPRESSORS GUIDE TO 06E PART NUMBERING SYSTEM PRODUCT SERIES DESIGN VARIATIONS USAGE CFM DISPLACEMENT ELECTRICAL CHARACTERISTICS FUTURE DESIGN MODEL AND PACKAGING MODEL VARIABLE DIGIT 0 1 6 E 3 A 4 1 5 5 6 0 7 3 8 4 9 0 10 1st, nd, 3rd DIGITS SIGNIFY 06E HERMETIC COMPRESSOR 4th DIGIT SUCTION CUT-OFF UNLOADING 0 1 3 4 5 6 7 8 9 NO. CYL. 4 6 3 4 5 6 7 8 9 L E T T E R S T A N D A R D A X B X C X D X E X J X K X L X N X P X U X V X W X M X R X T X X Y V I C E 5th DIGIT USAGE LIGHT DUTY COMPRESSOR OR COMPRESSOR TONNAGE MEDIUM DUTY COMPRESSOR HEAVY DUTY COMPRESSOR OILLESS OILLESS OILLESS ER - EM ONLY = 1 UNLOADER SPECIAL ORDER STD. PROD. 50 CFM 75 CFM 4th DIGIT UNLOADER VARIABLE S R E E V R D. H E DESCRIPTION A D X X NO UNLOADERS ONE UNLOADER - ELECTRIC TWO UNLOADERS - ELECTRIC ONE UNLOADER - PRESSURE TWO UNLOADERS - PRESSURE X ONE UNLOADER - ELECTRIC X TWO UNLOADERS - ELECTRIC X ONE UNLOADER - PRESSURE X TWO UNLOADERS - PRESSURE ONE UNLOADER - ELECTRIC TWO UNLOADERS - ELECTRIC ONE UNLOADER - PRESSURE TWO UNLOADERS - PRESSURE MEDIUM TEMP. - NO UNLOADERS REFRIGERATION - NO UNLOADERS SERVICE COMPRESSOR REPLACES w/(1) BLOCKED SUCTION, 3, 4, 5, 6, CUT-OFF UNLOADER HEAD 7, 8, & 9 SERVICE COMPRESSOR REPLACES A, B, C, AIR CONDITION D, E, F, J, K, L & N SERVICE COMPRESSOR REPLACES R REFRIGERATION 6th & 7th DIGIT COMPRESSOR SIZE LONG STROKE STD. CLEARANCE 66 CFM 99 CFM LONG STROKE HI CLEARANCE 60 CFM - COMPRESSOR UNITS (CAC USAGE) NO. CYL. 4 6 STD. PROD. COMPRESSOR (NOM TONS) 33 (NOM TONS) LONG STROKE COMPRESSOR - 44 (NOM TONS) SHORT STROKE - 65 CFM 1 3 4 5 6 7 8 9 0 A 8th DIGIT ELECT 575-3-60 00-1-60 08/30/460-3-60 00-3-60 30-3-60 400-3-50 460-3-60 30-1-50 30-3-50 0/380-3-60 08/30--60 415-3-50 1 3 4 5 6 7 0 1 3 4 5 6 7 8 9 0 1 3 4 5 7 9 10th DIGIT PACKAGING MODEL NO. SINGLE PACK LESS VALVE MULTI-PACK - DOMESTIC SINGLE PACK w/valve MULTI-PACK EXP PALLETIZED LESS VALVE PALLETIZED w/valve MULTI PACK MC MINN 9th DIGIT SERVICE DESIGN VARIABLE THERMOTECTOR PROTECTION OLD STYLE CRANKCASE NEW MANUFACTURE SERVICE COMPRESSOR FUTURE USE REMANUFACTURED SERVICE COMPRESSOR LOW TEMP. OLD STYLE CRANKCASE ROBERTSHAW SENSORS & TAPPED CYL. HEADS. MOTOR PROTECTION KIT REQUIRED FOR THERMOTECTOR APPLICATION REMANUFACTURED SERVICE COMPRESSOR REMANUFACTURED SERVICE COMPRESSOR MEDIUM TEMP. 9th DIGIT PROD. DESIGN VARIABLE OEM MODEL ELECTRICAL REDESIGN FIRST REDESIGN LONG STROKE CRANKCASE SECOND DESIGN ROBERTSHAW MOTOR PROTECTION COMPRESSOR MODEL LESS MOTOR PROTECTION MEDIUM TEMP. ROBERTSHAW MOTOR PROTECTION CEMAK MODEL SYMBOLS: = SAMPLE PART NO. 06E150360 NOTES: 4. 0-3-60 UNIT DESIGNED FOR USE ON 198 to 4 V 4. 380-3-60 UNIT DESIGNED FOR USE ON 34 to 418 V 4. 575-3-60 UNIT DESIGNED FOR USE ON 518 to 660 V 4. 460-3-60 UNIT DESIGNED FOR USE ON 414 to 59 V 4. 30-3-60 UNIT DESIGNED FOR USE ON 198 to 64 V 4. 30-3-50 UNIT DESIGNED FOR USE ON 198 to 64 V 4. 400-3-50 UNIT DESIGNED FOR USE ON 34 to 457 V 4. 00-3-60 UNIT DESIGNED FOR USE ON 180 to 9 V 5. RVS HD CPRSR - ORIGINAL DESIGN NO. 4TH DIGIT A, B, C, D, CRF 9TH DIGIT REDESIGN NO. 4TH DIGIT F, J, K, OR N 9TH DIGIT SAME AS STANDARD 9

CARLYLE SEMI-HERMETIC COMPRESSORS 06E CARLYLE SEMI-HERMETIC COMPRESSORS AIR CONDITIONING DUTY COMPRESSOR APPLICATION DATA For mounting configuration, dimensions and weights, refer to outline drawings in the Totaline Network Parts Catalog. R- CAPACITY (000 BTUH) AIR COOLED WATER COOLED NO. CFM SUCTION 45 SST 40 SST NOMINAL OF @ TEMP. RANGE 130 SCT 105 SCT MODEL NO. HP CYL. 1750 RPM ( F) 0 SC 0 SC 06E( )150 15 4 50.0-10 to 50-45.8 06E( )50 0 4 50.0-10 to 50 3.3 47.0 06E( )65 5 6 65.0-10 to 50 300.3 334.7 06E( )66 5 4 66.0-10 to 50 90.0 30.6 06E( )175 5 6 75.0-10 to 50-364.3 06E( )75 30 6 75.0-10 to 50 33.8 363.0 06E( )199 35 6 99.0-10 to 50-469.7 06E( )99 40 6 99.0-10 to 50 437.9 476.3 CFM = Cubic Feet Per Minute SST = Saturated Suction Temperature SCT = Saturated Condensing Temperature SC = Sub Cooling 10

CARLYLE SEMI-HERMETIC COMPRESSORS 06E COMPRESSOR DATA - THREE PHASE STANDARD EFFICIENCY MODELS WITH ONE HOT PLUGGED GAS BYPASS UNLOADER HEAD OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA 4 CYLINDER... AIR CONDITIONING... 60HZ 06EX150-160 575 15 50 14 000 31 38 98 06EX150-360 08-30/460 15 50 14 000 7/36 90/45 83/14 06EX150-660** 460 15 50 14 000 36 45 14 06EX50-160 575 0 50 14 5300 36 45 10 06EX50-360 08-30/460 0 50 14 5300 87/44 108/54 345/173 06EX50-660** 460 0 50 14 5300 45 56 150 06EX66-160 575 5 66 14 33600 46 57 164 06EX66-360 08-30/460 5 66 14 33600 11/56 140/70 446/3 06EX66-660** 460 5 66 14 33600 57 71 05 4 CYLINDER... AIR CONDITIONING... 50 HZ 06EX150-360 00/400 15 41.7 14 18300 7/36 90/45 83/14 06EX150-660** 400 15 41.7 14 18300 36 45 14 06EX50-360 00/400 0 41.7 14 1100 87/44 108/54 345/173 06EX50-660** 400 0 41.7 14 1100 45 56 150 06EX66-360 00/400 5 55 14 8000 11/56 140/70 446/3 06EX66-660** 400 5 55 14 8000 57 71 05 6 CYLINDER... AIR CONDITIONING... 60HZ 06EX65-160 575 5 68 19 33600 46 57 164 06EX65-360 08-30/460 5 68 19 33600 11/56 140/70 446/3 06EX65-660** 460 5 68 19 33600 57 71 05 06EX175-160 575 5 75 19 33600 46 57 164 06EX175-360 08-30/460 5 75 19 33600 11/56 140/70 446/3 06EX175-660** 460 5 75 19 33600 57 71 05 06EX75-160 575 30 75 19 39100 5 65 176 06EX75-360 08-30/460 30 75 19 39100 135/68 168/84 506/53 06EX75-660** 460 30 75 19 39100 65 81 0 06EX99-160 575 40 99 19 54000 77 97 40 06EX99-360 08-30/460 40 99 19 54000 189/95 36/118 690/345 06EX99-660** 460 40 99 19 54000 97 11 300 6 CYLINDER... AIR CONDITIONING... 50 HZ 06EX65-360 00/400 0 54 19 8000 11/56 140/70 446/3 06EX65-660** 400 0 54 19 8000 57 71 05 06EX175-360 00/400 5 6.5 19 8000 11/56 140/70 446/3 06EX175-660** 400 5 6.5 19 8000 57 71 05 06EX75-360 00/400 30 6.5 19 3600 135/68 168/84 506/53 06EX75-660** 400 30 6.5 19 3600 65 81 0 06EX99-360 00/400 40 8.5 19 45000 189/95 36/118 690/345 06EX99-660** 400 40 8.5 19 45000 97 11 300 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. ** Order the discrete 400/460-3-50/60 volt compressor for part wind start applications only. When ordering, place the letters PW after the model number, (i.e., 06EX99660PW). 11

CARLYLE SEMI-HERMETIC COMPRESSORS 06E COMPRESSOR DATA - THREE PHASE HIGH EFFICIENCY MODELS - ONE PLUGGED HEAD SUCTION CUTOFF UNLOADING OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA 4 CYLINDER... AIR CONDITIONING... 60HZ 06ET150-1( )0 575 15 50 14 000 31 38 98 06ET150-3( )0 08-30/460 15 50 14 000 7/36 90/45 83/14 06ET150-6( )0** 460 15 50 14 000 36 45 14 06ET50-1( )0 575 0 50 14 5300 36 45 10 06ET50-3( )0 08-30/460 0 50 14 5300 87/44 108/54 345/173 06ET50-6( )0** 460 0 50 14 5300 44 54 173 4 CYLINDER... AIR CONDITIONING... 50 HZ 06ET150-30 00/400 15 41.7 14 18300 7/36 90/45 83/14 06ET150-360 00/400 15 41.7 14 18300 7/36 90/45 83/14 06ET150-60** 400 15 41.7 14 18300 36 45 14 06ET150-660** 400 15 41.7 14 18300 36 45 14 06ET50-30 00/400 0 41.7 14 1100 87/44 108/54 345/173 06ET50-360 00/400 0 41.7 14 1100 87/44 108/54 345/173 06ET50-60** 400 0 41.7 14 1100 44 54 173 06ET50-660** 400 0 41.7 14 1100 44 54 173 6 CYLINDER... AIR CONDITIONING... 60 HZ 06ET65-1( )0 575 5 65 19 33600 46 57 164 06ET65-3( )0 08-30/460 5 65 19 33600 11/56 140/70 446/3 06ET65-6( )0** 460 5 65 19 33600 56 70 3 06ET175-1( )0 575 5 75 19 33600 46 57 164 06ET175-3( )0 08-30/460 5 75 19 33600 11/56 140/70 446/3 06ET175-6( )0** 460 5 75 19 33600 56 70 3 06ET75-1( )0 575 30 75 19 39100 5 65 176 06ET75-3( )0 08-30/460 30 75 19 39100 135/68 168/84 506/53 06ET75-6( )0** 460 30 75 19 39100 68 84 53 06ET99-1( )0 575 40 99 19 54000 78 97 40 06ET99-3( )0 08-30/460 40 99 19 54000 189/95 36/118 690/345 06ET99-6( )0** 460 40 99 19 54000 95 118 345 6 CYLINDER... AIR CONDITIONING... 50 HZ 06ET65-30 00/400 5 54 19 8000 11/56 140/70 446/3 06ET65-360 00/400 5 54 19 8000 11/56 140/70 446/3 06ET65-60** 400 5 54 19 8000 56 70 3 06ET65-660** 400 5 54 19 8000 56 70 3 06ET175-30 00/400 5 6.5 19 8000 11/56 140/70 446/3 06ET175-360 00/400 5 6.5 19 8000 11/56 140/70 446/3 06ET175-60** 400 5 6.5 19 8000 56 70 3 06ET175-660** 400 5 6.5 19 8000 56 70 3 06ET75-30 00/400 30 6.5 19 3600 135/68 168/84 506/53 06ET75-360 00/400 30 6.5 19 3600 135/68 168/54 506/53 06ET75-60** 400 30 6.5 19 3600 68 84 53 06ET75-660** 400 30 6.5 19 3600 68 84 53 06ET99-30 00/400 40 8.5 19 45000 189/95 36/118 690/345 06ET99-360 00/400 40 8.5 19 45000 189/95 36/118 690/345 06ET99-60** 400 40 8.5 19 45000 95 118 345 06ET99-660** 400 40 8.5 19 45000 95 118 345 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. ** Order the discrete 400/460-3-50/60 volt compressor for part wind start applications only. When ordering, place the letters PW after the model number, (i.e., 06EX99660PW). Digit indicated by ( ) may be a 6 or a. 1

CARLYLE SEMI-HERMETIC COMPRESSORS REQUIRED CIRCUIT BREAKERS: 06E... 60Hz (AC DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS 06EX150-160 HH83XB447 HH83XE664 06ET175-60,-660 HH83XE65 HH83XE61 06EX175-360 HH83XC409 06ET50-10,-160 HH83XB446 06EX150-360 HH83XB360 HH83XB455 HH83XE6 HH83XB446 06EX175-660 HH83XE630 06ET50-30,-360 HH83XB336 06EX150-660 HH83XB446 06EX75-160 HH83XB44 HH83XB437 06EX50-160 HH83XB446 HH83XE615 06ET50-60,-660 HH83XE66 HH83XE6 06EX75-360 HH83XC439 06ET65-10,-160 HH83XB433 06EX50-360 HH83XB336 HH83XB471 HH83XE664 HH83XB437 06EX75-660 HH83XE64 06ET65-30,-360 HH83XC409 06EX50-660 HH83XE66 06EX99-160 HH83XB45 HH83XB455 06EX66-160 HH83XB436 HH83XE660 06ET65-60,-660 HH83XE65 HH83XE664 06EX99-360 HH83XC437 06ET75-10,-160 HH83XB44 06EX66-360 HH83XC409 HH83XE66 HH83XE615 HH83XB455 06EX99-660 HH83XE66 06ET75-30,-360 HH83XC439 06EX66-660 HH83XE630 06ET150-10 HH83XB447 HH83XB471 06EX65-160 HH83XB436 HH83XE61 06ET75-60,-660 HH83XE643 HH83XE67 06ET150-360 HH83XB360 06ET99-10,-160 HH83XB45 06EX65-360 HH83XC409 HH83XB446 HH83XE660 HH83XB417 06ET150-60,-660 HH83XB446 06ET99-30,-360 HH83XC437 06EX65-660 HH83XE630 06ET175-10,-160 HH83XB436 HH83XE66 06EX175-160 HH83XB436 HH83XE664 06ET99-60,-660 HH83XE66 06ET175-30,-360 HH83XC409 HH83XB455 REQUIRED CIRCUIT BREAKERS: 06E... 50Hz COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS HH83XE61 HH83XE615 06ET65-60 06EX150-360 HH83XB360 06EX75-360 HH83XC439 06ET65-660 HH83XE65 HH83XB446 HH83XB471 HH83XE664 06ET175-30 HH83XE6 06EX75-660 HH83XE64 HH83XC409 06ET175-360 06EX50-360 HH83XB336 HH83XE660 HH83XB455 HH83XB437 06EX99-360 HH83XC437 06ET175-60 06EX50-660 HH83XE66 HH83XE66 06ET175-660 HH83XE65 HH83XE664 06EX99-660 HH83XE66 HH83XE615 06ET75-30 06EX66-360 HH83XC409 HH83XE61 HH83XC439 06ET150-30 06ET75-360 HH83XB455 HH83XB360 HH83XC471 06ET150-360 06EX66-660 HH83XE630 HH83XB446 06ET75-60 HH83XE643 HH83XE67 HH83XE6 06ET75-660 06ET50-30 06EX65-360 HH83XC409 HH83XB336 HH83XE660 06ET50-360 06ET99-30 HH83XB417 HH83XB437 HH83XC437 06ET99-360 06EX65-660 HH83XE630 06ET50-60 HH83XE66 HH83XE66 HH83XE664 06ET50-660 06ET99-60 HH83XE66 06EX175-360 HH83XC409 HH83XE664 06ET99-660 06ET65-30 HH83XB455 HH83XC409 06ET65-660 06EX175-660 HH83XE630 HH83XB455 NOTE: Circuit breakers listed for Discrete 460V Compressors are sized for part wind start. This circuit breaker is used when Multi-Volt Compressor is connected for 08/3W PWS operation. This circuit breaker is used when Multi-Volt Compressor is connected for 08/30V operation. This circuit breaker is used when Multi-Volt Compressor is connected for 460V operation. Accessory Screw Package for Circuit Breakers (Required) - P/N 06EA66010 (not used with HH83XA4_- Series Breakers) Generally, for a compressor changeout in a Carrier/BDP unit, the use of existing circuit breaker(s) is acceptable. 13

CARLYLE REFRIGERATION COMPRESSORS 06D REFRIGERATION AND MEDIUM TEMPERATURE DUTY COMPRESSORS APPLICATION DATA For mounting configuration, dimensions and weights, refer to outline drawings in the Totaline Network Parts Catalog. CAPACITY (000 BTUH) -5 SST 0 SST 15 SST 40 SST CFM 110 SCT 10 SCT 110 SCT 10 SCT NO. @ SUCTION TEMP. RANGE* 65 SGT 65 SGT 65 SGT 60 SGT MODEL OF 1750 ( F) 0 SC 0 SC 0 SC 0 SC NO. HP CYL. RPM R-50 R-1 R- R-50 R-50 R-1/134a R- 06DR109 8.7-40 to 0** -10 to 40-9.9-14.6/- - 06DM808 3 8.0-10 to 40 - -10 to 50-3.1-35.6 06DR013 3 4 13.1-40 to 0** -10 to 40-11.7 -.7/19.5-06DM313 5 4 13.1-10 to 40-10 to 40-10 to 50-35.1 0.4/- 55.6 06DR316 5 4 15.9-40 to 10** -10 to 40-16. - 9.1/6.9-06DM316 5 4 15.9-10 to 40-10 to 40-10 to 50-45.0 6.6/- 69.0 06DR718 5 4 18.3-40 to 10** -10 to 40-0.4-33.7/31.9-06DR80 6-1/ 4 0.0 40 to 40** -10 to 40-10 to 50.3-37.4/35.6 9.5 06DR74 6-1/ 6 3.9-40 to 40** -10 to 40-10 to 50 5.6-43.7/40.1 109.6 06DR8 7-1/ 6 8.0 40 to 40** -10 to 40-10 to 50 31.0-51.3/49. 18. 06DR337 10 6 37.1 40 to 10** -10 to 40-4.7-69.3/67.7-06DM337 10 6 37.1-10 to 30-10 to 40-10 to 35-111.1 65.6/- 165.9 * Condensing temperature range 80 to 10 F. ** Cylinder Head Cooling Fan is required to operate at minimum suction temperatures. 14

CARLYLE REFRIGERATION COMPRESSORS 06D COMPRESSOR DATA - SINGLE PHASE MEDIUM TEMPERATURE (NO UNLOADING) OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA CYLINDER... MEDIUM TEMP.... 60 HZ 06DM8086-0350 30 3 8 3.5 800 17.0.0 70.0 06DM1096-0350 30 8.7 3.5 800 1.5 15.6 50.0 4 CYLINDER... MEDIUM TEMP.... 60 HZ 06DM3136-0350 30 5 13.1 5 6600 8.0 35.0 100.0 06DM3166-0350 30 5 15.9 5 6600 8.0 35.0 100.0 06DM3186-0350 30 5 18.3 7 6600 8.0 35.0 100.0 06DM5186-0350 30 5.5 18.3 7 7700 36.8 46.0 148.0 06DM7186-0350 30 5 18.3 7 6600 8.0 35.0 100.0 06D COMPRESSOR DATA - THREE PHASE MEDIUM TEMPERATURE (NO UNLOADING) OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA CYLINDER... MEDIUM TEMP.... 60 HZ 06DM8086-3150 575 3 8 3.5 4100 5.6 7.0 8.4 06DM8086-350 08/30 3 8 3.5 4100 14.0 17.4 71.0 06DM8086-3650 460 3 8 3.5 4100 7.0 8.7 35.5 CYLINDER... MEDIUM TEMP.... 50 HZ 06DM8086-3650 400 3 6.7 3.5 3400 7.0 8.7 35.5 4 CYLINDER... MEDIUM TEMP.... 60 HZ 06DM3136-3150 575 5 13.1 5 650 8.6 10.8 40.0 06DM3136-350 08/30 5 13.1 5 650 1.5 7.0 100.0 06DM3136-3650 460 5 13.1 5 650 10.8 13.5 50.0 06DM3166-3150 575 5 15.9 5 650 8.6 10.8 40.0 06DM3166-350 08/30 5 15.9 5 650 1.5 7.0 100.0 06DM3166-3650 460 5 15.9 5 650 10.8 13.5 50.0 4 CYLINDER... MEDIUM TEMP.... 60 HZ 06DM3136-3650 400 5 11 5 500 10.8 13.5 50.0 06DM3166-3650 400 5 13 5 500 10.8 13.5 50.0 6 CYLINDER... MEDIUM TEMP.... 60 HZ 06DM3376-3150 575 10 37.1 10 16500 17.9 5.0 91.0 06DM3376-3650 460 10 37.1 10 16500.1 31.0 114.0 06DM3376-350 08.30 10 37.1 10 16500 44.3 6.0 8.0 6 CYLINDER... MEDIUM TEMP.... 50 HZ 06DM3376-3650 400 8 31.0 10 13700.1 31.0 114.0 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. 15

CARLYLE REFRIGERATION COMPRESSORS 06D COMPRESSOR DATA - SINGLE PHASE LOW TEMPERATURE REFRIGERATION OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA CYLINDER... LOW TEMP. REFRIGERATION... 60HZ 06DR1096-3350 08/30-1 8.7 3.5 3400 17.0 4.0 110.0 4 CYLINDER... LOW TEMP. REFRIGERATION... 60HZ 06DR0136-3350 08/30-1 3 13.1 5 4800 3.3 3.6 100.0 06DR3166-3350 08/30-1 5 15.9 5 6400 8.6 40.0 150.0 06DR7186-3350 08/30-1 5 18.3 7 6400 8.6 40.0 150.0 06D COMPRESSOR DATA - THREE PHASE LOW TEMPERATURE REFRIGERATION OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA CYLINDER... LOW TEMP. REFRIGERATION... 60HZ 06DR1096-3150 575 8.7 3.5 3100 3.1 4.4 1.3 06DR1096-350 80/30 8.7 3.5 3100 8.8 1.1 53.3 06DR1096-3650 460 8.7 3.5 3100 3.8 5.5 6.6 CYLINDER... LOW TEMP. REFRIGERATION... 50HZ 06DR109-3650 400 7.5 3.5 600 3.8 5.5 6.6 4 CYLINDER... LOW TEMP. REFRIGERATION... 60HZ 06DR0136-3150 575 3 13.1 5 4300 5.6 7.0 8.4 06DR0136-350 08/30 3 13.1 5 4300 14.0 17.4 71.0 06DR0136-3650 460 3 13.1 5 4300 7.0 8.7 35.5 06DR3166-3150 575 5 15.9 5 650 8.6 10.8 40.0 06DR3166-350 08/30 5 15.9 5 650 1.5 7.0 100.0 06DR3166-3650 460 5 15.9 5 650 10.8 13.5 50.0 06DR7186-3150 575 5 18.3 7 650 8.6 10.8 40.0 06DR7186-350 08/30 5 18.3 7 650 1.5 7.0 100.0 06DR7186-3650 460 5 18.3 7 650 10.8 13.5 50.0 06DR806-3150 575 6.5 0 7 9800 1.6 17.6 64.0 06DR806-350 08/30 6.5 0 7 9800 31.5 44.0 160.0 06DR806-3650 460 6.5 0 7 9800 15.7.0 80.0 4 CYLINDER... LOW TEMP. REFRIGERATION... 50 HZ 06DR013-3650 400 3 11 5 3400 7.0 8.7 35.5 06DR316-3650 400 5 13 5 500 10.8 13.5 50.0 06DR718-3650 400 5 15 7 500 10.8 13.5 50.0 06DR80-3650 400 6.5 16.7 7 800 31.5 44.0 160.0 6 CYLINDER... LOW TEMP. REFRIGERATION... 60 HZ 06DR746-3150 575 6.5 3.9 10 9800 1.6 17.6 64.0 06DR746-350 08/30 6.5 3.9 10 9800 31.5 44.0 160.0 06DR746-3650 460 6.5 3.9 10 9800 15.7.0 80.0 06DR86-3150 575 7.5 8 10 1800 15.9. 79.0 06DR86-350 08/30 7.5 8 10 1800 39.7 55.5 198.0 06DR86-3650 460 7.5 8 10 1800 19.9 7.8 99.0 06DR3376-3150 575 10 37.1 10 16500 17.9 5.0 91.0 06DR3376-350 08/30 10 37.1 10 16500 44.3 6.0 8.0 06DR3376-3650 460 10 37.1 10 16500.1 31.0 114.0 6 CYLINDER... LOW TEMP. REFRIGERATION... 50 HZ 06DR74-3650 400 6.7 0 10 800 15.7.0 80.0 06DR8-3650 400 8 3.3 10 10700 19.9 7.8 99.0 06DR337-3650 400 9 31 10 13700.1 31.0 114.0 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. 16

CARLYLE REFRIGERATION COMPRESSORS REQUIRED CIRCUIT BREAKERS: 06D... 60Hz (REF. DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS 06DR1096-3100 HH83XB498 06DR86-300 HH83XB307 06DM3166-300 HH83XB316 06DR1096-300 HH83XB49 06DR86-3600 HH83XB438 06DM3166-3600 HH83XB443 06DR1096-3600 HH83XB495 06DR3376-3100 HH83XB451 06DM8186-0100 HH83XB450 06DR0136-3100 HH83XB496 06DR3376-300 HH83XB305 06DM8186-0600 HH83XB419 06DR0136-300 HH83XB490 06DR3376-3600 HH83XB45 06DM8186-100 HH83XB306 06DR0136-3600 HH83XB494 06DM8086-0300 HH83XB480 06DM846-0100 HH83XB419 06DR3166-3100 HH83XB497 06DM1096-0300 HH83XB481 06DM846-0600 HH83XB400 06DR3166-300 HH83XB415 06DM8096-0300 HH3XB480 06DM846-100 HH83XB43 06DR3166-3600 HH83XB443 06DM3136-0300 HH83XB483 06DM3376-3100 HH83XB451 06DR7186-3100 HH83XB497 06DM3166-0300 HH83XB483 06DM3376-3600 HH83XB45 06DR7186-300 HH83XB415 06DM3186-0300 HH83XB483 06DM3376-300 HH83XB305 06DR7186-3600 HH83XB443 06DM5186-0300 HH83XB484 06DM3376-1400 HH83XE630 06DR806-3100 HH83XB450 06DM7186-0300 HH83XB483 06DM3376-1500 HH83XE604 06DR806-300 HH83XB306 06DM8086-300 HH83XB490 06DM5376-0100 HH83XB440 06DR806-3600 HH83XB419 06DM8086-3600 HH83XB494 06DM5376-0600 HH83XB4 06DR746-3100 HH83XB450 06DM3136-3100 HH83XB497 06DM5376-100 HH83XB311 06DR746-300 HH83XB306 06DM3136-300 HH83XB316 06DM5376-1400 HH83XE633 06DR746-3600 HH83XB419 06DM3136-3600 HH83XB443 06DM5376-1500 HH83XE643 06DR86-3100 HH83XB419 06DM3166-3100 HH83XB497 REQUIRED CIRCUIT BREAKERS: 06D... 50Hz (REF. DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS 06DR109-3600 HH83XB495 06DR74-3600 HH83XB419 06DM316-3600 HH83XB443 06DR013-3600 HH83XB494 06DR8-3600 HH83XB438 06DM818-0600 HH83XB419 06DR316-3600 HH83XB443 06DR337-3600 HH83XB45 06DM84-0600 HH83XB400 06DR718-3600 HH83XB415 06DM808-3600 HH83XB494 06DM337-3600 HH83XB45 06DR80-3600 HH83XB419 06DM313-3600 HH83XB443 06DM537-0600 HH83XB4 17

CARLYLE REFRIGERATION COMPRESSORS 06E REFRIGERATION AND MEDIUM TEMPERATURE DUTY COMPRESSORS APPLICATION DATA For mounting configuration, dimensions and weights, refer to outline drawings in the Totaline Network Parts Catalog. CAPACITY (000 BTUH) -5 SST 0 SST 15 SST 40 SST CFM 110 SCT 10 SCT 110 SCT 10 SCT NO. @ SUCTION TEMP. RANGE* 65 SGT 65 SGT 65 SGT 60 SGT MODEL OF 1750 ( F) 0 SC 0 SC 0 SC 0 SC NO. HP CYL. RPM R-50 R-1 R- R-50 R-50 R-1 R- 06EY150 15 4 50.3-40 to 10** -10 to 40-54.5-9.1-06EZ150 15 4 50.3-10 to 40-10 to 40-10 to 40-139.0 8.6 19.7 06EY166 0 4 66.0-40 to 10** -10 to 40-68.0-109.0-06EZ66 5 4 66.0-10 to 40 - -10 to 50-180.0-77.0 06EY165 0 6 65.0-40 to 10** -10 to 40-68.3-11.7-06EY175 0 6 75.4-40 to 1** -10 to 40-78.6-135.7-06EZ175 5 6 75.4-10 to 40-10 to 40-10 to 50-07.5 11.0 33.8 06EY099 30 6 99.0-40 to 10** -10 to 40-104.0-17.4-06EZ199 35 6 99.0-10 to 40-10 to 40-10 to 50-80.0 163.4 4.6 * Condensing temperature range 80 to 10 F. ** Cylinder Head Cooling Fan is required to operate at minimum suction temperatures. 18

CARLYLE REFRIGERATION COMPRESSORS 06E COMPRESSOR DATA - THREE PHASE LOW TEMPERATURE & MEDIUM TEMPERATURE REFRIGERATION OIL COMPRESSOR CHG. MAX. MAX. MODEL NO. VOLT HP CFM PINTS WATTS RLA* MTA LRA 4 CYLINDER... LOW TEMP. REFRIGERATION...60 HZ 06EY150-140 575 15 50.3 14 000 31 38 98 06EY150-340 08-30/460 15 50.3 14 000 7/36 90/45 83/14 06EY166-140 575 0 66 14 5300 36 45 10 06EY166-340 08-30/460 0 66 14 5300 87/44 108/54 345/173 06EY166-640** 460 0 66 14 5300 45 56 150 4 CYLINDER... LOW TEMP. REFRIGERATION... 50 HZ 06EY150-340 00/400 15 41.7 14 18300 7/36 90/45 83/14 06EY166-340 00/400 0 55 14 8000 87/44 108/54 345/173 06EY166-640** 400 0 55 14 8000 45 56 150 6 CYLINDER... LOW TEMP. REFRIGERATION... 60HZ 06EY165-140 575 0 65 19 5300 36 45 10 06EY165-340 08-30/460 0 65 19 5300 87/44 108/54 345/173 06EY165-640** 460 0 65 19 5300 44 54 173 06EY175-140 575 0 75.4 19 5300 36 45 10 06EY175-340 08-30/460 0 75.4 19 5300 87/44 108/54 345/173 06EY175-640** 460 0 75.4 19 5300 45 56 150 06EY099-140 575 30 99 19 39100 5 65 176 06EY099-340 08-30/460 30 99 19 39100 135/68 168/84 506/53 06EY099-640** 460 30 99 19 39100 65 81 0 6 CYLINDER... LOW TEMP. REFRIGERATION... 50 HZ 06EY165-340 00/400 0 54 19 1100 87/44 108/54 345/173 06EY165-640** 400 0 54 19 1100 44 54 173 06EY175-340 00/400 0 6.5 19 1100 87/44 108/54 345/173 06EY175-640** 400 0 6.5 19 1100 45 56 150 06EY099-340 00/400 30 8 5 19 3600 135/68 168/84 506/53 06EY099-640** 400 30 8.5 19 3600 65 81 0 4 CYLINDER... MEDIUM TEMP. REFRIGERATION... 60 HZ 06EZ150-170 575 15 50.3 14 000 31 38 98 06EZ150-370 08-30/460 15 50.3 14 000 7/36 90/45 83/14 06EZ66-170 575 5 66 14 33600 46 57 164 06EZ66-370 08-30/460 5 66 14 33600 11/56 140/170 446/3 06EZ66-670** 460 5 66 14 33600 57 71 05 4 CYLINDER... MEDIUM TEMP. REFRIGERATION... 50 HZ 06EZ150-370 00/400 15 41.7 14 18300 7/36 90/45 83/14 06EZ66-370 00/400 5 55 14 8000 11/56 140/170 446/3 06EZ66-670** 400 5 55 14 8000 57 71 05 6 CYLINDER... MEDIUM TEMP. REFRIGERATION... 60 HZ 06EZ175-170 575 5 75.4 19 33600 46 57 164 06EZ175-370 08-30/460 5 75.4 19 33600 11/56 140/70 446/3 06EZ175-670** 460 5 75 4 19 33600 57 71 05 06EZ199-170 575 35 99 19 47600 65 8 1 06EZ199-370 08-30/460 35 99 19 47600 155/77 193/96 610/305 06EZ199-670** 460 35 99 19 47600 8 10 65 6 CYLINDER... MEDIUM TEMP. REFRIGERATION... 50 HZ 06EZ175-370 00/400 5 6.5 19 8000 11/56 140/170 446/3 06EZ175-670** 400 5 6.5 19 8000 57 71 05 06EZ199-370 00/400 35 8.5 19 39700 155/77 193/96 610/305 06EZ199-670** 400 35 8 5 19 39700 8 10 65 * This is the maximum rated load amp rating for the compressor motor. The overcurrent protection (circuit breaker) in the unit may result in much lower RLA values. ** Order the discrete 400/460-3-50/60 volt compressor for part wind start applications only. When ordering, place the letters PW after the model number, (i.e., 06EX99660PW) Generally, for a compressor changeout in a Carrier/BDP unit, the use of existing circuit breaker(s) is acceptable. 19

CARLYLE REFRIGERATION COMPRESSORS REQUIRED CIRCUIT BREAKERS: 06E... 60Hz (REF. DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS 06EY150-140 HH83XA460 06EY175-140 HH83XA461 HH83XE61 HH83XE633 HH83XE6 06EZ66-370 HH83XC409 06EY150-340 HH83XB360 06EY175-340 HH83XB336 HH83XA46 HH83XA463 HH83XA44 06EZ66-670 HH83XE630 06EY166-140 HH83XA461 06EY175-640 HH83XE66 06EZ175-170 HH83XA469 HH83XE6 06EY099-140 HH83XA430 HH83XE61 06EY166-340 HH83XB336 HH83XE65 06EZ175-370 HH83XC409 HH83XA44 06EY099-340 HH83XC439 HH83XA46 06EY166-640 HH83XE66 HH83XA45 06EZ175-670 HH83XE630 06EY165-140 HH83XA461 06EY099-640 HH83XE64 06EZ199-170 HH83XA453 HH83XE6 06EZ150-170 HH83XA460 HH83XE609 06EY165-340 HH83XB336 HH83XE633 06EZ199-370 HH83XC43 HH83XB437 06EZ150-370 HH83XB356 HH83XA547 06EY165-640 HH83XE66 HH83XA463 06EZ199-670 HH83XE63 06EZ66-170 HH83XA469 REQUIRED CIRCUIT BREAKERS: 06E... 50Hz (REF. DUTY) COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT COMPRESSOR CIRCUIT MODEL NO. BREAKERS MODEL NO. BREAKERS MODEL NO. BREAKERS HH83XE633 06EY175-640* HH83XE66 06EZ66-670 HH83XE630 06EY150-340 HH83XB360 HH83XE65 HH83XE61 HH83XA463 06EY099-340 HH83XC439 06EZ175-370 HH83XC409 HH83XE6 HH83XA45 HH83XA46 06EY166-340 HH83XB336 06EY099-640 HH83XE64 06EZ175-670 HH83XE630 HH83XA44 HH83XE633 HH83XE609 06EY166-640 HH83XE66 06EZ150-370 HH83XB356 06EZ199-370 HH83XC43 HH83XE6 HH83XA463 HH83XA547 06EY165-340 HH83XB336 HH83XE61 06EZ199-670 HH83XE63 HH83XB437 06EZ66-370 HH83XC409 06EY165-640 HH83XE66 HH83XA46 HH83XE6 06EY175-340 HH83XB336 HH83XA44 NOTE: Circuit breakers listed for Discrete 460V Compressors are sized for part wind start. This circuit breaker is used when Multi-Volt Compressor is connected for 08/3W PWS operation. This circuit breaker is used when Multi-Volt Compressor is connected for 08/30V operation. This circuit breaker is used when Multi-Volt Compressor is connected for 460V operation. Accessory Screw Package for Circuit Breakers (Required) - P/N 06EA66010 (not used with HH83XA4_- Series Breakers) Generally, for a compressor changeout in a Carrier/BDP unit, the use of existing circuit breaker(s) is acceptable. 0

CARLYLE REFRIGERATION COMPRESSORS TOTALINE COMPRESSOR OILS - FOR CARLYLE AND TOTALINE COMPRESSORS REFRIGERANT R-1, REFRIGERANT R-507, REFRIGERANT R-507, REFRIGERANT R-134A R- (L & H TEMP.) R-404A (MED. TEMP) R-404A (LOW. TEMP) (M & H TEMP) COMPRESSOR TOTALINE TOTALINE TOTALINE TOTALINE MODEL OIL MODEL PART NO. OIL MODEL PART NO. OIL MODEL PART NO. OIL MODEL PART NO. Carlyle 06D, E Zerol 150 P903-001 SW68 P903-1001 E68 P903-175 SW68 P903-1001 semi-hermetic P903-005 P903-105 (Do not use SW-68 P903-1701 P903-105 P903-05 P903-1005 for Low Temp) P903-1705 P903-1005 RO 15 P903-0101 P903-0105 P903-0155 Carlyle 5F/H open Zerol 150 P903-001 SW68 P903-1001 E68 P903-175 SW68 P903-1001 P903-005 P903-105 (Do not use SW-68 P903-1701 P903-105 P903-05 P903-1005 for Low Temp) P903-1705 P903-1005 RO 15 P903-0101 P903-0105 P903-0155 Carlyle 05T/06T E-100 P903-1501 E-100 P903-1501 E-100 P903-1501 E-100 P903-1501 Screw (74) P903-1505 P903-1505 P903-1505 P903-1505 P903-155 P903-155 P903-155 P903-155 Carlyle 06N Screw N/A N/A N/A N/A N/A N/A SW-0 P903-101 (104mm Global Chiller) (R-134a Only) P903-15 P903-105 Millennium Scroll Zerol 150 P903-001 N/A N/A N/A N/A Mobil Arctic 68 Technologies P903-005 Model now P903-05 obsolete 1

TOTALINE OILS TOTALINE OIL MINERAL REFRIGERATION OILS VACUUM PUMP OILS This is a refined oil used specifically for air conditioning and refrigeration. The low moisture content means less failure. A non-foaming, wax-free oil to prevent plugged capillaries and sticking expansion valves. OEM approved by most manufacturers. A highly purified purpose vacuum pump oil that cleans and lubricates. The quart bottle (9.5 liters) has a convenient flip-top-cap. P/N SIZE VISCOSITY P903-0101 1 GAL (3.8 liters) 150 P903-0105 5 GAL (18.9 liters) 150 P903-0155 55 GAL (08. liters) 150 P903-001 1 GAL (3.8 liters) 300 P903-005 5 GAL (18.9 liters) 300 P903-055 55 GAL (08. liters) 300 P903-0301 1 GAL (3.8 liters) 500 P903-0305 5 GAL (18.9 liters) 500 P903-0355 55 GAL (08. liters) 500 P/N SIZE P903-063 1 QT (.95 liters) P903-0601 1 GAL(3.8liters P903-0605 5 GAL (18.9 liters) P903-0655 55 GAL (08. liters) ALKYLBENZENE REFRIGERATION OILS POLYOL-ESTER OILS These environmentally friendly products are specifically formulated to use with the non-cfc refrigerant R-134a. The base fluids have been engineered to be totally miscible with R134a over a very wide temperature range while maintaining excellent lubricating properties. P/N SIZE TYPE P903-105 1 QT (.95 liters) SW68 P903-1001 1 GAL (3.8 liters) SW68 P903-1005 5 GAL (18.9 liters) SW68 P903-115 1 QT (.95 liters) SW3 P903-1101 1 GAL (3.8 liters) SW3 P903-1105 5 GAL (18.9 liters) SW3 P903-15 1 QT (,95 liters) SW0 P903-101 1 GAL (3.8 liters SW0 P903-105 5 GAL (18.9 liters) SW0 The Z-Series are high quality synthetic Alkylbenzene Refrigeration fluids for us with HCFC, CFC and ammonia refrigerants in refrigeration and air conditioning applications. Due to superior miscibility, Totaline Z-Series lubricants are excellent for systems utilizing environmentally sound refrigerants MP39, MP60, HP80 or HP81. Totaline Z-Series are superior products for all R-, R-13 and R-50 Systems, particularly at low temperatures. Z-00TD is formulated with a unique additive package providing extreme pressure (EP) lubricity and foam control at operating conditions. P/N SIZE TYPE P903-05 1 QT (.95 liters) Z-150 P903-001 1 GAL (3.8 liters) Z-150 P903-005 5 GAL (18.9 liters) Z-150 P903-15 1 QT (.95 liters) Z-00TD P903-101 1 GAL (3.8 liters) Z-00TD P903-105 5 GAL (18.9 liters) Z-00TD P903-5 1 QT (.95 liters) Z-300 P903-01 1 GAL (3.8 liters Z-300 P903-05 5 GAL (18.9 liters) Z-300

CARLYLE SEMI-HERMETIC COMPRESSORS / ACCESSORIES SUCTION CUTOFF UNLOADING VS. HOT GAS BYPASS UNLOADING Since 1981 many of the Commercial Products Carrier produced with 06E compressors utilized Suction Cutoff Unloading in place of Hot Gas Bypass Unloading. It is easy to identify a suction cutoff unloading compressor from a hot gas bypass unloading compressor. This can be done in one of two ways: #1) The Finished Goods (new) compressor model number is different than the hot gas bypass model number. SUCTION CUTOFF 06E 75 660 Compressor Compressor Family Size Voltage - one electric unloader 3 - two electric unloaders 4 - one pressure unloader 5 - two pressure unloaders 6 - one electric unloader 7 - two electric unloaders 8 - one pressure unloader 9 - two pressure unloaders Reversed Center Head (6 cylinder) HOT GAS BYPASS 06E B 75 660 Compressor Compressor Family Size Voltage B - one electric unloader C - two electric unloaders D - one pressure unloader E - two pressure unloaders J - one electric unloader K - two electric unloaders L - one pressure unloader N - two pressure unloaders Reversed Center Head (6 cylinder) #) The unloading heads themselves physically look different. Suction Cutoff The parts used in Hot Gas Bypass are different from those used in Suction Cutoff Unloading. These differences are: PART NUMBERS HOT GAS SUCTION BYPASS CUTOFF Valve Plate Package 06EA660105 06EA660137 Cylinder Head Gasket 06EA503314 06EA503334 Cylinder Head - 06EA50354 The valve plate gasket for both Hot Gas Bypass and Suction Cutoff is 06EA504884. Both hot gas bypass and suction cutoff use the same Control Valve Packages: Pressure Control Valve 06EA660100 Electric Control Valve 06EA660135 These control valves are similar to those you used in the past except that the bypass piston is now separate from the valve and the pressure control valve has had internal modifications that allow it to operate on suction cutoff applications. 3 Hot Gas Bypass Suction Cutoff Valve Plate Suction Cutoff Cylinder Head Gasket

CARLYLE SEMI-HERMETIC COMPRESSORS / ACCESSORIES 06D SUCTION CUTOFF UNLOADING KITS ELECTRIC CAPACITY CONTROL MODIFICATION PACKAGE PART NO.: 06DA660089 The capacity control valve in this package is actuated by an electric solenoid. The solenoid is either energized or de-energized by the action of an external controller. The solenoid coil is not supplied with this package. This package can be used to (1) convert an 06D compressor with hot gas bypass unloading to electrically operated suction cutoff unloading, () add unloading or (3) add a second bank of unloading to an 06D compressor. The kit consists of the following: - Cylinder Head Assembly (incl. capacity control valve) - Valve Plate Gasket - Cylinder Head Gasket - Cylinder Head Bolts - Instructions - Solenoid Coils for electric unloader valve. PART NO. VOLTAGE EF19ZE04 4V EF19ZE10 10V EF19ZE40 08-40V PRESSURE CAPACITY CONTROL MODIFICATION PACKAGE PART NO.: 06DA660090 NOT RECOMMENDED FOR REFRIGERATION APPLICATIONS The capacity control valve in this package is controlled by suction pressure and actuated by discharge pressure. This package can be used to (1) convert an 06D compressor with hot gas bypass unloading to suction cutoff unloading, () add unloading, or (3) add a second bank of unloading to an 06D compressor. The kit consists of the following: - Cylinder Head Assembly (incl. capacity control valve) - Valve Plate Gasket - Cylinder Head Gasket - Cylinder Head Bolts - Instructions SUCTION CUTOFF UNLOADING REPAIR KIT PART NO.: 06DA660111 This kit contains the parts used internally for the suction cutoff unloading head. It is used for both electric and pressure operated suction cutoff unloading applications. The kit does not contain the capacity control valve. The kit consists of the following: - Piston and Ring - Valve Body - Spring - Capacity Control Valve Gasket - Cover Gasket - Strainer - Instructions Suction cutoff unloading is the "state of the art unloading method for the 06D/06E compressors. There are substantial energy savings and improved compressor reliability when a hot gas bypass unloading system is replaced with suction cutoff unloading. 06DA660089 06DA660090 ELECTRICALLY OPERATED P/N: 06DA660089 PRESSURE OPERATED P/N: 06DA660090 Not Recommended For Refrigeration Application 4

CARLYLE SEMI-HERMETIC COMPRESSORS / ACCESSORIES 06E SUCTION CUTOFF UNLOADING KIT ELECTRIC CAPACITY CONTROL MODIFICATION PACKAGE PART NO.: 06EA660138 The capacity control valve in this package is actuated by an electric solenoid. The solenoid is either energized or de-energized by the action of an external controller. The solenoid coil is not supplied with this package. This package can be used to (1 ) convert an 06E compressor with hot gas bypass unloading to electrically operated suction cutoff unloading, () add unloading or (3) add a second bank of unloading to an 06E compressor. The kit consists of the following: - Cylinder Head Assembly (incl. capacity control valve) - Valve Plate Gasket (AC & Ref.) - Suction Valves - Cylinder Head Gasket - Capscrews - Washers - Instructions - Solenoid Coils for electric unloader valve. PART NO. VOLTAGE EF19ZE04 4V EF19ZE10 10V EF19ZE40 08-40V PRESSURE CAPACITY CONTROL MODIFICATION PACKAGE PART NO.: 06EA660139 NOT RECOMMENDED FOR REFRIGERATION APPLICATIONS The capacity control valve in this package is controlled by suction pressure and actuated by discharge pressure. This package can be used to (1) convert an 06E compressor with hot gas bypass unloading to pressure operated suction cutoff unloading, () add unloading, or (3) add a second bank of unloading to an 06E compressor. The kit consists of the following: - Cylinder Head Assembly (incl. capacity control valve) - Valve Plate Gasket (AC & Ref.) - Suction Valves - Cylinder Head Gasket - Capscrews - Washers - Instructions SUCTION CUTOFF UNLOADING REPAIR KIT PART NO.: 06EA660079 This kit contains the parts used internally for the suction cutoff unloading head. It is used for both electric and pressure operated suction cutoff unloading applications. The kit does not contain the capacity control valve. The kit contains the following: - Piston and Ring - Cover Gasket - Valve Body - Strainer - Spring - Instructions - Capacity Control Valve Gasket Suction cutoff unloading is the "state of the art unloading method for the 06D/06E compressors. There are substantial energy savings and improved compressor reliability when a hot gas bypass unloading system is replaced with suction cutoff unloading. 5 P/N: 06EA660138 Electric Suction Cutoff Unloading Modification Package (Pictured) Electric Capacity Control Valve (Less Solenoid) Parts also contained in O6E660079 Suction Cutoff Repair Package CONTROL VALVE KITS These kits contain the capacity control valve. The 06D and 06E compressors use the same capacity control valve. (The piston assembly is used with hot gas bypass unloading only). 06EA660100 Pressure operated kit contains the following: - Pressure Operated Capacity Control Valve - Capacity Control Valve Gasket - Piston Assembly (for HGBP) - Wrench Instructions - Instructions 06EA660135 Electrically operated kit contains the following: - Electrically Operated Capacity Control Valve (Select appropriate solenoid coil: 4, 10, or 08-40V) - Capacity Control Valve Gasket - Piston Assembly (for HGBP) - Instructions * * * * * *