The Effect of DC Machine Adjustment on Loop Unbalance

Similar documents
Commutation Assembly and Adjustment Details Make the Difference Gary Lozowski Morgan Advanced Materials June 13, MEMSA Technical Symposium

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

ELEN 236 DC Motors 1 DC Motors

ECET 211 Electric Machines & Controls Lecture 5-1 Electric Motors. Lecture 5-1 Electric Motors

DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR


2006 MINI Cooper S GENINFO Starting - Overview - MINI

Historical Development

Principles of Electrical Engineering

INTRODUCTION Principle

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

SYLLABUS. osmania university UNIT - I UNIT - II UNIT - III UNIT - IV CHAPTER - 1 : PRINCIPLES OF ELECTRO-MECHANICAL ENERGY CONVERSION CHAPTER - 2 :

Chapter 4 DC Machines

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

Module 9. DC Machines. Version 2 EE IIT, Kharagpur

AC Motors vs DC Motors. DC Motors. DC Motor Classification ... Prof. Dr. M. Zahurul Haq

Basic Motor Theory. Introduction

PHY 152 (ELECTRICITY AND MAGNETISM)

2014 ELECTRICAL TECHNOLOGY

FARADAY S LAW ELECTROMAGNETIC INDUCTION

CURRENT ELECTRICITY - II

2 Principles of d.c. machines

Electrical Machines -II

UNIT I D.C. MACHINES PART A. 3. What are factors on which hysteresis loss? It depends on magnetic flux density, frequency & volume of the material.

ECEg439:-Electrical Machine II

Carbon Brush Performance on Slip Rings

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL ELECTRICAL MACHINES

INDUCTANCE FM CHAPTER 6

Electrical Machines-I (EE-241) For S.E (EE)

Application Information

MAGNETIC EFFECTS OF ELECTRIC CURRENT

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Automotive Electrical Systems

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

GENERATOR DATA MAY 10, 2018

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR

GENERATOR DATA SEPTEMBER 29, 2015

Contents. Review of Electric Circuitd. Preface ;

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014)

Spec Information. Reactances Per Unit Ohms

Ohm s Law. 1-Introduction: General Physics Laboratory (PHY119) Basic Electrical Concepts:

DESIGN OF DC MACHINE

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR

DC motor theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Electrical machines - generators and motors

Starting Systems & Traction Motor Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 18 Pages Starting & Traction Motor Systems 62 Points

AIR COOLED RECTIFIER SPECIFICATION S-50-A

BELT-DRIVEN ALTERNATORS

AGN Unbalanced Loads

Power Losses. b. Field winding copper losses Losses due to the shunt field (i sh 2 R sh. ) or series field winding (i s 2 R s

Renewable Energy Systems 13

CHAPTER 3 BRUSHLESS DC MOTOR

BM Series. DC Brushless Rotary Servomotors. Standard NEMA frame sizes. Neodymium iron boron rare-earth magnets maximize performance

Design of Brushless Permanent-Magnet Machines. J.R. Hendershot Jr. T.J.E. Miller


Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

DC Motor and Generator Theory By

ELECTROMAGNETISM. 1. the number of turns. 2. An increase in current. Unlike an ordinary magnet, electromagnets can be switched on and off.

DIVISION 7 GENERATORS AND MOTORS

MAGNETIC FIELD DUE TO A CURRENT CARRYING CONDUCTOR

Question 2: Around the bar magnet draw its magnetic fields. Answer:

1991 Mazda MX-5 Miata. STARTER - DIRECT DRIVE ELECTRICAL Mazda Starters - Direct Drive ELECTRICAL Mazda Starters - Direct Drive

Faraday s Law of Induction III

Practical Manual Lab: Electrical Technology

of coper bars of equal size, each insulated from the

EE462. Electric Machines PROJECT REPORT VARIABLE SPEED DC MOTOR DRIVE. Done By:

AP Physics B: Ch 20 Magnetism and Ch 21 EM Induction

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

Selected excerpts from the book: Lab Scopes: Introductory & Advanced. Steven McAfee

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

Lecture Outline Chapter 23. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

Electrical Machines I Week 1: Overview, Construction and EMF equation

Linear Shaft Motors in Parallel Applications

STARTER - HITACHI Isuzu Trooper II DESCRIPTION TESTING STARTER PERFORMANCE TESTS Starters HITACHI. Isuzu

Electrical School DIRECT CURRENT POWER AND MACHINES. Section One

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

Armature Reaction and Saturation Effect

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

VALLIAMMAI ENGINEERING COLLEGE

Chapter 29 Electromagnetic Induction and Faraday s Law

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

Operation Construction Classification Applications. DC Motors

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

DC Generator. - The direction of current flow in the conductor is given by Fleming s right hand rule. Figure 2: Change in current direction

PI Electrical Equipment - Course PI 30.2 MOTORS

AP Physics B Ch 18 and 19 Ohm's Law and Circuits

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

Conversion of a Model A Ford Starter for 12 Volt operation. By Dick Harrell Gra-Neva A s

Chapter 5: DC Motors. 9/18/2003 Electromechanical Dynamics 1

Motor Driven Systems. Reference Manual. Dr Lal Jayamaha

Introduction: Electromagnetism:

THE MOTOR/GENERATOR OF ROBERT ADAMS

If the magnetic field is created by an electromagnet, what happens if we keep it stationary but vary its strength by changing the current through it?

INFN LNF DAΦNE. DAΦNE Storage Ring. Laminated Yoke Quadrupole Low carbon steel Magnetil B-C

Federal Urdu University of Arts, Science & Technology Islamabad Pakistan ELECTRICAL MACHINES

Electric motor testing

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Transcription:

The Effect of DC Machine Adjustment on Loop Unbalance WMEA, Edmonton, Alberta, Canada June 11-13, 13, 2008 Rich Hall Morgan AM&T Jim Shackelford Peabody Energy

Technical Contributor Jason Conrad GE Canada Peterborough, Ontario, Canada

Dragline Generator Loops HG1 HG2 HM3 HM1 HM4 HM2 HG3 HG4 Loop 1 Loop 2

Dragline Loops Contain Direct Current Generators Direct Current Motors Ammeter Shunts Cables Connections

Dragline Generator Loops Design Benefits Multiple units in each loop average out some of the variation in individual generators and motors, cabling, etc. Multiple motors and generators average out the effect of temperature variations around the house Multiple loops give some degree of control of the machine if one loop is lost

Loop Balance Ideally, the loops behave exactly the same as each other under all conditions Visually, they would look like a well-choreographed synchronized swim team

Loop Balance cont. This means each generator behaves like every other generator Each motor behaves like every other motor Each loop s s cables and connections have the same resistance as each other loop

These loops act electrically in parallel If the generators in one loop produce more Voltage than the generators in other loops, that loop will draw more current If the motors in one loop try to run faster than the motors in other loops, they cannot because they are geared together, but that loop will draw more current

These loops act electrically in parallel If the resistances of the cables and connections are lower in one loop than the other loops, that loop will draw more current

So what?? Unbalanced loop currents may cause excessive torque in some loops, cause increased mechanical wear and take life out of couplings, gears, and structural parts of the machine Unbalanced loop currents may result in too little torque in some loops and reduce the productivity of the dragline

Other Problems Unbalanced loop currents may result in increased brush and commutator wear Unbalanced loop currents may result in flashovers Unbalanced loop currents may trip the loop overcurrent Unbalanced loop currents may cause the generator field overcurrent to trip

Bigger Problems!!! Unbalanced loop currents may result in overheating some generators or motors Badly unbalanced loop currents may cause the sync motors to pull out of synchronization, especially on weak power systems

Results This may cause damage to equipment, loss of productivity, increased downtime and increased repair costs Rule of thumb in the business loss insurance industry: the cost of the repair is 10% of the business loss

How much voltage does it take to drive rated current? The rating of a GE 1045 KW generator is 475 Volts and 2200 Amperes. It does not take 475 Volts to drive rated current in the loop, however.

How much voltage does it take to drive rated current? The answer about 20 Volts per generator!!!

How much voltage does it take to drive rated current? When the machines are in a motoring quadrant, the generators are generating an electro motive force (EMF), but the motors are also generating an electromotive force that opposes the generator EMF and it is called a counter EMF (CEMF).

How much voltage does it take to drive rated current? It is the sum of the generator Voltages minus the sum of the motor Voltages in the loop that drives loop current. This Voltage divided by the loop resistance gives the loop current.

Dragline Generator Loop _ + _ HG1 + Loop Current HM3 + HM1 _ + HG3 _ Loop 1

How much voltage does it take to drive rated current? The loop resistance is most easily determined at stall when the motors are not rotating or generating any CEMF. For a 1045 KW generator, about 40 Volts per generator drives stall current (2X rated current or 4400 Amperes). Loop Resistance = (40V + 40V 0V - 0V) = 0.0181 Ohm 4400 Amperes

How much voltage does it take to drive rated current? It does not take a large Voltage imbalance to drive a lot of current when you divide it by 0.0181!!!

Standards for Loop Balance 5% of stall current at stall conditions 5% of stall current while running steady (even at peak power) 10% of stall current during transient load changes

How much voltage difference does it take to be at the recommended limits? 5% of 4400 Amperes = 220 Amperes V = IR = 220 Amperes x 0.0181 Ohms V = 3.9 Volts So a 4 Volt difference between loops is all it takes to be at 5% of stall current!

Four Quadrant Operation 2 + Volts 1 - Amps + Amps - Volts 3 4

First Quadrant Commutation Limits Loop 1 Armature Volts Unbalanced Loop Current Loop 2 Armature Amps

Loop Balance Loop 1 is the control loop and is inside the commutation limits, so it is OK. Loop 2 is the slave loop and is inside the commutation limits, so the equipment is OK. It is loafing, however, so the dragline is working at less than capacity.

First Quadrant Commutation Limits Loop 1 Armature Volts Unbalanced Loop Current Loop 2 Armature Amps

Loop Balance Loop 1 is the control loop and is inside the commutation limits, so it is OK. Loop 2 is the slave loop and is outside the commutation limits. This may lead to commutation distress, flashovers, excessive wear of couplings and gears, tripping of the machine, etc.

Assembling DC Machines To work properly together and to commutate well, machines must be built or rebuilt properly. Following are GE factory tolerances provided by GE Canada, Peterborough, Ontario.

Generators Pole centerline to pole centerline chord measured at both ends of machine minimum to maximum values must not differ by more than 0.125 (3.2 mm)

Pole Tip Spacing Frame A B Difference Between A and B is 1/8 (3.2 mm) Maximum

Generators Brush Holder Assembly holders to be set 0.070 to 0.080 from commutator surface (1.8 to 2.0 mm) axial skew must not exceed one mica thickness over the length of the commutator

0.070 0.080 (1.8 2.0 mm) Brush Box Height

Generators Circumferential brush spacing (paper tape on commutator) arcs measured from one brush toe to the next must be within 3/64 (0.047 or 1.2 mm) (MAXIMUM)

Brush Spacing F A B A = B = C = D = E = F = E Commutator Commutator D C Max. Spacing Diff. = Target is.030 On Westinghouse Equipment Max. Spacing diff =.050 on GE equip.

Generators Air Gaps all air gaps to be within +/-0.007 0.007 (0.18 mm) commutating pole air gaps may be different than main pole air gaps

Uneven And Tapered Air Gaps Pole Frame Armature Pole Frame

Air Gap Taper Gauge

Air Gap Measurement

Motors Pole centerline to pole centerline chord measured at both ends of machine minimum to maximum values must not differ by more than 0.125 (3.2 mm)

Motors Brush Holder Assembly holders to be set 0.070 to 0.080 from commutator surface (1.8 to 2.0 mm) axial skew must not exceed one mica thickness over the length of the commutator

Motors Circumferential brush spacing (paper tape on commutator) arcs measured from one brush toe to the next must be within 3/64 (0.047 or 1.2 mm)

Motors Air Gaps all air gaps to be within +/-0.007 0.007 (0.18 mm) commutating pole air gaps may be different than main pole air gaps

g N N = Number of Turns g = Air Gap

e N i φ Flux φ α N x i

SATURATION CURVE Flux in φ Air Gap Air Air Gap Gap Region Region Iron Saturation Region N x I (Ampere F Turns)

Generated Volts Volts = E. M. F. = B x L xv where B = Flux Density ( φ / area) L= Length of the conductor V = Velocity of the conductor N V L - 4 2 0 2 4 + I F e

Generator V α B x L x V V (EMF) α B α I Field

Speed V = B x L x V V α B x RPM Motor L RPM α Volts α Volts B Torque F α B x I A x L I Field Torque = Force x Radius Torque α B x I A r B ( Flux Density )

Motor V α B x L x V V α B x L x RPM V (CEMF) α B x RPM α I Field x RPM

Generator Data Sheet

600 500 No Load Saturation Curve Armature Volts 400 300 200 100. MCF866B, 836 KW, 475 Volt, 1760 Ampere, 1200 RPM. 0 2 4 6 8 10 12 14 16 18 20 Field Amps

Load Curve 836 KW Gen. Armature Volts Arm. Amps Field Amps 600 0 18.9 575 1120 18.6 550 2230 18.6 450 2500 13.5 350 2770 11.2 250 3030 9.4 40 3600 6.2

Adjusting DC Machines - Factory Black Band Method See the paper NECP Tuning DC Motors and Generators Jun 07 on the WMEA web site wmea.net for other methods of tuning DC machines

Buck Boost Curve Buck Amps Boost Amps 0 X X X 50 100 150 No Load Band Center on Buck Side (Strong) Corrective action shift brush rigging with rotation (motor) or against rotation (generator) Load Amps (%)

Buck Boost Curve X Buck Amps Boost Amps 0 X X No Load Band Center on Boost Side (Weak) 50 100 150 Corrective action shift brush rigging against rotation (motor) or with rotation (generator) Load Amps (%)

Buck Boost Curve Buck Amps Boost Amps 0 X X Band Center on Boost Side (Weak) x x No sparking in black area, sparking outside black area 50 100 150 x Band Center x Corrective Action Remove nonmagnetic shims, add magnetic shims x x Load Amps (%)

Buck Boost Curve Buck Amps Boost Amps 0 X X x Corrective Action Remove magnetic shims, add non magnetic shims 50 100 150 x Band Center x Band Center on Buck Side (Strong) Sparking with no buck or boost x x Load Amps (%) x

Voltage or RPM Regulation Defined Decreased Voltage or RPM Regulation Volts or RPM Increased Voltage or RPM Regulation Armature Amps

Generator increased main pole air gap Saturation Curve Regulation Volts Volts Regulation decreases Before After Field Amps Armature Amps

Generator decreased main pole air gap Saturation Curve Regulation Volts Volts Regulation increases Before After Field Amps Armature Amps

Generator increased comm pole air gap or add nonmagnetic shims Saturation Curve Regulation Volts No Effect Volts Regulation increases Before After Field Amps Armature Amps

Generator decreased comm pole air gap or remove nonmagnetic shims Saturation Curve Regulation Volts No Effect Volts Regulation deceases Before After Field Amps Armature Amps

Generator brush shift with rotation Saturation Curve Regulation Volts No Effect Volts Regulation increases Before After Field Amps Armature Amps

Generator brush shift against rotation Saturation Curve Regulation Volts No Effect Volts Regulation decreases Before After Field Amps Armature Amps

Motor increased main pole air gap Saturation Curve Regulation Volts / RPM RPM Regulation increases Before After Field Amps Armature Amps

Motor decreased main pole air gap Saturation Curve Regulation Volts / RPM RPM Regulation decreases Before After Field Amps Armature Amps

Motor increased comm pole air gap or add nonmagnetic shims Saturation Curve Regulation Volts / RPM No Effect RPM Regulation increases Before After Field Amps Armature Amps

Motor decreased comm pole air gap or remove nonmagnetic shims Saturation Curve Regulation Volts / RPM No Effect RPM Regulation decreases Before After Field Amps Armature Amps

Motor Brush shift with rotation Saturation Curve Regulation Volts / RPM No Effect RPM Regulation increases Before After Field Amps Armature Amps

Motor Brush shift against rotation Saturation Curve Regulation Volts / RPM No Effect RPM Regulation decreases Before After Field Amps Armature Amps

Voltage Regulation Shunt Generator Low Voltage Regulation Volts Armature Amps

Voltage Regulation Shunt Generator Delta Volts Low Voltage Regulation Volts Delta Amps Armature Amps

Voltage Regulation Differential Compound Generator Higher Voltage Regulation Delta Volts Volts Delta Amps Armature Amps

Differentially Compound Generators Differentially compound generators limit loop current unbalances, as generators that are more heavily loaded (loop unbalance) will drop in voltage and shed some load. This helps, of course, but does not cure loop unbalance.

Machine Adjustments and Loop Balance Summary DC machines must be built to accepted tolerances of air gaps, brush spacing, brush box heights, pole spacing, comm pole bolt material, etc. to be as much alike as possible for the machines to commutate well and share load. Connections within the machines must be tight to minimize variation in excitation currents and loop resistance.

Machine Adjustments and Loop Balance Summary cont. When machines are disassembled and reassembled, it is important to keep track of shims, especially commutating pole shims. Both the thickness and order of shims are important! There is not an easy way to correct interpole shimming in the field, so care with the machines when working on them in shops is critical.

Machine Adjustments and Loop Balance Summary cont. There are many things that can contribute to commutation issues: rough commutators, symmetry of assembly, brush grades and construction, faulty machine components and electrical connections. Sometimes people try to fix machines by tuning them up with neutral adjustments. Remember this affects machine output and loop balance, and you cannot adjust out these underlying causes of commutation distress.

Field Process to Address Loop Unbalances Take Time versus: Drive Reference, Armature Volts and Amps, and Motor Field Current Make Stud to Stud Spacing Correct Set Neutral (on GE Generator 1/8 with Rotation) Adjust Generator Air Gaps to Ensure that the Sum of the Volts in Each Loop are Equal within 2.5 Volts per Generator in the Loop ( 4 Generators in the Loop 10 Volts) Trim Motor Fields As Necessary Adjust Motor Neutral As Last Resort (Should be at Neutral Not with or Against Rotation) If Possible Re-wire the Motion to Two Loops

Oversize Hole Use ½ Thin Wall Conduit to Center Stud on Yoke

Lot 8 2570W Hoist Unbalance As Found 485 Amps 12.2%

Lot 8 2570W Drag Unbalance As Found 988 Amps 24.9%

Lot 8 2570W Hoist and Drag Unbalances As Left After Adjustments and Making Both Motions into Two Loops Hoist Unbalance 53 Amps 1.3% Drag Unbalance 95 Amps 2.4%

Key 2 8750 Drag Unbalance As Found 1800 Amps 50%

Key 2 8750 Drag Unbalance As Left 59 Amps 1.6%

Key 2 8750 Hoist Unbalance As Found 616 Amps -15.6%

Key 2 8750 Hoist Loop Unbalance As Left 139 Amps 3.5%

Related WMEA Papers available on wmea.net National Carbon Successful Brush Performance Jun 05 NECP Tuning DC Motors and Generators Jun 07

Reference Materials Loop Unbalance Guidelines GE Benchmark, January 1997, Steve Baade Loop Unbalance Guidelines GE Benchmark, April 1997, Steve Baade GE DC Machine Adjustments and Operating Characteristics

Reference Web Sites Morgan AM&T National Electrical Carbon www.morganamt.com GE Motors - www.gemotors.com