SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.
The convincing solution. We have been developing and producing transformerless inverters for over 20 years. Our engineers have used this know-how in adapting the singlephase SolarMax S series string inverters to satisfy a broad range of requirements even better. Installation operators benefi t from our inverters because they are convenient, reliable and high-performance; our installers appreciate them because they can be quickly installed, are easily commissioned and can be expanded without diffi culty. Although all the inverters in the S series are smaller than other comparable devices, in the long term their performance is more reliable. It is this reliability, together with our unique after-sales service, which is the best possible guarantee for every investment. Maximum pay-back Swiss Quality An investment in the SolarMax S series is free of risk. These long-lasting, rugged and high-quality devices have a consistently high euro-effi ciency of up to 96.2 %, meaning they get more out of any solar installation. They are a worthwhile investment. Each inverter in the SolarMax S series is TÜV type approved and satisfi es all the requirements of the GS mark of conformity for product safety. Thanks to our high quality standards we can grant a standard fi ve-year manufacturer s warranty for each string inverter which can be extended optionally to a maximum of 25 years.
Suitable for outdoor and indoor installation High-quality and rugged aluminium housing gives the electronic components the best possible protection. The IP54 protection class also permits all inverters in the SolarMax S series to be installed and safely operated both indoors and outdoors. Competent after-sales service If a device fails to function normally there is a hotline ready to help you fi nd the source of the malfunction. If the device is the cause of the malfunction we will replace it without delay. In addition, we also support our partners with regular training and our free MaxDesign design software, which makes creating an installation as easy as anything!
Innovative cooling system No matter how hot the sun shines, the inverters in the SolarMax S series always deliver best performance. The intelligent cooling concept exhausts heat effi ciently out of the housing while the sensors continuously monitor the operating temperature. In extreme cases the output is reduced to protect the inverters against over-heating. Smart operation and communication All the relevant information and settings are presented on the straight-forward graphics display. An integrated data logger stores all the important data from the sensors. Every inverter is equipped with an RS485 and Ethernet standard interface and can be easily enhanced by adding on MaxComm components. Easier-than-ever installation The SolarMax S series inverters are easy, compact and their plug-in, easily accessible connections can be installed in no time. Thanks to the included mounting rails they can be easily mounted on the wall. The integrated DC circuit breakers enable the inverters to be disconnected from the solar generator in one step.
MaxComm for system monitoring MaxWeb The MaxWeb xp data logger forms the core of the web-based monitoring system; it enables multimedia communication with the photovoltaic plant and sends information via the internet to wherever you wish to receive it. MaxRemote enables remote-controlled performance reduction by the operator. MaxWeb Portal (performance, yield, alarm) SMS (alarm) E-Mail (alarm, XML) MaxMeteo MaxWeb xp WWW MaxRemote (interface) MaxDisplay (interface: performance, yield) MaxCount MaxMonitoring MaxMonitoring The cost-free app visualises the performance data of the photovoltaic system and of individual inverters on site. MaxVisio A touch display visualises the data from a photovoltaic plant including individual inverters. MaxVisio MaxTalk MaxTalk User-friendly PC software for on site communication and for local system monitoring.
Specifications (United Kingdom) SolarMax 2000S SolarMax 3000S SolarMax 4200S SolarMax 6000S Input values Maximum PV generator output power 1) 2 300 W 3 300 W 5 000 W 6 000 W MPP voltage range 100 V 550 V 100 V 550 V 100 V 550 V 100 V 550 V Minimum voltage for rated power 170 V 235 V 180 V 220 V Maximum DC voltage 600 V 600 V 600 V 600 V Maximum DC current 11 A 11 A 22 A 22 A Connection type MC4 MC4 MC4 MC4 Output values Rated output power 1 800 W 2 500 W 3 680 W for G83 / 4 600 W 3 800 W for G59 Maximum apparent output power 1 980 VA 2 750 VA 4 180 VA 5 060 VA Nominal mains voltage / range 230 V / 184 V...300 V 230 V / 184 V...300 V 230 V / 184 V...300 V 230 V / 184 V...300 V Maximum AC current 12 A 12 A 16 A for G83 / 19 A for G59 22 A Mains nominal frequency / range 50 Hz / 45 Hz 55 Hz Power factor cos(φ) Adjustable from 0.8 overexcited to 0.8 underexcited Distortion factor at rated power < 1.5 % Connection type Wieland Grid connection One-phase Efficiency M a x. e f fi cie n c y 97 % 97 % 97 % 97 % Europ. effi ciency 95.4 % 95.5 % 95.8 % 96.2 % Power input Own consumption (night) 0 W Ambient conditions Protection type compliant with EN 60529 IP54 Ambient temperature range -20 C +60 C Ambient temperature range at rated power -20 C +45 C Relative humidity 0 98% (no condensation) Configuration Display Graphic LC display with backlight and status LED Circuit type Two-stage, transformerless (no galvanic isolation) Data logger Data logger for energy yield, peak output and operating duration for the last 31 days, 12 months and 10 years Fault current monitoring Internal, AC/DC sensitive Casing Aluminium, cover powder-coated Overvoltage conductor DC Requirement class D (VDE 0675-6) or type 3 (EN 61643-11) Overvoltage conductor AC Requirement class D (VDE 0675-6) or type 3 (EN 61643-11) Standards & guidelines CE-compliant Yes EMC EN 61000-6-2 / EN 61000-6-3 / EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 Standard/guideline compliance VDE 0126-1-1 / VDE-AR-N 4105 / DK 5940 Ed. 2.2 / RD 661 / RD 1699 / G83/1-1 / G59/2 2) / PPC Guide / C10/11 / EN50438 3) Device safety Type approved TÜV Rheinland, GS certifi ed safety VDE Interfaces Data communication RS485 / Ethernet via two RJ45 sockets Status signalling contact M12 connector with relay as N/C contact / N/O contact Weight & dimensions Weight 13 kg 13 kg 15 kg 15 kg Dimensions in mm (W x H x D) 545 x 290 x 185 545 x 290 x 185 545 x 290 x 185 545 x 290 x 185 Warranty The product sheet specifi cations relate to the country setting Belgium. Standard 5 years / extension to 10, 15, 20 or 25 years possible 1) recommended overdimensioning 15 % (ISE Fraunhofer study), varies depending on local requirements (location, system specifi cations, grid connection guidelines, laws). All rights, amendments and errors reserved. 2) Only the inverters SolarMax 4200S and SolarMax 6000S 3) Portugal SolarMax 6000S efficiency curve 100 98 96 94 92 90 88 86 84 82 80 UDC = 220 V UDC = 320 V UDC = 420 V ηeuro(220 VDC) = 95.0 % ηeuro(320 VDC) = 95.5 % ηeuro(420 VDC) = 96.2 % 0 10 20 30 40 50 60 70 80 90 100 Output power PAC,nom [%] 2012/01 en-uk Effi ciency η [%]
G83/1-1 TYPE VERIFICATION TEST SHEET SSEG DETAILS Type Technology Manufacturer Maximum AC output power Maximum AC current TEST HOUSE DETAILS Name and address SolarMax 4200S Photovoltaic Inverter Sputnik Engineering AG Höheweg 85 2502 Biel/Bienne Switzerland Tel. +41 32 346 56 00 Fax +41 32 346 56 09 4180 W 16 A Sputnik R&D Labs Sputnik Engineering AG Höheweg 85 2502 Biel/Bienne Switzerland Tel. +41 32 346 56 00 Fax +41 32 346 56 09 E-mail hotline@solarmax.com TEST DETAILS Date of test 30.08.2011 Name of test engineer Pascal Felder Signature of test engineer Note: Conformity with G83/1-1 and the test results in this document can only be guaranteed if 1 the GB country setting is selected when the inverter is commissioned. the fi rmware-version on the inverter is 1.5.10950 or higher.
POWER QUALITY Harmonic current emissions [A] Maximum permissible harmonic current emissions as per BS EN 61000-3-2 Harmonic 2 nd 3 rd 5 th 7 th 9 th 11 th 13 th 15 th - 39 th Limit 1.08 2.3 1.14 0.77 0.4 0.33 0.21 0.15 x (15/n) Test value (maximum) 0.015 0.088 0.044 0.055 0.046 0.022 0.024 0.012 Voltage fluctuations and flicker Maximum permissible voltage fluctuation (expressed as a percentage of nominal voltage at 100% power) and flicker as per BS EN 61000-3-3 Starting Stopping Running Limit 4% 4% P ST = 1.0 P LT = 0.65 Test value 0.2% 0.2% 0.023 0.023 Limit DC injection 20 ma (tested at three power levels) Power factor 0.95 lag <> 0.95 lead (tested at three AC voltage levels and P Rated ) Test level 10% 55% 100% 212 V 230 V 248 V Test value 19 ma 18 ma 12 ma 0.98 0.98 0.98 UNDER / OVER FREQUENCY TESTS Under frequency Over frequency Parameter Frequency Time Frequency Time Limit* 47 Hz +/- 0.5% 5 s 50.5 Hz +/- 0.5% 5 s Setting 47.0 Hz < 5 s 50.5 Hz < 5 s Trip value 46.9 Hz < 5 s 50.6 Hz < 5 s UNDER / OVER VOLTAGE TESTS Under voltage Over voltage Parameter Voltage Time Voltage Time Limit* 207 V 5 s 264 V 5 s Setting 211 V < 5 s 260 V < 5 s Trip value 208 V < 5 s 263 V < 5 s LOSS OF MAINS TEST Method used Frequency shift with resonant circuit Output power 10% 55% 100% Limit* 5 s 5 s 5 s Setting Trip value < 5 s < 5 s < 5 s * Note: G83 allows inverter connected SSEG to extend trip times for the protection functions on this page to max. 5 seconds. 2
RECONNECTION TIMES Parameter Under/Overvoltage Under/Overfrequency Loss of mains Minimum value 180 s 180 s 180 s Actual setting 180 s 180 s 180 s Recorded value > 180 s > 180 s > 180 s FAULT LEVEL CONTRIBUTION Photovoltaic SSEGs are inverter connected, therefore they are deemed to comply automatically with this clause and no further tests are required. SELF MONITORING SOLID STATE SWITCHING Not applicable as electro-mechanical relays are used. 3