or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202 Max. operating pressure Regulating pressure range (at O point) Hysteresis rror of scale Repeatability ontacts Wiring specifications mbient and fluid temperature Weight Switch haracteristics Max. contact capacity Voltage Impact resistance lectrical ircuit Up to 100 V/ Reed switch IS1000-01 ir/inert gas 1.0 MPa 0.7 MPa 0.1 to 0.4 MPa 0.08 MPa or less ±0.05 MPa ±0.05 MPa Grommet, Lead wire length 0.5 m (Standard) ir 5 to 60 (No freezing) R 74 g 24 V/ or less 50 m Operating pressure (MPa) 2 V, 2 W 0.5 48 V/ m G 100 V/ 20 m Operating Pressure Range 0.4 0.3 0.2 0.1 ON pressure Hysteresis O pressure ZS IS PS Z I S3 PS Z I S 1 2 ZSP IS2 IS ZSM P2 I ata 0 0.1 0.2 0.3 0.4 Set pressure scale (MPa) IS1000 01 S 01 N01 R 1 /8 NPT 1 /8 Seal Nil S None With seal Option X201 Lead wire length 3 m Regulating pressure range X202 0.1 to 0.6 MPa X2 Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa 16-9-1
Series IS1000 onstruction 500 58.5 50 20 5 q w R 1 /8 t u y i!0 o e r 0.1 0.2 0.3 0.4 MPa IS1000 omponent Parts No. q w e r t y u i o!0 escription Shield plate Switch assembly Piston PT fittings djusting screw Pointer Spring Scale plate Miniseal Y type Magnet Material Rolled steel plate Polyacetal Zinc die-casted rass rass Stainless steel 4-WP Rigid vinyl chloride NR Rare earth magnet Precautions e sure to read before handling. Refer to pages 16--3 and 16--4 for Safety Instructions and ommon Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. 1. onnect load before connecting with power source. 2. In the case of induction load or lead wire exceeding 5 m long, the following contact protection box should be used. It may lead to damage to a switch. Part no. -P11 -P12 Voltage 100 V 24 V Lead wire length Switch side: 0.5 m Load side: 0.5 m 3. Internal circuit of contact protection box Surge absorber ondenser -P11 hoke coil -P12 hoke coil Resistance rown lue (+) rown ( ) lue Wiring 4. How to connect contact protection box onnect the lead wires from the body and the contact protective box side indicated SWITH. Lead wire should be as short as possible, within 1 m. 5. imensions of lead wire nclosure: ø 3.4 Insulator: ø 1.1 onductor: ø 0.64 Mounting/Piping 1. When changing piping by hand, hold body. lectrical wire must not be subjected to excessive force. It may cause a malfunction or damage. 2. o not drop nor apply excessive force. It may cause a malfunction or damage. 3. Tighten IS1000-01 applying the spanner on the PT fitting part. 4. Mounting direction is available in either horizontal or perpendicular. Pressure Source 1. o not use with corrosive gases or fluids. 2. Never use in an environment where flammable fluid or gas is used. Since this is not an explosion-proof construction, it may lead to an explosive disaster. 3. void use in vacuum applications. Switch may be imploded. Pressure Setting 1. Scale of switching set display is the set value at the pressure drop. 2. When detecting ON-pressure signal, note that set pressure on scale plate plus ON-O differential (Hysteresis) will be ON-pressure signal. 3. Pressure display on the scale plate is just as a reference guide. or an accurate setting, measure it by pressure gauge. Operating nvironment 1. void using a switch in a magnetic environment. It may cause a malfunction. 2. o not use in such an environment, where water or oil is splashed. Since it is the open type construction, if water or oil make an ingress into the internal parts, the electric circuit will be corroded and may result in a malfunction or damage. 3. void vibration. Vibration may cause malfunction or may cause setting to be incorrect. 16-9-2
ttachments Pressure Switch with Piping dapter V Max. operating pressure Set pressure range (off) ifferential mbient and fluid temperature Switch haracteristics ontact point structure Max. contact point capacity Voltage, IS1000 with piping adapter 2 3 4 N ody size or 2000 or 2500, 00 or 00-02 to 04 3 03 YL Thread Rc(PT) NPT G(P) ir 5 to 60 (No condensation) 2V /2W 12V, 24V, 48V, 100V, 12V to 24V : 50m, 48V : m, 100V : 20m ttachment Y YL YT Piping adapter port size 01 02 03 04 06 (1) IS1000-2 01Y 1/ 8 IS1000-2 02Y 1 / 4 IS1000-2 03Y 3 / 8 IS1000-3 02Y 1 / 4 IS1000-3 03Y 3/ 8 IS1000-3 04Y 1/ 2 IS1000-4 02Y 1/ 4 IS1000-4 03Y 3/ 8 IS1000-4 04Y 1 / 2 IS1000-4 06Y 3/ 4 Options X201 Length of lead wire: 3m X202 Setting pressure range: 0.1 to 0.6MPa X250 Reverse mounting (Left side mounting style) Without attachment With attachment With attachment and L type bracket With attachment and T type bracket 1 / 8 1/ 4 3/ 8 1 / 2 3/ 4 28 73 62 18.5 26 80 63 16.5 80 63 17.5 33 87 66 17.5 pplicable model 2000, 2010, 2020 20, 20 W2000 2500, 2520, 25 00, 10, 20, W00, W50 00, 10, 20, W00, W50 (2) 50 87 66 17.5 Note1) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and for G(P). Note2) an NOT be mounted on " 0-06" and "W 0-06". With retainer, O ring and bolt. onsult SM when mounting the pressure switch on " 0-06" and "W 0-06". or more information, refer to p.3.0-0. U R IR VX W MR WM W ITV V V VY G L ttachments for IS1000 applicable model No. IS1000-201 to 203 IS1000-2 to 4 IS1000-2 to 6 Y type standard Y20 Y Y YL type with L type bracket Y20L YL YL YT type with T type bracket Y20T YT YT 1.1-18
ttachments Pressure Switch: (S) ompact pressure switch can be mounted easily. Makes it easier to detect pressure in lines. Max. operating pressure Set pressure range (off) ifferential mbient and fluid temperature Switch haracteristics ontact point structure Max. contact point capacity Voltage, or more information, refer to SM catalog. (atalog No.824) IS1000M 4 YT ir 5 to 60 (No condensation) 2V /2W 12V, 24V, 48V, 100V, 12V to 24V : 50m, 48V : m, 100V : 20m IS1000M-2Y IS1000M-3Y IS1000M-4Y IS1000M-5Y IS1000M-6Y 73.5 62.6 28 10 82 64.9 29 11 88.7 67.6 91 68 100 72.5 35 44 54 aution on ssembling pplicable model 2000, 2020, 20 2500, 2520, 25 00, 20, 00, 20, 00-06, 20-06 -06 5000, 5500, 6000 5020, 5520, 6020 ttachment for pressure switch can be installed at the IN/OUT side of, R, L, M and. Mounting at the IN/OUT side of W and upward handle ofr is not possible. V U R IR VX W MR WM W ITV V V VY G L 2 3 4 5 6 ody size or 2000 or 2500, 00 or 00-02 to 04 or 00-06 or 5000, 6000 ttachment Y YL YT Options X201 X202 Without attachment With attachment With attachment and L type bracket With attachment and T type bracket Length of lead wire: 3m Set pressure range: 0.1 to 0.6MPa ttachments for IS1000M applicable model No. IS1000M-2 IS1000M-3 IS1000M-4 IS1000M-5 IS1000M-6 Y type standard Y20M YM YM Y50M Y60M YL type with L type bracket Y20LM YLM YLM Y50LM Y60LM YT type with T type bracket Y20TM YTM YTM Y50TM Y60TM 1.1-20
ttachment Series Pressure Switch (S) compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line. pprox. 500 Maximum operating pressure Set pressure range (off) ifferential mbient and fluid temperature Switch characteristics ontact point configuration Maximum contact point capacity Operating voltage:, Maximum operating current ross Interface () M5 x 0.8,,,, ir 5 to 60 (with no freezing) 2V(), 2W() 100V or less, 12V to 24V: 50m, 48V: m, 100V: 20m Pipings are possible in all 4 directions. IN/OUT ports are not machined for threads. ontact SM if threaded (machined) ports are required. ross interface IS1000M-20 IS1000M- IS1000M- IS1000M-50 IS1000M-60 11 13 17 22 76 86 95 99 92.5 IS1000M ody size 20 or 20 or 25, or -02 to 04 50 or -06 60 or 50, 55, 60 66 72 77 79 68.5 28 36 44 53 Note) Separate interfaces are required for modular unit. enter of.r.l. body enter of.r.l. body pplicable model 20 25, -06 50, 55, 60 ccessories X201 Lead wire length: 3m Regulating pressure X202 range: 0.1 to 0.6MPa X207 MPa/PSI ual scale Lead wire length: 3m; X2 Regulating pressure range: 0.1 to 0.6MPa This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) : 4-Rc : Without thread autions in Mounting When mounting a cross interface directly on the IN side of the lubricator, be sure to use a series KM check valve between the lubricator and cross interface. actory mounting of a cross interface on the model is available as a special order. Y-M5 Y24-01 Y24-02 Y34-01 Y34-02 Y44-02 Y44-03 Y54-03 Y54-04 M5 49 60 72 16 43 48 62 22 28 36 25 48 54 62 pplicable model 10 20 25, -06 Notes) in the model numbers indicates a thread type. No indication is necessary for Rc; however, indicate N for NPT, and for G. If threaded ports are required, they are available as a special order. ontact SM. 16
ttachment Series Pressure Switch with Piping dapter (P) with piping adapter pprox. 500 Maximum operating pressure Set pressure range (when O) ifferential mbient and fluid temperature Switch characteristics ontact point configuration Maximum contact point capacity Operating voltage:, IS1000 with piping adapter 20 ir 5 to 60 (with no freezing) ody size or 20 or 25, or -02 to 04 2V(), 2W() 100V or less 12V to 24V, : 50m 48V, : m 100V, : 20m 03 Thread type Nil N Rc NPT G Note 1) IS1000-20 01 IS1000-20 02 IS1000-20 03 IS1000-02 IS1000-03 IS1000-04 IS1000-02 IS1000-03 IS1000-04 IS1000-06 3/4 68 57 28 16 32 74.5 60.5 13 32 80.5 62.5 37 12.5 pplicable model 20 R20, W20 WM20, W20 25, R25, R, W WM, W R, W WM, W Option X201 Lead wire length: 3m X202 Regulating pressure range: 0.1 to 0.6MPa X207 MPa/PSI ual scale X2 Lead wire length: 3m; Regulating pressure range: 0.1 to 0.6MPa X250 Opposite-side mounting (Left-side mounting type) X251 Lead wire length: 3m; Opposite-side mounting (Left-side mounting type) X252 Set pressure range: 0.1 to 0.6MPa; Opposite-side mounting (Left-side mounting type) X253 Lead wire length: 3m; Regulating pressure range: 0.1 to 0.6MPa; Opposite-side mounting (Left-side mounting type) Piping adapter port size Symbol 01 02 03 04 06 Port size 3/4 enter of.r.l. body Note 1) in the model numbers indicates a thread type. No indication is necessary for Rc; however, indicate N for NPT, and for G. Note 2) pressure switch cannot be mounted on -06 and W -06. Separate interfaces are required for modular unit. The pressure switch on -06 and above and W -06 can be mounted by screwing IS1000-01 into the piping adapter 500-06-X501 or 600-06-X501 to 600-06 to 10-X501 (with top-face thread Rc ). Products with a premounted switch are available as a special order. Please contact SM regarding their availability. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) 20 ody size Note 2)